{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T00:54:50Z","timestamp":1778806490068,"version":"3.51.4"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T00:00:00Z","timestamp":1652918400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T00:00:00Z","timestamp":1652918400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>To investigate the clinical effect of internal fixation of a Ni\u2013Ti arched shape-memory connector in the treatment of distal tibiofibular syndesmosis ligament injury.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>From January 2013 to January 2016, 108 cases of ankle fracture with distal tibiofibular syndesmosis ligament injury in our hospital were selected, and all of them were fixed with ASCs or screw fixation. The functional evaluation and efficacy evaluation were performed according to the Olerud Molander Ankle Score (Omas) and SF-36. At the same time, follow-ups recorded the incidence of postoperative complications: osteoarthritis, superficial infection, symptomatic hard and soft tissue irritation, early removal and poor reduction of internal fixation, and later loss of reduction.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In the ASC(Ni\u2013Ti Arched shape-memory Connector) group, the incidence of symptomatic hardware, soft tissue or superficial infection decreased to 2.77%(from 13.8% or 11.1% in SCREW group). The early removal rate(2.77%) of internal fixation was also lower than that of the screw group. While the incidence of osteoarthritis is 13.8% in SCREW group, the incidence of osteoarthritis in the later follow-up was also as low as 1.38% in ASC group. Loss of fracture reduction due to removal of the fixation device for the distal tibiofibular syndesmosis ligament was not observed in the ASC group. With two postoperative scoring systems (OMAS and SF-36), patients in the ASC group significantly get higher score than that in SCREW group.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The design of the Ni\u2013Ti arched shape-memory connector can be adapted to the irregular anatomical structure of the malleolus and the ability to continue to contract by body temperature. The use of ASCs in fixation of articular ligaments can preserve a slight range of motion, and the results suggest that ASCs can effectively reduce the incidence of fixation looseness, fracture, infection and other complications.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05449-9","type":"journal-article","created":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T11:24:43Z","timestamp":1652959483000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Application of an arched, Ni\u2013Ti shape-memory connector in repairing distal tibiofibular syndesmosis ligament injury"],"prefix":"10.1186","volume":"23","author":[{"given":"Jinbo","family":"Zhao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuntong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuhui","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuogui","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,5,19]]},"reference":[{"issue":"4","key":"5449_CR1","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1053\/j.jfas.2015.03.010","volume":"54","author":"Y Xie","year":"2015","unstructured":"Xie Y, Cai L, Deng Z, Ran B, Hu C. Absorbable screws versus metallic screws for distal tibiofibular syndesmosis injuries: a meta-analysis. J Foot Ankle Surg. 2015;54(4):663\u201370. https:\/\/doi.org\/10.1053\/j.jfas.2015.03.010.","journal-title":"J Foot Ankle Surg"},{"issue":"2","key":"5449_CR2","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1055\/s-0036-1584187","volume":"30","author":"Y Zhang","year":"2017","unstructured":"Zhang Y, Wang P, Xia Y, et al. Application of a shape-memory alloy concentrator in displaced patella fractures: technique and long-term results. J Knee Surg. 2017;30(2):166\u201373. https:\/\/doi.org\/10.1055\/s-0036-1584187.","journal-title":"J Knee Surg"},{"issue":"1","key":"5449_CR3","doi-asserted-by":"publisher","first-page":"e000175","DOI":"10.1136\/bmjsem-2016-000175","volume":"3","author":"AJ Latham","year":"2017","unstructured":"Latham AJ, Goodwin PC, Stirling B, Budgen A. Ankle syndesmosis repair and rehabilitation in professional rugby league players: a case series report. BMJ Open Sport Exerc Med. 2017;3(1):e000175. https:\/\/doi.org\/10.1136\/bmjsem-2016-000175.","journal-title":"BMJ Open Sport Exerc Med."},{"issue":"11","key":"5449_CR4","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.3113\/FAI.2011.1102","volume":"32","author":"JA Amis","year":"2011","unstructured":"Amis JA. Avoiding suture knot prominence with suture button along distal fibula: technical tip. Foot Ankle Int. 2011;32(11):1102.","journal-title":"Foot Ankle Int"},{"issue":"11","key":"5449_CR5","doi-asserted-by":"publisher","first-page":"2283","DOI":"10.1016\/j.injury.2015.08.021","volume":"46","author":"MR Andersen","year":"2015","unstructured":"Andersen MR, Frihagen F, Madsen JE, Figved W. High complication rate after syndesmotic screw removal. Injury. 2015;46(11):2283\u20137. https:\/\/doi.org\/10.1016\/j.injury.2015.08.021.","journal-title":"Injury"},{"key":"5449_CR6","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1097\/01.blo.0000129152.81015.ad","volume":"423","author":"A Beumer","year":"2004","unstructured":"Beumer A, van Hemert WL, Niesing R, et al. Radiographic measurement of the distal tibiofibular syndesmosis has limited use. Clin Orthop Relat Res. 2004;423:227\u201334. https:\/\/doi.org\/10.1097\/01.blo.0000129152.81015.ad.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"5449_CR7","doi-asserted-by":"publisher","first-page":"197","DOI":"10.2519\/jospt.1995.21.4.197","volume":"21","author":"T Brosky","year":"1995","unstructured":"Brosky T, Nyland J, Nitz A, Caborn DN. The ankle ligaments: consideration of syndesmotic injury and implications for rehabilitation. J Orthop Sports Phys Ther. 1995;21(4):197\u2013205. https:\/\/doi.org\/10.2519\/jospt.1995.21.4.197.","journal-title":"J Orthop Sports Phys Ther"},{"issue":"5","key":"5449_CR8","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1053\/j.jfas.2004.07.003","volume":"43","author":"RK Choudhary","year":"2004","unstructured":"Choudhary RK, Theruvil B, Taylor GR. First metatarsophalangeal joint arthrodesis: a new technique of internal fixation by using memory compression staples. J Foot Ankle Surg. 2004;43(5):312\u20137. https:\/\/doi.org\/10.1053\/j.jfas.2004.07.003.","journal-title":"J Foot Ankle Surg"},{"issue":"1","key":"5449_CR9","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.fas.2017.08.001","volume":"25","author":"B Chen","year":"2019","unstructured":"Chen B, Chen C, Yang Z, Huang P, Dong H, Zeng Z. To compare the efficacy between fixation with tightrope and screw in the treatment of syndesmotic injuries: A meta-analysis. Foot Ankle Surg. 2019;25(1):63\u201370. https:\/\/doi.org\/10.1016\/j.fas.2017.08.001.","journal-title":"Foot Ankle Surg"},{"issue":"12","key":"5449_CR10","doi-asserted-by":"publisher","first-page":"5178","DOI":"10.1016\/j.actbio.2014.08.017","volume":"10","author":"DY Cong","year":"2014","unstructured":"Cong DY, Saha G, Barnett MR. Thermomechanical properties of Ni-Ti shape memory wires containing nanoscale precipitates induced by stress-assisted ageing. Acta Biomater. 2014;10(12):5178\u201392. https:\/\/doi.org\/10.1016\/j.actbio.2014.08.017.","journal-title":"Acta Biomater"},{"issue":"4","key":"5449_CR11","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1302\/0301-620X.96B4.32171","volume":"96-B","author":"H Sun","year":"2014","unstructured":"Sun H, Luo CF, Zhong B, Shi HP, Zhang CQ, Zeng BF. A prospective, randomised trial comparing the use of absorbable and metallic screws in the fixation of distal tibiofibular syndesmosis injuries: mid-term follow-up. Bone Joint J. 2014;96-B(4):548\u201354. https:\/\/doi.org\/10.1302\/0301-620X.96B4.32171.","journal-title":"Bone Joint J"},{"issue":"4","key":"5449_CR12","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1302\/0301-620X.90B4.19750","volume":"90","author":"R Dattani","year":"2008","unstructured":"Dattani R, Patnaik S, Kantak A, Srikanth B, Selvan TP. Injuries to the tibiofibular syndesmosis. J Bone Joint Surg Br. 2008;90(4):405\u201310. https:\/\/doi.org\/10.1302\/0301-620X.90B4.19750.","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"5449_CR13","doi-asserted-by":"publisher","first-page":"533","DOI":"10.3233\/THC-191638","volume":"28","author":"P Gr\u00e4ff","year":"2020","unstructured":"Gr\u00e4ff P, Alanazi S, Alazzawi S, et al. Screw fixation for syndesmotic injury is stronger and provides more contact area of the joint surface than TightRope\u00ae: a biomechanical study. Technol Health Care. 2020;28(5):533\u20139. https:\/\/doi.org\/10.3233\/THC-191638.","journal-title":"Technol Health Care"},{"issue":"2","key":"5449_CR14","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1016\/j.injury.2018.10.037","volume":"50","author":"ZC Hao","year":"2019","unstructured":"Hao ZC, Xia Y, Wu JH, Zhang YT, Xu SG. Application of a Ni-Ti arched shape-memory connector in unstable lateral malleolus fractures: a retrospective study. Injury. 2019;50(2):551\u20137. https:\/\/doi.org\/10.1016\/j.injury.2018.10.037.","journal-title":"Injury"},{"issue":"6","key":"5449_CR15","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1097\/00005131-200407000-00001","volume":"18","author":"P H\u00f8iness","year":"2004","unstructured":"H\u00f8iness P, Str\u00f8ms\u00f8e K. Tricortical versus quadricortical syndesmosis fixation in ankle fractures: a prospective, randomized study comparing two methods of syndesmosis fixation. J Orthop Trauma. 2004;18(6):331\u20137. https:\/\/doi.org\/10.1097\/00005131-200407000-00001.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"5449_CR16","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.fas.2011.11.003","volume":"18","author":"T Huber","year":"2012","unstructured":"Huber T, Schmoelz W, B\u00f6lderl A. Motion of the fibula relative to the tibia and its alterations with syndesmosis screws: a cadaver study. Foot Ankle Surg. 2012;18(3):203\u20139. https:\/\/doi.org\/10.1016\/j.fas.2011.11.003.","journal-title":"Foot Ankle Surg"},{"issue":"16","key":"5449_CR17","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.2106\/JBJS.20.00992","volume":"102","author":"KJ Hunt","year":"2020","unstructured":"Hunt KJ. In fibular fractures with associated syndesmotic injury, open reduction and internal fixation with the tightrope device reduced malreduction at 3 months compared with screw fixation. J Bone Joint Surg Am. 2020;102(16):1465. https:\/\/doi.org\/10.2106\/JBJS.20.00992.","journal-title":"J Bone Joint Surg Am"},{"issue":"5\u20136","key":"5449_CR18","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1007\/s00276-003-0156-4","volume":"25","author":"Barton\u00ed\u010dek Jan","year":"2003","unstructured":"Jan Barton\u00ed\u010dek. Anatomy of the tibiofibular syndesmosis and its clinical relevance. Surg Radiol Anat. 2003;25(5\u20136):379\u201386.","journal-title":"Surg Radiol Anat"},{"issue":"6","key":"5449_CR19","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1016\/j.injury.2015.02.004","volume":"46","author":"T Kortekangas","year":"2015","unstructured":"Kortekangas T, Savola O, Flinkkil\u00e4 T, et al. A prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography. Injury. 2015;46(6):1119\u201326. https:\/\/doi.org\/10.1016\/j.injury.2015.02.004.","journal-title":"Injury"},{"issue":"1","key":"5449_CR20","doi-asserted-by":"publisher","first-page":"49","DOI":"10.3113\/FAI.2008.0049","volume":"29","author":"K Forsythe","year":"2008","unstructured":"Forsythe K, Freedman KB, Stover MD, Patwardhan AG. Comparison of a novel FiberWire-button construct versus metallic screw fixation in a syndesmotic injury model. Foot Ankle Int. 2008;29(1):49\u201354. https:\/\/doi.org\/10.3113\/FAI.2008.0049.","journal-title":"Foot Ankle Int"},{"key":"5449_CR21","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.urology.2016.09.007","volume":"99","author":"B Le","year":"2017","unstructured":"Le B, McVary K, McKenna K, Colombo A. A Novel Thermal-activated shape memory penile prosthesis: comparative mechanical testing. Urology. 2017;99:136\u201341. https:\/\/doi.org\/10.1016\/j.urology.2016.09.007.","journal-title":"Urology"},{"issue":"1","key":"5449_CR22","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.hjc.2018.06.012","volume":"60","author":"LCS Res","year":"2019","unstructured":"Res LCS, Lubberts B, Shah SH, DiGiovanni CW. Health-related quality of life after adverse bleeding events associated with antithrombotic drug therapy - A systematic review. Hellenic J Cardiol. 2019;60(1):3\u201310. https:\/\/doi.org\/10.1016\/j.hjc.2018.06.012.","journal-title":"Hellenic J Cardiol"},{"issue":"5","key":"5449_CR23","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1203\/PDR.0b013e31816a9d18","volume":"63","author":"DS Levi","year":"2008","unstructured":"Levi DS, Kusnezov N, Carman GP. Smart materials applications for pediatric cardiovascular devices. Pediatr Res. 2008;63(5):552\u20138. https:\/\/doi.org\/10.1203\/PDR.0b013e31816a9d18.","journal-title":"Pediatr Res"},{"key":"5449_CR24","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.ijsu.2018.11.007","volume":"60","author":"L Xie","year":"2018","unstructured":"Xie L, Xie H, Wang J, et al. Comparison of suture button fixation and syndesmotic screw fixation in the treatment of distal tibiofibular syndesmosis injury: a systematic review and meta-analysis. Int J Surg. 2018;60:120\u201331. https:\/\/doi.org\/10.1016\/j.ijsu.2018.11.007.","journal-title":"Int J Surg"},{"issue":"6","key":"5449_CR25","doi-asserted-by":"publisher","first-page":"372","DOI":"10.2519\/jospt.2006.2195","volume":"36","author":"CF Lin","year":"2006","unstructured":"Lin CF, Gross ML, Weinhold P. Ankle syndesmosis injuries: anatomy, biomechanics, mechanism of injury, and clinical guidelines for diagnosis and intervention. J Orthop Sports Phys Ther. 2006;36(6):372\u201384. https:\/\/doi.org\/10.2519\/jospt.2006.2195.","journal-title":"J Orthop Sports Phys Ther"},{"key":"5449_CR26","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.msec.2016.02.066","volume":"63","author":"L Jinlong","year":"2016","unstructured":"Jinlong L, Tongxiang L, Chen W, Limin D. Surface corrosion enhancement of passive films on NiTi shape memory alloy in different solutions. Mater Sci Eng C Mater Biol Appl. 2016;63:192\u20137. https:\/\/doi.org\/10.1016\/j.msec.2016.02.066.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"issue":"1","key":"5449_CR27","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1097\/BOT.0b013e3181a9f7a5","volume":"24","author":"A Manjoo","year":"2010","unstructured":"Manjoo A, Sanders DW, Tieszer C, MacLeod MD. Functional and radiographic results of patients with syndesmotic screw fixation: implications for screw removal. J Orthop Trauma. 2010;24(1):2\u20136. https:\/\/doi.org\/10.1097\/BOT.0b013e3181a9f7a5.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"5449_CR28","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1016\/j.injury.2011.10.002","volume":"43","author":"GA Naqvi","year":"2012","unstructured":"Naqvi GA, Shafqat A, Awan N. Tightrope fixation of ankle syndesmosis injuries: clinical outcome, complications and technique modification. Injury. 2012;43(6):838\u201342. https:\/\/doi.org\/10.1016\/j.injury.2011.10.002.","journal-title":"Injury"},{"issue":"1","key":"5449_CR29","first-page":"68","volume":"36","author":"SA Norkus","year":"2001","unstructured":"Norkus SA, Floyd RT. The anatomy and mechanisms of syndesmotic ankle sprains. J Athl Train. 2001;36(1):68\u201373.","journal-title":"J Athl Train"},{"issue":"7","key":"5449_CR30","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1016\/j.dental.2016.03.017","volume":"32","author":"NA Obaisi","year":"2016","unstructured":"Obaisi NA, Galang-Boquiren MT, Evans CA, et al. Comparison of the transformation temperatures of heat-activated Nickel-Titanium orthodontic archwires by two different techniques. Dent Mater. 2016;32(7):879\u201388. https:\/\/doi.org\/10.1016\/j.dental.2016.03.017.","journal-title":"Dent Mater"},{"issue":"5","key":"5449_CR31","doi-asserted-by":"publisher","first-page":"555","DOI":"10.3109\/17453679209154737","volume":"63","author":"O B\u00f6stman","year":"1992","unstructured":"B\u00f6stman O, P\u00e4iv\u00e4rinta U, Manninen M, Rokkanen P. Polymeric debris from absorbable polyglycolide screws and pins. Intraosseous migration studied in rabbits. Acta Orthop Scand. 1992;63(5):555\u20139. https:\/\/doi.org\/10.3109\/17453679209154737.","journal-title":"Acta Orthop Scand."},{"issue":"3","key":"5449_CR32","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1007\/BF00435553","volume":"103","author":"C Olerud","year":"1984","unstructured":"Olerud C, Molander H. A scoring scale for symptom evaluation after ankle fracture. Arch Orthop Trauma Surg. 1984;103(3):190\u20134. https:\/\/doi.org\/10.1007\/BF00435553.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"11","key":"5449_CR33","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1097\/BOT.0000000000001590","volume":"33","author":"D Sanders","year":"2019","unstructured":"Sanders D, Schneider P, Taylor M, et al. Improved reduction of the tibio-fibular syndesmosis with tightrope compared to screw fixation: results of a randomized controlled study. J Orthop Trauma. 2019;33(11):531\u20137.","journal-title":"J Orthop Trauma."},{"issue":"6","key":"5449_CR34","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1007\/s00264-012-1500-2","volume":"36","author":"T Schepers","year":"2012","unstructured":"Schepers T. Acute distal tibiofibular syndesmosis injury: a systematic review of suture-button versus syndesmotic screw repair. Int Orthop. 2012;36(6):1199\u2013206. https:\/\/doi.org\/10.1007\/s00264-012-1500-2.","journal-title":"Int Orthop"},{"issue":"11","key":"5449_CR35","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.3113\/FAI.2011.1040","volume":"32","author":"T Schepers","year":"2011","unstructured":"Schepers T, Van Esther MM, et al. Complications of syndesmotic screw removal. Foot Ankle Int. 2011;32(11):1040\u20134.","journal-title":"Foot Ankle Int"},{"issue":"7","key":"5449_CR36","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1007\/s00402-010-1225-x","volume":"131","author":"T Schepers","year":"2011","unstructured":"Schepers T. To retain or remove the syndesmotic screw: a review of literature. Arch Orthop Trauma Surg. 2011;131(7):879\u201383. https:\/\/doi.org\/10.1007\/s00402-010-1225-x.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"5449_CR37","doi-asserted-by":"publisher","first-page":"e377","DOI":"10.3928\/01477447-20160201-06","volume":"39","author":"VB Shur","year":"2016","unstructured":"Shur VB, Georgiev KG, Richards JJ. Internal compression screw exchange for reduction of distal tibiofibular syndesmotic injuries. Orthopedics. 2016;39(2):e377\u20139. https:\/\/doi.org\/10.3928\/01477447-20160201-06.","journal-title":"Orthopedics"},{"issue":"4","key":"5449_CR38","doi-asserted-by":"publisher","first-page":"232596711770285","DOI":"10.1177\/2325967117702854","volume":"5","author":"PF F\u00f6rschner","year":"2017","unstructured":"F\u00f6rschner PF, Beitzel K, Imhoff AB, et al. Five-year outcomes after treatment for acute instability of the tibiofibular syndesmosis using a suture-button fixation system. Orthop J Sports Med. 2017;5(4):2325967117702854. https:\/\/doi.org\/10.1177\/2325967117702854.","journal-title":"Orthop J Sports Med."},{"issue":"6","key":"5449_CR39","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1177\/1071100714524552","volume":"35","author":"DJ Song","year":"2014","unstructured":"Song DJ, Lanzi JT, Groth AT, et al. the effect of syndesmosis screw removal on the reduction of the distal tibiofibular joint: a prospective radiographic study. Foot Ankle Int. 2014;35(6):543\u20138. https:\/\/doi.org\/10.1177\/1071100714524552.","journal-title":"Foot Ankle Int"},{"key":"5449_CR40","unstructured":"Song Y. Comparative Study of the Clinical Results of Absorbable Screws and Cortical Bone Screws on Distal Tibiofibular Syndesmosis Injury[J]. Medical Recapitulate. ISSN:1006-2084,2013,19(12)."},{"key":"5449_CR41","unstructured":"Tao Y, Zou Y, Yang J. Clinical Application Observation of Absorbable Screw in The Treatment of Distal Tibiofibular Syndesmosis Injury[J]. Sichuan Medical Journal. ISSN:1004-0501,2016,37(06)."},{"issue":"3","key":"5449_CR42","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.foot.2015.03.001","volume":"25","author":"TA Lalli","year":"2015","unstructured":"Lalli TA, Matthews LJ, Hanselman AE, Hubbard DF, Bramer MA, Santrock RD. Economic impact of syndesmosis hardware removal. Foot (Edinb). 2015;25(3):131\u20133. https:\/\/doi.org\/10.1016\/j.foot.2015.03.001.","journal-title":"Foot (Edinb)"},{"key":"5449_CR43","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/j.msec.2014.03.060","volume":"40","author":"SM Toker","year":"2014","unstructured":"Toker SM, Canadinc D. Evaluation of the biocompatibility of NiTi dental wires: a comparison of laboratory experiments and clinical conditions. Mater Sci Eng C Mater Biol Appl. 2014;40:142\u20137. https:\/\/doi.org\/10.1016\/j.msec.2014.03.060.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"issue":"12","key":"5449_CR44","doi-asserted-by":"publisher","first-page":"1880","DOI":"10.1016\/j.injury.2013.08.011","volume":"44","author":"A Tucker","year":"2013","unstructured":"Tucker A, Street J, Kealey D, McDonald S, Stevenson M. Functional outcomes following syndesmotic fixation: a comparison of screws retained in situ versus routine removal - Is it really necessary? Injury. 2013;44(12):1880\u20134. https:\/\/doi.org\/10.1016\/j.injury.2013.08.011.","journal-title":"Injury"},{"issue":"2","key":"5449_CR45","doi-asserted-by":"publisher","first-page":"169","DOI":"10.2106\/00004623-197759020-00005","volume":"59","author":"IG Yablon","year":"1977","unstructured":"Yablon IG, Heller FG, Shouse L. The key role of the lateral malleolus in displaced fractures of the ankle. J Bone Joint Surg Am. 1977;59(2):169\u201373.","journal-title":"J Bone Joint Surg Am"},{"key":"5449_CR46","doi-asserted-by":"crossref","unstructured":"Willmott HJS. Re: Outcome and complications of treatment of ankle diastasis with tightrope fixation[J]. Injury.\u00a02010;41(10):1097.","DOI":"10.1016\/j.injury.2010.01.107"},{"issue":"3","key":"5449_CR47","doi-asserted-by":"publisher","first-page":"172","DOI":"10.5435\/00124635-199705000-00006","volume":"5","author":"TK Wuest","year":"1997","unstructured":"Wuest TK. Injuries to the Distal Lower Extremity Syndesmosis. J Am Acad Orthop Surg. 1997;5(3):172\u201381. https:\/\/doi.org\/10.5435\/00124635-199705000-00006.","journal-title":"J Am Acad Orthop Surg"},{"issue":"1","key":"5449_CR48","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1186\/s12891-017-1645-7","volume":"18","author":"P Zhang","year":"2017","unstructured":"Zhang P, Liang Y, He J, Fang Y, Chen P, Wang J. A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury. BMC Musculoskelet Disord. 2017;18(1):286. https:\/\/doi.org\/10.1186\/s12891-017-1645-7.","journal-title":"BMC Musculoskelet Disord."},{"key":"5449_CR49","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1186\/1471-2474-14-355","volume":"14","author":"Y Zhang","year":"2013","unstructured":"Zhang Y, Zhao X, Tang Y, Zhang C, Xu S, Xie Y. Application of Ni-Ti alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients. BMC Musculoskelet Disord. 2013;14:355. https:\/\/doi.org\/10.1186\/1471-2474-14-355.","journal-title":"BMC Musculoskelet Disord"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05449-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05449-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05449-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,19]],"date-time":"2022-05-19T11:24:47Z","timestamp":1652959487000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05449-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,19]]},"references-count":49,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5449"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05449-9","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,19]]},"assertion":[{"value":"16 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Ethics Committee of The First Affiliated Hospital of Naval Military Medical University approved the research project and analysis of the patient. Written informed consent to participants was obtained from all subjects and\/or their legal guardian(s) in ethical approval and consent to participants section.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participants"}},{"value":"All subjects or legal guardians signed an informed consent form, supporting and agreeing to the publication of relevant images and table data in the research.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"476"}}