{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T18:41:37Z","timestamp":1789411297460,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T00:00:00Z","timestamp":1653609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The axial headless compression screw (AHCS) technique is a widely used method for distal interphalangeal joint (DIPJ) and thumb IPJ arthrodesis. However, it might not be suitable for cases over 10\u00b0 flexion of fusion angle and extremely small-sized phalanx. Here, the authors describe the nonaxial multiple small screws (NMSS) technique, compare the mechanical strength of the NMSS technique with the AHCS technique, and suggest clinical outcomes of the NMSS technique.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>DIPJ and thumb IPJ arthrodesis models were simulated in the 4th generation composite bone hand. Fixation with three 1.5\u00a0mm cortical screws (NMSS) or one HCS (AHCS) was performed in each pair of the phalanx. The bending stiffness and load to failure were tested in 10 pairs of each specimen, and the torsional stiffness and torque to failure were tested in seven pairs of each specimen. Moreover, 15 consecutive clinical DIPJ and thumb IPJ arthrodesis cases were reviewed retrospectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The NMSS specimens showed significantly higher bending load to failure, torsional stiffness, and torque to failure than the AHCS specimens. All 15 arthrodesis cases were united without severe complications. The mean fusion angle was 16.3\u00b0 for the nine cases of the flexed target position.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The NMSS technique showed biomechanical stability comparable to that of the AHCS technique in DIPJ and thumb IPJ arthrodesis. Thus, the NMSS technique could be used as a feasible option in DIPJ and thumb IPJ arthrodesis, especially when a small finger is indicated and a significant flexion angle is required.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05473-9","type":"journal-article","created":{"date-parts":[[2022,5,27]],"date-time":"2022-05-27T08:03:57Z","timestamp":1653638637000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Distal interphalangeal joint arthrodesis with nonaxial multiple small screws: a biomechanical analysis with axial headless compression screw and clinical result of 15 consecutive cases"],"prefix":"10.1186","volume":"23","author":[{"given":"Seung Hun","family":"Woo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Ho","family":"Kwak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyo Seok","family":"Jang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Hee","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jang Hyeon","family":"Seo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sang Hyun","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,5,27]]},"reference":[{"key":"5473_CR1","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1007\/s12593-014-0163-1","volume":"6","author":"D Dickson","year":"2014","unstructured":"Dickson D, Mehta S, Nuttall D, Ng C. A systematic review of distal interphalangeal joint arthrodesis. J Hand Microsurg. 2014;6:74\u201384.","journal-title":"J Hand Microsurg"},{"key":"5473_CR2","doi-asserted-by":"publisher","first-page":"401","DOI":"10.4055\/cios.2014.6.4.401","volume":"6","author":"SH Han","year":"2014","unstructured":"Han SH, Cha YS, Song WT. Arthrodesis of distal interphalangeal joints in the hand with interosseous wiring and intramedullary K-wire fixation. Clin Orthop Surg. 2014;6:401\u20134.","journal-title":"Clin Orthop Surg"},{"key":"5473_CR3","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1055\/a-1559-2684","volume":"53","author":"J-K Lee","year":"2021","unstructured":"Lee J-K, Lee S, Choi S, et al. Distal interphalangeal Joint Arthrodesis using only Kirschner Wires in small distal Phalanges. Handchir Mikrochir Plast Chir. 2021;53:462\u20136.","journal-title":"Handchir Mikrochir Plast Chir"},{"key":"5473_CR4","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1016\/S0363-5023(96)80360-1","volume":"21","author":"B Wyrsch","year":"1996","unstructured":"Wyrsch B, Dawson J, Aufranc S, Weikert D, Milek M. Distal interphalangeal joint arthrodesis comparing tensionband wire and Herbert screw: a biomechanical and dimensional analysis. J Hand Surg Am. 1996;21:438\u201343.","journal-title":"J Hand Surg Am"},{"key":"5473_CR5","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1177\/1558944715627211","volume":"11","author":"SK Rigot","year":"2016","unstructured":"Rigot SK, Diaz-Garcia R, Debski RE, Fowler J. Biomechanical analysis of internal fixation methods for distal interphalangeal joint arthrodesis. Hand (N Y). 2016;11:221\u20136.","journal-title":"Hand (N Y)"},{"key":"5473_CR6","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1016\/j.jhsa.2012.03.018","volume":"37","author":"D Gruszka","year":"2012","unstructured":"Gruszka D, Burkhart K, Nowak T, Achenbach T, Rommens P, M\u00fcller L. The durability of the intrascaphoid compression of headless compression screws: in vitro study. J Hand Surg Am. 2012;37:1142\u201350.","journal-title":"J Hand Surg Am"},{"key":"5473_CR7","doi-asserted-by":"publisher","first-page":"1986","DOI":"10.1016\/j.jhsa.2014.06.021","volume":"39","author":"E Melamed","year":"2014","unstructured":"Melamed E, Polatsch DB, Beldner S, Melone CP Jr. Simulated distal interphalangeal joint fusion of the index and middle fingers in 0 and 20 of flexion: a comparison of grip strength and dexterity. J Hand Surg Am. 2014;39:1986\u201391.","journal-title":"J Hand Surg Am"},{"key":"5473_CR8","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1177\/1558944715614858","volume":"11","author":"S McGowan","year":"2016","unstructured":"McGowan S, Deisher M, Matullo KS. Functional fusion angle for thumb interphalangeal joint arthrodesis. Hand (N Y). 2016;11:59\u201364.","journal-title":"Hand (N Y)"},{"key":"5473_CR9","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1142\/S0218810417500149","volume":"22","author":"S Beecher","year":"2017","unstructured":"Beecher S, O\u2019Briain D, Ng J, Murphy E, O\u2019Sullivan M. Arthrodesis of little finger distal interphalangeal joint in flexion to regain sporting ability. J Hand Surg Asian Pac. 2017;22:83\u20137.","journal-title":"J Hand Surg Asian Pac"},{"key":"5473_CR10","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1007\/s00402-011-1413-3","volume":"132","author":"J-H Song","year":"2012","unstructured":"Song J-H, Lee J-Y, Chung Y-G, Park I-J. Distal interphalangeal joint arthrodesis with a headless compression screw: morphometric and functional analyses. Arch Orthop Trauma Surg. 2012;132:663\u20139.","journal-title":"Arch Orthop Trauma Surg"},{"key":"5473_CR11","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1007\/s11552-014-9679-x","volume":"10","author":"M Darowish","year":"2015","unstructured":"Darowish M, Brenneman R, Bigger J. Dimensional analysis of the distal phalanx with consideration of distal interphalangeal joint arthrodesis using a headless compression screw. Hand (N Y). 2015;10:100\u20134.","journal-title":"Hand (N Y)"},{"key":"5473_CR12","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/0266-7681(94)90168-6","volume":"19","author":"L Teoh","year":"1994","unstructured":"Teoh L, Yeo S, Singh I. Interphalangeal joint arthrodesis with oblique placement of an AO lag screw. J Hand Surg Am. 1994;19:208\u201311.","journal-title":"J Hand Surg Am"},{"key":"5473_CR13","doi-asserted-by":"publisher","first-page":"2360","DOI":"10.1016\/j.jhsa.2013.09.026","volume":"38","author":"T Iwamoto","year":"2013","unstructured":"Iwamoto T, Matsumura N, Sato K, Momohara S, Toyama Y, Nakamura T. An obliquely placed headless compression screw for distal interphalangeal joint arthrodesis. J Hand Surg Am. 2013;38:2360\u20134.","journal-title":"J Hand Surg Am"},{"key":"5473_CR14","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1097\/BTH.0000000000000189","volume":"22","author":"EA Newman","year":"2018","unstructured":"Newman EA, Orbay MC, Nunez FA, Nunez F. Minimally invasive proximal interphalangeal joint arthrodesis using headless screw: surgical technique. Tech Hand Up Extrem Surg. 2018;22:39\u201342.","journal-title":"Tech Hand Up Extrem Surg"},{"key":"5473_CR15","doi-asserted-by":"publisher","first-page":"1971","DOI":"10.1016\/j.jhsa.2014.07.035","volume":"39","author":"JT Capo","year":"2014","unstructured":"Capo JT, Melamed E, Shamian B, et al. Biomechanical evaluation of 5 fixation devices for proximal interphalangeal joint arthrodesis. J Hand Surg Am. 2014;39:1971\u20137.","journal-title":"J Hand Surg Am"},{"key":"5473_CR16","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1097\/BOT.0b013e31819df775","volume":"23","author":"MJ Gardner","year":"2009","unstructured":"Gardner MJ, Nork SE, Huber P, Krieg JC. Stiffness modulation of locking plate constructs using near cortical slotted holes: a preliminary study. J Orthop Trauma. 2009;23:281\u20137.","journal-title":"J Orthop Trauma"},{"key":"5473_CR17","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1097\/00005131-200410000-00006","volume":"18","author":"K Stoffel","year":"2004","unstructured":"Stoffel K, Stachowiak G, Forster T, G\u00e4chter A, Kuster M. Oblique screws at the plate ends increase the fixation strength in synthetic bone test medium. J Orthop Trauma. 2004;18:611\u20136.","journal-title":"J Orthop Trauma"},{"key":"5473_CR18","doi-asserted-by":"publisher","first-page":"2288","DOI":"10.1016\/j.jbiomech.2004.07.035","volume":"38","author":"K Kursa","year":"2005","unstructured":"Kursa K, Diao E, Lattanza L, Rempel D. In vivo forces generated by finger flexor muscles do not depend on the rate of fingertip loading during an isometric task. J Biomech. 2005;38:2288\u201393.","journal-title":"J Biomech"},{"key":"5473_CR19","doi-asserted-by":"publisher","first-page":"2569","DOI":"10.1002\/art.27584","volume":"62","author":"D Aletaha","year":"2010","unstructured":"Aletaha D, Neogi T, Silman AJ, et al. 2010 rheumatoid arthritis classification criteria: an American College of Rheumatology\/European League Against Rheumatism collaborative initiative. Arthritis Rheum. 2010;62:2569\u201381.","journal-title":"Arthritis Rheum"},{"key":"5473_CR20","doi-asserted-by":"crossref","unstructured":"Tang JB, Giddins G. Why and how to report surgeons\u2019 levels of expertise. J Hand Surg Eur Vol. 2016.","DOI":"10.1177\/1753193416641590"},{"key":"5473_CR21","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.jhsa.2004.07.016","volume":"30","author":"JJ Roth","year":"2005","unstructured":"Roth JJ, Auerbach DM. Fixation of hand fractures with bicortical screws. J Hand Surg Am. 2005;30:151\u20133.","journal-title":"J Hand Surg Am"},{"key":"5473_CR22","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.hcl.2019.01.003","volume":"35","author":"A Prsic","year":"2019","unstructured":"Prsic A, Friedrich JB. Postoperative Management and Rehabilitation of the Replanted or Revascularized Digit. Hand Clin. 2019;35:221\u20139.","journal-title":"Hand Clin"},{"issue":"1068\u201374","key":"5473_CR23","volume":"39","author":"D Mintalucci","year":"2014","unstructured":"Mintalucci D, Lutsky KF, Matzon JL, Rivlin M, Niver G, Beredjiklian PK. Distal interphalangeal joint bony dimensions related to headless compression screw sizes. J Hand Surg Am. 2014;39(1068\u201374): e1.","journal-title":"J Hand Surg Am"},{"key":"5473_CR24","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/S0268-0033(99)00016-9","volume":"14","author":"N Fowler","year":"1999","unstructured":"Fowler N, Nicol A. Measurement of external three-dimensional interphalangeal loads applied during activities of daily living. Clin Biomech (Bristol, Avon). 1999;14:646\u201352.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"5473_CR25","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/S0021-9290(99)00076-7","volume":"32","author":"K Faran","year":"1999","unstructured":"Faran K, Ichioka N, Trzeciak M, Han S, Medige J, Moy O. Effect of bone quality on the forces generated by compression screws. J Biomech. 1999;32:861\u20134.","journal-title":"J Biomech"},{"key":"5473_CR26","doi-asserted-by":"publisher","first-page":"1190","DOI":"10.2106\/00004623-199708000-00011","volume":"79","author":"E Toby","year":"1997","unstructured":"Toby E, Butler T, McCormack T, Jayaraman G. A comparison of fixation screws for the scaphoid during application of cyclical bending loads. J Bone Joint Surg Am. 1997;79:1190\u20137.","journal-title":"J Bone Joint Surg Am"}],"updated-by":[{"DOI":"10.1186\/s12891-023-06568-7","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2023,5,30]],"date-time":"2023-05-30T00:00:00Z","timestamp":1685404800000}}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05473-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05473-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05473-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,30]],"date-time":"2023-05-30T07:03:32Z","timestamp":1685430212000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05473-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,27]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["5473"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05473-9","relation":{"correction":[{"id-type":"doi","id":"10.1186\/s12891-023-06568-7","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,27]]},"assertion":[{"value":"10 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2023","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12891-023-06568-7","URL":"https:\/\/doi.org\/10.1186\/s12891-023-06568-7","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki and conducted with the approval of the institutional review board (IRB) of Pusan National University Yangsan Hospital (05\u20132021-097). All methods were performed in accordance with the relevant guidelines and regulations, and the need for patient approval was waived by the IRB of Pusan National University Yangsan Hospital.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"504"}}