{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T20:16:17Z","timestamp":1778703377727,"version":"3.51.4"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,6,27]],"date-time":"2022-06-27T00:00:00Z","timestamp":1656288000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,27]],"date-time":"2022-06-27T00:00:00Z","timestamp":1656288000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Tri-Service General Hospital, National Defense Medical Center","award":["MAB-108-040"],"award-info":[{"award-number":["MAB-108-040"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Many studies have been conducted to compare traditional trajectory (TT) and cortical bone trajectory (CBT) screws; however, how screw parameters affect the biomechanical properties of TT and CBT screws, and so their efficacy remains to be investigated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A finite element model was used to simulate screws with different trajectories, diameters, and lengths. Responses for implant and tissues at the adjacent and fixed segments were used as the comparison indices. The contact lengths and spanning areas of the inserted screws were defined and compared across the varieties.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The trajectory and diameter had a greater impact on the responses from the implant and tissues than the length. The CBT has shorter length than the TT; however, the contact length and supporting area of the CBT within the cortical bone were 19.6%. and 14.5% higher than those of the TT, respectively. Overall, the TT and CBT were equally effective at stabilizing the instrumented segment, except for bending and rotation. The CBT experienced less adjacent segment compensations than the TT. With the same diameter and length, the TT was considerably less stressed than the CBT, especially for flexion and extension.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The CBT may provide less stress at adjacent segments compared with the TT. The CBT may provide more stiffer in osteoporotic segments than the TT due to greater contact with cortical bone and a wider supporting base between the paired screws. However, both entry point and insertion trajectory of the CBT should be carefully executed to avoid vertebral breach and ensure a stable cone-screw purchase.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05477-5","type":"journal-article","created":{"date-parts":[[2022,6,27]],"date-time":"2022-06-27T04:02:38Z","timestamp":1656302558000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A parametric investigation on traditional and cortical bone trajectory screws for transpedicular fixation"],"prefix":"10.1186","volume":"23","author":[{"given":"Tzu-Tsao","family":"Chung","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chen-Lun","family":"Chu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dueng-Yuan","family":"Hueng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shang-Chih","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,6,27]]},"reference":[{"issue":"4","key":"5477_CR1","doi-asserted-by":"publisher","first-page":"95","DOI":"10.14531\/2018.4.95-106","volume":"15","author":"SV Makarevich","year":"2018","unstructured":"Makarevich SV. Historical aspects of transpedicular fixation of the spine: literature review. J Spine Surg. 2018;15(4):95\u2013106. https:\/\/doi.org\/10.14531\/2018.4.95-106.","journal-title":"J Spine Surg"},{"issue":"5","key":"5477_CR2","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.spinee.2008.07.008","volume":"9","author":"BG Santoni","year":"2009","unstructured":"Santoni BG, Hynes RA, McGilvray KC, Rodriguez-Canessa G, Lyons AS, Henson MAW, et al. Cortical bone trajectory for lumbar pedicle screws. Spine J. 2009;9(5):366\u201373.","journal-title":"Spine J"},{"issue":"3","key":"5477_CR3","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1111\/os.12185","volume":"7","author":"K Phan","year":"2015","unstructured":"Phan K, Hogan J, Maharaj M, Mobbs J, R, et al. Cortical bone trajectory for lumbar pedicle screw placement: a review of published reports. Orthop Surg. 2015;7(3):213\u201321. https:\/\/doi.org\/10.1111\/os.12185.","journal-title":"Orthop Surg"},{"issue":"4","key":"5477_CR4","doi-asserted-by":"publisher","first-page":"679","DOI":"10.21037\/jss.2017.11.03","volume":"3","author":"K Phan","year":"2017","unstructured":"Phan K, Ramachandran V, Tran TM, Shah KP, Fadhil M, Lackey A, et al. Systematic review of cortical bone trajectory versus pedicle screw techniques for lumbosacral spine fusion. J Spine Surg. 2017;3(4):679\u201388. https:\/\/doi.org\/10.21037\/jss.2017.11.03.","journal-title":"J Spine Surg"},{"issue":"44","key":"5477_CR5","doi-asserted-by":"publisher","first-page":"e27670","DOI":"10.1097\/MD.0000000000027670","volume":"100","author":"M Bielecki","year":"2021","unstructured":"Bielecki M, Kunert P, Balasa A, Kujawski S, Marchel A. Clinical and radiological results of treating lumbar spondylosis with cortical bone trajectory screws. Med (Baltimore). 2021;100(44):e27670. https:\/\/doi.org\/10.1097\/MD.0000000000027670.","journal-title":"Med (Baltimore)"},{"key":"5477_CR6","doi-asserted-by":"publisher","first-page":"e717","DOI":"10.1016\/j.wneu.2018.07.253","volume":"119","author":"HM Li","year":"2018","unstructured":"Li HM, Zhang RJ, Gao H, Jia CY, Xing T, Zhang JX, et al. Biomechanical fixation properties of the cortical bone trajectory in the osteoporotic lumbar spine. World Neurosurg. 2018;119:e717\u201327. https:\/\/doi.org\/10.1016\/j.wneu.2018.07.253.","journal-title":"World Neurosurg"},{"key":"5477_CR7","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1186\/s13018-015-0270-0","volume":"10","author":"H Oshino","year":"2015","unstructured":"Oshino H, Sakakibara T, Inaba T, Yoshikawa T, Kato T, Kasai Y. A biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation. J Orthop Surg Res. 2015;10:125. https:\/\/doi.org\/10.1186\/s13018-015-0270-0.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"5477_CR8","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1186\/s13018-019-1311-x","volume":"14","author":"T Zhang","year":"2019","unstructured":"Zhang T, Guo N, Chen T, Yan J, Zhao W, Xu G. Comparison of outcomes between cortical screws and traditional pedicle screws for lumbar interbody fusion: a systematic review and meta-analysis. J Orthop Surg Res. 2019;14(1):269. https:\/\/doi.org\/10.1186\/s13018-019-1311-x.","journal-title":"J Orthop Surg Res"},{"key":"5477_CR9","doi-asserted-by":"publisher","first-page":"8","DOI":"10.21037\/amj.2017.12.09","volume":"3","author":"ZH Feng","year":"2018","unstructured":"Feng ZH, Li XB, Tian NF, Sheng SR, Li YM, Phan K, et al. The technique of cortical bone trajectory screw fixation in spine surgery: a comprehensive literature review. AME Med J. 2018;3:8. https:\/\/doi.org\/10.21037\/amj.2017.12.09.","journal-title":"AME Med J"},{"issue":"8","key":"5477_CR10","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.16.00120","volume":"5","author":"ID Kaye","year":"2017","unstructured":"Kaye ID, Prasad SK, Vaccaro AR, Hilibrand AS. The cortical bone trajectory for pedicle screw insertion. JBJS Rev. 2017;5(8): e13. https:\/\/doi.org\/10.2106\/JBJS.RVW.16.00120.","journal-title":"JBJS Rev"},{"issue":"11","key":"5477_CR11","first-page":"6850","volume":"11","author":"P Rexiti","year":"2019","unstructured":"Rexiti P, Aierken G, Wang S, Abudurexiti T, Abuduwali N, Deng Q, et al. Anatomical research on strength of screw track fixation in novel cortical bone trajectory for osteoporosis lumbar spine. Am J Transl Res. 2019;11(11):6850\u20139.","journal-title":"Am J Transl Res"},{"key":"5477_CR12","doi-asserted-by":"publisher","first-page":"e98","DOI":"10.1016\/j.wneu.2019.05.241","volume":"130","author":"N Marengo","year":"2019","unstructured":"Marengo N, Matsukawa K, Monticelli M, Marco A, Paolo P, Fabio C, et al. Cortical bone trajectory screw placement accuracy with a patient-matched 3-dimensional printed guide in lumbar spinal surgery: a clinical study. World Neurosurg. 2019;130:e98-104. https:\/\/doi.org\/10.1016\/j.wneu.2019.05.241.","journal-title":"World Neurosurg"},{"key":"5477_CR13","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1016\/j.jocn.2018.10.131","volume":"61","author":"F Dayani","year":"2019","unstructured":"Dayani F, Chen YR, Johnson E, Deb S, Wu Y, Pham L, et al. Minimally invasive lumbar pedicle screw fixation using cortical bone trajectory \u2013 screw accuracy, complications, and learning curve in 100 screw placements. J Clin Neurosci. 2019;61:106\u201311. https:\/\/doi.org\/10.1016\/j.jocn.2018.10.131.","journal-title":"J Clin Neurosci"},{"key":"5477_CR14","first-page":"5","volume":"3","author":"I Gonchar","year":"2018","unstructured":"Gonchar I, Kotani Y, Iwasaki N. Comparison of modified cortical bone trajectory screw and pedicle screw for spinal reconstruction surgery. Clin Surg. 2018;3:5.","journal-title":"Clin Surg"},{"key":"5477_CR15","doi-asserted-by":"publisher","first-page":"e1468","DOI":"10.1016\/j.wneu.2019.03.121","volume":"126","author":"F Penner","year":"2019","unstructured":"Penner F, Marengo N, Ajello M, Petrone S, Cofano F, Veneziani Santonio F, et al. Preoperative 3D CT Planning for Cortical Bone Trajectory Screws: A RetrospectiveRadiological Cohort Study. World Neurosurg. 2019;126:e1468\u201374.","journal-title":"World Neurosurg"},{"key":"5477_CR16","doi-asserted-by":"publisher","first-page":"e98","DOI":"10.1016\/j.wneu.2019.05.241","volume":"130","author":"N Marengo","year":"2019","unstructured":"Marengo N, Matsukawa K, Monticelli M, Ajello M, Pacca P, Cofano F, et al. Cortical Bone Trajectory Screw Placement Accuracy with a Patient-Matched 3-Dimensional Printed Guide in Lumbar Spinal Surgery: A Clinical Study. World Neurosurg. 2019;130:e98\u2013104.","journal-title":"World Neurosurg"},{"issue":"5","key":"5477_CR17","doi-asserted-by":"publisher","first-page":"E276","DOI":"10.1097\/BRS.0b013e31828251f9","volume":"38","author":"WH Chuang","year":"2013","unstructured":"Chuang WH, Kuo YJ, Lin SC, Wang CW, Chen SH, Chen YJ, et al. Comparison among load-, ROM-, and displacement-controlled methods used in the lumbosacral nonlinear finite-element analysis. Spine. 2013;38(5):E276-285. https:\/\/doi.org\/10.1097\/BRS.0b013e31828251f9.","journal-title":"Spine"},{"issue":"13","key":"5477_CR18","doi-asserted-by":"publisher","first-page":"E775","DOI":"10.1097\/BRS.0b013e318290fb2e","volume":"38","author":"CY Chien","year":"2013","unstructured":"Chien CY, Tan CH, Lu TH, Lin SC, Chuang WH, Chiang MC, et al. Pretension effects of the dynesys cord on the tissue responses and screw-spacer behaviors of the lumbosacral construct with hybrid fixation. Spine. 2013;38(13):E775-782. https:\/\/doi.org\/10.1097\/BRS.0b013e318290fb2e.","journal-title":"Spine"},{"issue":"15","key":"5477_CR19","doi-asserted-by":"publisher","first-page":"E878","DOI":"10.1097\/BRS.0000000000000388","volume":"39","author":"CY Chien","year":"2014","unstructured":"Chien CY, Kuo YJ, Lin SC, Chuang WH. Luh YP (2014) Kinematic and mechanical comparisons of lumbar hybrid fixation using Dynesys and Cosmic systems. Spine. 2014;39(15):E878-884. https:\/\/doi.org\/10.1097\/BRS.0000000000000388.","journal-title":"Spine"},{"key":"5477_CR20","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1097\/00007632-198911000-00020","volume":"14","author":"I Yamamoto","year":"1989","unstructured":"Yamamoto I, Panjabi MM, Crisco T, Oxland T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine. 1989;14:1256\u201360.","journal-title":"Spine"},{"issue":"Suppl 2","key":"5477_CR21","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1007\/s00586-018-5599-8","volume":"27","author":"N Marengo","year":"2018","unstructured":"Marengo N, Berjano P, Cofano F, Ajello M, Zenga F, Pilloni G, et al. Cortical bone trajectory screws for circumferential arthrodesis in lumbar degenerative spine: clinical and radiological outcomes of 101 cases. Eur Spine J. 2018;27(Suppl 2):213\u201321.","journal-title":"Eur Spine J"},{"issue":"4","key":"5477_CR22","doi-asserted-by":"publisher","first-page":"164","DOI":"10.22603\/ssrr.1.2017-0006","volume":"1","author":"K Matsukawa","year":"2017","unstructured":"Matsukawa K, Yato Y. Lumbar pedicle screw fixation with cortical bone trajectory: A review from anatomical and biomechanical standpoints. Spine Surg Relat Res. 2017;1(4):164\u201373.","journal-title":"Spine Surg Relat Res"},{"key":"5477_CR23","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.jocn.2020.04.070","volume":"76","author":"S Petrone","year":"2020","unstructured":"Petrone S, Marengo N, Ajello M, Lavorato A, Penner F, Cofano F, et al. Cortical bone trajectory technique\u2019s outcomes and procedures for posterior lumbar fusion: A retrospective study. J Clin Neurosci. 2020;76:25\u201330.","journal-title":"J Clin Neurosci"},{"issue":"7","key":"5477_CR24","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1097\/BSD.0000000000000258","volume":"30","author":"K Matsukawa","year":"2017","unstructured":"Matsukawa K, Yato Y, Hynes RA, Imabayashi H, Hosogane N, Yoshihara Y, et al. Comparison of pedicle screw fixation strength among different transpedicular trajectories: a finite element study. Clin Spine Surg. 2017;30(7):301\u20137. https:\/\/doi.org\/10.1097\/BSD.0000000000000258.","journal-title":"Clin Spine Surg"},{"key":"5477_CR25","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1007\/s00701-016-2705-83","volume":"158","author":"K Matsukawa","year":"2016","unstructured":"Matsukawa K, Yato Y, Imabayashi H, Hosogane N, Abe Y, Asazuma T, et al. Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation? Acta Neurochir. 2016;158:465\u201371. https:\/\/doi.org\/10.1007\/s00701-016-2705-83.","journal-title":"Acta Neurochir"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05477-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05477-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05477-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,27]],"date-time":"2022-06-27T04:05:17Z","timestamp":1656302717000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05477-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,27]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5477"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05477-5","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,27]]},"assertion":[{"value":"19 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the ethics committee of the institutional review board of the Tri-Service General Hospital (Protocol number:106WFE0150134). Written informed consent was waived by the ethics committee of the Tri-Service General Hospital because of the retrospective review of healthy lumbar image with pseudonymization of patient\u2019s data. The study was operated according to the Declaration of Helsinki of 1964 and its later amendments.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors report no conflict of interest concerning the materials or methods used in this study or the findings specified in this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"612"}}