{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T19:25:50Z","timestamp":1791487550302,"version":"4.3.4"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,6,30]],"date-time":"2022-06-30T00:00:00Z","timestamp":1656547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,30]],"date-time":"2022-06-30T00:00:00Z","timestamp":1656547200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The most commonly used approach for distal radius fractures is the traditional Henry approach. However, it requires an intraoperative incision of the pronator quadratus (PQ) muscle, which results in a series of complications if the repair of the PQ fails.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Aim<\/jats:title>\n                <jats:p>The objective of this study was to investigate the efficacy of sparing the pronator quadratus for volar plating of the distal radius fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Seventy-six patients who suffered from distal radius fractures of types 23-B, 23-C1, and 23-C2 as per the AO Foundation and Orthopaedic Trauma Association (AO\/OTA) classification were treated with volar locking plate fixation using either the PQ muscle incision and repair (group A, <jats:italic>n<\/jats:italic>\u2009=\u200939) or the PQ muscle preservation approach (group B, <jats:italic>n<\/jats:italic>\u2009=\u200937). Intraoperative index, postoperative efficacy and complications of patients were recorded and evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>All patients were followed up for more than one year after surgery. All fractures achieved union. There were significant differences in mean operative time, mean intraoperative blood loss, and mean fracture healing time between the two groups. Still, there were no significant differences in limb function scores between the two groups at the 12-month postoperative follow-up. Outcomes assessed at 1\u00a0week, 1\u00a0month, and 3\u00a0months after surgery demonstrated significant differences in the mean range of motion and pain-related visual analog scale (VAS) between the two groups. As the range of motion and grip strength increased, the VAS scores decreased, and there was no significant difference between the two groups at 12\u00a0months postoperatively. Although tendon irritation and delayed carpal tunnel syndrome were more common in group A than in group B (7.6% vs. 0% and 5.1% vs. 0%, respectively), the differences were not statistically significant.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The modified Henry approach with sparing pronator quadratus muscle has no significant advantage in the range of wrist motion and upper limb function in the late stage. Nevertheless, the intraoperative placement of the plate under the pronator quadratus muscle can shorten the operation time, reduce intraoperative bleeding, reduce early postoperative pain, promote early activity, and improve the patient's quality of life. It is recommended that the pronator be preserved at the time of surgery.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05576-3","type":"journal-article","created":{"date-parts":[[2022,6,30]],"date-time":"2022-06-30T07:02:53Z","timestamp":1656572573000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Evaluation of sparing the pronator quadratus for volar plating of distal radius fractures: a retrospective clinical study"],"prefix":"10.1186","volume":"23","author":[{"given":"Xiaoxia","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiyu","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huaqiang","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erxat","family":"Kerem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cong","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiqi","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maimaitiaili","family":"Tusunniyazi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yimurang","family":"Hamiti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongwei","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,30]]},"reference":[{"key":"5576_CR1","doi-asserted-by":"publisher","first-page":"S15","DOI":"10.1097\/BOT.0000000000001829","volume":"34","author":"GG Via","year":"2020","unstructured":"Via GG, Roebke AJ, Julka A. Dorsal Approach for Dorsal Impaction Distal Radius Fracture\u2014Visualization, Reduction, and Fixation Made Simple. J Orthop Trauma. 2020;34:S15\u20136.","journal-title":"J Orthop Trauma"},{"issue":"5","key":"5576_CR2","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1053\/jhsu.2001.26322","volume":"26","author":"KC Chung","year":"2001","unstructured":"Chung KC, Spilson SV. The frequency and epidemiology of hand and forearm fractures in the United States. J hand surg. 2001;26(5):908\u201315.","journal-title":"J hand surg"},{"issue":"1","key":"5576_CR3","doi-asserted-by":"publisher","first-page":"28","DOI":"10.5435\/00124635-200501000-00005","volume":"13","author":"DW Smith","year":"2005","unstructured":"Smith DW, Henry MH. Volar fixed-angle plating of the distal radius. JAAOS-J Am Acad Orthop Surg. 2005;13(1):28\u201336.","journal-title":"JAAOS-J Am Acad Orthop Surg"},{"issue":"12","key":"5576_CR4","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1007\/s00402-018-3051-5","volume":"138","author":"S Quadlbauer","year":"2018","unstructured":"Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Sch\u00e4ttin S, Hausner T, Leixnering M. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Traum Su. 2018;138(12):1773\u201382.","journal-title":"Arch Orthop Traum Su"},{"issue":"3","key":"5576_CR5","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1302\/0301-620X.99B3.35819","volume":"99","author":"CE Plant","year":"2017","unstructured":"Plant CE, Parsons NR, Costa ML. Do radiological and functional outcomes correlate for fractures of the distal radius? Bone Joint J. 2017;99(3):376\u201382.","journal-title":"Bone Joint J"},{"issue":"2","key":"5576_CR6","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1302\/0301-620X.100B2.BJJ-2017-0358.R1","volume":"100","author":"EQ Pang","year":"2018","unstructured":"Pang EQ, Truntzer J, Baker L, Harris A, Gardner MJ, Kamal RN. Cost minimization analysis of the treatment of distal radial fractures in the elderly. Bone Joint J. 2018;100(2):205\u201311.","journal-title":"Bone Joint J"},{"issue":"3","key":"5576_CR7","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/S0363-5023(76)80039-1","volume":"1","author":"RK Johnson","year":"1976","unstructured":"Johnson RK, Shrewsbury MM. The pronator quadratus in motions and in stabilization of the radius and ulna at the distal radioulnar joint. J hand Surg. 1976;1(3):205\u20139.","journal-title":"J hand Surg"},{"issue":"3","key":"5576_CR8","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s00590-013-1193-2","volume":"24","author":"M Armangil","year":"2014","unstructured":"Armangil M, Bezirgan U, Ba\u015far\u0131r K, Bilen G, Demirta\u015f M, Bilgin SS. The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working? Eur J Orthop Surg Traumatol. 2014;24(3):335\u20139.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"2","key":"5576_CR9","first-page":"102","volume":"17","author":"GD Chloros","year":"2008","unstructured":"Chloros GD, Papadonikolakis A, Ginn S, Wiesler ER. Pronator quadratus space and compartment syndrome after low-energy fracture of the distal radius: a case report. J Surg Orthop Adv. 2008;17(2):102.","journal-title":"J Surg Orthop Adv"},{"issue":"6","key":"5576_CR10","doi-asserted-by":"publisher","first-page":"369","DOI":"10.5435\/00124635-200906000-00005","volume":"17","author":"LM Berglund","year":"2009","unstructured":"Berglund LM, Messer TM. Complications of volar plate fixation for managing distal radius fractures. JAAOS-J Am Acad Orthop Surg. 2009;17(6):369\u201377.","journal-title":"JAAOS-J Am Acad Orthop Surg"},{"issue":"3","key":"5576_CR11","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1097\/BOT.0b013e3182539333","volume":"27","author":"SH Hershman","year":"2013","unstructured":"Hershman SH, Immerman I, Bechtel C, Lekic N, Paksima N, Egol KA. The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures. J Orthop Trauma. 2013;27(3):130\u20133.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"5576_CR12","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s11751-017-0288-4","volume":"12","author":"MA Mulders","year":"2017","unstructured":"Mulders MA, Walenkamp MM, Bos FJ, Schep NW, Goslings JC. Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review. Strategies Trauma Limb Reconstr. 2017;12(3):181\u20138.","journal-title":"Strategies Trauma Limb Reconstr"},{"issue":"11","key":"5576_CR13","doi-asserted-by":"publisher","first-page":"2246","DOI":"10.1016\/j.jhsa.2014.07.043","volume":"39","author":"JK Kim","year":"2014","unstructured":"Kim JK, Park JS, Shin SJ, Bae H, Kim S. The effect of brachioradialis release during distal radius fracture fixation on elbow flexion strength and wrist function. J Hand Surg. 2014;39(11):2246\u201350.","journal-title":"J Hand Surg"},{"issue":"1","key":"5576_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s40001-015-0187-4","volume":"20","author":"S H\u00e4berle","year":"2015","unstructured":"H\u00e4berle S, Sandmann GH, Deiler S, Kraus TM, Fensky F, Torsiglieri T, Rondak I, Biberthaler P, St\u00f6ckle U, Siebenlist S. Pronator quadratus repair after volar plating of distal radius fractures or not? Results of a prospective randomized trial. Eur J Med Res. 2015;20(1):1\u20138.","journal-title":"Eur J Med Res"},{"issue":"3","key":"5576_CR15","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1007\/s00590-020-02804-1","volume":"31","author":"CK Goorens","year":"2021","unstructured":"Goorens CK, De Keyzer PB, Van Royen K, Provyn S, Goubau JF. Pronator quadratus repair after volar plate fixation in distal radial fractures: evaluation of the clinical and functional outcome and of the protective role on the flexor tendons\u2014a randomized controlled study. Eur J Orthop Surg Traumatol. 2021;31(3):541\u20138.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"03","key":"5576_CR16","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1055\/s-0034-1384744","volume":"3","author":"MS Feeney","year":"2014","unstructured":"Feeney MS, Wentorf F, Putnam MD. Simulation of altered excursion of the pronator quadratus. J wrist surg. 2014;3(03):198\u2013202.","journal-title":"J wrist surg"},{"issue":"3","key":"5576_CR17","doi-asserted-by":"publisher","first-page":"267","DOI":"10.4055\/cios.2014.6.3.267","volume":"6","author":"J Nho","year":"2014","unstructured":"Nho J, Gong HS, Song CH, Wi SM, Lee YH, Baek GH. Examination of the pronator quadratus muscle during hardware removal procedures after volar plating for distal radius fractures. Clin Orthop Surg. 2014;6(3):267\u201372.","journal-title":"Clin Orthop Surg"},{"issue":"8","key":"5576_CR18","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1016\/j.otsr.2020.06.003","volume":"106","author":"F Shi","year":"2020","unstructured":"Shi F, Ren L. Is pronator quadratus repair necessary to improve outcomes after volar plate fixation of distal radius fractures? A systematic review and meta-analysis. Orthop Traumatol Surg Res. 2020;106(8):1627\u201335.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"1","key":"5576_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-020-01942-w","volume":"15","author":"C Lu","year":"2020","unstructured":"Lu C, Liu W, Chang C, Shih C, Fu Y, Jupiter JB. A systematic review and meta-analysis of the pronator quadratus repair following volar plating of distal radius fractures. J Orthop Surg Res. 2020;15(1):1\u20139.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"5576_CR20","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.jhsa.2003.10.013","volume":"29","author":"JA Bertelli","year":"2004","unstructured":"Bertelli JA, Ghizoni MF. Reconstruction of C5 and C6 brachial plexus avulsion injury by multiple nerve transfers: spinal accessory to suprascapular, ulnar fascicles to biceps branch, and triceps long or lateral head branch to axillary nerve. J Hand Surg. 2004;29(1):131\u20139.","journal-title":"J Hand Surg"},{"issue":"9","key":"5576_CR21","doi-asserted-by":"publisher","first-page":"1868","DOI":"10.1016\/j.jhsa.2012.06.005","volume":"37","author":"CR Swigart","year":"2012","unstructured":"Swigart CR, Badon MA, Bruegel VL, Dodds SD. Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study. J Hand Surg. 2012;37(9):1868\u201373.","journal-title":"J Hand Surg"},{"issue":"1","key":"5576_CR22","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1007\/s00064-019-0601-0","volume":"32","author":"B Hohendorff","year":"2020","unstructured":"Hohendorff B, Unglaub F, Spies CK, M\u00fcller LP, Ries C. Refixierung des musculus pronator quadratus mit einem Teil des M.-brachioradialis-Ansatzes bei der palmaren Plattenosteosynthese einer distalen Radiusfraktur. Oper Orthop und Traumatol. 2020;32(1):82\u20136.","journal-title":"Oper Orthop und Traumatol"},{"issue":"4","key":"5576_CR23","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/BTH.0000000000000104","volume":"19","author":"A Kashir","year":"2015","unstructured":"Kashir A, Donnell T. A brachioradialis splitting approach sparing the pronator quadratus for volar plating of the distal radius. Tech Hand Up Extrem Surg. 2015;19(4):176\u201381.","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"4","key":"5576_CR24","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.main.2009.04.007","volume":"28","author":"C Dos Remedios","year":"2009","unstructured":"Dos Remedios C, Nebout J, Benlarbi H, Caremier E, Sam-Wing J, Beya R. Pr\u00e9servation du muscle carr\u00e9 pronateur dans les ost\u00e9osynth\u00e8ses des fractures de l\u2019extr\u00e9mit\u00e9 distale du radius par plaque palmaire verrouill\u00e9e. Technique chirurgicale Chir Main. 2009;28(4):224\u20139.","journal-title":"Technique chirurgicale Chir Main"},{"issue":"5","key":"5576_CR25","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1177\/1753193411424706","volume":"37","author":"N Heidari","year":"2012","unstructured":"Heidari N, Clement H, Kosuge D, Grechenig W, Tesch NP, Weinberg AM. Is sparing the pronator quadratus muscle possible in volar plating of the distal radius? J Hand Surg (Eur Vol). 2012;37(5):402\u20136.","journal-title":"J Hand Surg (Eur Vol)"},{"issue":"2","key":"5576_CR26","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1177\/1753193417745259","volume":"43","author":"PA Liverneaux","year":"2018","unstructured":"Liverneaux PA. The minimally invasive approach for distal radius fractures and malunions. J Hand Surg (Eur Vol). 2018;43(2):121\u201330.","journal-title":"J Hand Surg (Eur Vol)"},{"key":"5576_CR27","doi-asserted-by":"publisher","first-page":"S80","DOI":"10.1016\/j.hansur.2016.02.011","volume":"35","author":"P Liverneaux","year":"2016","unstructured":"Liverneaux P, Ichihara S, Facca S, Diaz JH. R\u00e9sultats de l\u2019ost\u00e9osynth\u00e8se par plaque ant\u00e9rieure et abord mini-invasif (MIPO) des fractures de l\u2019extr\u00e9mit\u00e9 distale du radius: mise au point. Hand Surg Rehabil. 2016;35:S80\u20135.","journal-title":"Hand Surg Rehabil"},{"issue":"2","key":"5576_CR28","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.main.2013.12.006","volume":"33","author":"P Rey","year":"2014","unstructured":"Rey P, Rochet S, Loisel F, Obert L. how to spare the pronator quadratus during MIPO of distal radius fractures by using a mini-volar plate. Chir Main. 2014;33(2):95\u20139.","journal-title":"Chir Main"},{"issue":"5","key":"5576_CR29","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1007\/s00266-013-0186-1","volume":"37","author":"M Salgarello","year":"2013","unstructured":"Salgarello M, Visconti G, Barone-Adesi L. Interlocking circumareolar suture with undyed polyamide thread: a personal experience. Aesthet Plast Surg. 2013;37(5):1061\u20132.","journal-title":"Aesthet Plast Surg"},{"issue":"11","key":"5576_CR30","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1016\/j.jhsa.2017.08.018","volume":"42","author":"H Huang","year":"2017","unstructured":"Huang H, Wang J, Chang M. Repair of pronator quadratus with partial muscle split and distal transfer for volar plating of distal radius fractures. J Hand Surg. 2017;42(11):931\u20135.","journal-title":"J Hand Surg"},{"issue":"6","key":"5576_CR31","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1097\/01.bot.0000177389.43178.e2","volume":"19","author":"DE Ruchelsman","year":"2005","unstructured":"Ruchelsman DE, Klugman JA, Madan SS, Chorney GS. Anterior dislocation of the radial head with fractures of the olecranon and radial neck in a young child: a Monteggia equivalent fracture-dislocation variant. J Orthop Trauma. 2005;19(6):428\u201331.","journal-title":"J Orthop Trauma"},{"issue":"5","key":"5576_CR32","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","volume":"21","author":"R Arora","year":"2007","unstructured":"Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21(5):316\u201322.","journal-title":"J Orthop Trauma"},{"issue":"12","key":"5576_CR33","first-page":"669","volume":"36","author":"SF Duncan","year":"2007","unstructured":"Duncan SF, Weiland AJ. Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. AMERICAN JOURNAL OF ORTHOPEDICS-BELLE MEAD-. 2007;36(12):669.","journal-title":"AMERICAN JOURNAL OF ORTHOPEDICS-BELLE MEAD-"},{"issue":"6","key":"5576_CR34","first-page":"714","volume":"73","author":"M Rampoldi","year":"2007","unstructured":"Rampoldi M, Marsico S. Complications of volar plating of distal radius fractures. Acta Orthop Belg. 2007;73(6):714.","journal-title":"Acta Orthop Belg"},{"issue":"1","key":"5576_CR35","doi-asserted-by":"publisher","first-page":"48","DOI":"10.4055\/jkoa.2012.47.1.48","volume":"47","author":"G Jung","year":"2012","unstructured":"Jung G, Cho C, Kim J. Anatomical study of the pronator quadratus muscle and comparison to fracture sites of the distal radius. Journal of the Korean Orthopaedic Association. 2012;47(1):48\u201353.","journal-title":"Journal of the Korean Orthopaedic Association"},{"key":"5576_CR36","doi-asserted-by":"publisher","first-page":"S3","DOI":"10.1016\/j.injury.2013.10.045","volume":"45","author":"G Gradl","year":"2014","unstructured":"Gradl G, Mielsch N, Wendt M, Falk S, Mittlmeier T, Gierer P, Gradl G. Intramedullary nail versus volar plate fixation of extra-articular distal radius fractures. Two year results of a prospective randomized trial. Injury. 2014;45:S3\u20138.","journal-title":"Injury"},{"key":"5576_CR37","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1016\/S0020-1383(16)30850-6","volume":"47","author":"G Gradl","year":"2016","unstructured":"Gradl G, Falk S, Mittlmeier T, Wendt M, Mielsch N, Gradl G. Fixation of intra-articular fractures of the distal radius using intramedullary nailing: a randomized trial versus palmar locking plates. Injury. 2016;47:S25\u201330.","journal-title":"Injury"},{"key":"5576_CR38","doi-asserted-by":"publisher","first-page":"S75","DOI":"10.1016\/j.hansur.2016.03.011","volume":"35","author":"J Pierrart","year":"2016","unstructured":"Pierrart J, Tordjman D, Ikeuchi N, Delgrande D, Gregory T, Masmejean E. L\u00e9sions nerveuses associ\u00e9es aux fractures de l\u2019extr\u00e9mit\u00e9 distale du radius. Hand Surgery and Rehabilitation. 2016;35:S75\u20139.","journal-title":"Hand Surgery and Rehabilitation"},{"issue":"01","key":"5576_CR39","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1055\/s-0041-1731329","volume":"11","author":"C Ki Goorens","year":"2022","unstructured":"Ki Goorens C, Debaenst N, Van Royen K, Provyn S, Goubau JF. Minimally Invasive Pronator Quadratus Sparing Approach versus Extended Flexor Carpi Radialis Approach with Pronator Quadratus Repair for Volar Plating in Distal Radial Fractures. Journal of Wrist Surgery. 2022;11(01):41\u20137.","journal-title":"Journal of Wrist Surgery"},{"issue":"1","key":"5576_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-020-03450-8","volume":"21","author":"K Fang","year":"2020","unstructured":"Fang K, Lin X, Liu X, Ke Q, Shi S, Dai Z. Do we need to suture the pronator quadratus muscle when we do open reduction and internal fixation for fracture of the distal radius. Bmc Musculoskel Dis. 2020;21(1):1\u20137.","journal-title":"Bmc Musculoskel Dis"},{"issue":"1","key":"5576_CR41","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1177\/1558944719840737","volume":"16","author":"J Sonntag","year":"2021","unstructured":"Sonntag J, Hern J, Woythal L, Branner U, Lange KH, Brorson S. The Pronator quadratus muscle after Volar plating: ultrasound evaluation of anatomical changes correlated to patient-reported clinical outcome. Hand. 2021;16(1):32\u20137.","journal-title":"Hand"},{"issue":"4","key":"5576_CR42","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1007\/s11552-014-9607-0","volume":"9","author":"D Marsland","year":"2014","unstructured":"Marsland D, Hobbs CM, Sauv\u00e9 PS. Volar locking plate fixation of distal radius fractures: use of an intra-operative \u2018carpal shoot through\u2019view to identify dorsal compartment and distal radioulnar joint screw penetration. Hand. 2014;9(4):516\u201321.","journal-title":"Hand"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05576-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05576-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05576-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,15]],"date-time":"2022-11-15T02:11:23Z","timestamp":1668478283000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05576-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,30]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["5576"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05576-3","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,30]]},"assertion":[{"value":"22 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was approved by the Ethics Committee of The First Affiliated Hospital of Xinjiang Medical University and carried out in accordance with the ethical standards set out in the Helsinki Declaration. Informed consent was received from all participating.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent is available for review by the Editor of this journal.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"625"}}