{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T13:01:03Z","timestamp":1784120463659,"version":"3.55.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T00:00:00Z","timestamp":1659571200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T00:00:00Z","timestamp":1659571200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Implant subsidence is an undesirable effect after anterior cervical discectomy and fusion (ACDF). We investigated the relation between the rate of implant subsidence and the ratio of the implant surface area to the surface area of the adjacent bone.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We operated 170 disc spaces in a group of 104 patients. Two types of implants were used: 1) PEEK (polyetheretherketone) cages and 2) titanium-coated (TC) PEEK cages. Patients were randomised to receive a specific implant using a randomisation table. All implants had a surface area of 1.61 cm<jats:sup>2<\/jats:sup>. Based on computed tomography images, bone surface areas were calculated for vertebral bodies immediately adjacent to the interbody implants. The implant-to-bone surface ratio was then calculated for each disc space. Implant subsidence was assessed over 12\u00a0months of follow-up, and associations between implant subsidence, the type of implant, and the implant-to-bone surface ratio were investigated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Twelve months after the surgery, computed tomography was performed on 86 patients (144 disc spaces). Furthermore, in 166 disc spaces and 102 patients, conventional radiographs were obtained.<\/jats:p>\n                <jats:p>Subsidence was observed in 21% of the examined intervertebral spaces, and it was more frequently associated with higher values of bone surface area and lower values of the implant-to-bone surface ratio. The type of implant (PEEK vs TC-PEEK cages) did not significantly influence the rate of implant subsidence.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Implant subsidence was significantly related to the value of a coefficient representing the ratio of the implant's surface area to the bone surface area of the adjacent vertebral bodies, with subsidence occurring significantly more rarely for coefficient values\u2009\u2265\u20090.37.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05698-8","type":"journal-article","created":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T11:06:13Z","timestamp":1659611173000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Subsidence following cervical discectomy and implant-to-bone ratio"],"prefix":"10.1186","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0673-1480","authenticated-orcid":false,"given":"Bartosz","family":"Godlewski","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6687-1517","authenticated-orcid":false,"given":"Adam","family":"Bebenek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maciej","family":"Dominiak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grzegorz","family":"Karpinski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Cieslik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1421-2050","authenticated-orcid":false,"given":"Tomasz","family":"Pawelczyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,4]]},"reference":[{"issue":"1","key":"5698_CR1","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1007\/s10143-017-0850-z","volume":"41","author":"KC Mende","year":"2018","unstructured":"Mende KC, Eicker SO, Weber F. Cage deviation in the subaxial cervical spine in relation to implant position in the sagittal plane. Neurosurg Rev. 2018;41(1):267\u201374. https:\/\/doi.org\/10.1007\/s10143-017-0850-z.","journal-title":"Neurosurg Rev"},{"key":"5698_CR2","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.jocn.2016.01.042","volume":"33","author":"JY Park","year":"2016","unstructured":"Park JY, Choi KY, Moon BJ, Hur H, Jang JW, Lee JK. Subsidence after single-level anterior cervical fusion with a stand-alone cage. J Clin Neurosci. 2016;33:83\u20138. https:\/\/doi.org\/10.1016\/j.jocn.2016.01.042.","journal-title":"J Clin Neurosci"},{"key":"5698_CR3","doi-asserted-by":"publisher","DOI":"10.1177\/2192568220963061","author":"HJ Jang","year":"2020","unstructured":"Jang HJ, Chin DK, Kim KH, Park JY. Does Graft Position Affect Subsidence After Anterior Cervical Discectomy and Fusion? Glob spine J Published online. 2020. https:\/\/doi.org\/10.1177\/2192568220963061.","journal-title":"Glob spine J Published online"},{"issue":"1","key":"5698_CR4","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s00701-019-04139-1","volume":"162","author":"T Obermueller","year":"2020","unstructured":"Obermueller T, Wagner A, Kogler L, Joerger AK, Lange N, Lehmberg J, Meyer B, Shiban E. Radiographic measurements of cervical alignment, fusion and subsidence after ACDF surgery and their impact on clinical outcome. Acta Neurochir (Wien). 2020;162(1):89\u201399. https:\/\/doi.org\/10.1007\/s00701-019-04139-1.","journal-title":"Acta Neurochir (Wien)"},{"key":"5698_CR5","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.jocn.2018.04.005","volume":"52","author":"B Godlewski","year":"2018","unstructured":"Godlewski B, Stachura K, Czepko RA, Banach M, Czepko R. Analysisis of changes in cervical spinal curvature and intervertebral disk space height following ACDF surgery in a group of 100 patients followed up to 12 months. J Clin Neurosci. 2018;52:92\u20139. https:\/\/doi.org\/10.1016\/j.jocn.2018.04.005.","journal-title":"J Clin Neurosci"},{"key":"5698_CR6","doi-asserted-by":"publisher","unstructured":"Youden WJ. Index for rating diagnosctic tests. Cancer. 1950;3(1):32-5. https:\/\/doi.org\/10.1002\/1097-0142(1950)3:1<32::aid-cncr2820030106>3.0.co;2-3","DOI":"10.1002\/1097-0142(1950)3:1<32::aid-cncr2820030106>3.0.co;2-3"},{"issue":"1","key":"5698_CR7","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1097\/01.ede.0000147512.81966.ba","volume":"16","author":"EF Schisterman","year":"2005","unstructured":"Schisterman EF, Perkins NJ, Liu A, Bondell H. Optimal cut-point and its corresponding Youden Index to discriminate individuals using pooled blood samples. Epidemiology. 2005;16(1):73\u201381. https:\/\/doi.org\/10.1097\/01.ede.0000147512.81966.ba.","journal-title":"Epidemiology"},{"issue":"7","key":"5698_CR8","doi-asserted-by":"publisher","first-page":"1374","DOI":"10.1007\/s00586-011-2131-9","volume":"21","author":"WJ Wu","year":"2012","unstructured":"Wu WJ, Jiang LS, Liang Y, Dai LY. Cage subsidence does not, but cervical lordosis improvement does affect the long-term results of anterior cervical fusion with stand-alone cage for degenerative cervical disc disease: a retrospective study. Eur Spine J. 2012;21(7):1374\u201382. https:\/\/doi.org\/10.1007\/s00586-011-2131-9.","journal-title":"Eur Spine J"},{"issue":"6","key":"5698_CR9","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.1007\/s00701-022-05217-7","volume":"164","author":"B Godlewski","year":"2022","unstructured":"Godlewski B, Bebenek A, Dominiak M, Karpinski G, Cieslik P, Pawelczyk T. PEEK versus titanium-coated PEEK cervical cages: fusion rate. Acta Neurochir (Wien). 2022;164(6):1501\u20137. https:\/\/doi.org\/10.1007\/s00701-022-05217-7.","journal-title":"Acta Neurochir (Wien)"},{"issue":"1","key":"5698_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13037-014-0043-4","volume":"8","author":"D Zajonz","year":"2014","unstructured":"Zajonz D, Franke AC, von der H\u00f6h N, Voelker A, Moche M, Gulow J, Heyde CE. Is the radiographic subsidence of stand-alone cages associated with adverse clinical outcomes after cervical spine fusion? An observational cohort study with 2-year follow-up outcome scoring. Patient Saf Surg. 2014;8(1):1\u20139. https:\/\/doi.org\/10.1186\/s13037-014-0043-4.","journal-title":"Patient Saf Surg"},{"issue":"12","key":"5698_CR11","doi-asserted-by":"publisher","first-page":"2832","DOI":"10.1007\/s00586-014-3725-9","volume":"24","author":"C Brenke","year":"2015","unstructured":"Brenke C, Dostal M, Scharf J, Wei\u00df C, Schmieder K, Barth M. Influence of cervical bone mineral density on cage subsidence in patients following stand-alone anterior cervical discectomy and fusion. Eur Spine J. 2015;24(12):2832\u201340. https:\/\/doi.org\/10.1007\/s00586-014-3725-9.","journal-title":"Eur Spine J"},{"issue":"1","key":"5698_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/BSD.0b013e31825bd26d","volume":"27","author":"IO Karikari","year":"2014","unstructured":"Karikari IO, Jain D, Owens TR, Gottfried O, Hodges TR, Nimjee SM, Bagley CA. Impact of subsidence on clinical outcomes and radiographic fusion rates in anterior cervical discectomy and fusion: a systematic review. J Spinal Disord Tech. 2014;27(1):1\u201310. https:\/\/doi.org\/10.1097\/BSD.0b013e31825bd26d.","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"5698_CR13","doi-asserted-by":"publisher","first-page":"447","DOI":"10.3171\/spi.2006.4.6.447","volume":"4","author":"K Schmieder","year":"2006","unstructured":"Schmieder K, Wolzik-Grossmann M, Pechlivanis I, Engelhardt M, Scholz M, Harders A. Subsidence of the wing titanium cage after anterior cervical interbody fusion: 2-year follow-up study. J Neurosurg Spine. 2006;4(6):447\u201353. https:\/\/doi.org\/10.3171\/spi.2006.4.6.447.","journal-title":"J Neurosurg Spine"},{"issue":"5","key":"5698_CR14","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1007\/s00586-003-0539-6","volume":"12","author":"E Gercek","year":"2003","unstructured":"Gercek E, Arlet V, Delisle J, Marchesi D. Subsidence of stand-alone cervical cages in anterior interbody fusion: warning. Eur Spine J. 2003;12(5):513\u20136. https:\/\/doi.org\/10.1007\/s00586-003-0539-6.","journal-title":"Eur Spine J"},{"issue":"6","key":"5698_CR15","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1007\/s00701-015-2388-6","volume":"157","author":"CH Lee","year":"2015","unstructured":"Lee CH, Kim KJ, Hyun SJ, Yeom JS, Jahng TA, Kim HJ. Subsidence as of 12 months after single-level anterior cervical inter-body fusion. Is it related to clinical outcomes? Acta Neurochir (Wien). 2015;157(6):1063\u20138. https:\/\/doi.org\/10.1007\/s00701-015-2388-6.","journal-title":"Acta Neurochir (Wien)"},{"key":"5698_CR16","doi-asserted-by":"publisher","first-page":"398396","DOI":"10.1155\/2014\/398396","volume":"2014","author":"JH Klingler","year":"2014","unstructured":"Klingler JH, Kr\u00fcger MT, Sircar R, Kogias E, Scholz C, Volz F, Scheiwe C, Hubbe U. PEEK Cages versus PMMA Spacers in Anterior Cervical Discectomy: Comparison of Fusion, Subsidence, Sagittal Alignment, and Clinical Outcome with a Minimum 1-Year Follow-Up. ScientificWorldJournal. 2014;2014:398396. https:\/\/doi.org\/10.1155\/2014\/398396.","journal-title":"ScientificWorldJournal"},{"issue":"6","key":"5698_CR17","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1080\/02688690500495109","volume":"19","author":"N Haden","year":"2005","unstructured":"Haden N, Latimer M, Seeley HM, Laing RJ. Loss of inter-vertebral disc height after anterior cervical discectomy. Br J Neurosurg. 2005;19(6):469\u201374. https:\/\/doi.org\/10.1080\/02688690500495109.","journal-title":"Br J Neurosurg"},{"key":"5698_CR18","doi-asserted-by":"publisher","unstructured":"Tom\u00e9-Bermejo F, Morales-Valencia JA, Moreno-P\u00e9rez J, Marfil-P\u00e9rez J, D\u00edaz-Domingues E, Pi\u00f1era AR, Alvarez. Degenerative Cervical Disc Disease: Long-term Changes in Sagittal Alignment and Their Clinical Implications After Cervical Interbody Fusion Cage Subsidence: A Prospective Study With Standalone Lordotic Tantalum Cages. Clin spine Surg. 2017;30(5):E648-55. https:\/\/doi.org\/10.1097\/BSD.0000000000000293.","DOI":"10.1097\/BSD.0000000000000293"},{"key":"5698_CR19","doi-asserted-by":"publisher","unstructured":"Shiban E, Gapon K, Wostrack M, Meyer B, Lehmberg J. Clinical and radiological outcome after anterior cervical discectomy and fusion with stand-alone empty polyetheretherketone (PEEK) cages. Acta Neurochir (Wien). 2016;158(2):349-55. https:\/\/doi.org\/10.1007\/s00701-015-2630-2.","DOI":"10.1007\/s00701-015-2630-2"},{"key":"5698_CR20","doi-asserted-by":"publisher","unstructured":"Kao TH, Wu CH, Chou YC, Chen H Te, Chen WH, Tsou HK. Risk factors for subsidence in anterior cervical fusion with stand-alone polyetheretherketone (PEEK) cages: a review of 82 cases and 182 levels. Arch Orthop Trauma Surg. 2014;134(10):1343-51. https:\/\/doi.org\/10.1007\/s00402-014-2047-z.","DOI":"10.1007\/s00402-014-2047-z"},{"key":"5698_CR21","doi-asserted-by":"publisher","unstructured":"Godlewski B, Dominiak M. Advantages and disadvantages of the use of varioius types of interbody implants in cervical spine surgery. Critical review of the literature. Ortop Traumatol Rehabil. 2020;22(4):213-20. https:\/\/doi.org\/10.5604\/01.3001.0014.3457.","DOI":"10.5604\/01.3001.0014.3457"},{"key":"5698_CR22","doi-asserted-by":"publisher","unstructured":"Barsa P, Suchomel P. Factors affecting sagittal malalignment due to cage subsidence in stand-alone cage assisted anterior cervical fusion. Eur Spine J. 2007;16(9):1395-400. https:\/\/doi.org\/10.1007\/s00586-006-0284-8.","DOI":"10.1007\/s00586-006-0284-8"},{"key":"5698_CR23","doi-asserted-by":"publisher","unstructured":"Yamagata T, Takami T, Uda T, Ikeda H, Nagata T, Sakamoto S, Tsuyuguchi N, Ohata K. Outcomes of contemporary use of rectangular titanium stand-alone cages in anterior cervical discectomy and fusion: cage subsidence and cervical alignment. J Clin Neurosci. 2012;19(12):1673-8. https:\/\/doi.org\/10.1016\/j.jocn.2011.11.043.","DOI":"10.1016\/j.jocn.2011.11.043"},{"key":"5698_CR24","doi-asserted-by":"publisher","unstructured":"Wang JC, McDonough, Endow KK, Delamarter RB. Increased fusion rates withs cervical plating for two-level anterior cervical discectomy and fusion. Spine (Phila Pa 1976). 2000;25(1):41-5. https:\/\/doi.org\/10.1097\/00007632-200001010-00009.","DOI":"10.1097\/00007632-200001010-00009"},{"key":"5698_CR25","doi-asserted-by":"publisher","unstructured":"Dai LY, Jiang LS. Anterior cervical fusion with interbody cage containing beta-tricalcium phosphate augmented with plate fixation: a prospective randomised study with 2-year follow-up. Eur Spine J. 2008;17:698-705. https:\/\/doi.org\/10.1007\/s00586-008-0643-8","DOI":"10.1007\/s00586-008-0643-8"},{"key":"5698_CR26","doi-asserted-by":"publisher","unstructured":"Soo AE, Olsson E, Lim M. Prediction of Cervical Endplate Size: One Size Does Not Fit All. Orthopedics. 2016;39(3):e526-31. https:\/\/doi.org\/10.3928\/01477447-20160427-11.","DOI":"10.3928\/01477447-20160427-11"},{"key":"5698_CR27","doi-asserted-by":"publisher","unstructured":"Lee YS, Kim YB, Park SW. Risk factors for post-operative subsidence of single-level anterior cervical discectomy and fusion: the significance of the preoperative cervical alignment. Spine (Phila Pa 1976). 2014;39(16):1280-7. https:\/\/doi.org\/10.1097\/BRS.0000000000000400.","DOI":"10.1097\/BRS.0000000000000400"},{"key":"5698_CR28","doi-asserted-by":"publisher","unstructured":"Lou J, Liu H, Rong X, Li H, Wang B, Gong Q. Geometry of inferior endplates of the cervical spine. Clin Neurol Neurosurg. 2016;142:132-6. https:\/\/doi.org\/10.1016\/j.clineuro.2016.01.027.","DOI":"10.1016\/j.clineuro.2016.01.027"},{"key":"5698_CR29","doi-asserted-by":"publisher","unstructured":"Cho DY, Lee WY, Sheu PC. Treatment of multilevel cervical fusion with cages. Surg Neurol. 2004;62(5):378-85. https:\/\/doi.org\/10.1016\/j.surneu.2004.01.021.","DOI":"10.1016\/j.surneu.2004.01.021"},{"key":"5698_CR30","doi-asserted-by":"publisher","unstructured":"Ritzel H, Amling M, P\u00f6sl M, Hahn M, Delling G. The thickness of human vertebral cortical bone and its changes in aging and osteoporosis: a histomorphometric analysis of the complete spinal column from thirty-seven autopsy specimens. J Bone Miner Res. 1997;12(1):89-95. https:\/\/doi.org\/10.1359\/jbmr.1997.12.1.89.","DOI":"10.1359\/jbmr.1997.12.1.89"},{"key":"5698_CR31","doi-asserted-by":"publisher","unstructured":"Yang JJ, Yu CH, Chang BS, Yeom JS, Lee JH, Lee CK. Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg. 2011;3(1):16-23. https:\/\/doi.org\/10.4055\/cios.2011.3.1.16.","DOI":"10.4055\/cios.2011.3.1.16"},{"key":"5698_CR32","doi-asserted-by":"publisher","unstructured":"Bartels RHMA, Donk RD, Feuth T. Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery. 2006;58(3):502-7. https:\/\/doi.org\/10.1227\/01.NEU.0000197258.30821.50","DOI":"10.1227\/01.NEU.0000197258.30821.50"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05698-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05698-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05698-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T11:07:26Z","timestamp":1659611246000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05698-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,4]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5698"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05698-8","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,4]]},"assertion":[{"value":"18 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study obtained ethical approval from the institutional ethics committee of Andrzej Frycz Modrzewski Cracow University in Cracow (Resolution 4\/2019) and was conducted in compliance with the Declaration of Helsinki. Written informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"750"}}