{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T20:22:24Z","timestamp":1791922944871,"version":"4.3.4"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,22]],"date-time":"2022-10-22T00:00:00Z","timestamp":1666396800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,22]],"date-time":"2022-10-22T00:00:00Z","timestamp":1666396800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100013317","name":"Shanxi Provincial Key Research and Development Project","doi-asserted-by":"publisher","award":["201903D421019"],"award-info":[{"award-number":["201903D421019"]}],"id":[{"id":"10.13039\/501100013317","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51805475"],"award-info":[{"award-number":["51805475"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Femoral neck fractures are a common traumatic injury. The removal of the internal fixation remains controversial, especially in terms of mechanical stability. Moreover, collapsed necrosis of the femoral head continues to occur after fracture healing. We believe that sclerotic cancellous bone (SCB) formation around the screw is associated with femoral head necrosis. We aimed to compare mechanical features before and after implant removal and determine the effect of SCB formation on stress distribution.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Cylindrical cancellous bone sections were collected from a relatively normal region and an SCB region of a necrotic femoral head, and their elastic moduli were measured. Four femoral finite element models were developed: a) femoral neck fracture healing with implants, b) fracture healing without implants, c) sclerosis around the screw with implants, and d) sclerosis around the screw without implants.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The maximum von Mises peak stresses of models a and b were 66.643\u2009MPa and 63.76\u2009MPa, respectively, and were concentrated in the upper lateral femur. The main stress was scattered at the lowest screw tail, femoral calcar region, and lateral femur shaft. Moreover, coronal plane strain throughout the screw paths near the femoral head in models a and b was mostly in the range of 1000\u20133000 \u03bc\u03b5. The maximum stress concentrations in models c and d were located at the lower femoral head and reached 91.199\u2009MPa and 78.019\u2009MPa, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The stresses in the sclerotic model around the cannulated screws are more concentrated on the femoral head than in the healing model without sclerotic bone. The overall stresses in the healing femoral neck fracture model were essentially unchanged before and after removal of the internal fixation.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05888-4","type":"journal-article","created":{"date-parts":[[2022,10,22]],"date-time":"2022-10-22T03:40:27Z","timestamp":1666410027000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Comparison of femoral mechanics before and after internal fixation removal and the effect of sclerosis on femoral stress: a finite element analysis"],"prefix":"10.1186","volume":"23","author":[{"given":"Yang","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjie","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoran","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaoxin","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjie","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huifeng","family":"Shao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuze","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziquan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pengcui","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaogang","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaochun","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5692-2897","authenticated-orcid":false,"given":"Wangping","family":"Duan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,10,22]]},"reference":[{"issue":"8","key":"5888_CR1","doi-asserted-by":"publisher","first-page":"1591","DOI":"10.1007\/s00198-019-05015-5","volume":"30","author":"T Maluta","year":"2019","unstructured":"Maluta T, Toso G, Negri S, Samaila E, Magnan B. Correlation between hip osteoarthritis and proximal femoral fracture site: could it be protective for intracapsular neck fractures? A retrospective study on 320 cases. Osteoporos Int. 2019;30(8):1591\u20136.","journal-title":"Osteoporos Int"},{"issue":"9","key":"5888_CR2","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1177\/0954411919856138","volume":"233","author":"S Samsami","year":"2019","unstructured":"Samsami S, Augat P, Rouhi G. Stability of femoral neck fracture fixation: a finite element analysis. Proc Inst Mech Eng H. 2019;233(9):892\u2013900.","journal-title":"Proc Inst Mech Eng H"},{"issue":"4","key":"5888_CR3","doi-asserted-by":"publisher","first-page":"297","DOI":"10.5435\/JAAOS-D-15-00661","volume":"25","author":"G Slobogean","year":"2017","unstructured":"Slobogean G, Stockton D, Zeng B, Wang D, Ma B, Pollak A. Femoral neck fractures in adults treated with internal fixation: a prospective multicenter Chinese cohort. J Am Acad Orthop Surg. 2017;25(4):297\u2013303.","journal-title":"J Am Acad Orthop Surg"},{"key":"5888_CR4","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.clinbiomech.2020.02.016","volume":"74","author":"L Zhou","year":"2020","unstructured":"Zhou L, Lin J, Huang A, Gan W, Zhai X, Sun K, et al. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: a biomechanical study. Clin Biomech (Bristol, Avon). 2020;74:103\u201310.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"5","key":"5888_CR5","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s00402-018-2896-y","volume":"138","author":"Y Weil","year":"2018","unstructured":"Weil Y, Qawasmi F, Liebergall M, Mosheiff R, Khoury A. Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures. Arch Orthop Trauma Surg. 2018;138(5):661\u20137.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"7","key":"5888_CR6","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1097\/BOT.0000000000001461","volume":"33","author":"J Hoffmann","year":"2019","unstructured":"Hoffmann J, Kellam J, Kumaravel M, Clark K, Routt M, Gary J. Is the cranial and posterior screw of the \"inverted triangle\" configuration for femoral neck fractures safe? J Orthop Trauma. 2019;33(7):331\u20134.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"5888_CR7","doi-asserted-by":"publisher","first-page":"13345","DOI":"10.1038\/s41598-017-13643-2","volume":"7","author":"J Ma","year":"2017","unstructured":"Ma J, He W, Zhao J, Kuang M, Bai H, Sun L, et al. Bone microarchitecture and biomechanics of the necrotic femoral head. Sci Rep. 2017;7(1):13345.","journal-title":"Sci Rep"},{"key":"5888_CR8","doi-asserted-by":"publisher","first-page":"106072","DOI":"10.1016\/j.cmpb.2021.106072","volume":"204","author":"A Mirulla","year":"2021","unstructured":"Mirulla A, Pinelli S, Zaffagnini S, Nigrelli V, Ingrassia T, Paolo S, et al. Numerical simulations on periprosthetic bone remodeling: a systematic review. Comput Methods Prog Biomed. 2021;204:106072.","journal-title":"Comput Methods Prog Biomed"},{"issue":"2","key":"5888_CR9","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1016\/j.jbiomech.2015.12.011","volume":"49","author":"E Cresswell","year":"2016","unstructured":"Cresswell E, Goff M, Nguyen T, Lee W, Hernandez C. Spatial relationships between bone formation and mechanical stress within cancellous bone. J Biomech. 2016;49(2):222\u20138.","journal-title":"J Biomech"},{"issue":"5","key":"5888_CR10","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1016\/j.jbiomech.2014.12.011","volume":"48","author":"T Morgan","year":"2015","unstructured":"Morgan T, Bostrom M, van der Meulen M. Tissue-level remodeling simulations of cancellous bone capture effects of in vivo loading in a rabbit model. J Biomech. 2015;48(5):875\u201382.","journal-title":"J Biomech"},{"key":"5888_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-64904-7_5","volume-title":"Femoral neck fractures in the Young: Proximal Femur Fractures","author":"EB Goudie","year":"2018","unstructured":"Goudie EB, Duckworth AD, White TO. Femoral neck fractures in the Young: Proximal Femur Fractures; 2018."},{"issue":"6","key":"5888_CR12","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1111\/os.13318","volume":"14","author":"Y Liu","year":"2022","unstructured":"Liu Y, Liang H, Zhou X, Song W, Shao H, He Y, et al. Micro-computed tomography analysis of femoral head necrosis after long-term internal fixation for femoral neck fracture. Orthop Surg. 2022;14(6):1186\u201392.","journal-title":"Orthop Surg"},{"issue":"5","key":"5888_CR13","doi-asserted-by":"publisher","first-page":"e96361","DOI":"10.1371\/journal.pone.0096361","volume":"9","author":"C Wang","year":"2014","unstructured":"Wang C, Wang X, Xu X, Yuan X, Gou W, Wang A, et al. Bone microstructure and regional distribution of osteoblast and osteoclast activity in the osteonecrotic femoral head. PLoS One. 2014;9(5):e96361.","journal-title":"PLoS One"},{"issue":"7","key":"5888_CR14","doi-asserted-by":"publisher","first-page":"1359","DOI":"10.1007\/s00590-018-2207-x","volume":"28","author":"V Giordano","year":"2018","unstructured":"Giordano V, Paes R, Alves D, Amaral A, Belangero W, Giordano M, et al. Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical study. Eur J Orthop Surg Traumatol. 2018;28(7):1359\u201367.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"5888_CR15","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.apergo.2017.04.008","volume":"63","author":"J Van Houcke","year":"2017","unstructured":"Van Houcke J, Schouten A, Steenackers G, Vandermeulen D, Pattyn C, Audenaert E. Computer-based estimation of the hip joint reaction force and hip flexion angle in three different sitting configurations. Appl Ergon. 2017;63:99\u2013105.","journal-title":"Appl Ergon"},{"key":"5888_CR16","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.jcot.2020.06.006","volume":"14","author":"A Freitas","year":"2021","unstructured":"Freitas A, Toledo J\u00fanior J, Ferreira dos Santos A, Aquino R, Le\u00e3o V, P\u00e9ricles de Alc\u00e2ntara W. Biomechanical study of different internal fixations in Pauwels type III femoral neck fracture - a finite elements analysis. J Clin Orthop Trauma. 2021;14:145\u201350.","journal-title":"J Clin Orthop Trauma"},{"issue":"1","key":"5888_CR17","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1186\/s13018-018-0970-3","volume":"13","author":"J Li","year":"2018","unstructured":"Li J, Wang M, Li L, Zhang H, Hao M, Li C, et al. Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures. J Orthop Surg Res. 2018;13(1):272.","journal-title":"J Orthop Surg Res"},{"issue":"4","key":"5888_CR18","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1177\/1120700019859842","volume":"30","author":"C Chang","year":"2020","unstructured":"Chang C, Tsai S, Wu P, Chen C, Chang M, Chen W, et al. Suboptimal outcomes after internal fixation for displaced intracapsular femoral neck fractures in 50- to 60-year-old patients. Hip Int. 2020;30(4):474\u201380.","journal-title":"Hip Int"},{"key":"5888_CR19","first-page":"477","volume":"06","author":"X Sun","year":"2012","unstructured":"Sun X, Zeng R, Hu Z, Guo W, Chen S, Wang B, et al. Femoral head necrosis after treatment of famoral neck fractures with compressive hollow screws. Chin J Orthop Trauma. 2012;06:477\u20139.","journal-title":"Chin J Orthop Trauma"},{"issue":"9","key":"5888_CR20","first-page":"1091","volume":"34","author":"K Chu","year":"2020","unstructured":"Chu K, Zhang X, Lu X, Chen X. Risk of micro-fracture in femoral head after removal of cannulated screws for femoral neck fracture. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2020;34(9):1091\u20135.","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"issue":"12","key":"5888_CR21","doi-asserted-by":"publisher","first-page":"e1117","DOI":"10.3928\/01477447-20141124-60","volume":"37","author":"T Wang","year":"2014","unstructured":"Wang T, Sun J, Zha G, Jiang T, You Z, Yuan D. Analysis of risk factors for femoral head necrosis after internal fixation in femoral neck fractures. Orthopedics. 2014;37(12):e1117\u201323.","journal-title":"Orthopedics"},{"issue":"9","key":"5888_CR22","doi-asserted-by":"publisher","first-page":"e285","DOI":"10.1097\/BOT.0000000000000358","volume":"29","author":"S Zielinski","year":"2015","unstructured":"Zielinski S, Heetveld M, Bhandari M, Patka P, Van Lieshout E. Implant removal after internal fixation of a femoral neck fracture: effects on physical functioning. J Orthop Trauma. 2015;29(9):e285\u201392.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"5888_CR23","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/1752-2897-6-6","volume":"6","author":"D Vos","year":"2012","unstructured":"Vos D, Hanson B, Verhofstad M. Implant removal of osteosynthesis: the Dutch practice. Results of a survey. J Trauma Manag Outcomes. 2012;6(1):6.","journal-title":"J Trauma Manag Outcomes"},{"issue":"2","key":"5888_CR24","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1111\/os.12458","volume":"11","author":"Y Wang","year":"2019","unstructured":"Wang Y, Ma J, Yin T, Han Z, Cui S, Liu Z, et al. Correlation between reduction quality of femoral neck fracture and femoral head necrosis based on biomechanics. Orthop Surg. 2019;11(2):318\u201324.","journal-title":"Orthop Surg"},{"issue":"06","key":"5888_CR25","first-page":"465","volume":"25","author":"X Ma","year":"2010","unstructured":"Ma X, Fu X, Ma J, Dong B, Shen M, Wang Z. Finite element study on spatial distribution and mechanical properties of cancellous bone from femoral head. Yi Yong Sheng Wu Li Xue. 2010;25(06):465\u201370.","journal-title":"Yi Yong Sheng Wu Li Xue"},{"key":"5888_CR26","doi-asserted-by":"publisher","first-page":"108658","DOI":"10.1016\/j.biopha.2019.108658","volume":"112","author":"L Tianye","year":"2019","unstructured":"Tianye L, Peng Y, Jingli X, QiuShi W, GuangQuan Z, Wei H, et al. Finite element analysis of different internal fixation methods for the treatment of Pauwels type III femoral neck fracture. Biomed Pharmacother. 2019;112:108658.","journal-title":"Biomed Pharmacother"},{"key":"5888_CR27","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.clinbiomech.2017.10.015","volume":"50","author":"I Levadnyi","year":"2017","unstructured":"Levadnyi I, Awrejcewicz J, Gubaua J, Pereira J. Numerical evaluation of bone remodelling and adaptation considering different hip prosthesis designs. Clin Biomech (Bristol, Avon). 2017;50:122\u20139.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"14","key":"5888_CR28","doi-asserted-by":"publisher","first-page":"2417","DOI":"10.1016\/j.jbiomech.2012.06.024","volume":"45","author":"H Wang","year":"2021","unstructured":"Wang H, Ji B, Liu X, Guo X, Huang Y, Hwang K. Analysis of microstructural and mechanical alterations of trabecular bone in a simulated three-dimensional remodeling process. J Biomech. 2021;45(14):2417\u201325.","journal-title":"J Biomech"},{"key":"5888_CR29","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.bone.2018.01.011","volume":"108","author":"X Zhang","year":"2018","unstructured":"Zhang X, Liu X, Yan Z, Cai J, Kang F, Shan S, et al. Spatiotemporal characterization of microdamage accumulation in rat ulnae in response to uniaxial compressive fatigue loading. Bone. 2018;108:156\u201364.","journal-title":"Bone"},{"issue":"3","key":"5888_CR30","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.orthres.2003.10.012","volume":"22","author":"M Vestermark","year":"2004","unstructured":"Vestermark M, Bechtold J, Swider P, S\u00f8balle K. Mechanical interface conditions affect morphology and cellular activity of sclerotic bone rims forming around experimental loaded implants. J Orthop Res. 2004;22(3):647\u201352.","journal-title":"J Orthop Res"},{"key":"5888_CR31","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.medengphy.2017.01.007","volume":"42","author":"PW Weng","year":"2017","unstructured":"Weng PW, Chen CH, Luo CA, Sun JS, Tsuang YH, Cheng CK, et al. The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: a finite element study. Med Eng Phys. 2017;42:48\u201354.","journal-title":"Med Eng Phys"},{"issue":"5","key":"5888_CR32","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1016\/j.jbiomech.2014.12.009","volume":"48","author":"D Webster","year":"2015","unstructured":"Webster D, Schulte F, Lambers F, Kuhn G, M\u00fcller R. Strain energy density gradients in bone marrow predict osteoblast and osteoclast activity: a finite element study. J Biomech. 2015;48(5):866\u201374.","journal-title":"J Biomech"},{"key":"5888_CR33","doi-asserted-by":"publisher","unstructured":"Metzger T, Kreipke T, Vaughan T, McNamara L, Niebur G. The in situ mechanics of trabecular bone marrow: the potential for mechanobiological response. J Biomech Eng. 2015;137(1). https:\/\/doi.org\/10.1115\/1.4028985.","DOI":"10.1115\/1.4028985"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05888-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05888-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05888-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,3]],"date-time":"2022-11-03T07:08:50Z","timestamp":1667459330000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05888-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,22]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["5888"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05888-4","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,22]]},"assertion":[{"value":"10 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki. Approval was granted by the Ethics Committee of Shanxi Medical University. Informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no relevant financial or non-financial interests to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"930"}}