{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T13:25:11Z","timestamp":1794317111024,"version":"4.9.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T00:00:00Z","timestamp":1667520000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T00:00:00Z","timestamp":1667520000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81472140"],"award-info":[{"award-number":["81472140"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006606","name":"Natural Science Foundation of Tianjin City","doi-asserted-by":"publisher","award":["S20ZDD484"],"award-info":[{"award-number":["S20ZDD484"]}],"id":[{"id":"10.13039\/501100006606","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>To analyse and compare the biomechanical differences between 3D-printed prostheses, titanium mesh cages and poorly matched titanium mesh cages in total en bloc spondylectomy (TES).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The finite element model of T10-L2 for healthy adults was modified to make three models after T12 total spondylectomy. These models were a 3D-printed prosthesis, titanium mesh cage and prosthesis-endplate mismatched titanium mesh cage for reconstruction. The range of motion (ROM), stress distribution of the endplate and internal fixation system of three models in flexion and extension, lateral bending and axial rotation were simulated and analysed by ABAQUS.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Result<\/jats:title>\n                <jats:p>In flexion, due to the support of the anterior prosthesis, the fixation system showed the maximum fixation strength. The fixation strength of the 3D-printed prosthesis model was 26.73\u00a0N\u00b7m \/\u00b0, that of the TMC support model was 27.20\u00a0N\u00b7m \/\u00b0, and that of the poorly matched TMC model was 24.16\u00a0N\u00b7m \/\u00b0. In flexion, the L1 upper endplate stress of the poorly matched TMC model was 35.5% and 49.6% higher than that of the TMC and 3D-printed prosthesis, respectively. It was 17% and 28.1% higher in extension, 39.3% and 42.5% higher in lateral bending, and 82.9% and 91.2% higher in axial rotation, respectively. The lower endplate of T11 showed a similar trend, but the magnitude of the stress change was reduced. In the stress analysis of the 3D-printed prosthesis and TMC, it was found that the maximum stress was in flexion and axial rotation, followed by left and right bending, and the least stress was in extension. However, the mismatched TMC withstood the maximum von Mises stress of 418.7\u00a0MPa (almost twice as much as the buckling state) in rotation, 3 times and 5.83 times in extension, and 1.29 and 2.85 times in lateral bending, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Different prostheses with good endplate matching after total spondylectomy can obtain effective postoperative stable support, and the reduction in contact area caused by mismatch will affect the biomechanical properties and increase the probability of internal fixation failure.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05919-0","type":"journal-article","created":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T04:26:51Z","timestamp":1667536011000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Biomechanical comparison of different prosthetic reconstructions in total en bloc spondylectomy: a finite element study"],"prefix":"10.1186","volume":"23","author":[{"given":"Hanpeng","family":"Xu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaodong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ye","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanyuan","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianzhong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Miao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,11,4]]},"reference":[{"issue":"24","key":"5919_CR1","doi-asserted-by":"publisher","first-page":"2783","DOI":"10.1097\/01.brs.0000192281.53603.3f","volume":"30","author":"T Akamaru","year":"2005","unstructured":"Akamaru T, Kawahara N, Sakamoto J, Yoshida A, Murakami H, Hato T, Awamori S, Oda J, Tomita K. The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis. Spine (Phila Pa 1976). 2005;30(24):2783\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"16","key":"5919_CR2","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1097\/00007632-199908150-00003","volume":"24","author":"I Oda","year":"1999","unstructured":"Oda I, Cunningham BW, Abumi K, Kaneda K, Mcafee PC. The stability of reconstruction methods after thoracolumbar total spondylectomy an in vitro investigation. Spine (Phila Pa 1976). 1999;24(16):1634\u20138.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"9","key":"5919_CR3","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.clinbiomech.2007.07.010","volume":"22","author":"AC Disch","year":"2007","unstructured":"Disch AC, Luzzati A, Melcher I, Schaser KD, Feraboli F, Schmoelz W. Three-dimensional stiffness in a thoracolumbar en-bloc spondylectomy model: a biomechanical in vitro study. Clin Biomech (Bristol, Avon). 2007;22(9):957\u201364.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"22","key":"5919_CR4","first-page":"324","volume":"1997","author":"K Tomita","year":"1976","unstructured":"Tomita K, Kawahara N, Baba H, Tsuchiya H, Fujita T, Toribatake Y. Total en bloc spondylectomy A new surgical technique for primary malignant vertebral tumors. (Spine Phila Pa). 1976;1997(22):324\u201333.","journal-title":"(Spine Phila Pa)"},{"key":"5919_CR5","doi-asserted-by":"publisher","first-page":"e87","DOI":"10.1016\/j.wneu.2019.05.037","volume":"129","author":"N Liu","year":"2019","unstructured":"Liu N, Lu T, Wang Y, Sun Z, Li J, He X. Effects of new cage profiles on the improvement in biomechanical performance of multilevel anterior cervical corpectomy and fusion: a finite element analysis. World Neurosurg. 2019;129:e87\u201396.","journal-title":"World Neurosurg"},{"key":"5919_CR6","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1016\/j.wneu.2017.05.133","volume":"105","author":"WJ Choy","year":"2017","unstructured":"Choy WJ, Mobbs RJ, Wilcox B, Phan S, Phan K, Sutterlin CR. Reconstruction of thoracic spine using a personalized 3D-printed vertebral body in adolescent with T9 primary bone tumor. World Neurosurg. 2017;105:1013\u201332.","journal-title":"World Neurosurg"},{"issue":"12","key":"5919_CR7","doi-asserted-by":"publisher","first-page":"3073","DOI":"10.1007\/s00586-018-5708-8","volume":"27","author":"M Girolami","year":"2018","unstructured":"Girolami M, Boriani S, Bandiera S, Barbanti-Brodano G, Ghermandi R, Terzi S, Tedesco G, Evangelisti G, Pipola V, Gasbarrini A. Biomimetic 3D-printed custom-made prosthesis for anterior column reconstruction in the thoracolumbar spine: a tailored option following en bloc resection for spinal tumors\u202f: preliminary results on a case-series of 13 patients. Eur Spine J. 2018;27(12):3073\u201383.","journal-title":"Eur Spine J"},{"key":"5919_CR8","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.wneu.2019.06.056","volume":"129","author":"BZ Chin","year":"2019","unstructured":"Chin BZ, Ji T, Tang X, Yang R, Guo W. Three-level lumbar en bloc spondylectomy with three-dimensional-printed vertebrae reconstruction for recurrent giant cell tumor. World Neurosurg. 2019;129:531\u20137.","journal-title":"World Neurosurg"},{"issue":"7","key":"5919_CR9","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/j.cad.2007.03.005","volume":"39","author":"DS Shin","year":"2007","unstructured":"Shin DS, Lee K, Kim D. Biomechanical study of lumbar spine with dynamic stabilization device using finite element method. Comput Aided Design. 2007;39(7):559\u201367.","journal-title":"Comput Aided Design"},{"issue":"1","key":"5919_CR10","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.medengphy.2005.03.007","volume":"28","author":"ZC Zhong","year":"2006","unstructured":"Zhong ZC, Wei SH, Wang JP, Feng CK, Chen CS, Yu CH. Finite element analysis of the lumbar spine with a new cage using a topology optimization method. Med Eng Phys. 2006;28(1):90\u20138.","journal-title":"Med Eng Phys"},{"issue":"4","key":"5919_CR11","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.clinbiomech.2006.11.008","volume":"22","author":"H Schmidt","year":"2007","unstructured":"Schmidt H, Heuer F, Drumm J, Klezl Z, Claes L, Wilke HJ. Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment. Clin Biomech (Bristol, Avon). 2007;22(4):377\u201384.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"11","key":"5919_CR12","doi-asserted-by":"publisher","first-page":"2414","DOI":"10.1016\/j.jbiomech.2006.11.021","volume":"40","author":"J Noailly","year":"2007","unstructured":"Noailly J, Wilke HJ, Planell JA, Lacroix D. How does the geometry affect the internal biomechanics of a lumbar spine bi-segment finite element model? Consequences on the validation process. J Biomech. 2007;40(11):2414\u201325.","journal-title":"J Biomech"},{"key":"5919_CR13","doi-asserted-by":"crossref","unstructured":"Eberlein R, Holzapfel GA, Fr Hlich M. Multi-segment FEA of the human lumbar spine including the heterogeneity of the annulus fibrosus. Comput Mech. 2004;34(2):147-163.","DOI":"10.1007\/s00466-004-0563-3"},{"issue":"1","key":"5919_CR14","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.clinbiomech.2009.09.010","volume":"25","author":"W Schmoelz","year":"2010","unstructured":"Schmoelz W, Schaser KD, Knop C, Blauth M, Disch AC. Extent of corpectomy determines primary stability following isolated anterior reconstruction in a thoracolumbar fracture model. Clin Biomech (Bristol, Avon). 2010;25(1):16\u201320.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"9","key":"5919_CR15","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1002\/jor.22376","volume":"31","author":"M Alizadeh","year":"2013","unstructured":"Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, Kamarul T. The use of X-shaped cross-link in posterior spinal constructs improves stability in thoracolumbar burst fracture: a finite element analysis. J Orthop Res. 2013;31(9):1447\u201354.","journal-title":"J Orthop Res"},{"issue":"13","key":"5919_CR16","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1080\/10255842.2019.1631286","volume":"22","author":"W Wang","year":"2019","unstructured":"Wang W, Pei B, Pei Y, Shi Z, Kong C, Wu X, Wu N, Fan Y, Lu S. Biomechanical effects of posterior pedicle fixation techniques on the adjacent segment for the treatment of thoracolumbar burst fractures: a biomechanical analysis. Comput Methods Biomech Biomed Engin. 2019;22(13):1083\u201392.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"5919_CR17","doi-asserted-by":"publisher","first-page":"105741","DOI":"10.1016\/j.cmpb.2020.105741","volume":"197","author":"E Dong","year":"2020","unstructured":"Dong E, Shi L, Kang J, Li D, Liu B, Guo Z, Wang L, Li X. Biomechanical characterization of vertebral body replacement in situ: Effects of different fixation strategies. Comput Meth Prog Bio. 2020;197:105741.","journal-title":"Comput Meth Prog Bio"},{"issue":"1","key":"5919_CR18","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1186\/s13018-021-02354-0","volume":"16","author":"X Wang","year":"2021","unstructured":"Wang X, Xu H, Han Y, Wu J, Song Y, Jiang Y, Wang J, Miao J. Biomechanics of artificial pedicle fixation in a 3D-printed prosthesis after total en bloc spondylectomy: a finite element analysis. J Orthop Surg Res. 2021;16(1):213.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"5919_CR19","doi-asserted-by":"publisher","first-page":"e1078","DOI":"10.1002\/jsp2.1078","volume":"3","author":"NB Bonnheim","year":"2020","unstructured":"Bonnheim NB, Keaveny TM. Load-transfer in the human vertebral body following lumbar total disc arthroplasty: Effects of implant size and stiffness in axial compression and forward flexion. JOR Spine. 2020;3(1):e1078.","journal-title":"JOR Spine"},{"key":"5919_CR20","doi-asserted-by":"publisher","first-page":"e581","DOI":"10.1016\/j.wneu.2017.12.127","volume":"111","author":"Z Zhang","year":"2018","unstructured":"Zhang Z, Li H, Fogel GR, Liao Z, Li Y, Liu W. Biomechanical analysis of porous additive manufactured cages for lateral lumbar interbody fusion: a finite element analysis. World Neurosurg. 2018;111:e581\u201391.","journal-title":"World Neurosurg"},{"issue":"2","key":"5919_CR21","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1227\/01.NEU.0000371987.85090.FF","volume":"67","author":"JM Cloyd","year":"2010","unstructured":"Cloyd JM, Acosta FJ, Polley MY, Ames CP. En bloc resection for primary and metastatic tumors of the spine: a systematic review of the literature. Neurosurg. 2010;67(2):435\u201344 (444-445).","journal-title":"Neurosurg."},{"key":"5919_CR22","doi-asserted-by":"publisher","first-page":"e371","DOI":"10.1016\/j.wneu.2018.11.172","volume":"123","author":"RP Zhou","year":"2019","unstructured":"Zhou RP, Mummaneni PV, Chen KY, Lau D, Cao K, Amara D, Zhang C, Dhall S, Chou D. Outcomes of posterior thoracic corpectomies for metastatic spine tumors: an analysis of 90 patients. World Neurosurg. 2019;123:e371\u20138.","journal-title":"World Neurosurg"},{"issue":"4","key":"5919_CR23","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1245\/s10434-013-3333-7","volume":"21","author":"S Kato","year":"2014","unstructured":"Kato S, Murakami H, Demura S, Yoshioka K, Kawahara N, Tomita K, Tsuchiya H. More than 10-year follow-up after total en bloc spondylectomy for spinal tumors. Ann Surg Oncol. 2014;21(4):1330\u20136.","journal-title":"Ann Surg Oncol"},{"key":"5919_CR24","doi-asserted-by":"publisher","first-page":"e106","DOI":"10.1016\/j.wneu.2019.11.057","volume":"135","author":"Z Li","year":"2020","unstructured":"Li Z, Wei F, Liu Z, Liu X, Jiang L, Yu M, Xu N, Wu F, Dang L, Zhou H, et al. Risk factors for instrumentation failure after total en bloc spondylectomy of thoracic and lumbar spine tumors Using titanium Mesh cage for anterior reconstruction. World Neurosurg. 2020;135:e106\u201315.","journal-title":"World Neurosurg"},{"key":"5919_CR25","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.wneu.2016.10.086","volume":"98","author":"S Boriani","year":"2017","unstructured":"Boriani S, Gasbarrini A, Bandiera S, Ghermandi R, Lador R. En bloc resections in the spine: the experience of 220 patients during 25 years. World Neurosurg. 2017;98:217\u201329.","journal-title":"World Neurosurg"},{"issue":"6","key":"5919_CR26","doi-asserted-by":"publisher","first-page":"446","DOI":"10.3928\/01477447-20100429-33","volume":"33","author":"S Kato","year":"2010","unstructured":"Kato S, Kawahara N, Murakami H, Demura S, Shirai T, Tsuchiya H, Tomita K. Multi-level total en bloc spondylectomy for solitary lumbar metastasis of myxoid liposarcoma. Orthopedics. 2010;33(6):446.","journal-title":"Orthopedics"},{"issue":"13","key":"5919_CR27","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1097\/01.BRS.0000129895.90939.1E","volume":"29","author":"R Pflugmacher","year":"2004","unstructured":"Pflugmacher R, Schleicher P, Schaefer J, Scholz M, Ludwig K, Khodadadyan-Klostermann C, Haas NP, Kandziora F. Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine. (Spine Phila Pa 1976). 2004;29(13):1413\u20139.","journal-title":"(Spine Phila Pa 1976)"},{"issue":"7","key":"5919_CR28","doi-asserted-by":"publisher","first-page":"E230","DOI":"10.1097\/01.brs.0000259232.30302.bf","volume":"32","author":"M Eskander","year":"2007","unstructured":"Eskander M, Brooks D, Ordway N, Dale E, Connolly P. Analysis of pedicle and translaminar facet fixation in a multisegment interbody fusion model. (Spine Phila Pa 1976). 2007;32(7):E230\u20135.","journal-title":"(Spine Phila Pa 1976)"},{"issue":"1","key":"5919_CR29","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3171\/spi.2004.1.1.0101","volume":"1","author":"SM Kim","year":"2004","unstructured":"Kim SM, Lim TJ, Paterno J, Kim DH. A biomechanical comparison of supplementary posterior translaminar facet and transfacetopedicular screw fixation after anterior lumbar interbody fusion. J Neurosurg Spine. 2004;1(1):101\u20137.","journal-title":"J Neurosurg Spine"},{"issue":"7","key":"5919_CR30","doi-asserted-by":"publisher","first-page":"1902","DOI":"10.1007\/s00586-016-4871-z","volume":"26","author":"R Wei","year":"2017","unstructured":"Wei R, Guo W, Ji T, Zhang Y, Liang H. One-step reconstruction with a 3D-printed, custom-made prosthesis after total en bloc sacrectomy: a technical note. Eur Spine J. 2017;26(7):1902\u20139.","journal-title":"Eur Spine J"},{"issue":"3","key":"5919_CR31","doi-asserted-by":"publisher","first-page":"320","DOI":"10.3171\/2011.5.SPINE10813","volume":"15","author":"M Matsumoto","year":"2011","unstructured":"Matsumoto M, Watanabe K, Tsuji T, Ishii K, Nakamura M, Chiba K, Toyama Y. Late instrumentation failure after total en bloc spondylectomy. J Neurosurg Spine. 2011;15(3):320\u20137.","journal-title":"J Neurosurg Spine"},{"issue":"17","key":"5919_CR32","doi-asserted-by":"publisher","first-page":"1070","DOI":"10.21037\/atm-19-4719","volume":"8","author":"F Wei","year":"2020","unstructured":"Wei F, Xu N, Li Z, Cai H, Zhou F, Yang J, Yu M, Liu X, Sun Y, Zhang K, et al. A prospective randomized cohort study on 3D-printed artificial vertebral body in single-level anterior cervical corpectomy for cervical spondylotic myelopathy. Ann Transl Med. 2020;8(17):1070.","journal-title":"Ann Transl Med"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05919-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05919-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05919-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,4]],"date-time":"2022-11-04T04:27:39Z","timestamp":1667536059000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05919-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,4]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["5919"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05919-0","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,4]]},"assertion":[{"value":"23 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 October 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethics Committee of Tianjin Hospital. All subjects signed informed consent by each patient. All clinical investigations had been conducted according to the principles expressed in the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent for publication was obtained from all participants.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"955"}}