{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T18:11:19Z","timestamp":1780337479600,"version":"3.54.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,29]],"date-time":"2022-11-29T00:00:00Z","timestamp":1669680000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,29]],"date-time":"2022-11-29T00:00:00Z","timestamp":1669680000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Comparison of 4 cannulated lag screws (3 inverted triangular cannulated screws\u2009+\u2009anti-rotating screws;4 CLS), dynamic hip screws\u2009+\u2009derotational screws (DHS\u2009+\u2009DS), and femoral neck fixation system (FNS) in the treatment of Biomechanical properties of middle-aged Pauwels type III femoral neck fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The femur CT data of a healthy young volunteer was selected and imported into Mimics software to construct a three-dimensional model of a normal femur. Pauwels type III femoral neck fractures were simulated according to the 70\u00b0 fracture line. Use Geomagic and SolidWorks software to optimize and build CLS, DHS\u2009+\u2009DS, and FNS fracture internal fixation models. Finally, Ansys software was used to analyze the stress distribution, peak value, and maximum displacement of the proximal fracture fragment and internal fixation; the displacement distribution, and peak value of the fracture surface at the fracture end.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>\u2460 The stress peaks of the proximal fracture fragments in the three groups were concentrated near the femoral calcar. The peak stress of the FNS group was the largest, and the DHS\u2009+\u2009DS group was the smallest. \u2461The displacement of the fracture fragments was all located at the top of the femur. The peak displacement of the FNS group was the largest, and the DHS\u2009+\u2009DS group was the smallest. \u2462 The internal fixation stress of the three groups is concentrated in the middle part of the device. The stress distribution of the first two groups of models is more uniform than that of FNS. The peak stress of FNS is the largest and the CLS is the smallest. \u2463 The internal fixed displacements are all located at the top of the model. The peak displacement of the CLS is the largest, and the DHS\u2009+\u2009DS is the smallest. \u2464 The displacement of the fracture surface is in the upper part of the fractured end. The peak displacement of the FNS group was the largest, and the DHS\u2009+\u2009DS group was the smallest.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Compared with the other two internal fixation methods, dynamic hip screw\u2009+\u2009derotational screw (DHS\u2009+\u2009DS) showed good biomechanical stability. When Pauwels type III femoral neck fracture occurs in young adults, DHS\u2009+\u2009DS can be given priority as the preferred treatment for this type of fracture.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-06003-3","type":"journal-article","created":{"date-parts":[[2022,11,29]],"date-time":"2022-11-29T07:38:25Z","timestamp":1669707505000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures"],"prefix":"10.1186","volume":"23","author":[{"given":"Ji","family":"Ma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziying","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaodong","family":"Zhi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,11,29]]},"reference":[{"issue":"1","key":"6003_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s00391-018-1382-z","volume":"52","author":"K Rapp","year":"2019","unstructured":"Rapp K, B\u00fcchele G, Dreinh\u00f6fer K, B\u00fccking B, Becker C, Benzinger P. Epidemiology of hip fractures: systematic literature review of german data and an overview of the international literature. Z Gerontol Geriatr. 2019;52(1):10\u20136.","journal-title":"Z Gerontol Geriatr"},{"issue":"Suppl 1","key":"6003_CR2","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1097\/BOT.0000000000001365","volume":"33","author":"P Augat","year":"2019","unstructured":"Augat P, Bliven E, Hackl S. Biomechanics of femoral Neck Fractures and Implications for fixation. J Orthop Trauma. 2019;33(Suppl 1):27\u201332.","journal-title":"J Orthop Trauma"},{"key":"6003_CR3","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1097\/BOT.0000000000001366","volume":"33 Suppl 1","author":"DS Chan","year":"2019","unstructured":"Chan DS. Femoral Neck Fractures in Young Patients: State of the Art. J Orthop Trauma. 2019;33 Suppl 1:S7\u201311.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"6003_CR4","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1097\/BOT.0000000000000836","volume":"31","author":"JP Johnson","year":"2017","unstructured":"Johnson JP, Borenstein TR, Waryasz GR, Klinge SA, McClure PK, Chambers AB, Hayda RA, Born CT. Vertically oriented femoral Neck Fractures: a Biomechanical comparison of 3 fixation constructs. J Orthop Trauma. 2017;31(7):363\u20138.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"6003_CR5","doi-asserted-by":"publisher","first-page":"673","DOI":"10.3944\/AOTT.2014.14.0088","volume":"48","author":"SA Gumustas","year":"2014","unstructured":"Gumustas SA, Tosun HB, Agir I, Orak MM, Onay T, Okcu G. Influence of number and orientation of screws on stability in the internal fixation of unstable femoral neck fractures. Acta Orthop Traumatol Turc. 2014;48(6):673\u20138.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"8","key":"6003_CR6","doi-asserted-by":"publisher","first-page":"2116","DOI":"10.1016\/j.injury.2021.05.043","volume":"52","author":"Z Fan","year":"2021","unstructured":"Fan Z, Huang Y, Su H, Jiang T. How to choose the suitable FNS specification in young patients with femoral neck fracture: a finite element analysis. Injury. 2021;52(8):2116\u201325.","journal-title":"Injury"},{"issue":"8","key":"6003_CR7","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1002\/jor.24881","volume":"39","author":"D Jiang","year":"2021","unstructured":"Jiang D, Zhan S, Wang L, Shi LL, Ling M, Hu H, Jia W. Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures. J Orthop Res. 2021;39(8):1669\u201380.","journal-title":"J Orthop Res"},{"issue":"9","key":"6003_CR8","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1080\/10255842.2020.1738404","volume":"23","author":"M Cordeiro","year":"2020","unstructured":"Cordeiro M, Caskey S, Frank C, Martin S, Srivastava A, Atkinson T. Hybrid triad provides fracture plane stability in a computational model of a Pauwels type III hip fracture. Comput Methods Biomech Biomed Engin. 2020;23(9):476\u201383.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"3","key":"6003_CR9","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","volume":"31","author":"K Stoffel","year":"2017","unstructured":"Stoffel K, Zderic I, Gras F, Sommer C, Eberli U, Mueller D, Oswald M, Gueorguiev B. Biomechanical evaluation of the femoral Neck System in Unstable Pauwels III femoral Neck Fractures: a comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma. 2017;31(3):131\u20137.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"6003_CR10","doi-asserted-by":"publisher","first-page":"e3459","DOI":"10.1002\/cnm.3459","volume":"37","author":"S Hamidi","year":"2021","unstructured":"Hamidi S, Khosravifard A, Hematiyan MR, Dehghani J. A comparative mechanical study of two types of femur bone implant using the finite element method. Int J Numer Method Biomed Eng. 2021;37(6):e3459.","journal-title":"Int J Numer Method Biomed Eng"},{"key":"6003_CR11","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.clinbiomech.2020.02.016","volume":"74","author":"L Zhou","year":"2020","unstructured":"Zhou L, Lin J, Huang A, Gan W, Zhai X, Sun K, Huang S, Li Z. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: a biomechanical study. Clin Biomech (Bristol Avon). 2020;74:103\u201310.","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"1","key":"6003_CR12","doi-asserted-by":"publisher","first-page":"61","DOI":"10.2106\/JBJS.K.01081","volume":"95","author":"J-J Yang","year":"2013","unstructured":"Yang J-J, Lin L-C, Chao K-H, Chuang S-Y, Wu C-C, Yeh T-T, Lian Y-T. Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration. J Bone Joint Surg Am. 2013;95(1):61\u20139.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"6003_CR13","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.injury.2020.02.075","volume":"51","author":"J Li","year":"2020","unstructured":"Li J, Wang M, Zhou J, Zhang H, Li L. Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures. Injury. 2020;51(4):995\u20131003.","journal-title":"Injury"},{"issue":"7","key":"6003_CR14","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1007\/s00590-010-0747-9","volume":"21","author":"O Filipov","year":"2011","unstructured":"Filipov O. Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck. Eur J Orthop Surg Traumatol. 2011;21(7):539\u201343.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"1","key":"6003_CR15","doi-asserted-by":"publisher","first-page":"112","DOI":"10.4103\/0019-5413.125541","volume":"48","author":"SR Biraris","year":"2014","unstructured":"Biraris SR, Soonawalla DF, Sonawane DV, Nemade PS. \u201cFour quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients. Indian J Orthop. 2014;48(1):112\u20133.","journal-title":"Indian J Orthop"},{"issue":"3","key":"6003_CR16","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1097\/00005131-199903000-00001","volume":"13","author":"JI Kauffman","year":"1999","unstructured":"Kauffman JI, Simon JA, Kummer FJ, Pearlman CJ, Zuckerman JD, Koval KJ. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical study. J Orthop Trauma. 1999;13(3):155\u20139.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"6003_CR17","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","volume":"90","author":"F Liporace","year":"2008","unstructured":"Liporace F, Gaines R, Collinge C, Haidukewych GJ. Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. J Bone Joint Surg Am. 2008;90(8):1654\u20139.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"6003_CR18","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1186\/s13018-018-0901-3","volume":"13","author":"Z Wang","year":"2018","unstructured":"Wang Z, Yin Y, Li Q, Sun G, Peng X, Yin H, Ye Y. Comparison of early complications between the use of a cannulated screw locking plate and multiple cancellous screws in the treatment of displaced intracapsular hip fractures in young adults: a randomized controlled clinical trial. J Orthop Surg Res. 2018;13(1):201.","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"6003_CR19","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1097\/BOT.0b013e31814b822e","volume":"21","author":"A Aminian","year":"2007","unstructured":"Aminian A, Gao F, Fedoriw WW, Zhang L-Q, Kalainov DM, Merk BR. Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques. J Orthop Trauma. 2007;21(8):544\u20138.","journal-title":"J Orthop Trauma"},{"issue":"10","key":"6003_CR20","doi-asserted-by":"publisher","first-page":"1017","DOI":"10.3390\/jpm11101017","volume":"11","author":"EJ Lim","year":"2021","unstructured":"Lim EJ, Shon HC, Cho JW, Oh JK, Kim J, Kim CH. Dynamic hip screw versus cannulated Cancellous Screw in Pauwels Type II or type III femoral Neck fracture: a systematic review and Meta-analysis. J Pers Med. 2021;11(10):1017.","journal-title":"J Pers Med"},{"issue":"11","key":"6003_CR21","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1007\/s00132-017-3473-8","volume":"46","author":"LL Zhang","year":"2017","unstructured":"Zhang LL, Zhang Y, Ma X, Liu Y. Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures: A meta-analysis. Orthopade. 2017;46(11):954\u201362.","journal-title":"Orthopade"},{"key":"6003_CR22","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.jcot.2020.06.006","volume":"14","author":"A Freitas","year":"2021","unstructured":"Freitas A, Toledo J\u00fanior JV, Ferreira dos Santos A, Aquino RJ, Le\u00e3o VN, P\u00e9ricles de Alc\u00e2ntara W. Biomechanical study of different internal fixations in Pauwels type III femoral neck fracture - A finite elements analysis. J Clin Orthop Trauma. 2021;14:145\u201350.","journal-title":"J Clin Orthop Trauma"},{"issue":"2","key":"6003_CR23","doi-asserted-by":"publisher","first-page":"196","DOI":"10.3944\/AOTT.2014.3159","volume":"48","author":"N Sa\u011flam","year":"2014","unstructured":"Sa\u011flam N, K\u00fc\u00e7\u00fckdurmaz F, Kivilcim H, Kurtulmu\u015f T, Sen C, Akpinar F. Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures. Acta Orthop Traumatol Turc. 2014;48(2):196\u2013201.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"5","key":"6003_CR24","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1007\/s40846-015-0085-9","volume":"35","author":"S Samsami","year":"2015","unstructured":"Samsami S, Saberi S, Sadighi S, Rouhi G. Comparison of three fixation methods for femoral Neck fracture in young adults: Experimental and Numerical Investigations. J Med Biol Eng. 2015;35(5):566\u201379.","journal-title":"J Med Biol Eng"},{"issue":"11","key":"6003_CR25","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","volume":"50","author":"J Li","year":"2019","unstructured":"Li J, Yin P, Zhang L, Chen H, Tang P. Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis. Injury. 2019;50(11):1895\u2013900.","journal-title":"Injury"},{"issue":"6","key":"6003_CR26","doi-asserted-by":"publisher","first-page":"1802","DOI":"10.1111\/os.13098","volume":"13","author":"XQ Zhou","year":"2021","unstructured":"Zhou XQ, Li ZQ, Xu RJ, She YS, Zhang XX, Chen GX, Yu X. Comparison of early clinical results for femoral Neck System and Cannulated Screws in the treatment of unstable femoral Neck Fractures. Orthop Surg. 2021;13(6):1802\u20139.","journal-title":"Orthop Surg"},{"issue":"4","key":"6003_CR27","doi-asserted-by":"publisher","first-page":"686","DOI":"10.1111\/os.13235","volume":"14","author":"YZ Zhang","year":"2022","unstructured":"Zhang YZ, Lin Y, Li C, Yue XJ, Li GY, Wang B, Wang YQ, Zhu ZQ. A comparative analysis of femoral Neck System and three cannulated screws fixation in the treatment of femoral Neck Fractures: a Six-Month Follow-Up. Orthop Surg. 2022;14(4):686\u201393.","journal-title":"Orthop Surg"},{"key":"6003_CR28","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.ijsu.2018.01.050","volume":"52","author":"JX Ma","year":"2018","unstructured":"Ma JX, Kuang MJ, Xing F, Zhao YL, Chen HT, Zhang LK, Fan ZR, Han C, Ma XL. Sliding hip screw versus cannulated cancellous screws for fixation of femoral neck fracture in adults: a systematic review. Int J Surg. 2018;52:89\u201397.","journal-title":"Int J Surg"},{"key":"6003_CR29","doi-asserted-by":"publisher","first-page":"106409","DOI":"10.1016\/j.cmpb.2021.106409","volume":"211","author":"Y Xia","year":"2021","unstructured":"Xia Y, Zhang W, Hu H, Yan L, Zhan S, Wang J. Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures - a finite element analysis. Comput Methods Programs Biomed. 2021;211:106409.","journal-title":"Comput Methods Programs Biomed"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-06003-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-06003-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-06003-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,29]],"date-time":"2022-11-29T19:04:41Z","timestamp":1669748681000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-06003-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,29]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["6003"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-06003-3","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,29]]},"assertion":[{"value":"12 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval and consent to participate: The study was approved by the Ethics Committee of the first affiliated hospital of Jinzhou medical university. This research was conducted in full compliance with the codes of ethical conduct from the Declaration of Helsinki. Written informed consent were obtained from the patients\u00a0before they were enrolled in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"No applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors declare no conflicts of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1030"}}