{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,25]],"date-time":"2026-02-25T12:42:34Z","timestamp":1772023354180,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,21]],"date-time":"2023-01-21T00:00:00Z","timestamp":1674259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,21]],"date-time":"2023-01-21T00:00:00Z","timestamp":1674259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>A consensus regarding the optimal approach for treating femoral neck fractures is lacking. We aimed to investigate the biomechanical outcomes of Femoral Neck System (FNS) internal fixation components in the treatment of nonanatomically reduced femoral neck fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Method<\/jats:title>\n                <jats:p>We constructed two types of femoral neck fractures of the Pauwels classification with angles of 30\u00b0 and 50\u00b0, and three models of anatomic reduction, positive buttress reduction and negative buttress reduction were constructed. Subgroups of 1 to 4\u00a0mm were divided according to the distance of displacement in the positive buttress reduction and negative buttress reduction models. The von Mises stress and displacements of the femur and FNS internal fixation components were measured for each fracture group under 2100-N axial loads.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>When the Pauwels angle was 30\u00b0, the positive 1-mm and 2-mm models had lower FNS stress than the negative buttress model. The positive 3- and 4-mm models showed FNS stress similar to that of the negative buttress model. But the four positive buttress models had similar stresses on the femur as the negative buttress model. When the Pauwels angle was 50\u00b0, the four positive buttress models had higher FNS stress than the negative buttress model. Three positive buttress models (2\u00a0mm, 3 and 4\u00a0mm) resulted in lower stress of the femur than the negative buttress model, though the 1-mm model did not. When the Pauwels angle was 30\u00b0, the positive buttress model had a lower displacement of the FNS than the negative buttress model and a similar displacement of the femur with the negative buttress model. When the Pauwels angle was 50\u00b0, the positive buttress model had a higher displacement of the FNS and femur than the negative buttress model. Our study also showed that the von Mises stress and displacement of the internal fixation and the femur increased as the fracture angle increased.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>From the perspective\nof biomechanics, when the Pauwels angle was 30\u00b0, positive buttress was more\nstable to negative buttress. However, when the Pauwels angle was 50\u00b0, this advantage weakens.\nIn our opinion, the clinical efficacy of FNS internal fixation with positive\nbuttress may be related to the fracture angle, neck-shaft angle and alignment\nin the lateral view. This result needs verification in further clinical\nstudies.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-06124-9","type":"journal-article","created":{"date-parts":[[2023,1,21]],"date-time":"2023-01-21T10:02:59Z","timestamp":1674295379000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element"],"prefix":"10.1186","volume":"24","author":[{"given":"Zhirong","family":"Fan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ping","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiubing","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xing","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haitao","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haiyun","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bing","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ji","family":"Qi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haizhou","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,1,21]]},"reference":[{"key":"6124_CR1","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1007\/PL00004148","volume":"7","author":"B Gullberg","year":"1997","unstructured":"Gullberg B, Johnell O, Kanis JA. World-wide projections for hip fracture. Osteoporos Int. 1997;7:407\u201313.","journal-title":"Osteoporos Int"},{"key":"6124_CR2","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1007\/s00198-004-1627-0","volume":"15","author":"O Johnell","year":"2004","unstructured":"Johnell O, Kanis JA. An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int. 2004;15:897\u2013902.","journal-title":"Osteoporos Int"},{"key":"6124_CR3","doi-asserted-by":"publisher","first-page":"2527","DOI":"10.1007\/s00198-011-1888-3","volume":"23","author":"RO Stoen","year":"2012","unstructured":"Stoen RO, Nordsletten L, Meyer HE, Frihagen JF, Falch JA, Lofthus CM. Hip fracture incidence is decreasing in the high incidence area of Oslo, Norway. Osteoporos Int. 2012;23:2527\u201334.","journal-title":"Osteoporos Int"},{"key":"6124_CR4","doi-asserted-by":"publisher","first-page":"2122","DOI":"10.2106\/JBJS.E.00535","volume":"87","author":"M Bhandari","year":"2005","unstructured":"Bhandari M, Devereaux PJ, Tornetta P 3rd, Swiontkowski MF, Berry DJ, Haidukewych G, et al. Operative management of displaced femoral neck fractures in elderly patients. An international survey. J Bone Joint Surg Am. 2005;87:2122\u201330.","journal-title":"J Bone Joint Surg Am"},{"key":"6124_CR5","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/j.injury.2014.11.028","volume":"46","author":"GP Slobogean","year":"2015","unstructured":"Slobogean GP, Sprague SA, Scott T, McKee M, Bhandari M. Management of young femoral neck fractures: is there a consensus? Injury. 2015;46:435\u201340.","journal-title":"Injury"},{"key":"6124_CR6","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","volume":"46","author":"GP Slobogean","year":"2015","unstructured":"Slobogean GP, Sprague SA, Scott T, Bhandari M. Complications following young femoral neck fractures. Injury. 2015;46:484\u201391.","journal-title":"Injury"},{"key":"6124_CR7","doi-asserted-by":"publisher","first-page":"54","DOI":"10.3109\/17453674.2013.765639","volume":"84","author":"AN Al-Ani","year":"2013","unstructured":"Al-Ani AN, Neander G, Samuelsson B, Blomfeldt R, Ekstrom W, Hedstrom M. Risk factors for osteoporosis are common in young and middle-aged patients with femoral neck fractures regardless of trauma mechanism. Acta Orthop. 2013;84:54\u20139.","journal-title":"Acta Orthop"},{"key":"6124_CR8","doi-asserted-by":"publisher","first-page":"61","DOI":"10.2106\/JBJS.K.01081","volume":"95","author":"JJ Yang","year":"2013","unstructured":"Yang JJ, Lin LC, Chao KH, Chuang SY, Wu CC, Yeh TT, et al. Risk factors for nonunion in patients with intracapsular femoral neck fractures treated with three cannulated screws placed in either a triangle or an inverted triangle configuration. J Bone Joint Surg Am. 2013;95:61\u20139.","journal-title":"J Bone Joint Surg Am"},{"key":"6124_CR9","doi-asserted-by":"publisher","first-page":"873","DOI":"10.3928\/01477447-20101021-15","volume":"33","author":"HK Huang","year":"2010","unstructured":"Huang HK, Su YP, Chen CM, Chiu FY, Liu CL. Displaced femoral neck fractures in young adults treated with closed reduction and internal fixation. Orthopedics. 2010;33:873.","journal-title":"Orthopedics"},{"key":"6124_CR10","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.2106\/00004623-200408000-00015","volume":"86","author":"GJ Haidukewych","year":"2004","unstructured":"Haidukewych GJ, Rothwell WS, Jacofsky DJ, Torchia ME, Berry DJ. Operative treatment of femoral neck fractures in patients between the ages of fifteen and fifty years. J Bone Joint Surg Am. 2004;86:1711\u20136.","journal-title":"J Bone Joint Surg Am"},{"key":"6124_CR11","doi-asserted-by":"publisher","first-page":"1519","DOI":"10.1016\/S0140-6736(17)30066-1","volume":"389","author":"Fixation using Alternative Implants for the Treatment of Hip fractures I","year":"2017","unstructured":"Fixation using Alternative Implants for the Treatment of Hip fractures I. Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial. Lancet. 2017;389:1519\u201327.","journal-title":"Lancet"},{"key":"6124_CR12","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","volume":"31","author":"K Stoffel","year":"2017","unstructured":"Stoffel K, Zderic I, Gras F, Sommer C, Eberli U, Mueller D, et al. Biomechanical evaluation of the femoral Neck System in Unstable Pauwels III femoral Neck Fractures: a comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma. 2017;31:131\u20137.","journal-title":"J Orthop Trauma"},{"key":"6124_CR13","doi-asserted-by":"publisher","first-page":"2116","DOI":"10.1016\/j.injury.2021.05.043","volume":"52","author":"Z Fan","year":"2021","unstructured":"Fan Z, Huang Y, Su H, Jiang T. How to choose the suitable FNS specification in young patients with femoral neck fracture: a finite element analysis. Injury. 2021;52:2116\u201325.","journal-title":"Injury"},{"key":"6124_CR14","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1111\/os.12458","volume":"11","author":"Y Wang","year":"2019","unstructured":"Wang Y, Ma JX, Yin T, Han Z, Cui SS, Liu ZP, et al. Correlation between reduction quality of femoral Neck fracture and femoral Head Necrosis based on Biomechanics. Orthop Surg. 2019;11:318\u201324.","journal-title":"Orthop Surg"},{"key":"6124_CR15","doi-asserted-by":"publisher","first-page":"2588","DOI":"10.1097\/CM9.0000000000000490","volume":"132","author":"G Wang","year":"2019","unstructured":"Wang G, Wang B, Tang Y, Yang HL. A quantitative biomechanical study of positive buttress techniques for femoral neck fractures: a finite element analysis. Chin Med J (Engl). 2019;132:2588\u201393.","journal-title":"Chin Med J (Engl)"},{"key":"6124_CR16","doi-asserted-by":"publisher","first-page":"e254-9","DOI":"10.1097\/BOT.0b013e31828f8ffc","volume":"27","author":"Y Gotfried","year":"2013","unstructured":"Gotfried Y, Kovalenko S, Fuchs D. Nonanatomical reduction of displaced subcapital femoral fractures (gotfried reduction). J Orthop Trauma. 2013;27:e254-9.","journal-title":"J Orthop Trauma"},{"key":"6124_CR17","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1016\/j.gendis.2019.04.006","volume":"7","author":"H Lu","year":"2020","unstructured":"Lu H, Shen H, Zhou S, Ni W, Jiang D. Biomechanical analysis of the computer-assisted internal fixation of a femoral neck fracture. Genes Dis. 2020;7:448\u201355.","journal-title":"Genes Dis"},{"key":"6124_CR18","doi-asserted-by":"publisher","first-page":"842","DOI":"10.1186\/s12891-020-03853-7","volume":"21","author":"S Zhan","year":"2020","unstructured":"Zhan S, Jiang D, Xu J, Ling M, Yang K, Li Y, et al. Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis. BMC Musculoskelet Disord. 2020;21:842.","journal-title":"BMC Musculoskelet Disord"},{"key":"6124_CR19","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1097\/00005131-200106000-00009","volume":"15","author":"J Bartonicek","year":"2001","unstructured":"Bartonicek J. Pauwels\u2019 classification of femoral neck fractures: correct interpretation of the original. J Orthop Trauma. 2001;15:358\u201360.","journal-title":"J Orthop Trauma"},{"key":"6124_CR20","doi-asserted-by":"publisher","first-page":"e221-5","DOI":"10.1097\/BOT.0000000000000080","volume":"28","author":"K Luttrell","year":"2014","unstructured":"Luttrell K, Beltran M, Collinge CA. Preoperative decision making in the treatment of high-angle \u201cvertical\u201d femoral neck fractures in young adult patients. An expert opinion survey of the Orthopaedic Trauma Association\u2019s (OTA) membership. J Orthop Trauma. 2014;28:e221-5.","journal-title":"J Orthop Trauma"},{"key":"6124_CR21","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1097\/BOT.0000000000000014","volume":"28","author":"CA Collinge","year":"2014","unstructured":"Collinge CA, Mir H, Reddix R. Fracture morphology of high shear angle \u201cvertical\u201d femoral neck fractures in young adult patients. J Orthop Trauma. 2014;28:270\u20135.","journal-title":"J Orthop Trauma"},{"key":"6124_CR22","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.apergo.2017.04.008","volume":"63","author":"J Van Houcke","year":"2017","unstructured":"Van Houcke J, Schouten A, Steenackers G, Vandermeulen D, Pattyn C, Audenaert EA. Computer-based estimation of the hip joint reaction force and hip flexion angle in three different sitting configurations. Appl Ergon. 2017;63:99\u2013105.","journal-title":"Appl Ergon"},{"key":"6124_CR23","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1002\/jor.22266","volume":"31","author":"JM Goffin","year":"2013","unstructured":"Goffin JM, Pankaj P, Simpson AH. The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: a subject-specific finite element study. J Orthop Res. 2013;31:596\u2013600.","journal-title":"J Orthop Res"},{"key":"6124_CR24","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.clinbiomech.2020.02.016","volume":"74","author":"L Zhou","year":"2020","unstructured":"Zhou L, Lin J, Huang A, Gan W, Zhai X, Sun K, et al. Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: a biomechanical study. Clin Biomech (Bristol Avon). 2020;74:103\u201310.","journal-title":"Clin Biomech (Bristol Avon)"},{"key":"6124_CR25","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","volume":"50","author":"J Li","year":"2019","unstructured":"Li J, Yin P, Zhang L, Chen H, Tang P. Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis. Injury. 2019;50:1895\u2013900.","journal-title":"Injury"},{"key":"6124_CR26","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1177\/0954411918789963","volume":"232","author":"E Sensoz","year":"2018","unstructured":"Sensoz E, Ozkal FM, Acar V, Cakir F. Finite element analysis of the impact of screw insertion distal to the trochanter minor on the risk of iatrogenic subtrochanteric fracture. Proc Inst Mech Eng H. 2018;232:807\u201318.","journal-title":"Proc Inst Mech Eng H"},{"key":"6124_CR27","first-page":"3069129","volume":"2021","author":"G Zhao","year":"2021","unstructured":"Zhao G, Liu C, Chen K, Lyu J, Chen J, Shi J, et al. Nonanatomical reduction of femoral Neck Fractures in Young Patients (<\/=65 years old) with internal fixation using three parallel cannulated screws. Biomed Res Int. 2021;2021:3069129.","journal-title":"Biomed Res Int"},{"key":"6124_CR28","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1186\/s13018-020-02039-0","volume":"15","author":"K Huang","year":"2020","unstructured":"Huang K, Fang X, Li G, Yue J. Assessing the effect of Gotfried reduction with positive buttress pattern in the young femoral neck fracture. J Orthop Surg Res. 2020;15:511.","journal-title":"J Orthop Surg Res"},{"key":"6124_CR29","doi-asserted-by":"publisher","first-page":"e403-e8","DOI":"10.1097\/BOT.0000000000001564","volume":"33","author":"D Jayaramaraju","year":"2019","unstructured":"Jayaramaraju D, Valleri DP, Agraharam D, Shanmuganathan R. Impaction Bone Grafting and Valgus Osteotomy: a technical trick for the treatment of femoral Neck Nonunions. J Orthop Trauma. 2019;33:e403-e8.","journal-title":"J Orthop Trauma"},{"key":"6124_CR30","doi-asserted-by":"publisher","first-page":"109801","DOI":"10.1016\/j.biopha.2019.109801","volume":"123","author":"G Wang","year":"2020","unstructured":"Wang G, Wang B, Wu X, Yang H. Gotfried positive reduction promotes the repair of femoral neck fracture potentially via enhancing osteogenesis and angiogenesis. Biomed Pharmacother. 2020;123:109801.","journal-title":"Biomed Pharmacother"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-06124-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-06124-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-06124-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,21]],"date-time":"2023-01-21T10:03:35Z","timestamp":1674295415000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-06124-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,21]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["6124"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-06124-9","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,21]]},"assertion":[{"value":"25 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Research involving human participants have been performed in accordance with the Declaration of Helsinki and has been approved by the Ethics Committee of the Second Affiliated Hospital of Guangzhou University of Chinese Medicine with the ethical registration ID YE2020-245. For the human participant informed consent to participate in the study was obtained from the participant. Consent was obtained for all forms of personally identifiable data.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"54"}}