{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T12:45:38Z","timestamp":1778503538521,"version":"3.51.4"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,24]],"date-time":"2023-01-24T00:00:00Z","timestamp":1674518400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,24]],"date-time":"2023-01-24T00:00:00Z","timestamp":1674518400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Proximal humerus fractures are often treated with a fixed-angle titanium plate osteosynthesis. Recently, plates made of alternative materials such as carbon fibre-reinforced polyetheretherketone (CFR-PEEK) have been introduced. This study presents the postoperative results of patients treated with a CFR-PEEK plate.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Patients with proximal humerus fractures treated with a CFR-PEEK plate (PEEKPower\u2122 Humeral Fracture Plate (HFP)) were included. In follow-up examination, age and gender adjusted Constant-Murley Score (ACS), Subjective Shoulder Value (SSV), Quick Disabilities of the Arm, Shoulder and Hand Score (QDASH) and pain score (Visual Analog Scale (VAS)) were analyzed. General condition at follow-up was measured by European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-3L). Range of motion was recorded. In addition, radiographs at follow-up, unfavorable events and revision rate were analyzed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In total, 98 patients (66.0\u2009\u00b1\u200913.2\u00a0years, 74 females, 24 males) were reexamined. Mean follow-up was 27.6\u2009\u00b1\u200913.2\u00a0months. There were 15 2-part, 28 3-part and 55 4-part fractures. The functional scores showed good results: SSV 83.3\u2009\u00b1\u200915.6%, QDASH 13.1\u2009\u00b1\u200917.0 and ACS 80.4\u2009\u00b1\u200916.0. A 4-part-fracture, head split component, nonanatomic head shaft reposition and preoperative radiological signs of osteoarthritis were significant negative predictors for poorer clinical scores. Unfavourable events were observed in 27 patients (27.6%). Revision surgery was performed in 8 (8.2%) patients. Risk factors for an unfavourable event were female gender, age of 50\u00a0years and older, diabetes, affected dominant hand, 4-part fracture, head split and preoperative radiological signs of\u00a0osteoarthritis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>There are several advantages of the CFR-PEEK plate (PEEKPower\u2122 Humeral Fracture Plate (HFP)) such as the polyaxial screw placement and higher stability of locking screws. In summary, the CFR-PEEK plate osteosynthesis is a good alternative with comparable clinical results and some biomechanical advantages. Proximal humerus fractures show good clinical results after treatment with a CFR-PEEK plate. The revision rate and the risk of unfavorable events are not increased compared to conventional titanium plate osteosynthesis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>IV<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-023-06176-5","type":"journal-article","created":{"date-parts":[[2023,1,24]],"date-time":"2023-01-24T05:06:11Z","timestamp":1674536771000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system"],"prefix":"10.1186","volume":"24","author":[{"given":"Michael","family":"Kimmeyer","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonas","family":"Schmalzl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Verena","family":"Rentschler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Malik","family":"Jessen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Gerhardt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars-Johannes","family":"Lehmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,1,24]]},"reference":[{"issue":"10","key":"6176_CR1","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","volume":"21","author":"J Agudelo","year":"2007","unstructured":"Agudelo J, Sch\u00fcrmann M, Stahel P, Helwig P, Morgan SJ, Zechel W, et al. Analysis of Efficacy and Failure in Proximal Humerus Fractures Treated With Locking Plates. J Orthop Trauma. 2007;21(10):676\u201381. https:\/\/doi.org\/10.1097\/BOT.0b013e31815bb09d.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"6176_CR2","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1186\/s12891-020-03353-8","volume":"21","author":"N Alispahic","year":"2020","unstructured":"Alispahic N, Brorson S, Bahrs C, Joeris A, Steinitz A, Audig\u00e9 L. Complications after surgical management of proximal humeral fractures: a systematic review of event terms and definitions. BMC Musculoskelet Disord. 2020;21(1):327. https:\/\/doi.org\/10.1186\/s12891-020-03353-8.","journal-title":"BMC Musculoskelet Disord"},{"issue":"6","key":"6176_CR3","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1007\/s00264-009-0848-4","volume":"34","author":"C Bahrs","year":"2010","unstructured":"Bahrs C, Badke A, Rolauffs B, Weise K, Zipplies S, Dietz K, et al. Long-term results after non-plate head-preserving fixation of proximal humeral fractures. International Orthopaedics (SICOT). 2010;34(6):883\u20139. https:\/\/doi.org\/10.1007\/s00264-009-0848-4.","journal-title":"International Orthopaedics (SICOT)"},{"issue":"4","key":"6176_CR4","doi-asserted-by":"publisher","first-page":"475","DOI":"10.3109\/17453674.2011.588856","volume":"82","author":"S Brorson","year":"2011","unstructured":"Brorson S, Frich LH, Winther A, Hr\u00f3bjartsson A. Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus: A systematic review of benefits and harms. Acta Orthop. 2011;82(4):475\u201381. https:\/\/doi.org\/10.3109\/17453674.2011.588856.","journal-title":"Acta Orthop"},{"issue":"7","key":"6176_CR5","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1016\/j.injury.2011.08.025","volume":"43","author":"S Brorson","year":"2012","unstructured":"Brorson S, Rasmussen JV, Frich LH, Olsen BS, Hr\u00f3bjartsson A. Benefits and harms of locking plate osteosynthesis in intraarticular (OTA Type C) fractures of the proximal humerus: A systematic review. Injury. 2012;43(7):999\u20131005. https:\/\/doi.org\/10.1016\/j.injury.2011.08.025.","journal-title":"Injury"},{"issue":"3","key":"6176_CR6","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/BOT.0b013e3181920e5b","volume":"23","author":"F Brunner","year":"2009","unstructured":"Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, et al. Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis. J Orthop Trauma. 2009;23(3):163\u201372. https:\/\/doi.org\/10.1097\/BOT.0b013e3181920e5b.","journal-title":"J Orthop Trauma"},{"key":"6176_CR7","doi-asserted-by":"publisher","unstructured":"Burkhart KJ, Dietz SO, Bastian L, Thelen U, Hoffmann R, M\u00fcller LP. The Treatment of Proximal Humeral Fracture in Adults. Deutsches Aerzteblatt Online. 2013 Sep 2;Available from: https:\/\/www.aerzteblatt.de\/https:\/\/doi.org\/10.3238\/arztebl.2013.0591doi:10.3238\/arztebl.2013.0591. [Cited 28 Aug 2021].","DOI":"10.3238\/arztebl.2013.0591doi:10.3238\/arztebl.2013.0591"},{"issue":"4","key":"6176_CR8","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1080\/000164701753542023","volume":"72","author":"CM Court-Brown","year":"2001","unstructured":"Court-Brown CM, Garg A, McQueen MM. The epidemiology of proximal humeral fractures. Acta Orthop Scand. 2001;72(4):365\u201371. https:\/\/doi.org\/10.1080\/000164701753542023.","journal-title":"Acta Orthop Scand"},{"issue":"7","key":"6176_CR9","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.2106\/JBJS.F.00247","volume":"89","author":"DR Epari","year":"2007","unstructured":"Epari DR, Kassi J-P, Schell H, Duda GN. Timely Fracture-Healing Requires Optimization of Axial Fixation Stability. The J Bone & Joint Surg. 2007;89(7):1575\u201385. https:\/\/doi.org\/10.2106\/JBJS.F.00247.","journal-title":"The J Bone & Joint Surg"},{"issue":"6","key":"6176_CR10","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1016\/j.injury.2010.02.022","volume":"41","author":"MJ Gardner","year":"2010","unstructured":"Gardner MJ, Nork SE, Huber P, Krieg JC. Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots. Injury. 2010;41(6):652\u20136. https:\/\/doi.org\/10.1016\/j.injury.2010.02.022.","journal-title":"Injury"},{"issue":"2","key":"6176_CR11","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1097\/BOT.0b013e31825cf545","volume":"27","author":"AS Gavaskar","year":"2013","unstructured":"Gavaskar AS, Chowdary N, Abraham S. Complex Proximal Humerus Fractures Treated With Locked Plating Utilizing an Extended Deltoid Split Approach With a Shoulder Strap Incision. J Orthop Trauma. 2013;27(2):73\u20136. https:\/\/doi.org\/10.1097\/BOT.0b013e31825cf545.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"6176_CR12","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1016\/j.jse.2014.10.003","volume":"24","author":"AS Gavaskar","year":"2015","unstructured":"Gavaskar AS, Tummala NC. Locked plate osteosynthesis of humeral head\u2013splitting fractures in young adults. J Shoulder Elbow Surg. 2015;24(6):908\u201314. https:\/\/doi.org\/10.1016\/j.jse.2014.10.003.","journal-title":"J Shoulder Elbow Surg"},{"issue":"1","key":"6176_CR13","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/1471-2474-7-44","volume":"7","author":"C Gummesson","year":"2006","unstructured":"Gummesson C, Ward MM, Atroshi I. The shortened disabilities of the arm, shoulder and hand questionnaire (Quick DASH): validity and reliability based on responses within the full-length DASH. BMC Musculoskelet Disord. 2006;7(1):44. https:\/\/doi.org\/10.1186\/1471-2474-7-44.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"6176_CR14","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/BOT.0000000000000229","volume":"29","author":"AK Gupta","year":"2015","unstructured":"Gupta AK, Harris JD, Erickson BJ, Abrams GD, Bruce B, McCormick F, et al. Surgical Management of Complex Proximal Humerus Fractures\u2014A Systematic Review of 92 Studies Including 4500 Patients. J Orthop Trauma. 2015;29(1):54\u20139. https:\/\/doi.org\/10.1097\/BOT.0000000000000229.","journal-title":"J Orthop Trauma"},{"issue":"9","key":"6176_CR15","doi-asserted-by":"publisher","first-page":"1735","DOI":"10.1007\/s00264-017-3562-7","volume":"41","author":"DJ Hak","year":"2017","unstructured":"Hak DJ, Fader R, Baldini T, Chadayammuri VBS. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates. International Orthopaedics (SICOT). 2017;41(9):1735\u20139. https:\/\/doi.org\/10.1007\/s00264-017-3562-7.","journal-title":"International Orthopaedics (SICOT)"},{"issue":"4","key":"6176_CR16","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.jse.2004.01.034","volume":"13","author":"R Hertel","year":"2004","unstructured":"Hertel R, Hempfing A, Stiehler M, Leunig M. Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. J Shoulder Elbow Surg. 2004;13(4):427\u201333. https:\/\/doi.org\/10.1016\/j.jse.2004.01.034.","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"6176_CR17","doi-asserted-by":"publisher","first-page":"1565","DOI":"10.1007\/s11999-009-1007-3","volume":"468","author":"MT Hirschmann","year":"2010","unstructured":"Hirschmann MT, Wind B, Amsler F, Gross T. Reliability of Shoulder Abduction Strength Measure for the Constant-Murley Score. Clin Orthop Relat Res. 2010;468(6):1565\u201371. https:\/\/doi.org\/10.1007\/s11999-009-1007-3.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"6176_CR18","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/s12306-014-0331-2","volume":"99","author":"C Iacobellis","year":"2015","unstructured":"Iacobellis C, Berizzi A, Biz C, Camporese A. Treatment of proximal humeral fractures with reverse shoulder arthroplasty in elderly patients. Musculoskelet Surg. 2015;99(1):39\u201344. https:\/\/doi.org\/10.1007\/s12306-014-0331-2.","journal-title":"Musculoskelet Surg"},{"issue":"7","key":"6176_CR19","doi-asserted-by":"publisher","first-page":"1402","DOI":"10.1016\/j.arthro.2016.03.024","volume":"32","author":"E Itoi","year":"2016","unstructured":"Itoi E, Arce G, Bain GI, Diercks RL, Guttmann D, Imhoff AB, et al. Shoulder Stiffness: Current Concepts and Concerns. Arthroscopy: The Journal of Arthroscopic & Related Surgery. 2016;32(7):1402\u201314. https:\/\/doi.org\/10.1016\/j.arthro.2016.03.024.","journal-title":"Arthroscopy: The Journal of Arthroscopic & Related Surgery"},{"issue":"6","key":"6176_CR20","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1097\/BOT.0000000000000252","volume":"29","author":"S-W Jung","year":"2015","unstructured":"Jung S-W, Shim S-B, Kim H-M, Lee J-H, Lim H-S. Factors that Influence Reduction Loss in Proximal Humerus Fracture Surgery. J Orthop Trauma. 2015;29(6):276\u201382. https:\/\/doi.org\/10.1097\/BOT.0000000000000252.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"6176_CR21","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/s10195-017-0457-8","volume":"18","author":"JC Katthagen","year":"2017","unstructured":"Katthagen JC, Huber M, Grabowski S, Ellwein A, Jensen G, Lill H. Failure and revision rates of proximal humeral fracture treatment with the use of a standardized treatment algorithm at a level-1 trauma center. J Orthop Traumatol. 2017;18(3):265\u201374. https:\/\/doi.org\/10.1007\/s10195-017-0457-8.","journal-title":"J Orthop Traumatol"},{"issue":"3","key":"6176_CR22","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.injury.2016.01.004","volume":"47","author":"JC Katthagen","year":"2016","unstructured":"Katthagen JC, Schwarze M, Warnhoff M, Voigt C, Hurschler C, Lill H. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury. 2016;47(3):617\u201324. https:\/\/doi.org\/10.1016\/j.injury.2016.01.004.","journal-title":"Injury"},{"issue":"3","key":"6176_CR23","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.injury.2016.01.004","volume":"47","author":"JC Katthagen","year":"2016","unstructured":"Katthagen JC, Schwarze M, Warnhoff M, Voigt C, Hurschler C, Lill H. Influence of plate material and screw design on stiffness and ultimate load of locked plating in osteoporotic proximal humeral fractures. Injury. 2016;47(3):617\u201324. https:\/\/doi.org\/10.1016\/j.injury.2016.01.004.","journal-title":"Injury"},{"issue":"2","key":"6176_CR24","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1007\/s12178-020-09597-0","volume":"13","author":"BJ Kelly","year":"2020","unstructured":"Kelly BJ, Myeroff CM. Reverse Shoulder Arthroplasty for Proximal Humerus Fracture. Curr Rev Musculoskelet Med. 2020;13(2):186\u201399. https:\/\/doi.org\/10.1007\/s12178-020-09597-0.","journal-title":"Curr Rev Musculoskelet Med"},{"issue":"1","key":"6176_CR25","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1186\/s13018-017-0639-3","volume":"12","author":"CJ Laux","year":"2017","unstructured":"Laux CJ, Grubhofer F, Werner CML, Simmen H-P, Osterhoff G. Current concepts in locking plate fixation of proximal humerus fractures. J Orthop Surg Res. 2017;12(1):137. https:\/\/doi.org\/10.1186\/s13018-017-0639-3.","journal-title":"J Orthop Surg Res"},{"issue":"12","key":"6176_CR26","doi-asserted-by":"publisher","first-page":"1865","DOI":"10.1016\/S0021-9290(03)00212-4","volume":"36","author":"ZM Maldonado","year":"2003","unstructured":"Maldonado ZM, Seebeck J, Heller MOW, Brandt D, Hepp P, Lill H, et al. Straining of the intact and fractured proximal humerus under physiological-like loading. J Biomech. 2003;36(12):1865\u201373. https:\/\/doi.org\/10.1016\/S0021-9290(03)00212-4.","journal-title":"J Biomech"},{"issue":"1","key":"6176_CR27","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/BOT.0000000000001063","volume":"32","author":"E Meinberg","year":"2018","unstructured":"Meinberg E, Agel J, Roberts C, Karam M, Kellam J. Fracture and Dislocation Classification Compendium\u20142018. J Orthop Trauma. 2018;32(1):S1\u201310. https:\/\/doi.org\/10.1097\/BOT.0000000000001063.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"6176_CR28","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","volume":"52","author":"CS Neer","year":"1970","unstructured":"Neer CS. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am. 1970;52(6):1077\u201389.","journal-title":"J Bone Joint Surg Am"},{"issue":"S1","key":"6176_CR29","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1007\/s12306-018-0562-8","volume":"102","author":"A Padolino","year":"2018","unstructured":"Padolino A, Porcellini G, Guollo B, Fabbri E, Kiran Kumar GN, Paladini P, et al. Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes. Musculoskelet Surg. 2018;102(S1):49\u201356. https:\/\/doi.org\/10.1007\/s12306-018-0562-8.","journal-title":"Musculoskelet Surg"},{"key":"6176_CR30","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/01.blo.0000194672.79634.78","volume":"442","author":"M Palvanen","year":"2006","unstructured":"Palvanen M, Kannus P, Niemi S, Parkkari J. Update in the Epidemiology of Proximal Humeral Fractures. Clin Orthop Relat Res. 2006;442:87\u201392. https:\/\/doi.org\/10.1097\/01.blo.0000194672.79634.78.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"6176_CR31","doi-asserted-by":"publisher","first-page":"456","DOI":"10.2106\/00004623-198365040-00005","volume":"65","author":"RL Samilson","year":"1983","unstructured":"Samilson RL, Prieto V. Dislocation arthropathy of the shoulder. J Bone Joint Surg Am. 1983;65(4):456\u201360.","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"6176_CR32","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1016\/j.jse.2014.12.028","volume":"24","author":"B Schliemann","year":"2015","unstructured":"Schliemann B, Hartensuer R, Koch T, Theisen C, Raschke MJ, K\u00f6sters C, et al. Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. J Shoulder Elbow Surg. 2015;24(8):1282\u20138. https:\/\/doi.org\/10.1016\/j.jse.2014.12.028.","journal-title":"J Shoulder Elbow Surg"},{"issue":"1","key":"6176_CR33","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s00402-016-2620-8","volume":"137","author":"B Schliemann","year":"2017","unstructured":"Schliemann B, Seifert R, Theisen C, Gehweiler D, W\u00e4hnert D, Schulze M, et al. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures. Arch Orthop Trauma Surg. 2017;137(1):63\u201371. https:\/\/doi.org\/10.1007\/s00402-016-2620-8.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"6176_CR34","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s00402-016-2620-8","volume":"137","author":"B Schliemann","year":"2017","unstructured":"Schliemann B, Seifert R, Theisen C, Gehweiler D, W\u00e4hnert D, Schulze M, et al. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures. Arch Orthop Trauma Surg. 2017;137(1):63\u201371. https:\/\/doi.org\/10.1007\/s00402-016-2620-8.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"21","key":"6176_CR35","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.2106\/JBJS.16.00112","volume":"98","author":"M Schnetzke","year":"2016","unstructured":"Schnetzke M, Bockmeyer J, Porschke F, Studier-Fischer S, Gr\u00fctzner P-A, Guehring T. Quality of Reduction Influences Outcome After Locked-Plate Fixation of Proximal Humeral Type-C Fractures. J Bone Joint Surg. 2016;98(21):1777\u201385. https:\/\/doi.org\/10.2106\/JBJS.16.00112.","journal-title":"J Bone Joint Surg"},{"issue":"2","key":"6176_CR36","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.clinbiomech.2006.08.009","volume":"22","author":"K Seide","year":"2007","unstructured":"Seide K, Triebe J, Faschingbauer M, Schulz AP, P\u00fcschel K, Mehrtens G, et al. Locked vs. unlocked plate osteosynthesis of the proximal humerus \u2013 A biomechanical study. Clin Biomech. 2007;22(2):176\u201382. https:\/\/doi.org\/10.1016\/j.clinbiomech.2006.08.009.","journal-title":"Clin Biomech"},{"issue":"6","key":"6176_CR37","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.2106\/JBJS.H.00006","volume":"91","author":"N S\u00fcdkamp","year":"2009","unstructured":"S\u00fcdkamp N, Bayer J, Hepp P, Voigt C, Oestern H, K\u00e4\u00e4b M, et al. Open Reduction and Internal Fixation of Proximal Humeral Fractures with Use of the Locking Proximal Humerus Plate: Results of a Prospective, Multicenter, Observational Study. The Journal of Bone and Joint Surgery-American Volume. 2009;91(6):1320\u20138. https:\/\/doi.org\/10.2106\/JBJS.H.00006.","journal-title":"The Journal of Bone and Joint Surgery-American Volume"},{"issue":"6","key":"6176_CR38","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.jse.2009.06.004","volume":"18","author":"C Thanasas","year":"2009","unstructured":"Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P. Treatment of proximal humerus fractures with locking plates: A systematic review. J Shoulder Elbow Surg. 2009;18(6):837\u201344. https:\/\/doi.org\/10.1016\/j.jse.2009.06.004.","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"6176_CR39","doi-asserted-by":"publisher","first-page":"e177","DOI":"10.1016\/j.jse.2017.02.024","volume":"26","author":"JM Tokish","year":"2017","unstructured":"Tokish JM, Alexander TC, Kissenberth MJ, Hawkins RJ. Pseudoparalysis: a systematic review of term definitions, treatment approaches, and outcomes of management techniques. J Shoulder Elbow Surg. 2017;26(6):e177\u201387. https:\/\/doi.org\/10.1016\/j.jse.2017.02.024.","journal-title":"J Shoulder Elbow Surg"},{"issue":"6","key":"6176_CR40","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1016\/S0883-5403(99)90232-2","volume":"14","author":"G Walch","year":"1999","unstructured":"Walch G, Badet R, Boulahia A, Khoury A. Morphologic study of the Glenoid in primary glenohumeral osteoarthritis. J Arthroplasty. 1999;14(6):756\u201360. https:\/\/doi.org\/10.1016\/S0883-5403(99)90232-2.","journal-title":"J Arthroplasty"},{"issue":"6","key":"6176_CR41","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1016\/j.otsr.2018.07.003","volume":"104","author":"J-D Werthel","year":"2018","unstructured":"Werthel J-D, Sirveaux F, Block D. Reverse shoulder arthroplasty in recent proximal humerus fractures. Orthop Traumatol Surg Res. 2018;104(6):779\u201385. https:\/\/doi.org\/10.1016\/j.otsr.2018.07.003.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"5","key":"6176_CR42","doi-asserted-by":"publisher","first-page":"623","DOI":"10.5312\/wjo.v5.i5.623","volume":"5","author":"JD Wylie","year":"2014","unstructured":"Wylie JD. Functional outcomes assessment in shoulder surgery. WJO. 2014;5(5):623. https:\/\/doi.org\/10.5312\/wjo.v5.i5.623.","journal-title":"WJO"},{"key":"6176_CR43","doi-asserted-by":"publisher","unstructured":"Ziegler P, Maier S, St\u00f6ckle U, G\u00fchring M, Stuby FM. The Treatment of Proximal Humerus Fracture Using Internal Fixation With Fixed-angle Plates. Deutsches Aerzteblatt Online. 2019 Nov 8;Available from: https:\/\/www.aerzteblatt.de\/https:\/\/doi.org\/10.3238\/arztebl.2019.0757doi:10.3238\/arztebl.2019.0757. [Cited 11 Apr 2021].","DOI":"10.3238\/arztebl.2019.0757doi:10.3238\/arztebl.2019.0757"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06176-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-023-06176-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06176-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,24]],"date-time":"2023-01-24T05:07:15Z","timestamp":1674536835000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-023-06176-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,24]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["6176"],"URL":"https:\/\/doi.org\/10.1186\/s12891-023-06176-5","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,24]]},"assertion":[{"value":"22 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the local Ethics committee of the University of Mannheim\/Heidelberg, Germany. Written informed consent was obtained from all patients. Ethics approval number is 2019-755\u00a0N. The conducted experiments respect the ethical standards in the Helsinki Declaration of 1975, as revised in 2000, as well as the national law.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All subjects who can be identified in the figures (Fig.\u00a0) have been informed about the open access publication. A declaration of the informed consent form for publication was signed by the subject.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Lars-Johannes Lehmann and Christian Gerhardt are consultants for Arthrex and DJO. Michael Kimmeyer, Jonas Schmalzl, Verena Rentschler und Malik Jessen have no competing interest to disclose. The research foundation received financial payments of Fa. Arthrex (Munich, Germany) for the conduct of this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"63"}}