{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T15:49:26Z","timestamp":1795189766720,"version":"4.10.3"},"reference-count":52,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81472140"],"award-info":[{"award-number":["81472140"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100006606","name":"Natural Science Foundation of Tianjin City","doi-asserted-by":"publisher","award":["S20ZDD484"],"award-info":[{"award-number":["S20ZDD484"]}],"id":[{"id":"10.13039\/501100006606","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To study the biomechanical characteristics of various tissue structures of different sizes of 3D printed Cage in lumbar interbody fusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A finite element model of normal spine was reconstructed and verified. Pedicle screws and Cage of different sizes were implanted in the L4\/5 segment to simulate lumbar interbody fusion. The range of motion of the fixed and cephalic adjacent segment, the stress of the screw-rod system, the stress at the interface between cage and L5 endplate, and intervertebral disc pressure of the adjacent segment were calculated and analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The range of motion and intervertebral disc pressure of the adjacent segment of each postoperative model were larger than those of the intact model, but there was not much difference between them. The stress of cage-endplate interface was also larger than that of the intact model. However, the difference is that the stress of the endplate and the screw-rod system has a tendency to decrease with the increase of the axial area of cage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Cage with larger axial area in lumbar interbody fusion can reduce the stress of internal fixation system and endplate, but will not increase the range of motion and intervertebral disc pressure of adjacent segment. It has a certain effect in preventing the cage subsidence, internal fixation system failure and screw rod fracture.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-023-06201-7","type":"journal-article","created":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T01:08:01Z","timestamp":1675213681000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Biomechanical evaluation of different sizes of 3D printed cage in lumbar interbody fusion-a finite element analysis"],"prefix":"10.1186","volume":"24","author":[{"given":"Jincheng","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qing","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongmei","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanpeng","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wangqiang","family":"Wen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoxiang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Miao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,2,1]]},"reference":[{"issue":"10159","key":"6201_CR1","first-page":"1789","volume":"392","author":"SL James","year":"2018","unstructured":"James SL, Geleijnse JM. Global, regional, and national incidence, prevalence, and years lived with disability for 354 diseases and injuries for 195 countries and territories, 1990\u20132017: a systematic analysis for the Global Burden of Disease Study 2017. Lancet (British edition). 2018;392(10159):1789\u2013858.","journal-title":"Lancet (British edition)"},{"issue":"S4","key":"6201_CR2","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00586-008-0747-1","volume":"17","author":"S Kikuchi","year":"2008","unstructured":"Kikuchi S. New concept for backache: biopsychosocial pain syndrome. Eur Spine J. 2008;17(S4):421\u20137.","journal-title":"Eur Spine J"},{"issue":"1\u20132","key":"6201_CR3","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1007\/s10354-015-0413-2","volume":"166","author":"TE Dorner","year":"2016","unstructured":"Dorner TE, Crevenna R. Preventive aspects regarding back pain. Wien Med Wochenschr. 2016;166(1\u20132):15\u201321.","journal-title":"Wien Med Wochenschr"},{"issue":"1","key":"6201_CR4","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1007\/s00586-020-06596-0","volume":"30","author":"B Meng","year":"2021","unstructured":"Meng B, et al. Lumbar interbody fusion: recent advances in surgical techniques and bone healing strategies. Eur Spine J. 2021;30(1):22\u201333.","journal-title":"Eur Spine J"},{"issue":"10137","key":"6201_CR5","doi-asserted-by":"publisher","first-page":"2356","DOI":"10.1016\/S0140-6736(18)30480-X","volume":"391","author":"J Hartvigsen","year":"2018","unstructured":"Hartvigsen J, et al. What low back pain is and why we need to pay attention. Lancet. 2018;391(10137):2356\u201367.","journal-title":"Lancet"},{"issue":"2","key":"6201_CR6","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1002\/ejp.1679","volume":"25","author":"N Corp","year":"2021","unstructured":"Corp N, et al. Evidence-based treatment recommendations for neck and low back pain across Europe: A systematic review of guidelines. Eur J Pain. 2021;25(2):275\u201395.","journal-title":"Eur J Pain"},{"issue":"1","key":"6201_CR7","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1007\/s00132-018-03670-w","volume":"48","author":"KJ Schnake","year":"2019","unstructured":"Schnake KJ, et al. Lumbale Spondylodese \u2013 Indikationen und Techniken. Orthopade. 2019;48(1):50\u20138.","journal-title":"Orthopade"},{"issue":"4","key":"6201_CR8","doi-asserted-by":"publisher","first-page":"645","DOI":"10.4184\/asj.2015.9.4.645","volume":"9","author":"S Baliga","year":"2015","unstructured":"Baliga S, Treon K, Craig NJA. Low Back Pain: Current Surgical Approaches. Asian Spine J. 2015;9(4):645.","journal-title":"Asian Spine J"},{"issue":"4","key":"6201_CR9","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/2015.7.FOCUS15292","volume":"39","author":"DS Chun","year":"2015","unstructured":"Chun DS, Baker KC, Hsu WK. Lumbar pseudarthrosis: a review of current diagnosis and treatment. Neurosurg Focus. 2015;39(4):E10.","journal-title":"Neurosurg Focus"},{"issue":"49","key":"6201_CR10","doi-asserted-by":"publisher","first-page":"e28085","DOI":"10.1097\/MD.0000000000028085","volume":"100","author":"Q Li","year":"2021","unstructured":"Li Q, et al. Prevalence and risk factors for cage subsidence after lumbar interbody fusion. Medicine. 2021;100(49):e28085.","journal-title":"Medicine"},{"issue":"1","key":"6201_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s12306-019-00634-x","volume":"104","author":"M Formica","year":"2020","unstructured":"Formica M, et al. Fusion rate and influence of surgery-related factors in lumbar interbody arthrodesis for degenerative spine diseases: a meta-analysis and systematic review. Musculoskelet Surg. 2020;104(1):1\u201315.","journal-title":"Musculoskelet Surg"},{"issue":"4","key":"6201_CR12","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1055\/s-0032-1315454","volume":"2","author":"WK Hsu","year":"2012","unstructured":"Hsu WK, et al. Improving the Clinical Evidence of Bone Graft Substitute Technology in Lumbar Spine Surgery. Global Spine J. 2012;2(4):239\u201348.","journal-title":"Global Spine J"},{"issue":"6","key":"6201_CR13","doi-asserted-by":"publisher","first-page":"E683","DOI":"10.1097\/BSD.0000000000000315","volume":"30","author":"KW Oh","year":"2017","unstructured":"Oh KW, et al. The Correlation Between Cage Subsidence, Bone Mineral Density, and Clinical Results in Posterior Lumbar Interbody Fusion. Clin Spine Surg. 2017;30(6):E683\u20139.","journal-title":"Clin Spine Surg"},{"key":"6201_CR14","doi-asserted-by":"crossref","unstructured":"Kotheeranurak V, et al. Subsidence of Interbody Cage Following Oblique Lateral Interbody Fusion: An Analysis and Potential Risk Factors. Global Spine J. 2021;21925682211067210.","DOI":"10.1177\/21925682211067210"},{"issue":"2","key":"6201_CR15","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1097\/BRS.0000000000003194","volume":"45","author":"W Yuan","year":"2020","unstructured":"Yuan W, et al. Does Lumbar Interbody Cage Size Influence Subsidence? A Biomechanical Study. Spine. 2020;45(2):88\u201395.","journal-title":"Spine"},{"issue":"1","key":"6201_CR16","doi-asserted-by":"publisher","first-page":"125","DOI":"10.3171\/2016.6.SPINE151477","volume":"26","author":"S Bess","year":"2017","unstructured":"Bess S, et al. The effect of posterior polyester tethers on the biomechanics of proximal junctional kyphosis: a finite element analysis. J Neurosurg Spine. 2017;26(1):125\u201333.","journal-title":"J Neurosurg Spine"},{"issue":"5","key":"6201_CR17","doi-asserted-by":"publisher","first-page":"301","DOI":"10.3109\/17453677208998949","volume":"43","author":"WA Brekelmans","year":"1972","unstructured":"Brekelmans WA, Poort HW, Slooff TJ. A new method to analyse the mechanical behaviour of skeletal parts. Acta Orthop Scand. 1972;43(5):301.","journal-title":"Acta Orthop Scand"},{"key":"6201_CR18","doi-asserted-by":"publisher","first-page":"S6","DOI":"10.1097\/BRS.0000000000001421","volume":"41","author":"VK Goel","year":"2016","unstructured":"Goel VK, Nyman E. Computational Modeling and Finite Element Analysis. Spine. 2016;41:S6\u20137.","journal-title":"Spine"},{"issue":"5","key":"6201_CR19","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1243\/09544110260216568","volume":"216","author":"MJ Fagan","year":"2002","unstructured":"Fagan MJ, Julian S, Mohsen AM. Finite element analysis in spine research. Proc Inst Mech Eng H J Eng Med. 2002;216(5):281\u201398.","journal-title":"Proc Inst Mech Eng H J Eng Med"},{"issue":"8","key":"6201_CR20","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1097\/BSD.0000000000001050","volume":"33","author":"A Welch-Phillips","year":"2020","unstructured":"Welch-Phillips A, et al. What Is Finite Element Analysis? Clin Spine Surg. 2020;33(8):323\u20134.","journal-title":"Clin Spine Surg"},{"key":"6201_CR21","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1016\/j.actbio.2015.11.013","volume":"30","author":"FA Shah","year":"2016","unstructured":"Shah FA, et al. 3D printed Ti6Al4V implant surface promotes bone maturation and retains a higher density of less aged osteocytes at the bone-implant interface. Acta Biomater. 2016;30:357\u201367.","journal-title":"Acta Biomater"},{"issue":"1","key":"6201_CR22","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1186\/s13018-022-03317-9","volume":"17","author":"J Wu","year":"2022","unstructured":"Wu J, et al. Application of dual-trajectory screws in revision surgery for lumbar adjacent segment disease: a finite element study. J Orthop Surg Res. 2022;17(1):427.","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"6201_CR23","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.3349\/ymj.2014.55.5.1386","volume":"55","author":"H Kim","year":"2014","unstructured":"Kim H, et al. Biomechanical Analysis of Fusion Segment Rigidity Upon Stress at Both the Fusion and Adjacent Segments: A Comparison between Unilateral and Bilateral Pedicle Screw Fixation. Yonsei Med J. 2014;55(5):1386.","journal-title":"Yonsei Med J"},{"issue":"9","key":"6201_CR24","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1002\/jor.22376","volume":"31","author":"M Alizadeh","year":"2013","unstructured":"Alizadeh M, et al. The use of X-shaped cross-link in posterior spinal constructs improves stability in thoracolumbar burst fracture: A finite element analysis. J Orthop Res. 2013;31(9):1447\u201354.","journal-title":"J Orthop Res"},{"issue":"34","key":"6201_CR25","doi-asserted-by":"publisher","first-page":"e12046","DOI":"10.1097\/MD.0000000000012046","volume":"97","author":"Y Su","year":"2018","unstructured":"Su Y, et al. A finite element study on posterior short segment fixation combined with unilateral fixation using pedicle screws for stable thoracolumbar fracture. Medicine. 2018;97(34):e12046.","journal-title":"Medicine"},{"issue":"6","key":"6201_CR26","doi-asserted-by":"publisher","first-page":"e99156","DOI":"10.1371\/journal.pone.0099156","volume":"9","author":"C Li","year":"2014","unstructured":"Li C, et al. Treatment of unstable thoracolumbar fractures through short segment pedicle screw fixation techniques using pedicle fixation at the level of the fracture: a finite element analysis. PLoS ONE. 2014;9(6):e99156\u2013e99156.","journal-title":"PLoS ONE"},{"issue":"6","key":"6201_CR27","doi-asserted-by":"publisher","first-page":"E332","DOI":"10.1097\/BRS.0000000000001789","volume":"42","author":"J Choi","year":"2017","unstructured":"Choi J, Shin D, Kim S. Biomechanical Effects of the Geometry of Ball-and-Socket Artificial Disc on Lumbar Spine. Spine. 2017;42(6):E332\u20139.","journal-title":"Spine"},{"key":"6201_CR28","doi-asserted-by":"publisher","first-page":"e890","DOI":"10.1016\/j.wneu.2019.06.074","volume":"129","author":"T Lu","year":"2019","unstructured":"Lu T, Lu Y. Comparison of Biomechanical Performance Among Posterolateral Fusion and Transforaminal, Extreme, and Oblique Lumbar Interbody Fusion: A Finite Element Analysis. World Neurosurg. 2019;129:e890\u20139.","journal-title":"World Neurosurg"},{"issue":"4","key":"6201_CR29","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1007\/s00586-002-0505-8","volume":"12","author":"A Polikeit","year":"2003","unstructured":"Polikeit A, et al. Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis. Eur Spine J. 2003;12(4):413\u201320.","journal-title":"Eur Spine J"},{"key":"6201_CR30","doi-asserted-by":"publisher","first-page":"e114","DOI":"10.1016\/j.wneu.2018.02.073","volume":"114","author":"X Zhao","year":"2018","unstructured":"Zhao X, et al. Effect of Lumbar Lordosis on the Adjacent Segment in Transforaminal Lumbar Interbody Fusion: A Finite Element Analysis. World Neurosurg. 2018;114:e114\u201320.","journal-title":"World Neurosurg"},{"issue":"4","key":"6201_CR31","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.clinbiomech.2006.11.008","volume":"22","author":"H Schmidt","year":"2007","unstructured":"Schmidt H, et al. Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment. Clin Biomech. 2007;22(4):377\u201384.","journal-title":"Clin Biomech"},{"issue":"7","key":"6201_CR32","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/j.cad.2007.03.005","volume":"39","author":"DS Shin","year":"2007","unstructured":"Shin DS, Lee K, Kim D. Biomechanical study of lumbar spine with dynamic stabilization device using finite element method. Comput Aided Des. 2007;39(7):559\u201367.","journal-title":"Comput Aided Des"},{"issue":"1","key":"6201_CR33","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1186\/s12891-020-03550-5","volume":"21","author":"Q Su","year":"2020","unstructured":"Su Q, et al. Analysis and improvement of the three-column spinal theory. BMC Musculoskelet Disord. 2020;21(1):537.","journal-title":"BMC Musculoskelet Disord"},{"issue":"11","key":"6201_CR34","doi-asserted-by":"publisher","first-page":"e0166452","DOI":"10.1371\/journal.pone.0166452","volume":"11","author":"Y Huang","year":"2016","unstructured":"Huang Y, et al. Preserving Posterior Complex Can Prevent Adjacent Segment Disease following Posterior Lumbar Interbody Fusion Surgeries: A Finite Element Analysis. PLoS ONE. 2016;11(11):e0166452.","journal-title":"PLoS ONE"},{"issue":"1","key":"6201_CR35","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1186\/s12891-020-03437-5","volume":"21","author":"C Liu","year":"2020","unstructured":"Liu C, et al. Traditional and cortical trajectory screws of static and dynamic lumbar fixation- a finite element study. BMC Musculoskelet Disord. 2020;21(1):463.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"6201_CR36","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1186\/s12891-021-04899-x","volume":"22","author":"X Han","year":"2021","unstructured":"Han X, et al. Finite analysis of stability between modified articular fusion technique, posterior lumbar interbody fusion and posteriorlateral lumbar fusion. BMC Musculoskeletal Disorders. 2021;22(1):1015.","journal-title":"BMC Musculoskeletal Disorders"},{"issue":"1","key":"6201_CR37","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1186\/s12938-021-00940-1","volume":"20","author":"E Sengul","year":"2021","unstructured":"Sengul E, et al. Influence of posterior pedicle screw fixation at L4\u2013L5 level on biomechanics of the lumbar spine with and without fusion: a finite element method. BioMed Eng OnLine. 2021;20(1):98.","journal-title":"BioMed Eng OnLine"},{"issue":"1","key":"6201_CR38","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1186\/s12891-020-3103-1","volume":"21","author":"Z Liang","year":"2020","unstructured":"Liang Z, et al. Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary? BMC Musculoskelet Disord. 2020;21(1):117.","journal-title":"BMC Musculoskelet Disord"},{"key":"6201_CR39","doi-asserted-by":"publisher","first-page":"e1112","DOI":"10.1016\/j.wneu.2019.04.051","volume":"127","author":"H Shen","year":"2019","unstructured":"Shen H, et al. Biomechanical Analysis of Different Lumbar Interspinous Process Devices: A Finite Element Study. World Neurosurgery. 2019;127:e1112\u20139.","journal-title":"World Neurosurgery"},{"issue":"8","key":"6201_CR40","doi-asserted-by":"publisher","first-page":"1812","DOI":"10.1016\/j.spinee.2014.06.015","volume":"15","author":"DV Ambati","year":"2015","unstructured":"Ambati DV, et al. Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study. Spine J. 2015;15(8):1812\u201322.","journal-title":"Spine J"},{"key":"6201_CR41","doi-asserted-by":"publisher","first-page":"105741","DOI":"10.1016\/j.cmpb.2020.105741","volume":"197","author":"E Dong","year":"2020","unstructured":"Dong E, et al. Biomechanical characterization of vertebral body replacement in situ: Effects of different fixation strategies. Comput Methods Programs Biomed. 2020;197:105741.","journal-title":"Comput Methods Programs Biomed"},{"issue":"6","key":"6201_CR42","doi-asserted-by":"publisher","first-page":"1326","DOI":"10.1016\/j.jbiomech.2006.05.019","volume":"40","author":"SM Renner","year":"2007","unstructured":"Renner SM, et al. Novel model to analyze the effect of a large compressive follower pre-load on range of motions in a lumbar spine. J Biomech. 2007;40(6):1326\u201332.","journal-title":"J Biomech"},{"issue":"8","key":"6201_CR43","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1016\/j.jbiomech.2014.04.002","volume":"47","author":"M Dreischarf","year":"2014","unstructured":"Dreischarf M, et al. Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together. J Biomech. 2014;47(8):1757\u201366.","journal-title":"J Biomech"},{"issue":"6","key":"6201_CR44","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1097\/00007632-199106000-00008","volume":"16","author":"P Brinckmann","year":"1991","unstructured":"Brinckmann P, Grootenboer H. Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs. Spine (Phila Pa 1976). 1991;16(6):641\u20136.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"2","key":"6201_CR45","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.clinbiomech.2011.08.012","volume":"27","author":"HN Boustani","year":"2012","unstructured":"Boustani HN, et al. Which postures are most suitable in assessing spinal fusion using radiostereometric analysis? Clin Biomech. 2012;27(2):111\u20136.","journal-title":"Clin Biomech"},{"issue":"Suppl 8","key":"6201_CR46","first-page":"S123","volume":"41","author":"JN Sembrano","year":"2016","unstructured":"Sembrano JN, Tohmeh A, Isaacs R. Two-year Comparative Outcomes of MIS Lateral and MIS Transforaminal Interbody Fusion in the Treatment of Degenerative Spondylolisthesis: Part I: Clinical Findings. Spine. 2016;41(Suppl 8):S123\u201332.","journal-title":"Spine"},{"key":"6201_CR47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1100\/2012\/381814","volume":"2012","author":"L Pimenta","year":"2012","unstructured":"Pimenta L, et al. Biomechanics of Lateral Interbody Spacers: Going Wider for Going Stiffer. Scientific World J. 2012;2012:1\u20136.","journal-title":"Scientific World J"},{"issue":"11","key":"6201_CR48","doi-asserted-by":"publisher","first-page":"1940","DOI":"10.1007\/s00586-011-1864-9","volume":"20","author":"K Song","year":"2011","unstructured":"Song K, et al. Adjacent segment degenerative disease: is it due to disease progression or a fusion-associated phenomenon? Comparison between segments adjacent to the fused and non-fused segments. Eur Spine J. 2011;20(11):1940\u20135.","journal-title":"Eur Spine J"},{"key":"6201_CR49","doi-asserted-by":"crossref","unstructured":"Hekimo\u011flu M, et al. Adjacent Segment Disease (ASD) in Incidental Segmental Fused Vertebra and Comparison With the Effect of Stabilization Systems on ASD. Cureus. 2021;13(10):e18647.","DOI":"10.7759\/cureus.18647"},{"issue":"1","key":"6201_CR50","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1002\/jor.23283","volume":"35","author":"RN Natarajan","year":"2017","unstructured":"Natarajan RN, Andersson GBJ. Lumbar disc degeneration is an equally important risk factor as lumbar fusion for causing adjacent segment disc disease. J Orthop Res. 2017;35(1):123\u201330.","journal-title":"J Orthop Res"},{"key":"6201_CR51","doi-asserted-by":"publisher","first-page":"e690","DOI":"10.1016\/j.wneu.2019.09.112","volume":"133","author":"GA Maragkos","year":"2020","unstructured":"Maragkos GA, et al. Factors Predictive of Adjacent Segment Disease After Lumbar Spinal Fusion. World Neurosurg. 2020;133:e690\u20134.","journal-title":"World Neurosurg"},{"issue":"8","key":"6201_CR52","first-page":"1063","volume":"35","author":"L Zhao","year":"2021","unstructured":"Zhao L, et al. Advances in research on Cage subsidence following lumbar interbody fusion. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2021;35(8):1063\u20137.","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06201-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-023-06201-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06201-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,3]],"date-time":"2023-02-03T22:03:37Z","timestamp":1675461817000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-023-06201-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,1]]},"references-count":52,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["6201"],"URL":"https:\/\/doi.org\/10.1186\/s12891-023-06201-7","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,1]]},"assertion":[{"value":"1 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 February 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All clinical investigations had been conducted according to the principles expressed in the Declaration of Helsinki. This study was conducted with approval from the Ethics Committee of Tianjin Hospital. Informed consent to participate in the study was obtained from the participant.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent for publication was obtained from all participants.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"85"}}