{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:29:50Z","timestamp":1791293390121,"version":"4.1.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T00:00:00Z","timestamp":1675296000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T00:00:00Z","timestamp":1675296000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Peking University People\u2019s Hospital Scientific Research Development Funds","award":["PTU2021-06"],"award-info":[{"award-number":["PTU2021-06"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Short-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Native femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress\/strain cloud chart allowed the direction of stress\/strain to be assessed. Six BCFP models with different screw angles (5\u00b0, 10\u00b0, 15\u00b0, 20\u00b0, 25\u00b0, and 30\u00b0) and the Corail model were created. The stress\/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5\u00b0 stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Stress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5\u00b0 stem minimizes the stress shielding effect and presents a more bionic mechanical performance.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-023-06205-3","type":"journal-article","created":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T08:04:07Z","timestamp":1675325047000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis"],"prefix":"10.1186","volume":"24","author":[{"given":"Zhentao","family":"Ding","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanhua","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaomeng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Huan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dianying","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,2,2]]},"reference":[{"issue":"1","key":"6205_CR1","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1177\/1120700018810846","volume":"29","author":"T Karachalios","year":"2019","unstructured":"Karachalios T, Palaiochorlidis E, Komnos G. Clinical relevance of bone remodelling around conventional and conservative (short-stem) total hip arthroplasty implants. Hip Int. 2019;29(1):4\u20136.","journal-title":"Hip Int"},{"key":"6205_CR2","doi-asserted-by":"publisher","first-page":"104115","DOI":"10.1016\/j.jmbbm.2020.104115","volume":"113","author":"D Vogel","year":"2021","unstructured":"Vogel D, et al. Stress and strain distribution in femoral heads for hip resurfacing arthroplasty with different materials: A finite element analysis. J Mech Behav Biomed Mater. 2021;113:104115.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"6","key":"6205_CR3","doi-asserted-by":"publisher","first-page":"659","DOI":"10.3109\/17453674.2015.1067087","volume":"86","author":"M Salemyr","year":"2015","unstructured":"Salemyr M, et al. Lower periprosthetic bone loss and good fixation of an ultra-short stem compared to a conventional stem in uncemented total hip arthroplasty. Acta Orthop. 2015;86(6):659\u201366.","journal-title":"Acta Orthop"},{"issue":"5","key":"6205_CR4","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1302\/0301-620X.101B5.BJJ-2018-1199.R1","volume":"101","author":"S Lidder","year":"2019","unstructured":"Lidder S, Epstein D, Scott G. A systematic review of short metaphyseal loading cementless stems in hip arthroplasty. Bone Joint J. 2019;101(5):502\u201311.","journal-title":"Bone Joint J"},{"issue":"11_Supple_A","key":"6205_CR5","first-page":"57","volume":"95","author":"S Stulberg","year":"2013","unstructured":"Stulberg S, Patel R. Patel, The short stem: promises and pitfalls. Bone\u00a0Joint J. 2013;95(11_Supple_A):57\u201362.","journal-title":"Bone\u00a0Joint J"},{"key":"6205_CR6","doi-asserted-by":"crossref","unstructured":"Chatterjee, S., et al., Biomechanical analysis to probe role of bone condition and subject weight in stiffness customization of femoral stem for improved periprosthetic biomechanical response. Journal of Biomechanical Engineering, 2020. 142(10).","DOI":"10.1115\/1.4046973"},{"issue":"3","key":"6205_CR7","doi-asserted-by":"publisher","first-page":"250","DOI":"10.3109\/17453674.2014.908343","volume":"85","author":"J van Oldenrijk","year":"2014","unstructured":"van Oldenrijk J, et al. Revision rate after short-stem total hip arthroplasty: A systematic review of 49 clinical studies. Acta Orthop. 2014;85(3):250\u20138.","journal-title":"Acta Orthop"},{"issue":"3","key":"6205_CR8","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1007\/s00068-017-0895-2","volume":"44","author":"H Wacha","year":"2018","unstructured":"Wacha H, Domsel G, Herrmann E. Long-term follow-up of 1217 consecutive short-stem total hip arthroplasty (THA): a retrospective single-center experience. Eur J Trauma Emerg Surg. 2018;44(3):457\u201369.","journal-title":"Eur J Trauma Emerg Surg"},{"issue":"1 Suppl","key":"6205_CR9","first-page":"43","volume":"26","author":"G Maccagnano","year":"2022","unstructured":"Maccagnano G, et al. The effect of combined drug therapy in lateral fragility fractures of the femur: a prospective observational study. Eur Rev Med Pharmacol Sci. 2022;26(1 Suppl):43\u201352.","journal-title":"Eur Rev Med Pharmacol Sci"},{"issue":"3","key":"6205_CR10","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s10195-015-0335-1","volume":"16","author":"V Brinkmann","year":"2015","unstructured":"Brinkmann V, et al. A prospective randomized radiographic and dual-energy X-ray absorptiometric study of migration and bone remodeling after implantation of two modern short-stemmed femoral prostheses. J Orthop Traumatol. 2015;16(3):237\u201343.","journal-title":"J Orthop Traumatol"},{"issue":"4","key":"6205_CR11","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/j.jor.2017.08.007","volume":"14","author":"M Fischer","year":"2017","unstructured":"Fischer M, Beckmann NA, Simank HG. Bone remodelling around the Metha((R)) short stem implant - Clinical and dual-energy x-ray absorptiometry (DXA) results. J Orthop. 2017;14(4):525\u20139.","journal-title":"J Orthop"},{"issue":"8","key":"6205_CR12","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1016\/j.jbiomech.2009.02.030","volume":"42","author":"K Tsubota","year":"2009","unstructured":"Tsubota K, et al. Computer simulation of trabecular remodeling in human proximal femur using large-scale voxel FE models: Approach to understanding Wolff\u2019s law. J Biomech. 2009;42(8):1088\u201394.","journal-title":"J Biomech"},{"key":"6205_CR13","first-page":"1","volume":"1","author":"J Wolff","year":"1892","unstructured":"Wolff J. Das gesetz der transformation der knochen. A Hirshwald. 1892;1:1\u2013152.","journal-title":"A Hirshwald"},{"key":"6205_CR14","doi-asserted-by":"publisher","unstructured":"Khanuja HS, Banerjee S, Jain D, Pivec R, Mont MA. Short bone-conserving stems in cementless hip arthroplasty. J Bone Joint Surg Am. 2014;96(20):1742\u201352. https:\/\/doi.org\/10.2106\/JBJS.M.00780.","DOI":"10.2106\/JBJS.M.00780"},{"issue":"3","key":"6205_CR15","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s00264-004-0554-1","volume":"28","author":"A Leali","year":"2004","unstructured":"Leali A, Fetto JF. Preservation of femoral bone mass after total hip replacements with a lateral flare stem. Int Orthop. 2004;28(3):151\u20134.","journal-title":"Int Orthop"},{"issue":"3","key":"6205_CR16","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1007\/s10195-006-0141-x","volume":"7","author":"N Santori","year":"2006","unstructured":"Santori N, Lucidi M, Santori F. Proximal load transfer with a stemless uncemented femoral implant. J Orthop Traumatol. 2006;7(3):154\u201360.","journal-title":"J Orthop Traumatol"},{"issue":"18","key":"6205_CR17","doi-asserted-by":"publisher","first-page":"1646","DOI":"10.2106\/JBJS.19.01397","volume":"102","author":"MM Kheir","year":"2020","unstructured":"Kheir MM, Drayer NJ, Chen AF. An update on cementless femoral fixation in total hip arthroplasty. JBJS. 2020;102(18):1646\u201361.","journal-title":"JBJS"},{"issue":"10","key":"6205_CR18","doi-asserted-by":"publisher","first-page":"2169","DOI":"10.1097\/CORR.0000000000001940","volume":"479","author":"SM Melbye","year":"2021","unstructured":"Melbye SM, et al. How does implant survivorship vary with different corail femoral stem variants? Results of 51,212 cases with up to 30 years of follow-up from the Norwegian Arthroplasty Register. Clin Orthop Relat Res. 2021;479(10):2169\u201380.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"6205_CR19","doi-asserted-by":"publisher","first-page":"S6","DOI":"10.3928\/01477447-20150215-50","volume":"38","author":"F Falez","year":"2015","unstructured":"Falez F, Casella F, Papalia M. Current concepts, classification, and results in short stem hip arthroplasty. Orthopedics. 2015;38(3):S6\u201313.","journal-title":"Orthopedics"},{"issue":"7","key":"6205_CR20","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/S0021-9290(00)00036-1","volume":"33","author":"H Weinans","year":"2000","unstructured":"Weinans H, et al. Sensitivity of periprosthetic stress-shielding to load and the bone density\u2013modulus relationship in subject-specific finite element models. J Biomech. 2000;33(7):809\u201317.","journal-title":"J Biomech"},{"issue":"5","key":"6205_CR21","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1002\/jor.1100090507","volume":"9","author":"M Ciarelli","year":"1991","unstructured":"Ciarelli M, et al. Evaluation of orthogonal mechanical properties and density of human trabecular bone from the major metaphyseal regions with materials testing and computed tomography. J Orthop Res. 1991;9(5):674\u201382.","journal-title":"J Orthop Res"},{"issue":"6","key":"6205_CR22","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1515\/bmte.1995.40.6.175","volume":"40","author":"J Schmitt","year":"1995","unstructured":"Schmitt J, et al. Use of voxel-oriented femur models for stress analysis. Generation, calculation and validation of CT-based FEM models. Biomedizinische Technik. Biomed Engin. 1995;40(6):175\u201381.","journal-title":"Biomed Engin"},{"key":"6205_CR23","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.clinbiomech.2018.11.002","volume":"61","author":"M Lerch","year":"2019","unstructured":"Lerch M, et al. \u2018Pre-launch\u2019finite element analysis of a short-stem total hip arthroplasty system consisting of two implant types. Clin Biomech. 2019;61:31\u20137.","journal-title":"Clin Biomech"},{"issue":"8","key":"6205_CR24","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1002\/jor.22349","volume":"31","author":"R Bieger","year":"2013","unstructured":"Bieger R, et al. Biomechanics of a short stem: in vitro primary stability and stress shielding of a conservative cementless hip stem. J Orthop Res. 2013;31(8):1180\u20136.","journal-title":"J Orthop Res"},{"issue":"6","key":"6205_CR25","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1007\/s00264-020-04895-1","volume":"45","author":"J van Loon","year":"2021","unstructured":"van Loon J, et al. Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up. Int Orthop. 2021;45(6):1447\u201354.","journal-title":"Int Orthop"},{"issue":"7","key":"6205_CR26","doi-asserted-by":"publisher","first-page":"917","DOI":"10.1016\/S0021-9290(00)00225-6","volume":"34","author":"J Stolk","year":"2001","unstructured":"Stolk J, Verdonschot N, Huiskes R. Hip-joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. J Biomech. 2001;34(7):917\u201326.","journal-title":"J Biomech"},{"issue":"1","key":"6205_CR27","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/1350-4533(95)00033-X","volume":"18","author":"M Lengsfeld","year":"1996","unstructured":"Lengsfeld M, et al. Sensitivity of femoral strain pattern analyses to resultant and muscle forces at the hip joint. Med Eng Phys. 1996;18(1):70\u20138.","journal-title":"Med Eng Phys"},{"issue":"8","key":"6205_CR28","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1302\/0301-620X.88B8.17567","volume":"88","author":"KL Ong","year":"2006","unstructured":"Ong KL, et al. Biomechanics of the Birmingham hip resurfacing arthroplasty. J Bone Joint Surg Br. 2006;88(8):1110\u20135.","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"6205_CR29","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1016\/j.jbiomech.2014.12.021","volume":"48","author":"DR Sumner","year":"2015","unstructured":"Sumner DR. Long-term implant fixation and stress-shielding in total hip replacement. J Biomech. 2015;48(5):797\u2013800.","journal-title":"J Biomech"},{"key":"6205_CR30","doi-asserted-by":"crossref","unstructured":"Taylor, M. Finite element analysis of the resurfaced femoral head. in PROCEEDINGS-INSTITUTION OF MECHANICAL ENGINEERS PART H JOURNAL OF ENGINEERING IN MEDICINE. 2006. Citeseer.","DOI":"10.1243\/095441105X93631"},{"key":"6205_CR31","unstructured":"Zhang, X., et al., Finite element analysis of biomechanical properties of bionic surface hip prosthesis. Chinese Journal of Orthopaedics, 2021: p. 1795\u20131802."},{"key":"6205_CR32","doi-asserted-by":"crossref","unstructured":"Parchi PD, Cervi V, Piolanti N, Ciapini G, Andreani L, Castellini I, Poggetti A, Lisanti M. Densitometric evaluation of periprosthetic bone remodeling. Clin Cases Miner Bone Metab. 2014;11(3):226\u201331.","DOI":"10.11138\/ccmbm\/2014.11.3.226"},{"issue":"1","key":"6205_CR33","doi-asserted-by":"publisher","first-page":"26","DOI":"10.5301\/hipint.5000413","volume":"27","author":"AR Knutsen","year":"2017","unstructured":"Knutsen AR, et al. Periprosthetic femoral bone loss in total hip arthroplasty: systematic analysis of the effect of stem design. Hip Int. 2017;27(1):26\u201334.","journal-title":"Hip Int"},{"issue":"4","key":"6205_CR34","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1055\/s-0030-1250151","volume":"148","author":"C G\u00f6tze","year":"2010","unstructured":"G\u00f6tze C, Ehrenbrink J, Ehrenbrink H. Is there a bone-preserving bone remodelling in short-stem prosthesis? DEXA analysis with the Nanos total hip arthroplasty. Z Orthop Unfall. 2010;148(4):398\u2013405.","journal-title":"Z Orthop Unfall"},{"issue":"1","key":"6205_CR35","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-020-02027-4","volume":"15","author":"SG Yan","year":"2020","unstructured":"Yan SG, et al. Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study. J Orthop Surg Res. 2020;15(1):1\u201310.","journal-title":"J Orthop Surg Res"},{"issue":"9","key":"6205_CR36","doi-asserted-by":"publisher","first-page":"2077","DOI":"10.1007\/s00264-017-3691-z","volume":"42","author":"SG Yan","year":"2018","unstructured":"Yan SG, et al. Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review. Int Orthop. 2018;42(9):2077\u201386.","journal-title":"Int Orthop"},{"key":"6205_CR37","first-page":"346","volume":"30","author":"PD Parchi","year":"2017","unstructured":"Parchi PD, et al. Evaluation of the Effects of the Metha\u00ae Short Stem on Periprosthetic Bone Remodelling in Total Hip Arthroplasties: Results at 48 Months. Surg Technol Int. 2017;30:346\u201351.","journal-title":"Surg Technol Int"},{"issue":"6","key":"6205_CR38","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1007\/s00264-009-0884-0","volume":"34","author":"RP Pitto","year":"2010","unstructured":"Pitto RP, et al. Femoral bone density changes after total hip arthroplasty with uncemented taper-design stem: a five year follow-up study. Int Orthop. 2010;34(6):783\u20137.","journal-title":"Int Orthop"},{"key":"6205_CR39","doi-asserted-by":"publisher","unstructured":"Cavalcante JGT, Marqueti RC, Geremia JM, de Sousa Neto IV, Baroni BM, Silbernagel KG, et al. The Effect of Quadriceps Muscle Length on Maximum Neuromuscular Electrical Stimulation Evoked Contraction, Muscle Architecture, and Tendon-Aponeurosis Stiffness. Front Physiol. 2021;12:633589. https:\/\/doi.org\/10.3389\/fphys.2021.633589.","DOI":"10.3389\/fphys.2021.633589"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06205-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-023-06205-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06205-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T08:06:08Z","timestamp":1675325168000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-023-06205-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,2]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["6205"],"URL":"https:\/\/doi.org\/10.1186\/s12891-023-06205-3","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,2]]},"assertion":[{"value":"6 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 February 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the institutional review board of Peking University People's Hospital Ethics Review Committee (2022PHB237-001) and was performed in accordance with the Declaration of Helsinki. The volunteer gave his informed consent to have all his data, images and demographics.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The volunteer gave his informed consent to have all his clinical data for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"89"}}