{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T06:41:36Z","timestamp":1778136096552,"version":"3.51.4"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,8]],"date-time":"2023-03-08T00:00:00Z","timestamp":1678233600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,8]],"date-time":"2023-03-08T00:00:00Z","timestamp":1678233600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>This study represents the first finite element (FE) analysis of long-instrumented spinal fusion from the thoracic vertebrae to the pelvis in the context of adult spinal deformity (ASD) with osteoporosis. We aimed to evaluate the von Mises stress in long spinal instrumentation for models that differ in terms of spinal balance, fusion length, and implant type.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this three-dimensional FE analysis, FE models were developed based on computed tomography images from a patient with osteoporosis. The von Mises stress was compared for three different sagittal vertical axes (SVAs) (0, 50, and 100\u00a0mm), two different fusion lengths (from the pelvis to the second [T2-S2AI] or 10th thoracic vertebra [T10-S2AI]), and two different types of implants (pedicle screw or transverse hook) in the upper instrumented vertebra (UIV). We created 12 models based on combinations of these conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The overall von Mises stress was 3.1 times higher on the vertebrae and 3.9 times higher on implants for the 50-mm SVA models than that for the 0-mm SVA models. Similarly, the values were 5.0 times higher on the vertebrae and 6.9 times higher on implants for the 100-mm SVA models than that for the 0-mm SVA models. Higher SVA was associated with greater stress below the fourth lumbar vertebrae and implants. In the T2-S2AI models, the peaks of vertebral stress were observed at the UIV, at the apex of kyphosis, and below the lower lumbar spine. In the T10-S2AI models, the peaks of stress were observed at the UIV and below the lower lumbar region. The von Mises stress in the UIV was also higher for the screw models than for the hook models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Higher SVA is associated with greater von Mises stress on the vertebrae and implants. The stress on the UIV is greater for the T10-S2AI models than for the T2-S2AI models. Using transverse hooks instead of screws at the UIV may reduce stress in patients with osteoporosis.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-023-06290-4","type":"journal-article","created":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T16:11:02Z","timestamp":1679847062000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Biomechanical investigation of long spinal fusion models using three-dimensional finite element analysis"],"prefix":"10.1186","volume":"24","author":[{"given":"Norihiro","family":"Oku","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoru","family":"Demura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daisuke","family":"Tawara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Satoshi","family":"Kato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuya","family":"Shinmura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noriaki","family":"Yokogawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noritaka","family":"Yonezawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takaki","family":"Shimizu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryo","family":"Kitagawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Handa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annen","family":"Ryohei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Tsuchiya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,3,8]]},"reference":[{"issue":"Supplement 4","key":"6290_CR1","doi-asserted-by":"publisher","first-page":"S75","DOI":"10.1227\/NEU.0000000000000938","volume":"77","author":"T Ailon","year":"2015","unstructured":"Ailon T, Smith JS, Shaffrey CI, Lenke LG, Brodke D, Harrop JS, et al. Degenerative spinal deformity. Neurosurgery. 2015;77(Supplement 4):S75-91.","journal-title":"Neurosurgery"},{"key":"6290_CR2","doi-asserted-by":"publisher","first-page":"E687","DOI":"10.1097\/BRS.0b013e318246d4f2","volume":"37","author":"PJ Cahill","year":"2012","unstructured":"Cahill PJ, Wang W, Asghar J, Booker R, Betz RB, Ramcey C, et al. The use of a transition rod may prevent proximal junctional kyphosis in the thoracic spine after scoliosis surgery: a finite element analysis. Spine (Phila Pa 1976). 2012;37:E687-95.","journal-title":"Spine (Phila Pa 1976)"},{"key":"6290_CR3","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/0141-5425(90)90022-F","volume":"12","author":"JH Keyak","year":"1990","unstructured":"Keyak JH, Meagher JM, Skinner HB, Mote CD Jr. Automated three-dimensional finite element modelling of bone: a new method. J Biomed Eng. 1990;12:389\u201397.","journal-title":"J Biomed Eng"},{"key":"6290_CR4","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/S0021-9290(97)00123-1","volume":"31","author":"JH Keyak","year":"1998","unstructured":"Keyak JH, Rossi SA, Jones KA, Skinner HB. Prediction of femoral fracture load using automated finite element modeling. J Biomech. 1998;31:125\u201333.","journal-title":"J Biomech"},{"key":"6290_CR5","first-page":"3225","volume":"15","author":"D Nakashima","year":"2018","unstructured":"Nakashima D, Kanchiku T, Nishida N, Ito S, Ohgi J, Suzuki H, et al. Finite element analysis of compression fractures at the thoracolumbar junction using models constructed from medical images. Exp Ther Med. 2018;15:3225\u201330.","journal-title":"Exp Ther Med"},{"key":"6290_CR6","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1299\/jbse.13-00163","volume":"9","author":"D Tawara","year":"2014","unstructured":"Tawara D, Noro K, Tsujikami T, Okamoto Y, Murakami H. Nonlinear mechanical analysis of posterior spinal instrumentation for osteoporotic vertebra: effects of mechanical properties of the rod on the failure risks around the screw. J Biomech Sci Eng. 2014;9:13\u201300163.","journal-title":"J Biomech Sci Eng"},{"key":"6290_CR7","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.jmbbm.2009.03.001","volume":"3","author":"D Tawara","year":"2010","unstructured":"Tawara D, Sakamoto J, Murakami H, Kawahari N, Oda J, Tomita K. Mechanical evaluation by patient-specific finite element analyses demonstrates therapeutic effects for osteoporotic vertebrae. J Mech Behav Biomed Mater. 2010;3:31\u201340.","journal-title":"J Mech Behav Biomed Mater"},{"key":"6290_CR8","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1299\/jbse.6.248","volume":"6","author":"D Tawara","year":"2011","unstructured":"Tawara D, Sakamoto J, Murakami H, Kawahara N, Tomita K. Patient-specific finite element analyses detect significant mechanical therapeutic effects on osteoporotic vertebrae during a three-year treatment. J Biomech Sci Eng. 2011;6:248\u201361.","journal-title":"J Biomech Sci Eng"},{"key":"6290_CR9","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1007\/s43390-020-00052-1","volume":"8","author":"W Cho","year":"2020","unstructured":"Cho W, Wang W, Bucklen B. The role of sagittal alignment in predicting major failure of lumbopelvic instrumentation: a biomechanical validation of lumbopelvic failure classification. Spine Deform. 2020;8:561\u20138.","journal-title":"Spine Deform"},{"key":"6290_CR10","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.wneu.2017.02.126","volume":"102","author":"M Luo","year":"2017","unstructured":"Luo M, Wang P, Wang W, Shen M, Xu G, Xia L. Upper thoracic versus lower thoracic as site of upper instrumented vertebrae for long fusion surgery in adult spinal deformity: a meta-analysis of proximal junctional kyphosis. World Neurosurg. 2017;102:200\u20138.","journal-title":"World Neurosurg"},{"key":"6290_CR11","doi-asserted-by":"publisher","first-page":"E500","DOI":"10.1097\/BRS.0000000000000222","volume":"39","author":"M Cammarata","year":"2014","unstructured":"Cammarata M, Aubin C\u00c9, Wang X, Mac-Thiong J-M. Biomechanical risk factors for proximal junctional kyphosis: a detailed numerical analysis of surgical instrumentation variables. Spine (Phila Pa 1976). 2014;39:E500-7.","journal-title":"Spine (Phila Pa 1976)"},{"key":"6290_CR12","doi-asserted-by":"publisher","first-page":"622","DOI":"10.31616\/asj.2018.12.4.622","volume":"12","author":"A Matsumura","year":"2018","unstructured":"Matsumura A, Namikawa T, Kato M, Oyama S, Hori Y, Yabu A, et al. Effect of different types of upper instrumented vertebrae instruments on proximal junctional kyphosis following adult spinal deformity surgery: pedicle screw versus transverse process hook. Asian Spine J. 2018;12:622\u201331.","journal-title":"Asian Spine J"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06290-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-023-06290-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06290-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T16:11:06Z","timestamp":1679847066000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-023-06290-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,8]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["6290"],"URL":"https:\/\/doi.org\/10.1186\/s12891-023-06290-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2198184\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,8]]},"assertion":[{"value":"24 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Ethics Committee of Kanazawa University Hospital approved the study and the use of computed tomography data for this study (Approval No. 1748). Informed consent was obtained from the patient whose computed tomography data were used in this study. All methods were carried out in accordance with relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from all study participants for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"175"}}