{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T21:11:48Z","timestamp":1793308308248,"version":"4.5.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,4,14]],"date-time":"2023-04-14T00:00:00Z","timestamp":1681430400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,14]],"date-time":"2023-04-14T00:00:00Z","timestamp":1681430400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Maximal isometric muscle strength (MIMS) assessment is a key component of physiotherapists\u2019 work. Hand-held dynamometry (HHD) is a simple and quick method to obtain quantified MIMS values that have been shown to be valid, reliable, and more responsive than manual muscle testing. However, the lack of MIMS reference values for several muscle groups in healthy adults with well-known psychometric properties limits the use and the interpretation of these measures obtained with HHD in clinic.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To determine the intra- and inter-rater reliability, standard error of measurement (SEM) and minimal detectable change (MDC) of MIMS torque values obtained with HHD.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Intra and Inter-rater Reliability Study. The MIMS torque of 17 muscle groups was assessed by two independent raters at three different times in 30 healthy adults using a standardized HHD protocol using the MEDup\u2122 (Atlas Medic, Qu\u00e9bec, Canada). Participants were excluded if they presented any of the following criteria: 1) participation in sport at a competitive level; 2) degenerative or neuromusculoskeletal disease that could affect torque measurements; 3) traumatic experience or disease in the previous years that could affect their muscle function; and 4) use of medication that could impact muscle strength (e.g., muscle relaxants, analgesics, opioids) at the time of the evaluation. Intra- and inter-rater reliability were determined using two-way mixed (intra) and random effects (inter) absolute agreement intraclass correlation coefficients (ICC: 95% confidence interval)\u00a0models. SEM and MDC were calculated from these data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Intra- and inter-rater reliability were excellent with ICC (95% confidence interval) varying from 0.90 to 0.99 (0.85\u20130.99) and 0.89 to 0.99 (0.55\u20130.995), respectively. Absolute SEM and MDC for intra-rater reliability ranged from 0.14 to 3.20 Nm and 0.38 to 8.87 Nm, respectively, and from 0.17 to 5.80 Nm and 0.47 to 16.06 Nm for inter-rater reliability, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The excellent reliability obtained in this study suggest that the use of such a standardized HHD protocol is a method of choice for MIMS torque measurements in both clinical and research settings. And the identification of the now known metrological qualities of such a protocol should encourage and promote the optimal use of manual dynamometry.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-023-06400-2","type":"journal-article","created":{"date-parts":[[2023,4,14]],"date-time":"2023-04-14T05:02:59Z","timestamp":1681448579000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Psychometric properties of a standardized protocol of muscle strength assessment by hand-held dynamometry in healthy adults: a reliability study"],"prefix":"10.1186","volume":"24","author":[{"given":"Marika","family":"Morin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luc J.","family":"H\u00e9bert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Perron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c9milie","family":"Petitclerc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shanna-Rose","family":"Lake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elise","family":"Duchesne","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,4,14]]},"reference":[{"issue":"6","key":"6400_CR1","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1007\/BF03327406","volume":"16","author":"S Al Snih","year":"2004","unstructured":"Al Snih S, Markides KS, Ottenbacher KJ, Raji MA. Hand grip strength and incident ADL disability in elderly Mexican Americans over a seven-year period. Aging Clin Exp Res. 2004;16(6):481\u20136.","journal-title":"Aging Clin Exp Res"},{"issue":"3","key":"6400_CR2","first-page":"258","volume":"19","author":"F Buckinx","year":"2019","unstructured":"Buckinx F, Croisier JL, Charles A, Petermans J, Reginster JY, Rygaert X, et al. Normative data for isometric strength of 8 different muscle groups and their usefulness as a predictor of loss of autonomy among physically active nursing home residents: the SENIOR cohort. J Musculoskelet Neuronal Interact. 2019;19(3):258\u201365.","journal-title":"J Musculoskelet Neuronal Interact"},{"issue":"10","key":"6400_CR3","doi-asserted-by":"publisher","first-page":"e0165127","DOI":"10.1371\/journal.pone.0165127","volume":"11","author":"A van der Vorst","year":"2016","unstructured":"van der Vorst A, Zijlstra GA, Witte N, Duppen D, Stuck AE, Kempen GI, et al. Limitations in activities of daily living in community-dwelling people aged 75 and over: a systematic literature review of risk and protective factors. PLoS One. 2016;11(10):e0165127.","journal-title":"PLoS One"},{"issue":"1","key":"6400_CR4","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1002\/jcsm.12502","volume":"11","author":"DXM Wang","year":"2020","unstructured":"Wang DXM, Yao J, Zirek Y, Reijnierse EM, Maier AB. Muscle mass, strength, and physical performance predicting activities of daily living: a meta-analysis. J Cachexia Sarcopenia Muscle. 2020;11(1):3\u201325.","journal-title":"J Cachexia Sarcopenia Muscle"},{"issue":"2","key":"6400_CR5","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1097\/00002060-199903000-00007","volume":"78","author":"S Nadeau","year":"1999","unstructured":"Nadeau S, Arsenault AB, Gravel D, Bourbonnais D. Analysis of the clinical factors determining natural and maximal gait speeds in adults with A Stroke1. Am J Phys Med Rehabil. 1999;78(2):123\u201330.","journal-title":"Am J Phys Med Rehabil"},{"issue":"1","key":"6400_CR6","doi-asserted-by":"crossref","first-page":"49","DOI":"10.2340\/1650197719974955","volume":"29","author":"S Nadeau","year":"1997","unstructured":"Nadeau S, Gravel D, Arsenault A. Relationships between torque, velocity and power output during plantarflexion in healthy subjects. Scand J Rehabil Med. 1997;29(1):49\u201355.","journal-title":"Scand J Rehabil Med"},{"issue":"4","key":"6400_CR7","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1109\/86.547940","volume":"4","author":"S Nadeau","year":"1996","unstructured":"Nadeau S, Gravel D, Arsenault AB, Bourbonnais D. A mechanical model to study the relationship between gait speed and muscular strength. IEEE Trans Rehabil Eng. 1996;4(4):386\u201394.","journal-title":"IEEE Trans Rehabil Eng"},{"issue":"3","key":"6400_CR8","doi-asserted-by":"publisher","first-page":"321","DOI":"10.3233\/JND-180311","volume":"5","author":"LJ H\u00e9bert","year":"2018","unstructured":"H\u00e9bert LJ, Vial C, Hogrel JY, Puymirat J. Ankle strength impairments in myotonic dystrophy type 1: a five-year follow-up. J Neuromuscul Dis. 2018;5(3):321\u201330.","journal-title":"J Neuromuscul Dis"},{"issue":"5","key":"6400_CR9","first-page":"472","volume":"3","author":"T Stark","year":"2011","unstructured":"Stark T, Walker B, Phillips JK, Fejer R, Beck R. Hand-held dynamometry correlation with the gold standard isokinetic dynamometry: a systematic review. Physical Medicine & Rehabilitation. 2011;3(5):472\u20139.","journal-title":"Physical Medicine & Rehabilitation"},{"issue":"12","key":"6400_CR10","doi-asserted-by":"publisher","first-page":"996","DOI":"10.3390\/diagnostics10120996","volume":"10","author":"FN Bittmann","year":"2020","unstructured":"Bittmann FN, Dech S, Aehle M, Schaefer LV. Manual muscle testing-force profiles and their reproducibility. Diagnostics (Basel). 2020;10(12):996.","journal-title":"Diagnostics (Basel)."},{"issue":"1","key":"6400_CR11","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/1471-2474-11-72","volume":"11","author":"LJ H\u00e9bert","year":"2010","unstructured":"H\u00e9bert LJ, Remec JF, Saulnier J, Vial C, Puymirat J. The use of muscle strength assessed with handheld dynamometers as a non-invasive biological marker in myotonic dystrophy type 1 patients: a multicenter study. BMC Musculoskelet Disord. 2010;11(1):72.","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"6400_CR12","doi-asserted-by":"publisher","first-page":"215","DOI":"10.3233\/JND-170291","volume":"5","author":"\u00c9 Petitclerc","year":"2018","unstructured":"Petitclerc \u00c9, H\u00e9bert LJ, Mathieu J, Desrosiers J, Gagnon C. Relationships between lower limb muscle strength impairments and physical limitations in DM1. J Neuromuscul Dis. 2018;5(2):215\u201324.","journal-title":"J Neuromuscul Dis"},{"issue":"1","key":"6400_CR13","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1067\/mse.2002.119852","volume":"11","author":"K Hayes","year":"2002","unstructured":"Hayes K, Walton JR, Szomor ZL, Murrell GA. Reliability of 3 methods for assessing shoulder strength. J Shoulder Elbow Surg. 2002;11(1):33\u20139.","journal-title":"J Shoulder Elbow Surg"},{"issue":"3","key":"6400_CR14","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1519\/JSC.0b013e3181aa36b8","volume":"24","author":"CM Arnold","year":"2010","unstructured":"Arnold CM, Warkentin KD, Chilibeck PD, Magnus CR. The reliability and validity of handheld dynamometry for the measurement of lower-extremity muscle strength in older adults. J Strength Cond Res. 2010;24(3):815\u201324.","journal-title":"J Strength Cond Res"},{"issue":"3","key":"6400_CR15","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1111\/cpf.12300","volume":"37","author":"F Buckinx","year":"2017","unstructured":"Buckinx F, Croisier JL, Reginster JY, Dardenne N, Beaudart C, Slomian J, et al. Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population. Clin Physiol Funct Imaging. 2017;37(3):332\u201340.","journal-title":"Clin Physiol Funct Imaging"},{"issue":"10","key":"6400_CR16","doi-asserted-by":"publisher","first-page":"e0140822","DOI":"10.1371\/journal.pone.0140822","volume":"10","author":"BF Mentiplay","year":"2015","unstructured":"Mentiplay BF, Perraton LG, Bower KJ, Adair B, Pua YH, Williams GP, et al. Assessment of lower limb muscle strength and power using hand-held and fixed dynamometry: a reliability and validity study. PLoS One. 2015;10(10):e0140822.","journal-title":"PLoS One"},{"issue":"2","key":"6400_CR17","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1179\/108331905X55730","volume":"10","author":"MJ Kolber","year":"2005","unstructured":"Kolber MJ, Cleland JA. Strength testing using hand-held dynamometry. Phys Ther Rev. 2005;10(2):99\u2013112.","journal-title":"Phys Ther Rev"},{"key":"6400_CR18","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1515\/med-2017-0052","volume":"12","author":"C Chamorro","year":"2017","unstructured":"Chamorro C, Armijo-Olivo S, De la Fuente C, Fuentes J, Javier CL. Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: systematic review and meta-analysis. Open Medicine (Wars). 2017;12:359\u201375.","journal-title":"Open Medicine (Wars)"},{"issue":"11","key":"6400_CR19","doi-asserted-by":"publisher","first-page":"3054","DOI":"10.1589\/jpts.28.3054","volume":"28","author":"T Awatani","year":"2016","unstructured":"Awatani T, Morikita I, Shinohara J, Mori S, Nariai M, Tatsumi Y, et al. Intra- and inter-rater reliability of isometric shoulder extensor and internal rotator strength measurements performed using a hand-held dynamometer. J Phys Ther Sci. 2016;28(11):3054\u20139.","journal-title":"J Phys Ther Sci"},{"issue":"3","key":"6400_CR20","doi-asserted-by":"publisher","first-page":"e0194531","DOI":"10.1371\/journal.pone.0194531","volume":"13","author":"P Baschung Pfister","year":"2018","unstructured":"Baschung Pfister P, de Bruin ED, Sterkele I, Maurer B, de Bie RA, Knols RH. Manual muscle testing and hand-held dynamometry in people with inflammatory myopathy: an intra- and interrater reliability and validity study. PLoS One. 2018;13(3):e0194531.","journal-title":"PLoS One"},{"issue":"10","key":"6400_CR21","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1016\/j.jse.2014.01.006","volume":"23","author":"AM Cools","year":"2014","unstructured":"Cools AM, De Wilde L, Van Tongel A, Ceyssens C, Ryckewaert R, Cambier DC. Measuring shoulder external and internal rotation strength and range of motion: comprehensive intra-rater and inter-rater reliability study of several testing protocols. J Shoulder Elbow Surg. 2014;23(10):1454\u201361.","journal-title":"J Shoulder Elbow Surg"},{"issue":"3","key":"6400_CR22","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.physio.2015.10.002","volume":"102","author":"L Dowman","year":"2016","unstructured":"Dowman L, McDonald CF, Hill CJ, Lee A, Barker K, Boote C, et al. Reliability of the hand held dynamometer in measuring muscle strength in people with interstitial lung disease. Physiotherapy. 2016;102(3):249\u201355.","journal-title":"Physiotherapy"},{"key":"6400_CR23","doi-asserted-by":"crossref","unstructured":"Gonz\u00e1lez-Rosal\u00e9n J, Ben\u00edtez-Mart\u00ednez JC, Medina-Mirapeix F, Cuerda-Del Pino A, Cervell\u00f3 A, Mart\u00edn-San Agust\u00edn R. Intra- and inter-rater reliability of strength measurements using a pull hand-held dynamometer fixed to the examiner's body and comparison with push dynamometry. Diagnostics (Basel). 2021;11(7).","DOI":"10.3390\/diagnostics11071230"},{"key":"6400_CR24","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.jbiomech.2018.04.032","volume":"75","author":"BF Mentiplay","year":"2018","unstructured":"Mentiplay BF, Tan D, Williams G, Adair B, Pua YH, Bower KJ, et al. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: test-retest reliability and relationship with gait velocity after stroke. J Biomech. 2018;75:171\u20135.","journal-title":"J Biomech"},{"key":"6400_CR25","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9780511996214","volume-title":"Measurement in medicine: a practical guide","author":"HC de Vet","year":"2011","unstructured":"de Vet HC, Terwee CB, Mokkink LB, Knol DL. Measurement in medicine: a practical guide. Cambridge: Cambridge University Press; 2011."},{"issue":"2","key":"6400_CR26","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1123\/jsr.17.2.160","volume":"17","author":"BM Kelln","year":"2008","unstructured":"Kelln BM, McKeon PO, Gontkof LM, Hertel J. Hand-held dynamometry: reliability of lower extremity muscle testing in healthy, physically active, young adults. J Sport Rehabil. 2008;17(2):160\u201370.","journal-title":"J Sport Rehabil"},{"issue":"3 Pt 1","key":"6400_CR27","doi-asserted-by":"publisher","first-page":"899","DOI":"10.2466\/pms.1999.88.3.899","volume":"88","author":"RW Bohannon","year":"1999","unstructured":"Bohannon RW. Intertester reliability of hand-held dynamometry: a concise summary of published research. Percept Mot Skills. 1999;88(3 Pt 1):899\u2013902.","journal-title":"Percept Mot Skills"},{"issue":"1","key":"6400_CR28","first-page":"100172","volume":"4","author":"M Morin","year":"2022","unstructured":"Morin M, Duchesne E, Bernier J, Blanchette P, Langlois D, Hebert LJ. What is known about muscle strength reference values for adults measured by hand-held dynamometry: a scoping review. Arch Rehabil Res Clin Transl. 2022;4(1):100172.","journal-title":"Arch Rehabil Res Clin Transl"},{"issue":"3","key":"6400_CR29","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1097\/PEP.0b013e318227ccff","volume":"23","author":"LJ H\u00e9bert","year":"2011","unstructured":"H\u00e9bert LJ, Maltais DB, Lepage C, Saulnier J, Cr\u00eate M, Perron M. Isometric muscle strength in youth assessed by hand-held dynamometry: a feasibility, reliability, and validity study. Pediatr Phys Ther. 2011;23(3):289\u201399.","journal-title":"Pediatr Phys Ther"},{"issue":"2","key":"6400_CR30","doi-asserted-by":"publisher","first-page":"233","DOI":"10.3233\/JND-190388","volume":"6","author":"MP Roussel","year":"2019","unstructured":"Roussel MP, H\u00e9bert LJ, Duchesne E. Intra-rater reliability and concurrent validity of quantified muscle testing for maximal knee extensors strength in men with myotonic dystrophy type 1. J Neuromuscul Dis. 2019;6(2):233\u201340.","journal-title":"J Neuromuscul Dis"},{"key":"6400_CR31","unstructured":"Bujang MA, Baharum N. A simplified guide to determination of sample size requirements for estimating the value of intraclass correlation coefficient: a review. Arch Orofac Sci. 2017;12(1)."},{"issue":"2","key":"6400_CR32","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155\u201363.","journal-title":"J Chiropr Med"},{"key":"6400_CR33","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.ptsp.2019.04.011","volume":"38","author":"LL Florencio","year":"2019","unstructured":"Florencio LL, Martins J, da Silva MRB, da Silva JR, Bellizzi GL, Bevilaqua-Grossi D. Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement. Phys Ther Sport. 2019;38:115\u201322.","journal-title":"Phys Ther Sport"},{"issue":"9","key":"6400_CR34","doi-asserted-by":"publisher","first-page":"809","DOI":"10.4085\/1062-6050-52.6.04","volume":"52","author":"J Martins","year":"2017","unstructured":"Martins J, da Silva JR, da Silva MRB, Bevilaqua-Grossi D. Reliability and validity of the belt-stabilized handheld dynamometer in hip- and knee-strength tests. J Athl Train. 2017;52(9):809\u201319.","journal-title":"J Athl Train"},{"issue":"6","key":"6400_CR35","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1589\/jpts.27.1799","volume":"27","author":"SG Kim","year":"2015","unstructured":"Kim SG, Lee YS. The intra- and inter-rater reliabilities of lower extremity muscle strength assessment of healthy adults using a hand held dynamometer. J Phys Ther Sci. 2015;27(6):1799\u2013801.","journal-title":"J Phys Ther Sci"},{"issue":"12","key":"6400_CR36","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1016\/S0003-9993(97)90311-7","volume":"78","author":"DD Kilmer","year":"1997","unstructured":"Kilmer DD, McCrory MA, Wright NC, Rosko RA, Kim HR, Aitkens SG. Hand-held dynamometry reliability in persons with neuropathic weakness. Arch Phys Med Rehabil. 1997;78(12):1364\u20138.","journal-title":"Arch Phys Med Rehabil"},{"issue":"4","key":"6400_CR37","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1111\/j.1600-0838.2011.01405.x","volume":"23","author":"K Thorborg","year":"2013","unstructured":"Thorborg K, Bandholm T, Schick M, Jensen J, H\u00f6lmich P. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength. Scand J Med Sci Sports. 2013;23(4):487\u201393.","journal-title":"Scand J Med Sci Sports"},{"issue":"2","key":"6400_CR38","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.ptsp.2014.05.004","volume":"16","author":"A Cejudo","year":"2015","unstructured":"Cejudo A, Sainz de Baranda P, Ayala F, Santonja F. Test-retest reliability of seven common clinical tests for assessing lower extremity muscle flexibility in futsal and handball players. Phys Ther Sport. 2015;16(2):107\u201313.","journal-title":"Phys Ther Sport"},{"key":"6400_CR39","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.ptsp.2016.07.001","volume":"21","author":"KL Holt","year":"2016","unstructured":"Holt KL, Raper DP, Boettcher CE, Waddington GS, Drew MK. Hand-held dynamometry strength measures for internal and external rotation demonstrate superior reliability, lower minimal detectable change and higher correlation to isokinetic dynamometry than externally-fixed dynamometry of the shoulder. Phys Ther Sport. 2016;21:75\u201381.","journal-title":"Phys Ther Sport"},{"issue":"3","key":"6400_CR40","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1007\/s00167-012-2115-2","volume":"21","author":"K Thorborg","year":"2013","unstructured":"Thorborg K, Bandholm T, H\u00f6lmich P. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable. Knee Surg Sports Traumatol Arthrosc. 2013;21(3):550\u20135.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"6400_CR41","unstructured":"Desquilbet L. Guide pratique de validation statistique de m\u00e9thodes de mesure : r\u00e9p\u00e9tabilit\u00e9, reproductibilit\u00e9, et concordance. [Quantification statistique de la r\u00e9p\u00e9tabilit\u00e9, reproductibilit\u00e9, et concordance de m\u00e9thodes de mesure]. In press 2019."}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06400-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-023-06400-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-023-06400-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,18]],"date-time":"2024-10-18T04:33:46Z","timestamp":1729226026000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-023-06400-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,14]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["6400"],"URL":"https:\/\/doi.org\/10.1186\/s12891-023-06400-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2346193\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,14]]},"assertion":[{"value":"5 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The Authors received approval from a properly constituted ethics committee. The study was approved by the <i>Ethics Committee of the Integrated University Center of health and social services (CIUSSS) of the Capitale-Nationale<\/i>. The study complies with the Declaration of Helsinki. Written informed consent was obtained from each participant prior to the first assessment session.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent was obtained from the subject for publication of images in an online open-access publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"294"}}