{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T09:52:51Z","timestamp":1767174771862,"version":"build-2238731810"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T00:00:00Z","timestamp":1715212800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T00:00:00Z","timestamp":1715212800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>External fixation is widely used in the treatment of traumatic fractures; however, orthopedic surgeons encounter challenges in deciding the optimal time for fixator removal. The axial load-share ratio (LS) of the fixator is a quantitative index to evaluate the stiffness of callus healing. This paper introduces an innovative method for measuring the LS and assesses the method\u2019s feasibility and efficacy. Based on a novel hexapod LS-measurement system, the proposed method is to improve the convenience and precision of measuring LS in vivo, hence facilitating the safe removal of external fixators.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A novel hexapod system is introduced, including its composition, theoretical model, and method for LS measurement. We conducted a retrospective study on 82 patients with tibial fractures treated by the Taylor Spatial Frame in our hospital from September 2018 to June 2020, of which 35 took LS measurements with our novel method (Group I), and 47 were with the traditional method (Group II). The external fixator was removed when the measurement outcome (LS\u2009&lt;\u200910%) was consistent with the surgeon\u2019s diagnosis based on the clinical and radiological assessment (bone union achieved).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No significant difference was found in the fracture healing time (mean 25.3 weeks vs. 24.9 weeks,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&gt;\u20090.05), frame-wearing duration (mean 25.5 weeks vs. 25.8 weeks,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&gt;\u20090.05), or LS measurement frequency (mean 1.1 times vs. 1.2 times,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&gt;\u20090.05). The measurement system installation time in Group I was significantly shorter compared to Group II (mean 14.8\u00a0min vs. 81.3\u00a0min,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.001). The LS value of the first measurement in Group I was lower than that of Group II (mean 5.1% vs. 6.9%,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.011). In Group I, the refracture rate was 0, but in Group II it was 4.3% (2\/47,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&gt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The novel hexapod LS-measurement system and involved method demonstrated enhanced convenience and precision in measuring the LS of the external fixator in vivo. The LS measurement indicates the callus stiffness of fracture healing, and is applicable to evaluate the safety of removing the fixator. Consequently, it is highly recommended for widespread adoption in clinical practice.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-024-07440-y","type":"journal-article","created":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T07:02:09Z","timestamp":1715238129000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["In vivo axial load-share ratio measurement using a novel hexapod system for safe external fixator removal"],"prefix":"10.1186","volume":"25","author":[{"given":"Sida","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanshi","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dong","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Miao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Defu","family":"Yu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuefei","family":"Fu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,5,9]]},"reference":[{"key":"7440_CR1","first-page":"1301","volume":"59","author":"D Jeremi\u0107","year":"2023","unstructured":"Jeremi\u0107 D, Rajovic N, Gluscevic B, Krivokapic B, Rajkovic S, Bogosavljevic N, et al. Updated Meta-analysis of randomized controlled trials comparing external fixation to Intramedullary Nailing in the treatment of Open Tibial fractures. Med (B Aires). 2023;59:1301.","journal-title":"Med (B Aires)"},{"key":"7440_CR2","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1186\/s13018-023-03530-0","volume":"18","author":"S Liu","year":"2023","unstructured":"Liu S, Yu D, Li H, Opoku M, Li J, Zhang B, et al. Combination of external fixation using digital six-axis fixator and internal fixation to treat severe complex knee deformity. J Orthop Surg Res. 2023;18:65.","journal-title":"J Orthop Surg Res"},{"key":"7440_CR3","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1002\/jor.20033","volume":"24","author":"GT Aarnes","year":"2006","unstructured":"Aarnes GT, Steen H, Kristiansen LP, Fest\u00f8 E, Ludvigsen P. Optimum loading mode for axial stiffness testing in limb lengthening. J Orthop Res. 2006;24:348\u201354.","journal-title":"J Orthop Res"},{"key":"7440_CR4","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.bonr.2017.03.002","volume":"6","author":"MS Ghiasi","year":"2017","unstructured":"Ghiasi MS, Chen J, Vaziri A, Rodriguez EK, Nazarian A. Bone fracture healing in mechanobiological modeling: a review of principles and methods. Bone Rep. 2017;6:87\u2013100.","journal-title":"Bone Rep"},{"key":"7440_CR5","doi-asserted-by":"crossref","unstructured":"Fischgrund J, Paley D, Suter C. Variables affecting time to bone healing during limb lengthening. In: Clinical Orthopaedics and Related Research. 1994.","DOI":"10.1097\/00003086-199404000-00006"},{"key":"7440_CR6","doi-asserted-by":"publisher","first-page":"3015","DOI":"10.1007\/s00264-021-05116-z","volume":"45","author":"Y Liu","year":"2021","unstructured":"Liu Y, Cai F, Liu K, Zhang X, Li H, Fu X, et al. Bony callus stiffness indirectly evaluated by the axial load-share ratio in vivo as a guide to removing a monolateral external fixator safely. Int Orthop. 2021;45:3015\u201323.","journal-title":"Int Orthop"},{"key":"7440_CR7","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1302\/0301-620X.82B5.0820659","volume":"82","author":"AHRW Simpson","year":"2000","unstructured":"Simpson AHRW, Kenwright J. Fracture after distraction osteogenesis. J Bone Joint Surg. 2000;82:659\u201365.","journal-title":"J Bone Joint Surg"},{"key":"7440_CR8","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.jcot.2017.07.004","volume":"8","author":"S Galal","year":"2017","unstructured":"Galal S. Dynamic locked plating for fixation of distal femur fractures using near- cortical over-drilling: preliminary results of a prospective observational study. J Clin Orthop Trauma. 2017;8:215\u20139.","journal-title":"J Clin Orthop Trauma"},{"key":"7440_CR9","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.injury.2018.09.013","volume":"50","author":"R Wang","year":"2019","unstructured":"Wang R, Zhang H, Cui H, Fan Z, Xu K, Liu P, et al. Clinical effects and risk factors of far cortical locking system in the treatment of lower limb fractures. Injury. 2019;50:432\u20137.","journal-title":"Injury"},{"key":"7440_CR10","doi-asserted-by":"crossref","unstructured":"Wang A, Wei T, Stockton DJ, Flury A, Kim TG, Roffey DM, Lefaivre KA. Radiographic Union Assessment in surgically treated distal femur fractures. JBJS Rev. 2024;12.","DOI":"10.2106\/JBJS.RVW.23.00223"},{"key":"7440_CR11","doi-asserted-by":"publisher","first-page":"776","DOI":"10.1016\/S0268-0033(01)00079-1","volume":"16","author":"CI Moorcroft","year":"2001","unstructured":"Moorcroft CI, Ogrodnik PJ, Thomas PBM, Wade RH. Mechanical properties of callus in human tibial fractures: a preliminary investigation. Clin Biomech Elsevier Ltd. 2001;16:776\u201382.","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"7440_CR12","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1243\/09544119JEIM264","volume":"221","author":"PJ Ogrodnik","year":"2007","unstructured":"Ogrodnik PJ, Moorcroft CI, Thomas PB. Measuring multi-dimensional, time-dependent mechanical properties of a human tibial fracture using an automated system. Proc Inst Mech Eng H. 2007;221:641\u201352.","journal-title":"Proc Inst Mech Eng H"},{"key":"7440_CR13","doi-asserted-by":"publisher","first-page":"1343","DOI":"10.1002\/jor.20419","volume":"25","author":"DD Robertson","year":"2007","unstructured":"Robertson DD, Beck TJ, Chan BW, Scott WW, Sharma GB, Maloney WJ. Torsional strength estimates of femoral diaphyses with endosteal lytic lesions: dual-energy x\u2010ray absorptiometry study. J Orthop Res. 2007;25:1343\u201350.","journal-title":"J Orthop Res"},{"key":"7440_CR14","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1002\/jor.1100180610","volume":"18","author":"H Windhagen","year":"2000","unstructured":"Windhagen H, Kolbeck S, Bail H, Schmeling A, Raschke M. Quantitative assessment of in vivo bone regeneration consolidation in distraction osteogenesis. J Orthop Res. 2000;18:912\u20139.","journal-title":"J Orthop Res"},{"key":"7440_CR15","doi-asserted-by":"publisher","first-page":"2663","DOI":"10.1007\/s10439-015-1330-7","volume":"43","author":"J Mora-Mac\u00edas","year":"2015","unstructured":"Mora-Mac\u00edas J, Reina-Romo E, L\u00f3pez-Pliego M, Gir\u00e1ldez-S\u00e1nchez MA, Dom\u00ednguez J. In vivo mechanical characterization of the distraction callus during bone consolidation. Ann Biomed Eng. 2015;43:2663\u201374.","journal-title":"Ann Biomed Eng"},{"key":"7440_CR16","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.clinbiomech.2018.05.012","volume":"56","author":"C Parks","year":"2018","unstructured":"Parks C, McAndrew CM, Spraggs-Hughes A, Ricci WM, Silva MJ, Gardner MJ. In-vivo stiffness assessment of distal femur fracture locked plating constructs. Clin Biomech Elsevier Ltd. 2018;56:46\u201351.","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"7440_CR17","doi-asserted-by":"publisher","first-page":"653","DOI":"10.1007\/s00402-005-0049-6","volume":"125","author":"T Schmickal","year":"2005","unstructured":"Schmickal T, von Recum J, Wentzensen A. Stiffness measurement of the neocallus with the Fraktometer FM 100\u00ae. Arch Orthop Trauma Surg. 2005;125:653\u20139.","journal-title":"Arch Orthop Trauma Surg"},{"key":"7440_CR18","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1016\/j.orthres.2004.08.024","volume":"23","author":"GT Aarnes","year":"2005","unstructured":"Aarnes GT, Steen H, Ludvigsen P, Waanders NA, Huiskes R, Goldstein SA. In vivo assessment of regenerate axial stiffness in distraction osteogenesis. J Orthop Res. 2005;23:494\u20138.","journal-title":"J Orthop Res"},{"key":"7440_CR19","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.clinbiomech.2005.08.011","volume":"21","author":"V Vijayakumar","year":"2006","unstructured":"Vijayakumar V, Marks L, Bremmer-Smith A, Hardy J, Gardner T. Load transmission through a healing tibial fracture. Clin Biomech Elsevier Ltd. 2006;21:49\u201353.","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"7440_CR20","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1080\/17453674.2017.1295706","volume":"88","author":"J Horn","year":"2017","unstructured":"Horn J, Steen H, Huhnstock S, Hvid I, Gunderson RB. Limb lengthening and deformity correction of congenital and acquired deformities in children using the Taylor spatial frame. Acta Orthop. 2017;88:334\u201340.","journal-title":"Acta Orthop"},{"key":"7440_CR21","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.jor.2016.07.002","volume":"13","author":"A Khunda","year":"2016","unstructured":"Khunda A, Al-Maiyah M, Eardley WGP, Montgomery R. The management of tibial fracture non-union using the Taylor spatial frame. J Orthop. 2016;13:360\u20133.","journal-title":"J Orthop"},{"key":"7440_CR22","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1243\/PIME_PROC_1965_180_029_02","volume":"180","author":"D Stewart","year":"1965","unstructured":"Stewart D. A platform with six degrees of freedom. Proc Institution Mech Eng. 1965;180:371\u201386.","journal-title":"Proc Institution Mech Eng"},{"key":"7440_CR23","doi-asserted-by":"crossref","unstructured":"Lynch KM, Park F. Modern Robotics -Mechanics, Planning, and Control. 2017.","DOI":"10.1017\/9781316661239"},{"key":"7440_CR24","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1007\/s10665-005-9007-0","volume":"54","author":"H Mutlu","year":"2006","unstructured":"Mutlu H, Ak\u00e7ali \u0130D, G\u00fcl\u015fen M. A Mathematical Model for the Use of a Gough-Stewart platform mechanism as a Fixator. J Eng Math. 2006;54:119\u201343.","journal-title":"J Eng Math"},{"key":"7440_CR25","unstructured":"Craig JJ. Introduction to Robotics: Mechanics and Control, 3rd Edition. 2004."},{"key":"7440_CR26","doi-asserted-by":"publisher","first-page":"860","DOI":"10.5435\/JAAOS-D-22-00077","volume":"31","author":"MJ Moses","year":"2023","unstructured":"Moses MJ, Tejwani NC. The role of external fixation in the management of Upper Extremity fractures. J Am Acad Orthop Surg. 2023;31:860\u201370.","journal-title":"J Am Acad Orthop Surg"},{"key":"7440_CR27","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1016\/j.injury.2022.12.027","volume":"54","author":"A Watts","year":"2023","unstructured":"Watts A, Sadekar V, Moulder E, Souroullas P, Hadland Y, Barron E, et al. A comparative evaluation of the time to frame removal for tibia fractures treated with hexapod and Ilizarov circular frames. Injury. 2023;54:996\u20131003.","journal-title":"Injury"},{"key":"7440_CR28","doi-asserted-by":"crossref","unstructured":"Sumner DR, Galante JO. Determinants of stress shielding: design versus materials versus interface. Clin Orthop Relat Res. 1992;:202\u201312.","DOI":"10.1097\/00003086-199201000-00020"},{"key":"7440_CR29","doi-asserted-by":"crossref","unstructured":"Krettek C, Haas N, Tscherne H. The role of supplemental lag-screw fixation for open fractures of the tibial shaft treated with external fixation. J Bone Joint Surg - Ser A. 1991;73.","DOI":"10.2106\/00004623-199173060-00011"},{"key":"7440_CR30","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s00256-018-3051-0","volume":"48","author":"JS Fisher","year":"2019","unstructured":"Fisher JS, Kazam JJ, Fufa D, Bartolotta RJ. Radiologic evaluation of fracture healing. Skeletal Radiol. 2019;48:349\u201361.","journal-title":"Skeletal Radiol"},{"key":"7440_CR31","doi-asserted-by":"publisher","first-page":"1862","DOI":"10.2106\/JBJS.G.01580","volume":"90","author":"LA Corrales","year":"2008","unstructured":"Corrales LA, Morshed S, Bhandari M, Miclau T. Variability in the Assessment of Fracture-Healing in Orthopaedic Trauma studies. J Bone Joint Surgery-American Volume. 2008;90:1862\u20138.","journal-title":"J Bone Joint Surgery-American Volume"},{"key":"7440_CR32","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1097\/01202412-200607000-00007","volume":"15","author":"A Anand","year":"2006","unstructured":"Anand A, Feldman DS, Patel RJ, Lehman WB, van Bosse HJP, Badra MI, et al. Interobserver and intraobserver reliability of radiographic evidence of bone healing at osteotomy sites. J Pediatr Orthop B. 2006;15:271\u20132.","journal-title":"J Pediatr Orthop B"},{"key":"7440_CR33","doi-asserted-by":"publisher","first-page":"S10","DOI":"10.1016\/j.injury.2019.03.041","volume":"50","author":"EK Bliven","year":"2019","unstructured":"Bliven EK, Greinwald M, Hackl S, Augat P. External fixation of the lower extremities: biomechanical perspective and recent innovations. Injury. 2019;50:S10\u20137.","journal-title":"Injury"},{"key":"7440_CR34","doi-asserted-by":"publisher","first-page":"110188","DOI":"10.1016\/j.jbiomech.2020.110188","volume":"116","author":"M Ernst","year":"2021","unstructured":"Ernst M, Baumgartner H, D\u00f6bele S, H\u00f6ntzsch D, Pohlemann T, Windolf M. Clinical feasibility of fracture healing assessment through continuous monitoring of implant load. J Biomech. 2021;116:110188.","journal-title":"J Biomech"},{"key":"7440_CR35","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1097\/BOT.0b013e3181962e0e","volume":"23","author":"MT Archdeacon","year":"2009","unstructured":"Archdeacon MT, Arebi S, Le TT, Wirth R, Kebel R, Thakore M. Orthogonal pin construct versus parallel uniplanar pin constructs for pelvic external fixation: a biomechanical assessment of stiffness and strength. J Orthop Trauma. 2009;23:100\u20135.","journal-title":"J Orthop Trauma"},{"key":"7440_CR36","first-page":"1640","volume":"41","author":"C Cai","year":"2021","unstructured":"Cai C, Shi B, Ji G, Feng Y, Shu H. Biomechanical study on the fixation effect of circular external fixators for oblique fractures of long bones. Chin J Orthop. 2021;41:1640\u20136.","journal-title":"Chin J Orthop"}],"updated-by":[{"DOI":"10.1186\/s12891-024-07535-6","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2024,6,6]],"date-time":"2024-06-06T00:00:00Z","timestamp":1717632000000}}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07440-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-024-07440-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07440-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,7]],"date-time":"2024-06-07T02:03:42Z","timestamp":1717725822000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-024-07440-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,9]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["7440"],"URL":"https:\/\/doi.org\/10.1186\/s12891-024-07440-y","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,9]]},"assertion":[{"value":"12 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2024","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12891-024-07535-6","URL":"https:\/\/doi.org\/10.1186\/s12891-024-07535-6","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"<b>and constent to participate<\/b>.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"The studies involving humans were approved by the Ethics Committee of Tianjin Hospital (protocol code: 2023-MER-037). The studies were conducted in accordance with the local legislation and institutional requirements. All patients in this study had provided their written informed consent to participate in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Not applicable. No individual person\u2019s data in any form (including any individual details, images or videos) is contained in this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they do not have competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"353"}}