{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T10:52:49Z","timestamp":1785927169611,"version":"3.56.0"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T00:00:00Z","timestamp":1720137600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T00:00:00Z","timestamp":1720137600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>For the treatment of coronoid process fractures, medial, lateral, anterior, anteromedial, and posterior approaches have been increasingly reported; however, there is no general consensus on the method of fixation of coronal fractures. Here, we present a highly-extensile minimally invasive approach to treat coronoid process fractures using a mini-plate that can achieve anatomic reduction, stable fixation, and anterior capsular repair. Further, the study aimed to determine the complication rate of the anterior minimally invasive approach and to evaluate functional and clinical patient-reported outcomes during follow-up.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Thirty-one patients diagnosed with coronoid fractures accompanied with a \u201cterrible triad\u201d or posteromedial rotational instability between April 2012 and October 2018 were included in the analysis. Anatomical reduction and mini-plate fixation of coronoid fractures were performed using an anterior minimally invasive approach. Patient-reported outcomes were evaluated using the Mayo Elbow Performance Index (MEPI) score, range of motion (ROM), and the visual analog score (VAS). The time of fracture healing and complications were recorded.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean follow-up time was 26.7 months (range, 14\u201360 months). The average time to radiological union was 3.6\u2009\u00b1\u20091.3 months. During the follow-up period, the average elbow extension was 6.8\u2009\u00b1\u20092.9\u00b0 while the average flexion was 129.6\u2009\u00b1\u20094.6\u00b0. According to Morrey\u2019s criteria, 26 (81%) elbows achieved a normal desired ROM. At the last follow-up, the mean MEPI score was 98\u2009\u00b1\u20093.3 points. There were no instances of elbow instability, elbow joint stiffness, subluxation or dislocation, infection, blood vessel complications, or nerve palsy. Overall, 10 elbows (31%) experienced heterotopic ossification.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>An anterior minimally invasive approach allows satisfactory fixation of coronoid fractures while reducing incision complications due to over-dissection of soft tissue injuries. In addition, this incision does not compromise the soft tissue stability of the elbow joint and allows the patient a more rapid return to rehabilitation exercises.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-024-07637-1","type":"journal-article","created":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T08:02:29Z","timestamp":1720166549000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Highly extensile approach for comminuted ulna coronoid process fractures with mini-plate fixation: a case series of 31 patients"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5700-7754","authenticated-orcid":false,"given":"Shi-Cheng","family":"Zhou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8636-155X","authenticated-orcid":false,"given":"Sheng-Yu","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6298-5357","authenticated-orcid":false,"given":"Qing-Yu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4137-4485","authenticated-orcid":false,"given":"Guang-Kai","family":"Ren","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0992-554X","authenticated-orcid":false,"given":"Chuan-Gang","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2770-756X","authenticated-orcid":false,"given":"Yan-Bing","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7859-6631","authenticated-orcid":false,"given":"Dan-Kai","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,5]]},"reference":[{"issue":"Suppl 3","key":"7637_CR1","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1097\/bot.0000000000002385","volume":"36","author":"MT Kingery","year":"2022","unstructured":"Kingery MT, Lowe DT, Egol KA. Operative fixation of the Anteromedial Facet of the coronoid process. J Orthop Trauma. 2022;36(Suppl 3):S7. https:\/\/doi.org\/10.1097\/bot.0000000000002385.","journal-title":"J Orthop Trauma"},{"key":"7637_CR2","doi-asserted-by":"publisher","unstructured":"Thayer MK, Swenson AK, Hackett DJ, Hsu JE. Classifications in brief: Regan-Morrey classification of Coronoid fractures. Clin Orthop Relat Research\u00ae. 2018;476(7):1540\u20133. https:\/\/doi.org\/10.1007\/s11999.0000000000000072.","DOI":"10.1007\/s11999.0000000000000072"},{"issue":"6","key":"7637_CR3","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1016\/j.jemermed.2018.02.011","volume":"54","author":"M Gottlieb","year":"2018","unstructured":"Gottlieb M, Schiebout J. Elbow dislocations in the Emergency Department: a review of reduction techniques. J Emerg Med. 2018;54(6):849\u201354. https:\/\/doi.org\/10.1016\/j.jemermed.2018.02.011.","journal-title":"J Emerg Med"},{"issue":"12","key":"7637_CR4","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.2106\/00004623-200012000-00009","volume":"82","author":"RF Closkey","year":"2000","unstructured":"Closkey RF, Goode JR, Kirschenbaum D, Cody RP. The role of the coronoid process in Elbow Stability: a biomechanical analysis of Axial Loading*. JBJS. 2000;82(12):1749.","journal-title":"JBJS"},{"issue":"7","key":"7637_CR5","doi-asserted-by":"publisher","first-page":"608","DOI":"10.1007\/s00167-004-0594-5","volume":"13","author":"R Garofalo","year":"2005","unstructured":"Garofalo R, Bollmann C, Kombot C, Moretti B, Borens O, Mouhsine E. Minimal invasive surgery for coronoid fracture: technical note. Knee Surg Sports Traumatol Arthrosc. 2005;13(7):608\u201311. https:\/\/doi.org\/10.1007\/s00167-004-0594-5.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"7637_CR6","first-page":"113","volume":"52","author":"SW O\u2019Driscoll","year":"2003","unstructured":"O\u2019Driscoll SW, Jupiter JB, Cohen MS, Ring D, McKee MD. Difficult elbow fractures: pearls and pitfalls. Instr Course Lect. 2003;52:113\u201334.","journal-title":"Instr Course Lect"},{"key":"7637_CR7","doi-asserted-by":"publisher","unstructured":"Hausman MR, Klug RA, Qureshi S, Goldstein R, Parsons BO. Arthroscopically assisted coronoid fracture fixation: a preliminary report. Clin Orthop Relat Res. 2008;466(12):3147\u201352. https:\/\/doi.org\/10.1007\/s11999-008-0502-2.","DOI":"10.1007\/s11999-008-0502-2"},{"issue":"3","key":"7637_CR8","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1177\/1753193409352285","volume":"35","author":"LQ Kang","year":"2010","unstructured":"Kang LQ, Ding ZQ, Sha M, Hong JY, Chen W. A minimally invasive anterior approach to reduction and screw fixation of coronoid fractures. J Hand Surg Eur Vol. 2010;35(3):224\u20137. https:\/\/doi.org\/10.1177\/1753193409352285.","journal-title":"J Hand Surg Eur Vol"},{"issue":"6","key":"7637_CR9","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1016\/j.otsr.2017.05.020","volume":"103","author":"X Yang","year":"2017","unstructured":"Yang X, Chang W, Chen W, Liu S, Zhu Y, Zhang Y. A novel anterior approach for the fixation of ulnar coronoid process fractures. Orthop Traumatology: Surg Res. 2017;103(6):899\u2013904. https:\/\/doi.org\/10.1016\/j.otsr.2017.05.020.","journal-title":"Orthop Traumatology: Surg Res"},{"key":"7637_CR10","doi-asserted-by":"publisher","unstructured":"Arrigoni P, Cucchi D, Guerra E, Luceri F, Nicoletti S, Menon A, et al. No neurovascular damage after creation of an accessory anteromedial portal for arthroscopic reduction and fixation of coronoid fractures. Knee Surg Sports Traumatol Arthrosc. 2019;27(1):314\u20138. https:\/\/doi.org\/10.1007\/s00167-018-4926-2.","DOI":"10.1007\/s00167-018-4926-2"},{"key":"7637_CR11","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/978-3-319-46019-2_3","volume-title":"The unstable elbow: an evidence-based Approach to evaluation and management","author":"EV Cheung","year":"2017","unstructured":"Cheung EV, Sarkissian EJ. Surgical approaches to the elbow. In: Tashjian RZ, editor. The unstable elbow: an evidence-based Approach to evaluation and management. Cham: Springer International Publishing; 2017. pp. 27\u201338."},{"issue":"1","key":"7637_CR12","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.xrrt.2022.10.007","volume":"3","author":"MJ Peters","year":"2023","unstructured":"Peters MJ, Zarnett OJ, Glaris Z, Huang A, Pike J, Daneshvar P, et al. Anteromedial coronoid fractures: technical description of an extensile surgical approach and outcomes from a small series using this technique. JSES Reviews Rep Techniques. 2023;3(1):83\u20137. https:\/\/doi.org\/10.1016\/j.xrrt.2022.10.007.","journal-title":"JSES Reviews Rep Techniques"},{"key":"7637_CR13","doi-asserted-by":"publisher","unstructured":"Yan R, Wu Y, Xiang Z, Li S, Qi Y, Li H, et al. A Novel suture-preset spring plate system (SSPS) for comminuted coronoid process fracture in the elbow. Orthop Surg. 2022;14(10):2580\u201390. https:\/\/doi.org\/10.1111\/os.13460.","DOI":"10.1111\/os.13460"},{"key":"7637_CR14","doi-asserted-by":"publisher","unstructured":"Zhang B, Liu L, Liu J, Wang G, Han L, Tian X, et al. Surgical Treatment of Adams Type IV Anterolateral fracture of the Ulna Coronoid process. Orthop Surg. 2023;15(8):2033\u201341. https:\/\/doi.org\/10.1111\/os.13634.","DOI":"10.1111\/os.13634"},{"issue":"4","key":"7637_CR15","doi-asserted-by":"publisher","first-page":"030006052110083","DOI":"10.1177\/03000605211008323","volume":"49","author":"S Zhao","year":"2021","unstructured":"Zhao S, Zeng C, Yuan S, Li R. Reconstruction of coronoid process of the ulna: a literature review. J Int Med Res. 2021;49(4):03000605211008323. https:\/\/doi.org\/10.1177\/03000605211008323.","journal-title":"J Int Med Res"},{"issue":"15","key":"7637_CR16","doi-asserted-by":"publisher","first-page":"1232","DOI":"10.21037\/atm-21-2542","volume":"9","author":"Y-J Zha","year":"2021","unstructured":"Zha Y-J, Xiao D, Hua K-H, Sun W-T, Gong M-Q, Li T, et al. Lateral minimal approach to the terrible triad of the elbow: a treatment protocol in Beijing Jishuitan Hospital. Annals Translational Med. 2021;9(15):1232.","journal-title":"Annals Translational Med"},{"key":"7637_CR17","doi-asserted-by":"publisher","unstructured":"Kholinne E, Liu H, Singjie LC, Anastasia M, Kwak J-M, Jeon I-H. Surgical outcomes and complication rates of arthroscopic-assisted fixation versus open fixation for coronoid fractures: a systematic review and meta-analysis. Shoulder Elb. https:\/\/doi.org\/10.1177\/17585732241229636.","DOI":"10.1177\/17585732241229636"},{"key":"7637_CR18","doi-asserted-by":"publisher","unstructured":"Thayer MK, Swenson AK, Hackett DJ, Hsu JE. Classifications in brief: Regan-Morrey classification of Coronoid fractures. Clin Orthop Relat Res. 2018;476(7):1540\u20133. https:\/\/doi.org\/10.1007\/s11999.0000000000000072.","DOI":"10.1007\/s11999.0000000000000072"},{"key":"7637_CR19","doi-asserted-by":"crossref","unstructured":"Cage DJ, Abrams RA, Callahan JJ, Botte MJ. Soft tissue attachments of the ulnar coronoid process. An anatomic study with radiographic correlation. Clin Orthop Relat Res. 1995;320:154\u20138.","DOI":"10.1097\/00003086-199511000-00026"},{"issue":"2","key":"7637_CR20","doi-asserted-by":"publisher","first-page":"387","DOI":"10.5603\/FM.a2019.0093","volume":"79","author":"XH Yang","year":"2020","unstructured":"Yang XH, Wei C, Li GP, Wang JJ, Zhao HT, Shi LT, et al. Anatomical study of the anterior neurovascular interval approach to the elbow: observation of the neurovascular interval and relevant branches. Folia Morphol (Warsz). 2020;79(2):387\u201394. https:\/\/doi.org\/10.5603\/FM.a2019.0093.","journal-title":"Folia Morphol (Warsz)"},{"issue":"1","key":"7637_CR21","doi-asserted-by":"publisher","first-page":"230949901882522","DOI":"10.1177\/2309499018825223","volume":"27","author":"JJ Shen","year":"2019","unstructured":"Shen JJ, Qiu QM, Gao YB, Tong SL, Huang JF. Direct anterior approach for mini plate fixation of Regan-Morrey type II comminuted ulnar coronoid process fracture. J Orthop Surg (Hong Kong). 2019;27(1):2309499018825223. https:\/\/doi.org\/10.1177\/2309499018825223.","journal-title":"J Orthop Surg (Hong Kong)"},{"issue":"2","key":"7637_CR22","first-page":"158","volume":"26","author":"HB Huang","year":"2013","unstructured":"Huang HB, Ji XR, Fan SW, Bao F. [Internal fixation for the treatment of anteromedial facet fracture of the coronoid process of ulna]. Zhongguo Gu Shang. 2013;26(2):158\u201361.","journal-title":"Zhongguo Gu Shang"},{"issue":"4","key":"7637_CR23","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1007\/s00590-012-1007-y","volume":"23","author":"SH Han","year":"2013","unstructured":"Han SH, Yoon HK, Rhee SY, Lee JK. Anterior approach for fixation of isolated type III coronoid process fracture. Eur J Orthop Surg Traumatol. 2013;23(4):395\u2013405. https:\/\/doi.org\/10.1007\/s00590-012-1007-y.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"7637_CR24","doi-asserted-by":"publisher","unstructured":"Ring D, Doornberg JN. Fracture of the anteromedial facet of the coronoid process. Surgical technique. J Bone Joint Surg Am. 2007;89. https:\/\/doi.org\/10.2106\/jbjs.g.00059. Suppl 2 Pt.2:267\u2009\u2013\u200983.","DOI":"10.2106\/jbjs.g.00059"},{"issue":"10","key":"7637_CR25","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1016\/j.jhsa.2006.08.020","volume":"31","author":"D Ring","year":"2006","unstructured":"Ring D. Fractures of the coronoid process of the ulna. J Hand Surg Am. 2006;31(10):1679. https:\/\/doi.org\/10.1016\/j.jhsa.2006.08.020.","journal-title":"J Hand Surg Am"},{"key":"7637_CR26","doi-asserted-by":"publisher","unstructured":"Yoon RS, Tyagi V, Cantlon MB, Riesgo AM, Liporace FA. Complex coronoid and proximal ulna fractures are we getting better at fixing these? Injury. 2016;47(10):2053\u20139. https:\/\/doi.org\/10.1016\/j.injury.2016.07.060.","DOI":"10.1016\/j.injury.2016.07.060"},{"key":"7637_CR27","doi-asserted-by":"publisher","unstructured":"Pugh DM, Wild LM, Schemitsch EH, King GJ, McKee MD. Standard surgical protocol to treat elbow dislocations with radial head and coronoid fractures. J Bone Joint Surg Am. 2004;86(6):1122\u201330. https:\/\/doi.org\/10.2106\/00004623-200406000-00002.","DOI":"10.2106\/00004623-200406000-00002"},{"issue":"1","key":"7637_CR28","doi-asserted-by":"publisher","first-page":"22","DOI":"10.2106\/jbjs.d.02933","volume":"87","author":"MD McKee","year":"2005","unstructured":"McKee MD, Pugh DM, Wild LM, Schemitsch EH, King GJ. Standard surgical protocol to treat elbow dislocations with radial head and coronoid fractures. Surgical technique. J Bone Joint Surg Am. 2005;87(1):22\u201332. https:\/\/doi.org\/10.2106\/jbjs.d.02933.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"7637_CR29","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.jse.2004.04.012","volume":"14","author":"J Sanchez-Sotelo","year":"2005","unstructured":"Sanchez-Sotelo J, O\u2019Driscoll SW, Morrey BF. Medial oblique compression fracture of the coronoid process of the ulna. J Shoulder Elb Surg. 2005;14(1):60\u20134. https:\/\/doi.org\/10.1016\/j.jse.2004.04.012.","journal-title":"J Shoulder Elb Surg"},{"issue":"11","key":"7637_CR30","doi-asserted-by":"publisher","first-page":"e451","DOI":"10.1097\/bot.0000000000001266","volume":"32","author":"J Morellato","year":"2018","unstructured":"Morellato J, Louati H, Desloges W, Papp S, Pollock JW. Fixation of Anteromedial Coronoid Facet fractures: a biomechanical evaluation of plated Versus Screw constructs. J Orthop Trauma. 2018;32(11):e451\u20136. https:\/\/doi.org\/10.1097\/bot.0000000000001266.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"7637_CR31","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1186\/s12891-018-2117-4","volume":"19","author":"HW Chen","year":"2018","unstructured":"Chen HW, He HH, Gao BL. Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures. BMC Musculoskelet Disord. 2018;19(1):194. https:\/\/doi.org\/10.1186\/s12891-018-2117-4.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"7637_CR32","doi-asserted-by":"publisher","first-page":"e10172","DOI":"10.1002\/jbm4.10172","volume":"3","author":"C Meyers","year":"2019","unstructured":"Meyers C, Lisiecki J, Miller S, Levin A, Fayad L, Ding C, et al. Heterotopic ossification: a Comprehensive Review. JBMR Plus. 2019;3(4):e10172. https:\/\/doi.org\/10.1002\/jbm4.10172.","journal-title":"JBMR Plus"},{"key":"7637_CR33","doi-asserted-by":"publisher","unstructured":"Park MJ, Chang MJ, Lee YB, Kang HJ. Surgical release for posttraumatic loss of elbow flexion. J Bone Joint Surg Am. 2010;92(16):2692\u20139. https:\/\/doi.org\/10.2106\/jbjs.i.01367.","DOI":"10.2106\/jbjs.i.01367"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07637-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-024-07637-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07637-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T08:09:02Z","timestamp":1720166942000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-024-07637-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,5]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["7637"],"URL":"https:\/\/doi.org\/10.1186\/s12891-024-07637-1","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,5]]},"assertion":[{"value":"5 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by Jilin University The Second Hospital Institutional Review Board. Written informed consent was obtained from all patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"522"}}