{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T03:11:31Z","timestamp":1768705891607,"version":"3.49.0"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T00:00:00Z","timestamp":1722297600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T00:00:00Z","timestamp":1722297600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-024-07735-0","type":"journal-article","created":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T09:05:31Z","timestamp":1722330331000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Finite element analysis of precise puncture vertebral augmentation in the treatment of different types of osteoporotic vertebral compression fractures"],"prefix":"10.1186","volume":"25","author":[{"given":"Hongyu","family":"Pan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongtao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tianzhu","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changming","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sen","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,7,30]]},"reference":[{"key":"7735_CR1","doi-asserted-by":"publisher","unstructured":"Lin X, Xiong D, Peng YQ, Sheng ZF, Wu XY, Wu XP, Wu F, Yuan LQ, Liao EY. Epidemiology and management of osteoporosis in the People&rsquo;s Republic of China: current perspectives. Clin Interv Aging. 2015;0(0):1017\u20131017. https:\/\/doi.org\/10.2147\/cia.s54613","DOI":"10.2147\/cia.s54613"},{"issue":"S2","key":"7735_CR2","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1007\/s00586-018-5605-1","volume":"27","author":"K Martikos","year":"2018","unstructured":"Martikos K, Greggi T, Faldini C, Vommaro F, Scarale A. Osteoporotic thoracolumbar compression fractures: long-term retrospective comparison between vertebroplasty and conservative treatment. Eur Spine J. 2018;27(S2):244\u20137. https:\/\/doi.org\/10.1007\/s00586-018-5605-1.","journal-title":"Eur Spine J"},{"issue":"1","key":"7735_CR3","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1177\/1553350619869535","volume":"27","author":"L Zhang","year":"2019","unstructured":"Zhang L, Zhai P. A comparison of percutaneous vertebroplasty versus conservative treatment in terms of treatment effect for osteoporotic vertebral compression fractures: a meta-analysis. Surg Innov. 2019;27(1):19\u201325. https:\/\/doi.org\/10.1177\/1553350619869535.","journal-title":"Surg Innov"},{"issue":"6","key":"7735_CR4","doi-asserted-by":"publisher","first-page":"564","DOI":"10.5312\/wjo.v13.i6.564","volume":"13","author":"D Patel","year":"2022","unstructured":"Patel D, Liu J, Ebraheim NA. Managements of osteoporotic vertebral compression fractures: a narrative review. World J Orthop. 2022;13(6):564\u201373. https:\/\/doi.org\/10.5312\/wjo.v13.i6.564.","journal-title":"World J Orthop"},{"key":"7735_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2022\/7770214","volume":"2022","author":"H Liu","year":"2022","unstructured":"Liu H, Deng L, Zhang J, Zhou Q, Zhou Q, Fan C-Y, Chen K, Yang H. Effect of different anesthesia and puncture methods of percutaneous kyphoplasty on more than 90-year-old osteoporotic vertebral fracture: advantages of the ERAS concept. Int J Clin Pract. 2022;2022:1\u20138. https:\/\/doi.org\/10.1155\/2022\/7770214.","journal-title":"Int J Clin Pract"},{"issue":"4","key":"7735_CR6","doi-asserted-by":"publisher","first-page":"S49","DOI":"10.1097\/bot.0000000000000949","volume":"31","author":"S Rajasekaran","year":"2017","unstructured":"Rajasekaran S, Kanna RM, Schnake KJ, Vaccaro AR, Schroeder GD, Sadiqi S, Oner C. Osteoporotic thoracolumbar fractures\u2014how are they different?\u2014Classification and treatment algorithm. J Orthop Trauma. 2017;31(4):S49\u201356. https:\/\/doi.org\/10.1097\/bot.0000000000000949.","journal-title":"J Orthop Trauma"},{"key":"7735_CR7","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.wneu.2017.01.057","volume":"100","author":"AF Ozer","year":"2017","unstructured":"Ozer AF, Suzer T, Can H, Falsafi M, Aydin M, Sasani M, Oktenoglu T. Anatomic assessment of variations in Kambin\u2019s triangle: a surgical and cadaver study. World Neurosurg. 2017;100:498\u2013503. https:\/\/doi.org\/10.1016\/j.wneu.2017.01.057.","journal-title":"World Neurosurg"},{"key":"7735_CR8","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.jocn.2021.06.020","volume":"90","author":"M Machino","year":"2021","unstructured":"Machino M, Nakashima H, Ito K, Katayama Y, Matsumoto T, Tsushima M, Ando K, Kobayashi K. Age-related degenerative changes and sex-specific differences in osseous anatomy and intervertebral disc height of the thoracolumbar spine. J Clin Neurosci. 2021;90:317\u201324. https:\/\/doi.org\/10.1016\/j.jocn.2021.06.020.","journal-title":"J Clin Neurosci"},{"issue":"22.2","key":"7735_CR9","doi-asserted-by":"publisher","first-page":"E91","DOI":"10.36076\/ppj\/2019.22.e91","volume":"2","author":"H Wang","year":"2019","unstructured":"Wang H, Hu P, Wu D, Zhang N, Jun W, Xiang L. Age, gender, level and side differences in the anatomical distinctions of unilateral percutaneous kyphoplasty through the transverse processpedicle approach. Pain Physician. 2019;2(22.2):E91\u20136. https:\/\/doi.org\/10.36076\/ppj\/2019.22.e91.","journal-title":"Pain Physician"},{"issue":"1","key":"7735_CR10","doi-asserted-by":"publisher","first-page":"94","DOI":"10.3171\/2014.11.spine14579","volume":"23","author":"J-T Liu","year":"2015","unstructured":"Liu J-T, Li C-S, Chang C-S, Liao W-J. Long-term follow-up study of osteoporotic vertebral compression fracture treated using balloon kyphoplasty and vertebroplasty. J Neurosurg. 2015;23(1):94\u20138. https:\/\/doi.org\/10.3171\/2014.11.spine14579.","journal-title":"J Neurosurg"},{"key":"7735_CR11","doi-asserted-by":"publisher","unstructured":"Pan Z, Zhou Q, Yang M, Deng L, Xiayu H, Lv N, Yang S, Yang H. Effects of distribution of bone cement on clinical efficacy and secondary fracture after percutaneous kyphoplasty for osteoporotic vertebral compression fractures. Front Surg. 2023;9. https:\/\/doi.org\/10.3389\/fsurg.2022.1054995.","DOI":"10.3389\/fsurg.2022.1054995"},{"key":"7735_CR12","doi-asserted-by":"publisher","unstructured":"Schupfner R, Koniarikova K, Pfeifer C, Grechenig P, Bakota B, Staresinic M, Kerner MA, M\u00fcller M. An anatomical study of transpedicular vs. extrapedicular approach for kyphoplasty and vertebroplasty in the thoracic spine. Injury. 2021;52(0):S63-S69. https:\/\/doi.org\/10.1016\/j.injury.2020.11.017.","DOI":"10.1016\/j.injury.2020.11.017"},{"key":"7735_CR13","doi-asserted-by":"publisher","unstructured":"Gao T, Chen ZY, Li T, Lin X, Hu HG, Yuan DC, Zeng J, Wu C. Correlation analysis of the puncture-side bone cement\/vertebral body volume ratio and bone cement leakage in the paravertebral vein in vertebroplasty. BMC Musculoskelet Disord. 2022;23(1):0\u20130. https:\/\/doi.org\/10.1186\/s12891-022-05135-w.","DOI":"10.1186\/s12891-022-05135-w"},{"key":"7735_CR14","doi-asserted-by":"publisher","unstructured":"Tao W, Hu Q, Nicolas YS, Nuo X, Daoyu H, Zhen J, Jinpeng S, Jun L. Is unilateral transverse process-pedicle percutaneous kyphoplasty a better choice for osteoporotic thoracolumbar fractures in the old patients?. BMC Surg. 2021;21(1):0\u20130. https:\/\/doi.org\/10.1186\/s12893-021-01246-8.","DOI":"10.1186\/s12893-021-01246-8"},{"key":"7735_CR15","doi-asserted-by":"publisher","first-page":"6493712","DOI":"10.1155\/2021\/6493712","volume":"2021","author":"Y Zhuo","year":"2021","unstructured":"Zhuo Y, Liu L, Wang H, Li P, Zhou Q, Liu Y. A modified transverse process-pedicle approach applied to unilateral extrapedicular percutaneous vertebroplasty. Pain Res Manage. 2021;2021:6493712. https:\/\/doi.org\/10.1155\/2021\/6493712.","journal-title":"Pain Res Manage"},{"key":"7735_CR16","doi-asserted-by":"publisher","unstructured":"Huang J, Yang J, Chen L, Xu Y, Wang S. A novel puncture approach via point \u201cO\u201d for percutaneous kyphoplasty in patients with L4 or L5 osteoporotic vertebral compression fracture. Sci Rep. 2022;12(1):0\u20130. https:\/\/doi.org\/10.1038\/s41598-022-23732-6.","DOI":"10.1038\/s41598-022-23732-6"},{"issue":"3","key":"7735_CR17","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/bf01623271","volume":"3","author":"L Joseph Melton","year":"1993","unstructured":"Joseph Melton L, Lane AW, Cooper C, Richard Eastell W, O\u2019Fallon M, Lawrence Riggs B. Prevalence and incidence of vertebral deformities. Osteoporos Int. 1993;3(3):113\u20139. https:\/\/doi.org\/10.1007\/bf01623271.","journal-title":"Osteoporos Int"},{"issue":"1","key":"7735_CR18","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1186\/s13018-022-03447-0","volume":"17","author":"W Guo","year":"2022","unstructured":"Guo W, Jiang Y, Zhu Y, Huang J. Effect of ACDF combined with different degrees of partial resection of uncovertebral joints on cervical stability and degeneration: a three-dimensional finite element analysis. J Orthop Surg Res. 2022;17(1):551. https:\/\/doi.org\/10.1186\/s13018-022-03447-0.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"7735_CR19","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s40001-022-00769-x","volume":"27","author":"J Yan","year":"2022","unstructured":"Yan J, Liao Z, Yu Y. Finite element analysis of dynamic changes in spinal mechanics of osteoporotic lumbar fracture. Eur J Med Res. 2022;27(1):142. https:\/\/doi.org\/10.1186\/s40001-022-00769-x.","journal-title":"Eur J Med Res"},{"issue":"1","key":"7735_CR20","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1080\/10255842.2022.2044803","volume":"26","author":"Q Zhang","year":"2023","unstructured":"Zhang Q, Zhang Y, Chon TE, Baker JS, Gu Y. Analysis of stress and stabilization in adolescent with osteoporotic idiopathic scoliosis: finite element method. Comput Methods Biomech Biomed Engin. 2023;26(1):12\u201324. https:\/\/doi.org\/10.1080\/10255842.2022.2044803.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"1","key":"7735_CR21","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13018-018-0733-1","volume":"13","author":"WT Zhao","year":"2018","unstructured":"Zhao WT, Qin DP, Zhang XG, Wang ZP, Tong Z. Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis. J Orthop Surg Res. 2018;13(1):32. https:\/\/doi.org\/10.1186\/s13018-018-0733-1.","journal-title":"J Orthop Surg Res"},{"issue":"2","key":"7735_CR22","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1080\/1025584031000095746","volume":"6","author":"G Baroud","year":"2003","unstructured":"Baroud G, Nemes J, Ferguson SJ, Steffen T. Material changes in osteoporotic human cancellous bone following infiltration with acrylic bone cement for a vertebral cement augmentation. Comput Methods Biomec Biomed Eng. 2003;6(2):133\u20139. https:\/\/doi.org\/10.1080\/1025584031000095746.","journal-title":"Comput Methods Biomec Biomed Eng"},{"issue":"12","key":"7735_CR23","doi-asserted-by":"publisher","first-page":"2118","DOI":"10.1007\/s00586-007-0473-0","volume":"16","author":"A B\u00f6ger","year":"2007","unstructured":"B\u00f6ger A, Heini PF, Windolf M, Schneider E. Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement. Eur Spine J. 2007;16(12):2118\u201325. https:\/\/doi.org\/10.1007\/s00586-007-0473-0.","journal-title":"Eur Spine J"},{"issue":"11","key":"7735_CR24","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.1007\/s11517-018-1844-x","volume":"56","author":"Yi Peng","year":"2018","unstructured":"Peng Yi, Xianping Du, Huang L, Li J, Zhan R, Wang W, Biaoxiang Xu, Song Wu, Peng C, Chen S. Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling. Med Biol Eng Compu. 2018;56(11):2137\u201350. https:\/\/doi.org\/10.1007\/s11517-018-1844-x.","journal-title":"Med Biol Eng Compu"},{"key":"7735_CR25","doi-asserted-by":"publisher","unstructured":"Day GA, Jones AC, Wilcox RK. Optimizing computational methods of modeling vertebroplasty in experimentally augmented human lumbar vertebrae. JOR spine. 2020;3(1). https:\/\/doi.org\/10.1002\/jsp2.1077.","DOI":"10.1002\/jsp2.1077"},{"issue":"6","key":"7735_CR26","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1097\/01.BRS.0000049923.27694.47","volume":"28","author":"MA Liebschner","year":"2003","unstructured":"Liebschner MA, Kopperdahl DL, Rosenberg WS, Keaveny TM. Finite element modeling of the human thoracolumbar spine. Spine. 2003;28(6):559\u201365. https:\/\/doi.org\/10.1097\/01.BRS.0000049923.27694.47.","journal-title":"Spine"},{"issue":"1","key":"7735_CR27","doi-asserted-by":"publisher","first-page":"e35359","DOI":"10.1002\/jbm.b.35359","volume":"112","author":"S Mondal","year":"2024","unstructured":"Mondal S, MacManus DB, Banche-Niclot F, Vitale-Brovarone C, Fiorilli S, McCarthy HO, Dunne N. Finite element analysis of vertebroplasty in the osteoporotic T11\u2013L1 vertebral body: Effects of bone cement formulation. J Biomed Mater Res B Appl Biomater. 2024;112(1):e35359. https:\/\/doi.org\/10.1002\/jbm.b.35359.","journal-title":"J Biomed Mater Res B Appl Biomater"},{"issue":"9","key":"7735_CR28","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1016\/j.jbiomech.2009.03.036","volume":"42","author":"M El-Rich","year":"2009","unstructured":"El-Rich M, Arnoux P-J, Wagnac \u00c9, Brunet C, Aubin C-\u00c9. Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions. J Biomech. 2009;42(9):1252\u201362. https:\/\/doi.org\/10.1016\/j.jbiomech.2009.03.036.","journal-title":"J Biomech"},{"issue":"1","key":"7735_CR29","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1186\/s13018-021-02225-8","volume":"16","author":"XH Zuo","year":"2021","unstructured":"Zuo XH, Chen YB, Xie P, Zhang WD, Xue XY, Zhang QX, Shan B, Zhang XB, Bao HG, Si YN. Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures. J Orthop Surg Res. 2021;16(1):138. https:\/\/doi.org\/10.1186\/s13018-021-02225-8.","journal-title":"J Orthop Surg Res"},{"issue":"11","key":"7735_CR30","doi-asserted-by":"publisher","first-page":"1861","DOI":"10.1016\/j.spinee.2020.06.013","volume":"20","author":"MB Ogurkowska","year":"2020","unstructured":"Ogurkowska MB, B\u0142aszczyk A. Distribution of Young\u2019s modulus at various sampling points in a human lumbar spine vertebral body. Spine J. 2020;20(11):1861\u201375. https:\/\/doi.org\/10.1016\/j.spinee.2020.06.013.","journal-title":"Spine J"},{"issue":"6","key":"7735_CR31","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/s0021-9290(03)00015-0","volume":"36","author":"K Daggfeldt","year":"2003","unstructured":"Daggfeldt K, Thorstensson A. The mechanics of back-extensor torque production about the lumbar spine. J Biomech. 2003;36(6):815\u201325. https:\/\/doi.org\/10.1016\/s0021-9290(03)00015-0.","journal-title":"J Biomech"},{"issue":"6","key":"7735_CR32","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1016\/j.jbiomech.2006.05.030","volume":"40","author":"M de Zee","year":"2007","unstructured":"de Zee M, Hansen L, Wong C, et al. A generic detailed rigid-body lumbar spine model. J Biomech. 2007;40(6):1219\u201327. https:\/\/doi.org\/10.1016\/j.jbiomech.2006.05.030.","journal-title":"J Biomech"},{"issue":"3","key":"7735_CR33","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1007\/s10237-008-0129-y","volume":"8","author":"W Ehlers","year":"2009","unstructured":"Ehlers W, Karajan N, Markert B. An extended biphasic model for charged hydrated tissues with application to the intervertebral disc. Biomech Model Mechanobiol. 2009;8(3):233\u201351. https:\/\/doi.org\/10.1007\/s10237-008-0129-y.","journal-title":"Biomech Model Mechanobiol"},{"issue":"1","key":"7735_CR34","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jss.2014.12.053","volume":"195","author":"De Liang","year":"2015","unstructured":"Liang De, Ye L-Q, Jiang X, Yang P, Zhou G, Yao Z, Zhang S-C, Yang Z. Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis. J Surg Res. 2015;195(1):246\u201356. https:\/\/doi.org\/10.1016\/j.jss.2014.12.053.","journal-title":"J Surg Res"},{"key":"7735_CR35","doi-asserted-by":"publisher","unstructured":"Li Q, Yun C, Li S. Transpedicular bone grafting and pedicle screw fixation in injured vertebrae using a paraspinal approach for thoracolumbar fractures: a retrospective study. J Orthop Surg Res. 2016;11(1):0\u20130. https:\/\/doi.org\/10.1186\/s13018-016-0452-4.","DOI":"10.1186\/s13018-016-0452-4"},{"key":"7735_CR36","doi-asserted-by":"publisher","unstructured":"Z Wang, R Sun, SD Zhang, XT Wu. Comparison of thoracolumbar versus non-thoracolumbar osteoporotic vertebral compression fractures in risk factors, vertebral compression degree and pre-hospital back pain. J Orthop Surg Res. 2023;18(1):0-0. https:\/\/doi.org\/10.1186\/s13018-023-04140-6.","DOI":"10.1186\/s13018-023-04140-6"},{"key":"7735_CR37","doi-asserted-by":"publisher","unstructured":"Study of unilateral extrapedicular and bilateral pedicle approach percutaneous kyphoplasty for osteoporotic vertebral compression fracture. JCPSP. J Coll Physicians Surg Pak.  2022;32(07):924\u2013927. https:\/\/doi.org\/10.29271\/jcpsp.2022.07.924.","DOI":"10.29271\/jcpsp.2022.07.924"},{"issue":"9","key":"7735_CR38","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1097\/ajp.0b013e318154b6c3","volume":"23","author":"WS Chang","year":"2007","unstructured":"Chang WS, Lee S-H, Choi WG, Choi G, Jo B-J. Unipedicular vertebroplasty for osteoporotic compression fracture using an individualized needle insertion angle. Clin J Pain. 2007;23(9):767\u201373. https:\/\/doi.org\/10.1097\/ajp.0b013e318154b6c3.","journal-title":"Clin J Pain"},{"key":"7735_CR39","doi-asserted-by":"publisher","DOI":"10.3892\/etm.2019.7980","author":"Yu Xiaoming Xiong","year":"2019","unstructured":"Xiaoming Xiong Yu, Sun S-M, Yang M, Zhou J, Wan D, Deng X, Shi H. Efficacy of unilateral transverse process-pedicle and bilateral puncture techniques in percutaneous kyphoplasty for Kummell disease. Exp Ther Med. 2019. https:\/\/doi.org\/10.3892\/etm.2019.7980.","journal-title":"Exp Ther Med"},{"issue":"9","key":"7735_CR40","doi-asserted-by":"publisher","first-page":"2131","DOI":"10.1007\/s00264-018-3838-6","volume":"42","author":"Y Li","year":"2018","unstructured":"Li Y, Guo D-Q, Zhang S-C, Liang De, Yuan K, Mo G-y, Li D-X, Guo H, Tang Y-C, Luo P. Risk factor analysis for re-collapse of cemented vertebrae after percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP). Int Orthop. 2018;42(9):2131\u20139. https:\/\/doi.org\/10.1007\/s00264-018-3838-6.","journal-title":"Int Orthop"},{"issue":"24","key":"7735_CR41","doi-asserted-by":"publisher","first-page":"7530","DOI":"10.3390\/jcm11247530","volume":"11","author":"J Qi","year":"2022","unstructured":"Qi J, Yuanyu Hu, Yang Z, Dong Y, Zhang X, Hou G, Lv Y, Guo Y, Zhou F, Liu B, Tian Y. Incidence, risk factors, and outcomes of symptomatic bone cement displacement following percutaneous kyphoplasty for osteoporotic vertebral compression fracture: a single center study. J Clin Med. 2022;11(24):7530\u20137530. https:\/\/doi.org\/10.3390\/jcm11247530.","journal-title":"J Clin Med"},{"issue":"12","key":"7735_CR42","doi-asserted-by":"publisher","first-page":"e33309","DOI":"10.1097\/md.0000000000033309","volume":"102","author":"Q Song","year":"2023","unstructured":"Song Q, Zhao Y, Liu D, Liu Z, Zhang Y, Shang D, Geng Z, Shi Z, Fan L. Effect of different bone cement distributions in percutaneous kyphoplasty on clinical outcomes for osteoporotic vertebral compression fractures: a retrospective study. Medicine. 2023;102(12):e33309\u2013e33309. https:\/\/doi.org\/10.1097\/md.0000000000033309.","journal-title":"Medicine"},{"issue":"6","key":"7735_CR43","doi-asserted-by":"publisher","first-page":"E1101","DOI":"10.36076\/ppj.2015\/18\/E1101","volume":"18","author":"AR Cho","year":"2015","unstructured":"Cho AR, Cho SB, Jae-Ho L, Kim KH. Effect of augmentation material stiffness on adjacent vertebrae after osteoporotic vertebroplasty using finite element analysis with different loading methods. Pain physician. 2015;18(6):E1101-10.","journal-title":"Pain physician"},{"issue":"11","key":"7735_CR44","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.1007\/s00586-010-1479-6","volume":"19","author":"Y-Y Kim","year":"2010","unstructured":"Kim Y-Y, Rhyu K-W. Recompression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture. Eur Spine J. 2010;19(11):1907\u201312. https:\/\/doi.org\/10.1007\/s00586-010-1479-6.","journal-title":"Eur Spine J"},{"key":"7735_CR45","doi-asserted-by":"publisher","unstructured":"Zuo XH, Chen YB, Xie P, Zhang WD, Xue XY, Zhang QX, Shan B, Zhang XB, Bao HG, Si YN. Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures. J Orthop Surg Res. 2021;16(1):0\u20130. https:\/\/doi.org\/10.1186\/s13018-021-02225-8.","DOI":"10.1186\/s13018-021-02225-8"},{"issue":"24","key":"7735_CR46","doi-asserted-by":"publisher","first-page":"2178","DOI":"10.2106\/jbjs.22.00469","volume":"104","author":"ES Mills","year":"2022","unstructured":"Mills ES, Hah RJ, Fresquez Z, Mertz K, Buser Z, Alluri RK, Anderson PA. Secondary fracture rate after vertebral osteoporotic compression fracture is decreased by anti-osteoporotic medication but not increased by cement augmentation. J Bone Joint Surg Am. 2022;104(24):2178\u201385. https:\/\/doi.org\/10.2106\/jbjs.22.00469.","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"7735_CR47","doi-asserted-by":"publisher","first-page":"1414","DOI":"10.1016\/j.jbiomech.2012.02.021","volume":"45","author":"F Niemeyer","year":"2012","unstructured":"Niemeyer F, Wilke HJ, Schmidt H. Geometry strongly influences the response of numerical models of the lumbar spine\u2013a probabilistic finite element analysis. J Biomech. 2012;45(8):1414\u201323. https:\/\/doi.org\/10.1016\/j.jbiomech.2012.02.021.","journal-title":"J Biomech"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07735-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-024-07735-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07735-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T09:06:41Z","timestamp":1722330401000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-024-07735-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,30]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["7735"],"URL":"https:\/\/doi.org\/10.1186\/s12891-024-07735-0","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,30]]},"assertion":[{"value":"25 May 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study obtained an exemption from ethical approval from the Ethics Committee of the Affiliated Hospitalof Traditional ChineseMedicine of Southwest Medical University due|to the use of anonymized data: in accordance with the Declaration of Helsinki. The authors obtained informed consent from the patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent was obtained from all patients.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"599"}}