{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:32:45Z","timestamp":1787020365200,"version":"build-2736575974"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,15]],"date-time":"2024-11-15T00:00:00Z","timestamp":1731628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,11,15]],"date-time":"2024-11-15T00:00:00Z","timestamp":1731628800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-024-07995-w","type":"journal-article","created":{"date-parts":[[2024,11,15]],"date-time":"2024-11-15T05:26:48Z","timestamp":1731648408000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A novel method to judge the safe position of C2 lamina screw with double holes"],"prefix":"10.1186","volume":"25","author":[{"given":"Zhen-Shan","family":"Yuan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lian-Song","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,15]]},"reference":[{"issue":"4","key":"7995_CR1","doi-asserted-by":"publisher","first-page":"E193","DOI":"10.1097\/BSD.0000000000000813","volume":"32","author":"JW Hur","year":"2019","unstructured":"Hur JW, Kim JS, Ryu KS, et al. Accuracy and safety in screw placement in the high cervical spine: retrospective analysis of o-arm-based navigation-assisted c1 lateral mass and c2 pedicle screws. Clin Spine Surg. 2019;32(4):E193\u20139. https:\/\/doi.org\/10.1097\/BSD.0000000000000813.","journal-title":"Clin Spine Surg"},{"issue":"7","key":"7995_CR2","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/j.spinee.2017.11.010","volume":"18","author":"P Punyarat","year":"2018","unstructured":"Punyarat P, Buchowski JM, Klawson BT, et al. Freehand technique for C2 pedicle and pars screw placement: is it safe? Spine J. 2018;18(7):1197\u2013203. https:\/\/doi.org\/10.1016\/j.spinee.2017.11.010.","journal-title":"Spine J"},{"issue":"7","key":"7995_CR3","doi-asserted-by":"publisher","first-page":"1564","DOI":"10.1007\/s00586-013-2789-2","volume":"22","author":"W Sutipornpalangkul","year":"2013","unstructured":"Sutipornpalangkul W, Thanapipatsiri S. Atlantoaxial transarticular screw fixation and posterior fusion using polyester cable: a 10-year experience. Eur Spine J. 2013;22(7):1564\u20139. https:\/\/doi.org\/10.1007\/s00586-013-2789-2.","journal-title":"Eur Spine J"},{"issue":"5","key":"7995_CR4","doi-asserted-by":"publisher","first-page":"843","DOI":"10.5137\/1019-5149.JTN.20022-17.1","volume":"28","author":"S Senturk","year":"2018","unstructured":"Senturk S, Akyoldas G, Yaman O, et al. A new technique for the surgical treatment of atlantoaxial instability: C1 lateral mass and C2-3 transfacet screwing. Turk Neurosurg. 2018;28(5):843\u20136. https:\/\/doi.org\/10.5137\/1019-5149.JTN.20022-17.1.","journal-title":"Turk Neurosurg"},{"issue":"8","key":"7995_CR5","doi-asserted-by":"publisher","first-page":"1374","DOI":"10.1016\/j.spinee.2017.12.003","volume":"18","author":"RJ Hlubek","year":"2018","unstructured":"Hlubek RJ, Bohl MA, Cole TS, et al. Safety and accuracy of freehand versus navigated C2 pars or pedicle screw placement. Spine J. 2018;18(8):1374\u201381. https:\/\/doi.org\/10.1016\/j.spinee.2017.12.003.","journal-title":"Spine J"},{"issue":"2","key":"7995_CR6","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1097\/00024720-200404000-00014","volume":"17","author":"NM Wright","year":"2004","unstructured":"Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech. 2004;17(2):158\u201362.","journal-title":"J Spinal Disord Tech"},{"issue":"5","key":"7995_CR7","doi-asserted-by":"publisher","first-page":"409","DOI":"10.3171\/spi.2005.3.5.0409","volume":"3","author":"NM Wright","year":"2005","unstructured":"Wright NM. Translaminar rigid screw fixation of the axis. Technical note. J Neurosurg Spine. 2005;3(5):409\u201314. https:\/\/doi.org\/10.3171\/spi.2005.3.5.0409.","journal-title":"J Neurosurg Spine"},{"issue":"11","key":"7995_CR8","doi-asserted-by":"publisher","first-page":"1543","DOI":"10.1007\/s00701-009-0459-2","volume":"151","author":"SM Kabir","year":"2009","unstructured":"Kabir SM, Casey AT. Modification of Wright\u2019s technique for C2 translaminar screw fixation: technical note[J]. Acta Neurochir(Wien). 2009;151(11):1543\u20137. https:\/\/doi.org\/10.1007\/s00701-009-0459-2.","journal-title":"Acta Neurochir(Wien)"},{"key":"7995_CR9","doi-asserted-by":"publisher","first-page":"e490","DOI":"10.1016\/j.wneu.2017.11.018","volume":"110","author":"SR Sheng","year":"2018","unstructured":"Sheng SR, Wang K, Nisar M, et al. A novel technique for cervical facet joint hyperplasia-spondylotic radiculopathy by laminar and lateral mass screw cofixations. World Neurosurg. 2018;110:e490\u20135. https:\/\/doi.org\/10.1016\/j.wneu.2017.11.018.","journal-title":"World Neurosurg"},{"issue":"12","key":"7995_CR10","doi-asserted-by":"publisher","first-page":"2771","DOI":"10.1007\/s00586-015-4165-x","volume":"24","author":"JA Engler","year":"2015","unstructured":"Engler JA, Smith ML. Use of intraoperative fluoroscopy for the safe placement of C2 laminar screws: technical note. Eur Spine J. 2015;24(12):2771\u20135. https:\/\/doi.org\/10.1007\/s00586-015-4165-x.","journal-title":"Eur Spine J"},{"key":"7995_CR11","doi-asserted-by":"publisher","unstructured":"Elgafy H, Pompo F, Vela R et al. Ipsilateral arcuate foramen and high-riding vertebral artery: implication on C1-C2 instrumentation. Spine J, 14(7): 1351\u20135. https:\/\/doi.org\/10.1016\/j.spinee.2014.01.054","DOI":"10.1016\/j.spinee.2014.01.054"},{"issue":"6","key":"7995_CR12","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.4184\/asj.2016.10.6.1141","volume":"10","author":"W Wajanavisit","year":"2016","unstructured":"Wajanavisit W, Lertudomphonwanit T, Fuangfa P, et al. Prevalence of high-riding vertebral artery and morphometry of c2 pedicles using a novel computed tomography reconstruction technique. Asian Spine J. 2016;10(6):1141\u20138. https:\/\/doi.org\/10.4184\/asj.2016.10.6.1141.","journal-title":"Asian Spine J"},{"issue":"4","key":"7995_CR13","doi-asserted-by":"publisher","first-page":"656","DOI":"10.1016\/j.spinee.2007.06.008","volume":"8","author":"A Jea","year":"2008","unstructured":"Jea A, Sheth RN, Vanni S, et al. Modification of Wright\u2019s technique for placement of bilateral crossing C2 translaminar screws: technical note[J]. Spine J. 2008;8(4):656\u201360. https:\/\/doi.org\/10.1016\/j.spinee.2007.06.008.","journal-title":"Spine J"},{"key":"7995_CR14","doi-asserted-by":"publisher","unstructured":"Sheng SR, Wang K, Nisar M et al. A Novel Technique for Cervical Facet Joint Hyperplasia-Spondylotic Radiculopathy by Laminar and Lateral Mass Screw Cofixations.World Neurosurg,2018, 10: e490\u20135. https:\/\/doi.org\/10.1016\/j.wneu.2017.11.018","DOI":"10.1016\/j.wneu.2017.11.018"},{"key":"7995_CR15","doi-asserted-by":"publisher","unstructured":"Nottmeier EW, Foy AB. Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance[J]. Eur Spine J 2008,17(4): 610\u20135. https:\/\/doi.org\/10.1007\/s00586-007-0557-x","DOI":"10.1007\/s00586-007-0557-x"},{"issue":"9","key":"7995_CR16","doi-asserted-by":"publisher","first-page":"1379","DOI":"10.1007\/s00586-009-1051-4","volume":"18","author":"S Lu","year":"2009","unstructured":"Lu S, Xu YQ, Zhang YZ, et al. A novel computer-assisted drill guide template for placement of C2 laminar screws[J]. Eur Spine J. 2009;18(9):1379\u201385. https:\/\/doi.org\/10.1007\/s00586-009-1051-4.","journal-title":"Eur Spine J"},{"key":"7995_CR17","doi-asserted-by":"publisher","unstructured":"Hu Y, Yuan ZS, Spiker WR et al. Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study[J]. Eur Spine J 2013,22(12):2770\u20136. https:\/\/doi.org\/10.1007\/s00586-013-2993-0","DOI":"10.1007\/s00586-013-2993-0"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07995-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-024-07995-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-07995-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,15]],"date-time":"2024-11-15T06:05:31Z","timestamp":1731650731000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-024-07995-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,15]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["7995"],"URL":"https:\/\/doi.org\/10.1186\/s12891-024-07995-w","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,15]]},"assertion":[{"value":"13 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 October 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was performed in accordance with the Declaration of Helsinki and was reviewed and approved by the ethics committee of Ningbo university, China. The number: CHEC2009-066.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All individuals providing cadaver specimens must sign an informed consent for cadaver donation at the Institute of Anatomy, Ningbo university. This consent includes the use for scientific research. The consent for cadaver donation was obtained from family members.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"All individuals providing cadaver specimens must sign an informed consent for cadaver donation at the Institute of Anatomy, Ningbo university. This consent includes the use of the cadaver for scientific research and publication.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"913"}}