{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:18:36Z","timestamp":1772165916515,"version":"3.50.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T00:00:00Z","timestamp":1736380800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T00:00:00Z","timestamp":1736380800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Klinikum rechts der Isar der Technischen Universit\u00e4t M\u00fcnchen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aims to describe a fixation technique for coronoid fractures using suture buttons, and to biomechanically evaluate this technique in comparison to screw fixation as a time-zero pilot study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>An O\u2019Driscoll type 2 anteromedial coronoid facet (AMCF) fracture was simulated in 20 fresh-frozen human elbows. The specimens were randomized into two groups and fracture fixation was performed with either a suture button system or a 3.5\u00a0mm cannulated screw. Ultimate load-to-failure (N) was then tested for each specimen.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The mean load-to-failure was 322.6\u2009\u00b1\u200975.9\u00a0N for suture button fixation and 314.2\u2009\u00b1\u200985.9\u00a0N for screw fixation. The differences were not statistically significant (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.432). Additional fracturing of the coronoid fragment was observed in two specimens with screw fixation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Promising biomechanical evaluations show that this fixation technique using suture buttons in the treatment of coronoid fractures provides equal construct stability as screw fixation. Further studies are required to fully validate this procedure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-024-08209-z","type":"journal-article","created":{"date-parts":[[2025,1,8]],"date-time":"2025-01-08T23:33:07Z","timestamp":1736379187000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Suture button systems for coronoid fracture fixation: a biomechanical time-zero pilot study"],"prefix":"10.1186","volume":"26","author":[{"given":"Sebastian","family":"Lappen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pavel","family":"Kadantsev","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Bohnet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephanie","family":"Geyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian","family":"Hinz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Marx","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sepp","family":"Braun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Siebenlist","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,1,9]]},"reference":[{"key":"8209_CR1","first-page":"157","volume":"47","author":"BF Morrey","year":"1998","unstructured":"Morrey BF. Complex instability of the elbow. Instr Course Lect. 1998;47:157\u201364.","journal-title":"Instr Course Lect"},{"issue":"11","key":"8209_CR2","doi-asserted-by":"publisher","first-page":"e451","DOI":"10.1097\/BOT.0000000000001266","volume":"32","author":"J Morellato","year":"2018","unstructured":"Morellato J, Louati H, Desloges W, Papp S, Pollock JW. Fixation of Anteromedial Coronoid Facet fractures: a biomechanical evaluation of plated Versus Screw constructs. J Orthop Trauma. 2018;32(11):e451\u20136. https:\/\/doi.org\/10.1097\/BOT.0000000000001266.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"8209_CR3","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1016\/j.jse.2020.06.037","volume":"30","author":"WT Oh","year":"2021","unstructured":"Oh WT, Do WS, Oh JC, Koh IH, Kang HJ, Choi YR. Comparison of arthroscopy-assisted vs. open reduction and fixation of coronoid fractures of the ulna. J Shoulder Elb Surg. 2021;30(3):469\u201378. https:\/\/doi.org\/10.1016\/j.jse.2020.06.037.","journal-title":"J Shoulder Elb Surg"},{"issue":"4","key":"8209_CR4","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1177\/0363546519858745","volume":"48","author":"C Wang","year":"2020","unstructured":"Wang C, Meng JH, Zhang YW, Shi MM. Suture Button Versus Hook plate for Acute Unstable Acromioclavicular Joint dislocation: a Meta-analysis. Am J Sports Med. 2020;48(4):1023\u201330. https:\/\/doi.org\/10.1177\/0363546519858745.","journal-title":"Am J Sports Med"},{"issue":"4","key":"8209_CR5","doi-asserted-by":"publisher","first-page":"232596711770285","DOI":"10.1177\/2325967117702854","volume":"5","author":"PF Forschner","year":"2017","unstructured":"Forschner PF, Beitzel K, Imhoff AB, Buchmann S, Feuerriegel G, Hofmann F, et al. Five-year outcomes after treatment for Acute instability of the Tibiofibular Syndesmosis using a suture-button fixation system. Orthop J Sports Med. 2017;5(4):2325967117702854. https:\/\/doi.org\/10.1177\/2325967117702854.","journal-title":"Orthop J Sports Med"},{"issue":"3","key":"8209_CR6","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1007\/s00064-019-00626-x","volume":"32","author":"P Forkel","year":"2020","unstructured":"Forkel P, Imhoff AB, Achtnich A, Willinger L. [All-arthroscopic fixation of tibial posterior cruciate ligament avulsion fractures with a suture-button technique]. Oper Orthop Traumatol. 2020;32(3):236\u201347. https:\/\/doi.org\/10.1007\/s00064-019-00626-x.","journal-title":"Oper Orthop Traumatol"},{"issue":"3","key":"8209_CR7","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1007\/s00064-013-0280-1","volume":"26","author":"G Seppel","year":"2014","unstructured":"Seppel G, Lenich A, Imhoff AB. [Distal clavicle fracture]. Oper Orthop Traumatol. 2014;26(3):254\u201362. https:\/\/doi.org\/10.1007\/s00064-013-0280-1.","journal-title":"Oper Orthop Traumatol"},{"issue":"11","key":"8209_CR8","doi-asserted-by":"publisher","first-page":"e1319","DOI":"10.1016\/j.eats.2019.07.007","volume":"8","author":"A Wafaisade","year":"2019","unstructured":"Wafaisade A, Pfeiffer TR, Balke M, Guenther D, Koenen P. Arthroscopic transosseous suture button fixation technique for treatment of large anterior glenoid fracture. Arthrosc Tech. 2019;8(11):e1319\u201326. https:\/\/doi.org\/10.1016\/j.eats.2019.07.007.","journal-title":"Arthrosc Tech"},{"issue":"11","key":"8209_CR9","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1016\/j.injury.2018.09.032","volume":"49","author":"EM Kiskaddon","year":"2018","unstructured":"Kiskaddon EM, Wright A, Meeks BD, Froehle AW, Gould GC, Lubitz MG, et al. A biomechanical cadaver comparison of suture button fixation to plate fixation for pubic symphysis diastasis. Injury. 2018;49(11):1993\u20138. https:\/\/doi.org\/10.1016\/j.injury.2018.09.032.","journal-title":"Injury"},{"key":"8209_CR10","first-page":"113","volume":"52","author":"SW O\u2019Driscoll","year":"2003","unstructured":"O\u2019Driscoll SW, Jupiter JB, Cohen MS, Ring D, McKee MD. Difficult elbow fractures: pearls and pitfalls. Instr Course Lect. 2003;52:113\u201334.","journal-title":"Instr Course Lect"},{"issue":"9","key":"8209_CR11","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1007\/s00402-020-03621-1","volume":"141","author":"V Rausch","year":"2021","unstructured":"Rausch V, Jettkant B, Lotzien S, Rosteius T, Mempel E, Schildhauer TA, et al. Biomechanical comparison of screw osteosyntheses and anatomical plating for coronoid shear fractures of the ulna. Arch Orthop Trauma Surg. 2021;141(9):1509\u201315. https:\/\/doi.org\/10.1007\/s00402-020-03621-1.","journal-title":"Arch Orthop Trauma Surg"},{"key":"8209_CR12","doi-asserted-by":"publisher","first-page":"896790","DOI":"10.3389\/fbioe.2022.896790","volume":"10","author":"MC Jordan","year":"2022","unstructured":"Jordan MC, Hufnagel L, McDonogh M, Paul MM, Schmalzl J, Kupczyk E, et al. Surgical fixation of calcaneal beak fractures-biomechanical analysis of different osteosynthesis techniques. Front Bioeng Biotechnol. 2022;10:896790. https:\/\/doi.org\/10.3389\/fbioe.2022.896790.","journal-title":"Front Bioeng Biotechnol"},{"issue":"10","key":"8209_CR13","doi-asserted-by":"publisher","first-page":"2216","DOI":"10.2106\/JBJS.E.01127","volume":"88","author":"JN Doornberg","year":"2006","unstructured":"Doornberg JN, Ring DC. Fracture of the anteromedial facet of the coronoid process. J Bone Joint Surg Am. 2006;88(10):2216\u201324. https:\/\/doi.org\/10.2106\/JBJS.E.01127.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"8209_CR14","doi-asserted-by":"publisher","first-page":"40","DOI":"10.3121\/cmr.2008.753","volume":"6","author":"J Wells","year":"2008","unstructured":"Wells J, Ablove RH. Coronoid fractures of the elbow. Clin Med Res. 2008;6(1):40\u20134. https:\/\/doi.org\/10.3121\/cmr.2008.753.","journal-title":"Clin Med Res"},{"issue":"1","key":"8209_CR15","doi-asserted-by":"publisher","first-page":"e11","DOI":"10.1016\/j.jhsa.2016.11.003","volume":"42","author":"NP Iannuzzi","year":"2017","unstructured":"Iannuzzi NP, Paez AG, Parks BG, Murphy MS. Fixation of Regan-Morrey type II coronoid fractures: a comparison of screws and suture Lasso technique for resistance to displacement. J Hand Surg Am. 2017;42(1):e11\u20134. https:\/\/doi.org\/10.1016\/j.jhsa.2016.11.003.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"8209_CR16","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1097\/BOT.0b013e31819df8c9","volume":"23","author":"JG Moon","year":"2009","unstructured":"Moon JG, Zobitz ME, An KN, O\u2019Driscoll SW. Optimal screw orientation for fixation of coronoid fractures. J Orthop Trauma. 2009;23(4):277\u201380. https:\/\/doi.org\/10.1097\/BOT.0b013e31819df8c9.","journal-title":"J Orthop Trauma"},{"issue":"11","key":"8209_CR17","doi-asserted-by":"publisher","first-page":"2433","DOI":"10.1016\/j.injury.2017.08.066","volume":"48","author":"B Lubberts","year":"2017","unstructured":"Lubberts B, Vopat BG, Wolf JC, Longo UG, DiGiovanni CW, Guss D. Arthroscopically measured syndesmotic stability after screw vs. suture button fixation in a cadaveric model. Injury. 2017;48(11):2433\u20137. https:\/\/doi.org\/10.1016\/j.injury.2017.08.066.","journal-title":"Injury"},{"issue":"10","key":"8209_CR18","doi-asserted-by":"publisher","first-page":"1626","DOI":"10.1016\/j.jhsa.2010.07.020","volume":"35","author":"CC Kam","year":"2010","unstructured":"Kam CC, Jones CM, Fennema JL, Latta LL, Ouellette EA, Evans PJ. Suture-button construct for interosseous ligament reconstruction in longitudinal radioulnar dissociations: a biomechanical study. J Hand Surg Am. 2010;35(10):1626\u201332. https:\/\/doi.org\/10.1016\/j.jhsa.2010.07.020.","journal-title":"J Hand Surg Am"},{"issue":"12","key":"8209_CR19","doi-asserted-by":"publisher","first-page":"1981","DOI":"10.1016\/j.jhsa.2010.09.009","volume":"35","author":"ML Drake","year":"2010","unstructured":"Drake ML, Farber GL, White KL, Parks BG, Segalman KA. Restoration of longitudinal forearm stability using a suture button construct. J Hand Surg Am. 2010;35(12):1981\u20135. https:\/\/doi.org\/10.1016\/j.jhsa.2010.09.009.","journal-title":"J Hand Surg Am"},{"issue":"10","key":"8209_CR20","doi-asserted-by":"publisher","first-page":"892","DOI":"10.3113\/FAI.2010.0892","volume":"31","author":"S Ahmed","year":"2010","unstructured":"Ahmed S, Bolt B, McBryde A. Comparison of standard screw fixation versus suture button fixation in lisfranc ligament injuries. Foot Ankle Int. 2010;31(10):892\u20136. https:\/\/doi.org\/10.3113\/FAI.2010.0892.","journal-title":"Foot Ankle Int"},{"issue":"10","key":"8209_CR21","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1016\/j.arthro.2007.05.017","volume":"23","author":"JE Adams","year":"2007","unstructured":"Adams JE, Merten SM, Steinmann SP. Arthroscopic-assisted treatment of coronoid fractures. Arthroscopy. 2007;23(10):1060\u20135. https:\/\/doi.org\/10.1016\/j.arthro.2007.05.017.","journal-title":"Arthroscopy"},{"issue":"4","key":"8209_CR22","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1016\/j.jse.2020.09.008","volume":"30","author":"F Lanzerath","year":"2021","unstructured":"Lanzerath F, Hackl M, Wegmann K, Muller LP, Leschinger T. The treatment of anteromedial coronoid facet fractures: a systematic review. J Shoulder Elb Surg. 2021;30(4):942\u20138. https:\/\/doi.org\/10.1016\/j.jse.2020.09.008.","journal-title":"J Shoulder Elb Surg"},{"issue":"2","key":"8209_CR23","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1007\/s00167-010-1298-7","volume":"19","author":"K Atesok","year":"2011","unstructured":"Atesok K, Doral MN, Whipple T, Mann G, Mei-Dan O, Atay OA, et al. Arthroscopy-assisted fracture fixation. Knee Surg Sports Traumatol Arthrosc. 2011;19(2):320\u20139. https:\/\/doi.org\/10.1007\/s00167-010-1298-7.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"8209_CR24","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1007\/s00590-015-1601-x","volume":"25","author":"L Dei Giudici","year":"2015","unstructured":"Dei Giudici L, Di Muzio F, Bottegoni C, Chillemi C, Gigante A. The role of arthroscopy in articular fracture management: the lower limb. Eur J Orthop Surg Traumatol. 2015;25(5):807\u201313. https:\/\/doi.org\/10.1007\/s00590-015-1601-x.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"4","key":"8209_CR25","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/j.hcl.2023.05.006","volume":"39","author":"AR Bhashyam","year":"2023","unstructured":"Bhashyam AR, Chen N. Arthroscopic-assisted fracture fixation about the elbow. Hand Clin. 2023;39(4):587\u201395. https:\/\/doi.org\/10.1016\/j.hcl.2023.05.006.","journal-title":"Hand Clin"},{"issue":"3","key":"8209_CR26","doi-asserted-by":"publisher","first-page":"153","DOI":"10.11138\/jts\/2016.4.3.153","volume":"4","author":"P Arrigoni","year":"2016","unstructured":"Arrigoni P, D\u2019Ambrosi R, Cucchi D, Nicoletti S, Guerra E. Arthroscopic fixation of coronoid process fractures through coronoid tunnelling and capsular plication. Joints. 2016;4(3):153\u20138. https:\/\/doi.org\/10.11138\/jts\/2016.4.3.153.","journal-title":"Joints"},{"issue":"9","key":"8209_CR27","doi-asserted-by":"publisher","first-page":"1890","DOI":"10.1016\/j.jse.2022.03.026","volume":"31","author":"A Colozza","year":"2022","unstructured":"Colozza A, Menozzi M, Perna L, Cavaciocchi M, Martini I, Galavotti C, Padovani S. Results of arthroscopically assisted reduction and fixation of anteromedial facet coronoid fractures at short-term follow-up. J Shoulder Elb Surg. 2022;31(9):1890\u20137. https:\/\/doi.org\/10.1016\/j.jse.2022.03.026.","journal-title":"J Shoulder Elb Surg"},{"issue":"12","key":"8209_CR28","doi-asserted-by":"publisher","first-page":"3147","DOI":"10.1007\/s11999-008-0502-2","volume":"466","author":"MR Hausman","year":"2008","unstructured":"Hausman MR, Klug RA, Qureshi S, Goldstein R, Parsons BO. Arthroscopically assisted coronoid fracture fixation: a preliminary report. Clin Orthop Relat Res. 2008;466(12):3147\u201352. https:\/\/doi.org\/10.1007\/s11999-008-0502-2.","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"8209_CR29","doi-asserted-by":"publisher","first-page":"742","DOI":"10.3928\/01477447-20151119-04","volume":"38","author":"JM Lee","year":"2015","unstructured":"Lee JM, Yi Y, Kim JW. Arthroscopically assisted surgery for Coronoid fractures. Orthopedics. 2015;38(12):742\u20136. https:\/\/doi.org\/10.3928\/01477447-20151119-04.","journal-title":"Orthopedics"},{"issue":"1","key":"8209_CR30","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s13018-016-0505-8","volume":"12","author":"K Ouyang","year":"2017","unstructured":"Ouyang K, Wang D, Lu W, Xiong J, Xu J, Peng L, et al. Arthroscopic reduction and fixation of coronoid fractures with an exchange rod-a new technique. J Orthop Surg Res. 2017;12(1):9. https:\/\/doi.org\/10.1186\/s13018-016-0505-8.","journal-title":"J Orthop Surg Res"},{"key":"8209_CR31","doi-asserted-by":"publisher","first-page":"8512963","DOI":"10.1155\/2018\/8512963","volume":"2018","author":"N Shimada","year":"2018","unstructured":"Shimada N, ShirakiIt K, Saita K. Arthroscopic osteosynthesis for the treatment of coronoid process fractures: a Case Series. Case Rep Orthop. 2018;2018:8512963. https:\/\/doi.org\/10.1155\/2018\/8512963.","journal-title":"Case Rep Orthop"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-08209-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-024-08209-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-08209-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T00:03:35Z","timestamp":1736381015000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-024-08209-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,9]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8209"],"URL":"https:\/\/doi.org\/10.1186\/s12891-024-08209-z","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-3931899\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,9]]},"assertion":[{"value":"5 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethics Committee of the Technical University of Munich (2022-430-S-NP). The study was conducted in accordance with the Declaration of Helsinki. All body donors provided informed consent to MedCure (17906 NE Riverside Pkwy Ste 205 Portland, OR, 97230\u2009\u2212\u20097365 USA,\n                      \n                      ) to donate their bodies for scientific purposes.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"All body donors provided informed consent to MedCure (17906 NE Riverside Pkwy Ste 205 Portland, OR, 97230\u2009\u2212\u20097365 USA,\n                      \n                      ) to donate their bodies for scientific purposes and use the anonymized collected data for publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Sepp Braun is a consultant for Arthrex. Sebastian Siebenlist is a consultant for Arthrex, Medi Bayreuth, medartis AG and KLS Martin Group.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"32"}}