{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:39:09Z","timestamp":1792787949027,"version":"4.5.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,30]],"date-time":"2024-12-30T00:00:00Z","timestamp":1735516800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,12,30]],"date-time":"2024-12-30T00:00:00Z","timestamp":1735516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Central Guiding Local Science and Technology Development Special Fund Project","award":["ZYYD2022A03"],"award-info":[{"award-number":["ZYYD2022A03"]}]},{"name":"Tianshan Talent Technology Innovation Leading Talent - High-Level Leading Talent Project","award":["2022TSYCLJ0026"],"award-info":[{"award-number":["2022TSYCLJ0026"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-024-08221-3","type":"journal-article","created":{"date-parts":[[2024,12,30]],"date-time":"2024-12-30T00:17:24Z","timestamp":1735517844000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Locking compression plate as a sequential external fixator following the distraction phase for the treatment of tibial bone defects caused by fracture-related infection: experiences from 22 cases"],"prefix":"10.1186","volume":"25","author":[{"given":"Xiriaili","family":"Kadier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aierbanjiang","family":"Shali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yimurang","family":"Hamiti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sulong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alimu","family":"Keremu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aihemaitijiang","family":"Yusufu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,12,30]]},"reference":[{"issue":"1","key":"8221_CR1","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1038\/s41572-022-00396-0","volume":"8","author":"TF Moriarty","year":"2022","unstructured":"Moriarty TF, Metsemakers WJ, Morgenstern M, Hofstee MI, Vallejo Diaz A, Cassat JE, Wildemann B, Depypere M, Schwarz EM, Richards RG. Fracture-related infection. Nat Rev Dis Primers. 2022;8(1):67.","journal-title":"Nat Rev Dis Primers"},{"issue":"2","key":"8221_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/BOT.0000000000001896","volume":"35","author":"KD Tetsworth","year":"2021","unstructured":"Tetsworth KD, Burnand HG, Hohmann E, Glatt V. Classification of bone defects: an extension of the Orthopaedic Trauma Association Open fracture classification. J Orthop Trauma. 2021;35(2):71\u20136.","journal-title":"J Orthop Trauma"},{"issue":"7","key":"8221_CR3","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1007\/s00402-020-03525-0","volume":"141","author":"H Bezstarosti","year":"2021","unstructured":"Bezstarosti H, Metsemakers WJ, van Lieshout EMM, Voskamp LW, Kortram K, McNally MA, Marais LC, Verhofstad MHJ. Management of critical-sized bone defects in the treatment of fracture-related infection: a systematic review and pooled analysis. Arch Orthop Trauma Surg. 2021;141(7):1215\u201330.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"11","key":"8221_CR4","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.2106\/JBJS.18.00842","volume":"101","author":"A Masquelet","year":"2019","unstructured":"Masquelet A, Kanakaris NK, Obert L, Stafford P, Giannoudis PV. Bone repair using the Masquelet technique. J Bone Joint Surg Am. 2019;101(11):1024\u201336.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"8221_CR5","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1186\/s12891-016-1312-4","volume":"17","author":"ML Azi","year":"2016","unstructured":"Azi ML, Aprato A, Santi I, Kfuri M Jr., Masse A, Joeris A. Autologous bone graft in the treatment of post-traumatic bone defects: a systematic review and meta-analysis. BMC Musculoskelet Disord. 2016;17(1):465.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"8221_CR6","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1186\/s12891-020-03335-w","volume":"21","author":"Y Liu","year":"2020","unstructured":"Liu Y, Yushan M, Liu Z, Liu J, Ma C, Yusufu A. Complications of bone transport technique using the Ilizarov method in the lower extremity: a retrospective analysis of 282 consecutive cases over 10 years. BMC Musculoskelet Disord. 2020;21(1):354.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"8221_CR7","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1186\/s12893-022-01586-z","volume":"22","author":"K Liu","year":"2022","unstructured":"Liu K, Liu Y, Cai F, Fan C, Ren P, Yusufu A. Efficacy comparison of trifocal bone transport using unilateral external fixator for femoral and tibial bone defects caused by infection. BMC Surg. 2022;22(1):141.","journal-title":"BMC Surg"},{"issue":"12","key":"8221_CR8","doi-asserted-by":"publisher","first-page":"1667","DOI":"10.1302\/0301-620X.95B12.31507","volume":"95\u2013b","author":"CW Oh","year":"2013","unstructured":"Oh CW, Apivatthakakul T, Oh JK, Kim JW, Lee HJ, Kyung HS, Baek SG, Jung GH. Bone transport with an external fixator and a locking plate for segmental tibial defects. Bone Joint J. 2013;95\u2013b(12):1667\u201372.","journal-title":"Bone Joint J"},{"issue":"1","key":"8221_CR9","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1186\/s12891-024-07377-2","volume":"25","author":"X Maimaiti","year":"2024","unstructured":"Maimaiti X, Liu K, Yusufu A, Xie Z. Treatment of tibial bone defects caused by infection: a retrospective comparative study of bone transport using a combined technique of unilateral external fixation over an intramedullary nail versus circular external fixation over an intramedullary nail. BMC Musculoskelet Disord. 2024;25(1):284.","journal-title":"BMC Musculoskelet Disord"},{"issue":"11","key":"8221_CR10","doi-asserted-by":"publisher","first-page":"3201","DOI":"10.1007\/s00402-021-04104-7","volume":"142","author":"SJ Janssen","year":"2022","unstructured":"Janssen SJ, Kloen P. Supercutaneous locking compression plate in the treatment of infected non-union and open fracture of the leg. Arch Orthop Trauma Surg. 2022;142(11):3201\u201311.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"8221_CR11","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.injury.2009.08.022","volume":"41","author":"CH Ma","year":"2010","unstructured":"Ma CH, Wu CH, Yu SW, Yen CY, Tu YK. Staged external and internal less-invasive stabilisation system plating for open proximal tibial fractures. Injury. 2010;41(2):190\u20136.","journal-title":"Injury"},{"issue":"1","key":"8221_CR12","doi-asserted-by":"publisher","first-page":"514","DOI":"10.1186\/s12891-023-06527-2","volume":"24","author":"K Liu","year":"2023","unstructured":"Liu K, Jia Q, Wang X, Bahesutihan Y, Ma C, Ren P, Liu Y, Yusufu A. Complications associated with single-level bone transport for the treatment of tibial bone defects caused by fracture-related infection. BMC Musculoskelet Disord. 2023;24(1):514.","journal-title":"BMC Musculoskelet Disord"},{"key":"8221_CR13","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1097\/00003086-199001000-00011","volume":"250","author":"P D Paley","year":"1990","unstructured":"Paley P D. Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. Clin Orthop Relat Res. 1990;250:81\u2013104.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"8221_CR14","doi-asserted-by":"publisher","first-page":"e20","DOI":"10.2106\/JBJS.L.00479","volume":"96","author":"AM Vranceanu","year":"2014","unstructured":"Vranceanu AM, Bachoura A, Weening A, Vrahas M, Smith RM, Ring D. Psychological factors predict disability and pain intensity after skeletal trauma. J Bone Joint Surg Am. 2014;96(3):e20.","journal-title":"J Bone Joint Surg Am"},{"key":"8221_CR15","unstructured":"Abulaiti A, Yilihamu Y, Yasheng T, Alike Y, Yusufu A. The psychological impact of external fixation using the Ilizarov or Orthofix LRS method to treat tibial osteomyelitis with a bone defect. (1879\u2009\u2013\u20090267 (Electronic))."},{"issue":"1","key":"8221_CR16","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/00005131-200301000-00010","volume":"17","author":"GM Kerkhoffs","year":"2003","unstructured":"Kerkhoffs GM, Kuipers MM, Marti RK, Van der Werken C. External fixation with standard AO-plates: technique, indications, and results in 31 cases. J Orthop Trauma. 2003;17(1):61\u20134.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"8221_CR17","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1186\/s12891-023-06150-1","volume":"24","author":"H Su","year":"2023","unstructured":"Su H, Zhong S, Ma T, Wu W, Lu Y, Wang D. Biomechanical study of the stiffness of the femoral locking compression plate of an external fixator for lower tibial fractures. BMC Musculoskelet Disord. 2023;24(1):39.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"8221_CR18","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/s13018-021-02907-3","volume":"17","author":"D Bla\u017eevi\u0107","year":"2022","unstructured":"Bla\u017eevi\u0107 D, Kodvanj J, Adamovi\u0107 P, Vidovi\u0107 D, Trobonja\u010da Z, Sabali\u0107 S. Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis. J Orthop Surg Res. 2022;17(1):16.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"8221_CR19","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1186\/s12891-020-3144-5","volume":"21","author":"D Shi","year":"2020","unstructured":"Shi D, Liu K, Zhang H, Wang X, Li G, Zheng L. Investigating the biomechanical function of the plate-type external fixator in the treatment of tibial fractures: a biomechanical study. BMC Musculoskelet Disord. 2020;21(1):128.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"8221_CR20","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1302\/2046-3758.64.2000470","volume":"6","author":"BFH Ang","year":"2017","unstructured":"Ang BFH, Chen JY, Yew AKS, Chua SK, Chou SM, Chia SL, Koh JSB, Howe TS. Externalised locking compression plate as an alternative to the unilateral external fixator: a biomechanical comparative study of axial and torsional stiffness. Bone Joint Res. 2017;6(4):216\u201323.","journal-title":"Bone Joint Res"},{"issue":"Suppl 1","key":"8221_CR21","doi-asserted-by":"publisher","first-page":"S15","DOI":"10.1097\/BOT.0b013e31820711d3","volume":"25","author":"H Schmal","year":"2011","unstructured":"Schmal H, Strohm PC, Jaeger M, S\u00fcdkamp NP. Flexible fixation and fracture healing: do locked plating \u2018internal fixators\u2019 resemble external fixators? J Orthop Trauma. 2011;25(Suppl 1):S15\u201320.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 2","key":"8221_CR22","doi-asserted-by":"publisher","first-page":"B3","DOI":"10.1016\/S0020-1383(01)00120-6","volume":"32","author":"SM Perren","year":"2001","unstructured":"Perren SM. Evolution and rationale of locked internal fixator technology. Introductory Remarks Injury. 2001;32(Suppl 2):B3\u20139.","journal-title":"Introductory Remarks Injury"},{"issue":"1","key":"8221_CR23","first-page":"59","volume":"39","author":"C Yildiz","year":"2005","unstructured":"Yildiz C, Uzun O, Sinici E, Ate\u015falp AS, Oz\u015fahin A, Ba\u015fbozkurt M. [Psychiatric symptoms in patients treated with an Ilizarov external fixator]. Acta Orthop Traumatol Turc. 2005;39(1):59\u201363.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"1","key":"8221_CR24","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1186\/s13018-024-04655-6","volume":"19","author":"Q Jia","year":"2024","unstructured":"Jia Q, Peng Z, Huang A, Jiang S, Zhao W, Xie Z, Ma C. Is fracture management merely a physical process? Exploring the psychological effects of internal and external fixation. J Orthop Surg Res. 2024;19(1):231.","journal-title":"J Orthop Surg Res"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-08221-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-024-08221-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-024-08221-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,30]],"date-time":"2024-12-30T01:02:40Z","timestamp":1735520560000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-024-08221-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,30]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["8221"],"URL":"https:\/\/doi.org\/10.1186\/s12891-024-08221-3","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,30]]},"assertion":[{"value":"11 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was approved by the Ethics Committee of the First Affiliated Hospital of Xinjiang Medical University and carried out by the ethical standards set out in the Helsinki Declaration. Informed consent was received from all participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1088"}}