{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T00:03:03Z","timestamp":1793232183235,"version":"4.5.0"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,15]],"date-time":"2025-03-15T00:00:00Z","timestamp":1741996800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,3,15]],"date-time":"2025-03-15T00:00:00Z","timestamp":1741996800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-025-08503-4","type":"journal-article","created":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T21:14:01Z","timestamp":1741986841000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Increased risk of periprosthetic fracture associated with decreased aseptic loosening in C-stem compared with the Charnley Elite Plus in primary total hip arthroplasty: a minimum 10-year follow-up study"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-4096-0798","authenticated-orcid":false,"given":"Shota","family":"Nakagawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuichi","family":"Miyamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takushi","family":"Nakatani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiho","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taisei","family":"Kawamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiyuki","family":"Shinada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Iida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,15]]},"reference":[{"key":"8503_CR1","doi-asserted-by":"publisher","first-page":"961","DOI":"10.2106\/00004623-199307000-00002","volume":"75","author":"KR Schulte","year":"1993","unstructured":"Schulte KR, Callaghan JJ, Kelley SS, Johnston RC. The outcome of Charnley total hip arthroplasty with cement after a minimum twenty-year follow-up. The results of one surgeon. J Bone Joint Surg Am. 1993;75:961\u201375.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR2","doi-asserted-by":"crossref","unstructured":"Malchau H, Herberts P, Eisler T, Garellick G, S\u00f6derman P. The Swedish total hip replacement register. J Bone Joint Surg Am. 2002;84\u2013A;Suppl 2:2\u201320.","DOI":"10.2106\/00004623-200200002-00002"},{"key":"8503_CR3","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1302\/0301-620X.81B3.0810427","volume":"81","author":"BM Wroblewski","year":"1999","unstructured":"Wroblewski BM, Fleming PA, Siney PD. Charnley low-frictional torque arthroplasty of the hip. 20-to-30 year results. J Bone Joint Surg Br. 1999;81:427\u201330.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR4","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-67013-8","volume-title":"Low friction arthroplasty of the hip. Theory and practice","author":"J Charnley","year":"1979","unstructured":"Charnley J. Low friction arthroplasty of the hip. Theory and practice. 1st ed. New York: Springer; 1979.","edition":"1"},{"key":"8503_CR5","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1302\/0301-620X.57B3.297","volume":"57","author":"FA Weber","year":"1975","unstructured":"Weber FA, Charnley J. A radiological study of fractures of acrylic cement in relation to the stem of a femoral head prosthesis. J Bone Joint Surg Br. 1975;57:297\u2013301.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR6","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1302\/0301-620X.62B4.7430222","volume":"62\u2013B","author":"JR Loudon","year":"1980","unstructured":"Loudon JR, Charnley J. Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem. J Bone Joint Surg Br. 1980;62\u2013B:450\u20133.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR7","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1302\/0301-620X.75B2.8444947","volume":"75","author":"DM Dall","year":"1993","unstructured":"Dall DM, Learmonth ID, Solomon MI, Miles AW, Davenport JM. Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs. J Bone Joint Surg Br. 1993;75:259\u201365.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR8","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1302\/0301-620X.80B5.0800754","volume":"80","author":"G Shen","year":"1998","unstructured":"Shen G. Femoral stem fixation. An engineering interpretation of the long-term outcome of Charnley and Exeter stems. J Bone Joint Surg Br. 1998;80:754\u20136.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR9","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1302\/0301-620X.84B5.0840631","volume":"84","author":"MR Norton","year":"2002","unstructured":"Norton MR, Yarlagadda R, Anderson GH. Catastrophic failure of the elite plus total hip replacement, with a hylamer acetabulum and zirconia ceramic femoral head. J Bone Joint Surg Br. 2002;84:631\u20135.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR10","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1302\/0301-620X.85B4.13411","volume":"85","author":"RB Brokelman","year":"2003","unstructured":"Brokelman RB, van Loon CJ, Rijnberg WJ. Patient versus surgeon satisfaction after total hip arthroplasty. J Bone Joint Surg Br. 2003;85:495\u20138.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR11","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1302\/0301-620X.87B4.15917","volume":"87","author":"NP Walton","year":"2005","unstructured":"Walton NP, Darrah C, Shepstone L, Donell ST, Phillips H. The elite plus total hip arthroplasty: the need for radiological surveillance. J Bone Joint Surg Br. 2005;87:458\u201362.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR12","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1007\/s00264-005-0660-8","volume":"29","author":"M Rowsell","year":"2005","unstructured":"Rowsell M, Der Tavitian J, Birtwistle S, Power R. Survivorship of the Charnley elite plus cemented femoral stem. Int Orthop. 2005;29:214\u20138.","journal-title":"Int Orthop"},{"key":"8503_CR13","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1302\/0301-620X.88B2.17055","volume":"88","author":"J Hauptfleisch","year":"2006","unstructured":"Hauptfleisch J, Glyn-Jones S, Beard DJ, Gill HS, Murray DW. The premature failure of the Charnley Elite-Plus stem: a confirmation of RSA predictions. J Bone Joint Surg Br. 2006;88:179\u201383.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR14","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1302\/0301-620X.89B4.18665","volume":"89","author":"YH Kim","year":"2007","unstructured":"Kim YH, Kim JS, Yoon SH. Long-term survivorship of the Charnley elite plus femoral component in young patients. J Bone Joint Surg Br. 2007;89:449\u201354.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR15","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.1302\/0301-620X.89B10.19038","volume":"89","author":"M Nixon","year":"2007","unstructured":"Nixon M, Taylor G, Sheldon P, Iqbal SJ, Harper W. Does bone quality predict loosening of cemented total hip replacements? J Bone Joint Surg Br. 2007;89:1303\u20138.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR16","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1302\/0301-620X.91B6.21417","volume":"91","author":"B Ollivere","year":"2009","unstructured":"Ollivere B, Darrah C, Brankin RC, Donell ST, Walton NP. The continued value of clinical and radiological surveillance: the Charnley elite plus hip replacement system at 12 years. J Bone Joint Surg Br. 2009;91:720\u20134.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR17","doi-asserted-by":"publisher","first-page":"280","DOI":"10.3109\/17453674.2010.480937","volume":"81","author":"T von Schewelov","year":"2010","unstructured":"von Schewelov T, Sanz\u00e9n L, Besjakov J, Carlsson A. The Elite-Plus stem migrates more than the flanged Charnley stem. Acta Orthop. 2010;81:280\u20135.","journal-title":"Acta Orthop"},{"key":"8503_CR18","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1007\/s00776-012-0296-7","volume":"17","author":"T Irie","year":"2012","unstructured":"Irie T, Oyama M, Kita A, Sakamoto T, Funayama K. Medium-term result of elite plus hip arthroplasty: the second modular evolution of the original Charnley low-friction arthroplasty. J Orthop Sci. 2012;17:699\u2013704.","journal-title":"J Orthop Sci"},{"key":"8503_CR19","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/j.jos.2017.12.003","volume":"23","author":"K Goto","year":"2018","unstructured":"Goto K, Furuya Y, Oda K, Minami R, Sano K, Sugimoto M, et al. Long-term results of total hip arthroplasty using Charnley Elite-Plus stem and the effect of stem geometry on radiographic distal femoral cortical hypertrophy. J Orthop Sci. 2018;23:365\u201370.","journal-title":"J Orthop Sci"},{"issue":"Suppl 1","key":"8503_CR20","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1054\/arth.2001.28374","volume":"16","author":"BM Wroblewski","year":"2001","unstructured":"Wroblewski BM, Siney PD, Fleming PA. Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique, and 7 years of clinical experience. J Arthroplasty. 2001;16(Suppl 1):37\u201341.","journal-title":"J Arthroplasty"},{"key":"8503_CR21","first-page":"864","volume":"69","author":"S Imura","year":"1995","unstructured":"Imura S. Evaluation chart of hip joint functions. J Orthop Assoc. 1995;69:864\u20137. (in Japanese).","journal-title":"J Orthop Assoc"},{"key":"8503_CR22","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1302\/0301-620X.74B3.1587883","volume":"74","author":"RL Barrack","year":"1992","unstructured":"Barrack RL, Mulroy RD, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br. 1992;74:385\u20139.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR23","first-page":"477","volume":"19","author":"JL Fowler","year":"1988","unstructured":"Fowler JL, Gie GA, Lee AJ, Ling RS. Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am. 1988;19:477\u201389.","journal-title":"Orthop Clin North Am"},{"key":"8503_CR24","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;(141):17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"8503_CR25","doi-asserted-by":"publisher","first-page":"161","DOI":"10.2106\/00004623-199072020-00002","volume":"72","author":"RC Johnston","year":"1990","unstructured":"Johnston RC, Fitzgerald RH, Harris WH, Poss R, M\u00fcller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161\u20138.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR26","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.2106\/00004623-199711000-00002","volume":"79","author":"S Kobayashi","year":"1997","unstructured":"Kobayashi S, Takaoka K, Saito N, Hisa K. Factors affecting aseptic failure of fixation after primary Charnley total hip arthroplasty. Multivariate survival analysis. J Bone Joint Surg Am. 1997;79:1618\u201327.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR27","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.2106\/00004623-198264070-00017","volume":"64","author":"WH Harris","year":"1982","unstructured":"Harris WH, McCarthy JC, O\u2019Neill DA. Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am. 1982;64:1063\u20137.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR28","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1302\/0301-620X.70B4.3403604","volume":"70","author":"V Pacheco","year":"1988","unstructured":"Pacheco V, Shelley P, Wroblewski BM. Mechanical loosening of the stem in Charnley arthroplasties. Identification of the at risk factors. J Bone Joint Surg Br. 1988;70:596\u20139.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR29","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1080\/17453674.2016.1222804","volume":"87","author":"M Junnila","year":"2016","unstructured":"Junnila M, Laaksonen I, Eskelinen A, Pulkkinen P, Ivar Havelin L, Furnes O, et al. Implant survival of the most common cemented total hip devices from the nordic arthroplasty register association database. Acta Orthop. 2016;87:546\u201353.","journal-title":"Acta Orthop"},{"key":"8503_CR30","doi-asserted-by":"publisher","first-page":"813","DOI":"10.2106\/00004623-200404000-00022","volume":"86","author":"SN Sangiorgio","year":"2004","unstructured":"Sangiorgio SN, Ebramzadeh E, Longjohn DB, Dorr LD. Effects of dorsal flanges on fixation of a cemented total hip replacement femoral stem. J Bone Joint Surg Am. 2004;86:813\u201320.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR31","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1054\/arth.2001.23576","volume":"16","author":"J Alfaro-Adri\u00e1n","year":"2001","unstructured":"Alfaro-Adri\u00e1n J, Gill HS, Murray DW. Should total hip arthroplasty femoral components be designed to subside? A radiostereometric analysis study of the Charnley elite and Exeter stems. J Arthroplasty. 2001;16:598\u2013606.","journal-title":"J Arthroplasty"},{"key":"8503_CR32","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1007\/s11999-014-3876-3","volume":"473","author":"NA Bedard","year":"2015","unstructured":"Bedard NA, Callaghan JJ, Stefl MD, Liu SS. Systematic review of literature of cemented femoral components: what is the durability at minimum 20 years followup? Clin Orthop Relat Res. 2015;473:563\u201371.","journal-title":"Clin Orthop Relat Res"},{"key":"8503_CR33","doi-asserted-by":"publisher","first-page":"1367","DOI":"10.1016\/j.arth.2012.10.030","volume":"28","author":"B Purbach","year":"2013","unstructured":"Purbach B, Kay PR, Siney PD, Fleming PA, Wroblewski BM. The C-stem in clinical practice: fifteen-year follow-up of a triple tapered polished cemented stem. J Arthroplasty. 2013;28:1367\u201371.","journal-title":"J Arthroplasty"},{"key":"8503_CR34","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.jor.2022.02.002","volume":"30","author":"AS Walsh","year":"2022","unstructured":"Walsh AS, Pinjala M, Lokanathan S, Hossain S. Survivorship of the C-Stem total hip replacement using the French paradox technique. J Orthop. 2022;30:7\u201311.","journal-title":"J Orthop"},{"key":"8503_CR35","doi-asserted-by":"publisher","first-page":"4075","DOI":"10.1007\/s00402-021-04302-3","volume":"142","author":"K Baryeh","year":"2022","unstructured":"Baryeh K, Sochart DH. Post-operative peri-prosthetic fracture rates following the use of cemented polished taper-slip stems for primary total hip arthroplasty: a systematic review. Arch Orthop Trauma Surg. 2022;142:4075\u201385.","journal-title":"Arch Orthop Trauma Surg"},{"key":"8503_CR36","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1080\/17453674.2019.1582680","volume":"90","author":"HA Kazi","year":"2019","unstructured":"Kazi HA, Whitehouse SL, Howell JR, Timperley AJ. Not all cemented hips are the same: a register-based (NJR) comparison of taper-slip and composite beam femoral stems. Acta Orthop. 2019;90:214\u20139.","journal-title":"Acta Orthop"},{"key":"8503_CR37","doi-asserted-by":"crossref","unstructured":"Carli AV, Negus JJ, Haddad FS. Periprosthetic femoral fractures and trying to avoid them: what is the contribution of femoral component design to the increased risk of periprosthetic femoral fracture? Bone Joint J. 2017;99\u2013B(Suppl A):50\u20139.","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0220.R1"},{"key":"8503_CR38","doi-asserted-by":"publisher","first-page":"e167","DOI":"10.2106\/JBJS.M.00643","volume":"96","author":"TM Thien","year":"2014","unstructured":"Thien TM, Chatziagorou G, Garellick G, Furnes O, Havelin LI, M\u00e4kel\u00e4 K, et al. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the nordic arthroplasty register association database. J Bone Joint Surg Am. 2014;96:e167.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR39","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1080\/17453674.2019.1624339","volume":"90","author":"J Mohammed","year":"2019","unstructured":"Mohammed J, Mukka S, Hedbeck CJ, Chammout G, Gordon M, Sk\u00f6ldenberg O. Reduced periprosthetic fracture rate when changing from a tapered polished stem to an anatomical stem for cemented hip arthroplasty: an observational prospective cohort study with a follow-up of 2 years. Acta Orthop. 2019;90:427\u201332.","journal-title":"Acta Orthop"},{"key":"8503_CR40","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1080\/00016470410001708030","volume":"75","author":"R Sarvilinna","year":"2004","unstructured":"Sarvilinna R, Huhtala HSA, Sovelius RT, Halonen PJ, Nevalainen JK, Pajam\u00e4ki KJK. Factors predisposing to periprosthetic fracture after hip arthroplasty: a case (n\u2009=\u200931)-control study. Acta Orthop Scand. 2004;75:16\u201320.","journal-title":"Acta Orthop Scand"},{"key":"8503_CR41","doi-asserted-by":"publisher","first-page":"1600","DOI":"10.2106\/JBJS.19.01242","volume":"102","author":"JN Lamb","year":"2020","unstructured":"Lamb JN, Jain S, King SW, West RM, Pandit HG. Risk factors for revision of polished taper-slip cemented stems for periprosthetic femoral fracture after primary total hip replacement: a registry-based cohort study from the National joint registry for England, Wales, Northern Ireland and the Isle of man. J Bone Joint Surg Am. 2020;102:1600\u20138.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR42","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1302\/0301-620X.92B3.23151","volume":"92","author":"F El Masri","year":"2010","unstructured":"El Masri F, Kerboull L, Kerboull M, Courpied JP, Hamadouche M. Is the so-called \u2018French paradox\u2019 a reality? long-term survival and migration of the Charnley-Kerboull stem cemented line-to-line. J Bone Joint Surg Br. 2010;92:342\u20138.","journal-title":"J Bone Joint Surg Br"},{"key":"8503_CR43","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1097\/00003086-199209000-00007","volume":"282","author":"RS Nizard","year":"1992","unstructured":"Nizard RS, Sedel L, Christel P, Meunier A, Soudry M, Witvoet J. Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop Relat Res. 1992;282:53\u201363.","journal-title":"Clin Orthop Relat Res"},{"key":"8503_CR44","doi-asserted-by":"publisher","first-page":"69","DOI":"10.2106\/00004623-200201000-00011","volume":"84","author":"M Hamadouche","year":"2002","unstructured":"Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84:69\u201377.","journal-title":"J Bone Joint Surg Am"},{"key":"8503_CR45","doi-asserted-by":"publisher","first-page":"S604","DOI":"10.1016\/j.arth.2022.03.015","volume":"37","author":"K Alpaugh","year":"2022","unstructured":"Alpaugh K, Chiu YF, Zlotnicki JP, Bendich I, Valle AGD, Bostrom MPG, et al. Femoral component undersizing and alignment are risk factors for early periprosthetic femur fracture. J Arthroplasty. 2022;37:S604\u201310.","journal-title":"J Arthroplasty"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08503-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-08503-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08503-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T21:51:07Z","timestamp":1741989067000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08503-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,15]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8503"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-08503-4","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,15]]},"assertion":[{"value":"21 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Informed consent to participate was provided through an opt-out method. The research protocol was approved by the Institutional Review Board of Matsudo City General Hospital (No. R5-3) in compliance with the principles of the Declaration of Helsinki and its contemporary amendments.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"264"}}