{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T15:07:30Z","timestamp":1788793650625,"version":"build-2803163510"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T00:00:00Z","timestamp":1747267200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T00:00:00Z","timestamp":1747267200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Shenzhen Science and Technology Projects","award":["JCYJ20220530152214032"],"award-info":[{"award-number":["JCYJ20220530152214032"]}]},{"name":"Shenzhen Science and Technology Projects","award":["JCYJ20220530152213030"],"award-info":[{"award-number":["JCYJ20220530152213030"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-025-08722-9","type":"journal-article","created":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T06:46:30Z","timestamp":1747291590000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Biomechanical properties of off-axis screw in the treatment of vertical femoral neck fractures: a finite element analysis"],"prefix":"10.1186","volume":"26","author":[{"given":"Yimiao","family":"Lin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fengting","family":"Cui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhaofeng","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinjia","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiyuan","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,15]]},"reference":[{"issue":"3","key":"8722_CR1","doi-asserted-by":"publisher","first-page":"111317","DOI":"10.1016\/j.injury.2024.111317","volume":"55","author":"H Xian","year":"2024","unstructured":"Xian H, Cheng W, Xie W, Wang L, Luo D, Liu H, Lian K, Lin D. Does the angle between dynamic hip screw and anti-rotation screw affect the outcome of vertically oriented femoral neck fractures? A Biomechanical analysis and clinical results. Injury. 2024;55(3):111317.","journal-title":"Injury"},{"issue":"1","key":"8722_CR2","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1186\/s12891-024-08041-5","volume":"25","author":"X Zhang","year":"2024","unstructured":"Zhang X, Zhang Y, Huang S, Qi X, Li W, Lv Y, Zhu Z. Biomechanical effects of FNS on femoral neck fractures based on different reduction quality: finite element analysis. BMC Musculoskelet Disord. 2024;25(1):914.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"8722_CR3","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1186\/s12891-024-07319-y","volume":"25","author":"L Cai","year":"2024","unstructured":"Cai L, Zheng W, Chen C, Hu W, Chen H, Wang T. Comparison of young femoral neck fractures treated by femoral neck system, multiple cancellous screws and dynamic hip screws: a retrospectively comparison study. BMC Musculoskelet Disord. 2024;25(1):188.","journal-title":"BMC Musculoskelet Disord"},{"issue":"8","key":"8722_CR4","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","volume":"90","author":"F Liporace","year":"2008","unstructured":"Liporace F, Gaines R, Collinge C, Haidukewych GJ. Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. J Bone Joint Surg Am. 2008;90(8):1654\u20139.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"8722_CR5","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1186\/s13018-020-01724-4","volume":"15","author":"F Pei","year":"2020","unstructured":"Pei F, Zhao R, Li F, Chen X, Guo K, Zhu L. Osteonecrosis of femoral head in young patients with femoral neck fracture: a retrospective study of 250 patients followed for average of 7.5 years. J Orthop Surg Res. 2020;15(1):238.","journal-title":"J Orthop Surg Res"},{"key":"8722_CR6","doi-asserted-by":"crossref","unstructured":"Kingery MT, Lezak BA, Lin CC, Anil U, Bosco J. 3rd. Treatment of femoral neck fracture depends on surgeon subspecialty training. J Am Acad Orthop Surg 2025.","DOI":"10.5435\/JAAOS-D-24-00750"},{"issue":"1","key":"8722_CR7","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1186\/s13018-020-01842-z","volume":"15","author":"L Li","year":"2020","unstructured":"Li L, Zhao X, Yang X, Tang X, Liu M. Dynamic hip screws versus cannulated screws for femoral neck fractures: a systematic review and meta-analysis. J Orthop Surg Res. 2020;15(1):352.","journal-title":"J Orthop Surg Res"},{"key":"8722_CR8","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1302\/0301-620X.46B4.630","volume":"46","author":"RS Garden","year":"1964","unstructured":"Garden RS, STABILITY, AND UNION IN SUBCAPITAL FRACTURES OF THE FEMUR. J Bone Joint Surg Br. 1964;46:630\u201347.","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"8722_CR9","doi-asserted-by":"publisher","first-page":"110842","DOI":"10.1016\/j.injury.2023.110842","volume":"54","author":"D Jiang","year":"2023","unstructured":"Jiang D, Zhan S, Hai H, Wang L, Zhao J, Zhu Z, Wang T, Jia W. What makes vertical femoral neck fracture with posterior inferior comminution different? An analysis of Biomechanical features and optimal internal fixation strategy. Injury. 2023;54(8):110842.","journal-title":"Injury"},{"issue":"11","key":"8722_CR10","doi-asserted-by":"publisher","first-page":"1889","DOI":"10.1016\/j.injury.2019.07.020","volume":"50","author":"FC Kuan","year":"2019","unstructured":"Kuan FC, Hsu KL, Lin CL, Hong CK, Yeh ML, Su WR. Biomechanical properties of off-axis screw in Pauwels III femoral neck fracture fixation: bicortical screw construct is superior to unicortical screw construct. Injury. 2019;50(11):1889\u201394.","journal-title":"Injury"},{"issue":"1","key":"8722_CR11","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1186\/s13018-021-02619-8","volume":"16","author":"D Jiang","year":"2021","unstructured":"Jiang D, Zhan S, Cai Q, Hu H, Jia W. Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients. J Orthop Surg Res. 2021;16(1):473.","journal-title":"J Orthop Surg Res"},{"issue":"Suppl 4","key":"8722_CR12","doi-asserted-by":"publisher","first-page":"S10","DOI":"10.1016\/S0020-1383(17)30769-6","volume":"48","author":"JAM Guimar\u00e3es","year":"2017","unstructured":"Guimar\u00e3es JAM, Rocha LR, Noronha Rocha TH, Bonfim DC, da Costa RS, Dos Santos Cavalcanti A, Roesler CR, Perini Machado JA, Aguiar DP, Duarte MEL. Vertical femoral neck fractures in young adults: a closed fixation strategy using a transverse cancellous lag screw. Injury. 2017;48(Suppl 4):S10\u20136.","journal-title":"Injury"},{"issue":"1","key":"8722_CR13","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1186\/s13018-022-03157-7","volume":"17","author":"Z Han","year":"2022","unstructured":"Han Z, Taxi W, Jia H, Ji N, Cao D, Sun X, Han C, Xie M, Ma X, Dong Q. Multiple cannulated screw fixation of femoral neck fractures with comminution in young- and middle-aged patients. J Orthop Surg Res. 2022;17(1):280.","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"8722_CR14","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1097\/BOT.0000000000000014","volume":"28","author":"CA Collinge","year":"2014","unstructured":"Collinge CA, Mir H, Reddix R. Fracture morphology of high shear angle vertical femoral neck fractures in young adult patients. J Orthop Trauma. 2014;28(5):270\u20135.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"8722_CR15","doi-asserted-by":"publisher","first-page":"1949","DOI":"10.1007\/s00264-018-3798-x","volume":"42","author":"B Zhang","year":"2018","unstructured":"Zhang B, Liu J, Zhu Y, Zhang W. A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures. Int Orthop. 2018;42(8):1949\u201355.","journal-title":"Int Orthop"},{"issue":"1","key":"8722_CR16","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1186\/s12891-021-04638-2","volume":"22","author":"S Lin","year":"2021","unstructured":"Lin S, Shang J, Xing B, Wu B, Peng R, Wang G, Lu HD. Modified F configuration in the treatment of Pauwels type III femoral neck fracture: a finite element analysis. BMC Musculoskelet Disord. 2021;22(1):758.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"8722_CR17","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s13018-019-1097-x","volume":"14","author":"J Li","year":"2019","unstructured":"Li J, Zhao Z, Yin P, Zhang L, Tang P. Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis. J Orthop Surg Res. 2019;14(1):76.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"8722_CR18","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1186\/s13018-023-04415-y","volume":"18","author":"X Cheng","year":"2023","unstructured":"Cheng X, Yang Y, Zhu J, Li G, Chen W, Wang J, Zhang Q, Zhang Y. Finite element analysis of basicervical femoral neck fracture treated with proximal femoral bionic nail. J Orthop Surg Res. 2023;18(1):926.","journal-title":"J Orthop Surg Res"},{"issue":"3","key":"8722_CR19","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","volume":"46","author":"GP Slobogean","year":"2015","unstructured":"Slobogean GP, Sprague SA, Scott T, Bhandari M. Complications following young femoral neck fractures. Injury. 2015;46(3):484\u201391.","journal-title":"Injury"},{"issue":"2","key":"8722_CR20","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1111\/os.14337","volume":"17","author":"Y G\u00fcvercin","year":"2025","unstructured":"G\u00fcvercin Y, Yaylac\u0131 M, Dizdar A, \u00d6zdemir ME, Ay S, Yaylac\u0131 EU, Karahasano\u011flu U, Uygun H, Peker G. Biomechanical analysis and solution suggestions of screw replacement scenarios in femoral neck fracture surgeries: finite element method. Orthop Surg. 2025;17(2):614\u201323.","journal-title":"Orthop Surg"},{"issue":"1","key":"8722_CR21","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1186\/s12891-024-07550-7","volume":"25","author":"J Sun","year":"2024","unstructured":"Sun J, Wu L, Fang N, Qiao W, Liu L. A finite element analysis of a low-profile femoral neck system of screws in sleeves in a vertical femoral neck fracture model. BMC Musculoskelet Disord. 2024;25(1):446.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"8722_CR22","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1186\/s13018-021-02659-0","volume":"16","author":"Y Tang","year":"2021","unstructured":"Tang Y, Zhang Z, Wang L, Xiong W, Fang Q, Wang G. Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study. J Orthop Surg Res. 2021;16(1):504.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"8722_CR23","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1186\/s13018-021-02517-z","volume":"16","author":"H Hu","year":"2021","unstructured":"Hu H, Cheng J, Feng M, Gao Z, Wu J, Lu S. Clinical outcome of femoral neck system versus cannulated compression screws for fixation of femoral neck fracture in younger patients. J Orthop Surg Res. 2021;16(1):370.","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"8722_CR24","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1002\/jor.24881","volume":"39","author":"D Jiang","year":"2021","unstructured":"Jiang D, Zhan S, Wang L, Shi LL, Ling M, Hu H, Jia W. Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures. J Orthop Res. 2021;39(8):1669\u201380.","journal-title":"J Orthop Res"},{"issue":"8","key":"8722_CR25","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1016\/j.clinbiomech.2013.08.007","volume":"28","author":"MA Hawks","year":"2013","unstructured":"Hawks MA, Kim H, Strauss JE, Oliphant BW, Golden RD, Hsieh AH, Nascone JW, O\u2019Toole RV. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A Biomechanical analysis in cadaveric bone. Clin Biomech (Bristol Avon). 2013;28(8):886\u201391.","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"11","key":"8722_CR26","doi-asserted-by":"publisher","first-page":"3408","DOI":"10.1016\/j.injury.2021.07.014","volume":"52","author":"D Jiang","year":"2021","unstructured":"Jiang D, Zhan S, Cai Q, Hu H, Jia W. Long-term differences in clinical prognosis between crossed- and parallel-cannulated screw fixation in vertical femoral neck fractures of non-geriatric patients. Injury. 2021;52(11):3408\u201314.","journal-title":"Injury"},{"issue":"4","key":"8722_CR27","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1111\/os.12503","volume":"11","author":"Q Dong","year":"2019","unstructured":"Dong Q, Han Z, Zhang YG, Sun X, Ma XL. Comparison of transverse cancellous lag screw and ordinary cannulated screw fixations in treatment of vertical femoral neck fractures. Orthop Surg. 2019;11(4):595\u2013603.","journal-title":"Orthop Surg"},{"issue":"8","key":"8722_CR28","doi-asserted-by":"publisher","first-page":"1676","DOI":"10.1016\/j.injury.2016.03.014","volume":"47","author":"CM Hoshino","year":"2016","unstructured":"Hoshino CM, Christian MW, O\u2019Toole RV, Manson TT. Fixation of displaced femoral neck fractures in young adults: Fixed-angle devices or Pauwel. screws? Injury. 2016;47(8):1676\u201384.","journal-title":"screws? Injury"},{"key":"8722_CR29","doi-asserted-by":"crossref","unstructured":"Liu J, Zhang B, Yin B, Chen H, Sun H, Zhang W. Biomechanical evaluation of the modified cannulated screws fixation of unstable femoral neck fracture with comminuted posteromedial cortex. Biomed Res Int. 2019, 2019: 2584151.","DOI":"10.1155\/2019\/2584151"},{"key":"8722_CR30","doi-asserted-by":"crossref","unstructured":"Zhang B, Liu J, Zhang W. Ordinary cannulated compression screws or headless cannulated compression screws? a synthetic bone biomechanical research in the internal fixation of vertical femoral neck fracture. Biomed Res Int. 2018, 2018: 4898301.","DOI":"10.1155\/2018\/4898301"},{"issue":"1","key":"8722_CR31","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1186\/s13018-021-02335-3","volume":"16","author":"H Sun","year":"2021","unstructured":"Sun H, Shu LY, Sherrier MC, Zhu Y, Liu JW, Zhang W. Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults. J Orthop Surg Res. 2021;16(1):234.","journal-title":"J Orthop Surg Res"},{"issue":"7","key":"8722_CR32","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1002\/jor.22617","volume":"32","author":"M Steiner","year":"2014","unstructured":"Steiner M, Claes L, Ignatius A, Simon U, Wehner T. Disadvantages of interfragmentary shear on fracture healing\u2013mechanical insights through numerical simulation. J Orthop Res. 2014;32(7):865\u201372.","journal-title":"J Orthop Res"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08722-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-08722-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08722-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,15]],"date-time":"2025-05-15T06:46:35Z","timestamp":1747291595000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08722-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,15]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8722"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-08722-9","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,15]]},"assertion":[{"value":"10 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"We state that informed consent to participate was obtained from all of the participants in the study. We confirm that all experiments were performed in accordance with relevant guidelines and regulations. The study was approved by the Ethics Committee of the Shenzhen People\u2019s Hospital. Moreover, our study adhered to the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"479"}}