{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T14:50:17Z","timestamp":1794408617137,"version":"4.9.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T00:00:00Z","timestamp":1749168000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Chungnam National University Sejong Hospital Research Fund, 2023"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Several clinical and biomechanical studies on tension band wiring (TBW) using a ring-pin system have been conducted, but no consensus has been reached on the ideal surgical technique. In this study, we aimed to determine the ideal interval and length of ring pins for the treatment of transverse olecranon fractures using TBW with a ring-pin system.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A biomechanical study was performed using 32 fourth-generation composite ulnae and a ring-pin system specially designed for TBW. Four groups of eight sawbones were created based on the interval and length of the ring pins. A cyclic loading test was performed to measure stability during the active range of motion exercises. A load-to-failure test measured the maximal load until fixation loss.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>All groups were stable, with a micromotion of &lt;\u20091.0\u00a0mm, except for Group 3 (length: 50\u00a0mm, interval: 10\u00a0mm) during the cyclic loading test. The mean micromotion and displacement of Group 3 were significantly higher than those of Groups 2 and 4 (length: 90\u00a0mm, interval: 10\u00a0mm). The maximal load to failure in Group 3 was significantly lower than that of Groups 2 and 4.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Inserting two ring pins in parallel at a 10-mm interval with a length of \u2265\u200970\u00a0mm for TBW in transverse olecranon fractures is recommended. Further widening of the pin interval provides no biomechanical benefit and may result in technical difficulties owing to the anatomical features of the ulna; in summary, 50-mm ring pins show significantly lower mechanical strength.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12891-025-08828-0","type":"journal-article","created":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T03:31:02Z","timestamp":1749180662000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Ideal pin length and interval in tension band wiring using ring pins for transverse olecranon fractures: a biomechanical study"],"prefix":"10.1186","volume":"26","author":[{"given":"Seung Hoo","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Ho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,6]]},"reference":[{"key":"8828_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1302\/2058-5241.4.180022","volume":"4","author":"S Siebenlist","year":"2019","unstructured":"Siebenlist S, Buchholz A, Braun KF. Fractures of the proximal ulna: current concepts in surgical management. EFORT Open Rev. 2019;4:1\u20139.","journal-title":"EFORT Open Rev"},{"key":"8828_CR2","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1016\/j.jhsa.2012.12.036","volume":"38","author":"N Baecher","year":"2013","unstructured":"Baecher N, Edwards S. Olecranon fractures. J Hand Surg Am. 2013;38:593\u2013604.","journal-title":"J Hand Surg Am"},{"key":"8828_CR3","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/1749-799X-3-9","volume":"3","author":"BE Chalidis","year":"2008","unstructured":"Chalidis BE, Sachinis NC, Samoladas EP, Dimitriou CG, Pournaras JD. Is tension band wiring technique the gold standard for the treatment of olecranon fractures? A long term functional outcome study. J Orthop Surg Res. 2008;3:9.","journal-title":"J Orthop Surg Res"},{"key":"8828_CR4","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1016\/j.jse.2014.02.018","volume":"23","author":"ZM Saeed","year":"2014","unstructured":"Saeed ZM, Trickett RW, Yewlett AD, Matthews TJ. Factors influencing K-wire migration in tension-band wiring of olecranon fractures. J Shoulder Elb Surg. 2014;23:1181\u20136.","journal-title":"J Shoulder Elb Surg"},{"key":"8828_CR5","doi-asserted-by":"publisher","first-page":"847","DOI":"10.1007\/s00264-013-2208-7","volume":"38","author":"MM Schneider","year":"2014","unstructured":"Schneider MM, Nowak TE, Bastian L, Katthagen JC, Isenberg J, Rommens PM, et al. Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection. Int Orthop. 2014;38:847\u201355.","journal-title":"Int Orthop"},{"key":"8828_CR6","doi-asserted-by":"publisher","first-page":"1762","DOI":"10.1016\/j.jhsa.2013.05.012","volume":"38","author":"JY Kim","year":"2013","unstructured":"Kim JY, Lee YH, Gong HS, Lee SL, Lee SK, Baek GH. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures. J Hand Surg Am. 2013;38:1762\u20137.","journal-title":"J Hand Surg Am"},{"key":"8828_CR7","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s00590-019-02551-y","volume":"30","author":"M Okamoto","year":"2020","unstructured":"Okamoto M, Namba J, Kuriyama K, Miyamura S, Yokoi H, Yamamoto K. Surgical technique in tension band wiring method for selected comminuted olecranon fractures. Eur J Orthop Surg Traumatol. 2020;30:237\u201342.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"8828_CR8","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1007\/s00402-010-1156-6","volume":"131","author":"H Sadri","year":"2011","unstructured":"Sadri H, Stern R, Singh M, Linke B, Hoffmeyer P, Schwieger K. Transverse fractures of the olecranon: a Biomechanical comparison of three fixation techniques. Arch Orthop Trauma Surg. 2011;131:131\u20138.","journal-title":"Arch Orthop Trauma Surg"},{"key":"8828_CR9","doi-asserted-by":"publisher","first-page":"230949902110592","DOI":"10.1177\/23094990211059231","volume":"29","author":"H Shimura","year":"2021","unstructured":"Shimura H, Nimura A, Fujita K, Kaburagi H. Comparison of the efficacy of the tension band wiring with eyelet wire versus anatomical locking plate fixation for the treatment of displaced olecranon fractures. J Orthop Surg (Hong Kong). 2021;29:23094990211059231.","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"8828_CR10","doi-asserted-by":"publisher","first-page":"3282","DOI":"10.1016\/j.jbiomech.2008.08.013","volume":"41","author":"AD Heiner","year":"2008","unstructured":"Heiner AD. Structural properties of fourth-generation composite femurs and tibias. J Biomech. 2008;41:3282\u20134.","journal-title":"J Biomech"},{"key":"8828_CR11","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1097\/BOT.0b013e31829a25d2","volume":"28","author":"TB Jones","year":"2014","unstructured":"Jones TB, Karenz AR, Weinhold PS, Dahners LE. Transcortical screw fixation of the olecranon shows equivalent strength and improved stability compared with tension band fixation. J Orthop Trauma. 2014;28:137\u201342.","journal-title":"J Orthop Trauma"},{"key":"8828_CR12","doi-asserted-by":"publisher","first-page":"e28313","DOI":"10.1097\/MD.0000000000028313","volume":"101","author":"Y Lee","year":"2022","unstructured":"Lee Y, Cho BW, Kim MB, Lee YH. Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model. Medicine. 2022;101:e28313.","journal-title":"Medicine"},{"key":"8828_CR13","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1097\/00005131-199711000-00004","volume":"11","author":"MJ Prayson","year":"1997","unstructured":"Prayson MJ, Williams JL, Marshall MP, Scilaris TA, Lingenfelter EJ. Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study. J Orthop Trauma. 1997;11:565\u201372.","journal-title":"J Orthop Trauma"},{"key":"8828_CR14","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1016\/j.jse.2020.01.079","volume":"29","author":"KS Midtgaard","year":"2020","unstructured":"Midtgaard KS, S\u00f8reide E, Brattgjerd JE, Moatshe G, Madsen JE, Flugsrud GB. Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures. J Shoulder Elb Surg. 2020;29:1242\u20138.","journal-title":"J Shoulder Elb Surg"},{"key":"8828_CR15","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1007\/s007760070036","volume":"5","author":"JM Romero","year":"2000","unstructured":"Romero JM, Miran A, Jensen CH. Complications and re-operation rate after tension-band wiring of olecranon fractures. J Orthop Sci. 2000;5:318\u201320.","journal-title":"J Orthop Sci"},{"key":"8828_CR16","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/S0020-1383(00)00014-0","volume":"31","author":"JH Mullett","year":"2000","unstructured":"Mullett JH, Shannon F, Noel J, Lawlor G, Lee TC, O\u2019Rourke SK. K-wire position in tension band wiring of the olecranon - a comparison of two techniques. Injury. 2000;31:427\u201331.","journal-title":"Injury"},{"key":"8828_CR17","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.jse.2011.07.022","volume":"21","author":"SC van der Linden","year":"2012","unstructured":"van der Linden SC, van Kampen A, Jaarsma RL. K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures. J Shoulder Elb Surg. 2012;21:405\u201311.","journal-title":"J Shoulder Elb Surg"},{"key":"8828_CR18","doi-asserted-by":"publisher","first-page":"e6","DOI":"10.1016\/j.jse.2009.06.007","volume":"19","author":"SH Lee","year":"2010","unstructured":"Lee SH, Han SB, Jeong WK, Park JH, Park SY, Patil S. Ulnar artery pseudoaneurysm after tension band wiring of an olecranon fracture resulting in volkmann\u2019s ischemic contracture: a case report. J Shoulder Elb Surg. 2010;19:e6\u20138.","journal-title":"J Shoulder Elb Surg"},{"key":"8828_CR19","doi-asserted-by":"publisher","first-page":"480","DOI":"10.1097\/01.bot.0000164338.79013.10","volume":"19","author":"JJ Candal-Couto","year":"2005","unstructured":"Candal-Couto JJ, Williams JR, Sanderson PL. Impaired forearm rotation after tension-band-wiring fixation of olecranon fractures: evaluation of the transcortical K-wire technique. J Orthop Trauma. 2005;19:480\u20132.","journal-title":"J Orthop Trauma"},{"key":"8828_CR20","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1097\/BTH.0b013e3182a9128c","volume":"17","author":"N Takada","year":"2013","unstructured":"Takada N, Kato K, Fukuta M, Wada I, Otsuka T. Minimally invasive tension band wiring technique for olecranon fractures. Tech Hand Up Extrem Surg. 2013;17:199\u2013201.","journal-title":"Tech Hand Up Extrem Surg"},{"key":"8828_CR21","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1142\/S2424835521500545","volume":"26","author":"SH Lee","year":"2021","unstructured":"Lee SH, Kim MB, Lee YH. Simple osteotomy site repair method for the trans-olecranon approach: tension band wiring with ring pins. J Hand Surg Asian Pac Vol. 2021;26:571\u20139.","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"8828_CR22","doi-asserted-by":"publisher","first-page":"2506","DOI":"10.1016\/j.jhsa.2012.07.025","volume":"37","author":"J Hammond","year":"2012","unstructured":"Hammond J, Ruland R, Hogan C, Rose D, Belkoff S. Biomechanical analysis of a transverse olecranon fracture model using tension band wiring. J Hand Surg Am. 2012;37:2506\u201311.","journal-title":"J Hand Surg Am"},{"key":"8828_CR23","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1016\/j.jor.2022.09.015","volume":"34","author":"M Moon","year":"2022","unstructured":"Moon M, Schweser K, Bezold W, Cook JL. Biomechanical comparison of continuous compression implants versus tension band fixation for transverse olecranon fractures. J Orthop. 2022;34:316\u201321.","journal-title":"J Orthop"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08828-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-08828-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08828-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T12:54:20Z","timestamp":1750337660000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08828-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,6]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8828"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-08828-0","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,6]]},"assertion":[{"value":"5 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original version of this article was revised: the previous statement in the Funding information section, \u201cThis work was supported by one of the authors\u2019 Hospital Research Fund, 2023, \u201d has been updated to read, \u201cThis work was supported by the research fund of Chungnam National University Sejong Hospital, 2023, \u201d to accurately reflect the full institutional name of the funding source.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board of our hospital (No. NON2023-001). The need for informed consent was waived by the ethics committee because the study did not involve human participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"568"}}