{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:34:15Z","timestamp":1787020455984,"version":"build-2736575974"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T00:00:00Z","timestamp":1751587200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T00:00:00Z","timestamp":1751587200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Key Medical Research Project of Shanxi Province, Major Science and Technology Project","award":["2021XM02"],"award-info":[{"award-number":["2021XM02"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Anterior cervical discectomy and fusion (ACDF) is a common surgical procedure for treating cervical spine diseases, but its anterior approach can lead to complications such as dysphagia and carotid artery injury due to the large incision. However, performing ACDF under a percutaneous endoscopic approach can effectively mitigate these issues. Considering the need for smaller-sized cages in endoscopic procedures, this study explores the feasibility of using small-sized cages for percutaneous endoscopic ACDF surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The finite element method is used in this paper to construct cervical spine surgical models with three different sizes of cages implanted, studying the impact of size on cervical biomechanical performance. The dimensions of the cages remain constant in length and height, with a length of 14\u00a0mm and a height of 6\u00a0mm, and widths of 7\u00a0mm, 10\u00a0mm, and 14\u00a0mm, respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In a complete fusion state, the range of motion of the surgery level decreased, while adjacent segments showed a compensatory increase in range of motion. Intervertebral disc pressure increased in adjacent discs during flexion and extension. Facet joint pressure in the operated segments generally decreased across all conditions compared to the intact model, but in non-surgical segments exhibited varied compensatory increases under different conditions. Smaller cages led to increased von Mises stress on the cage and endplates, with stress distribution varying by motion condition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The results show that, using a 10\u00a0mm wide polyetheretherketone cage in complete fusion does not significantly affect postoperative vertebral stability or adjacent segment degeneration risk. Additionally, the risk of subsidence is relatively low, making it a suitable cage option for percutaneous endoscopic ACDF surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-025-08850-2","type":"journal-article","created":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T02:33:10Z","timestamp":1751596390000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Biomechanical effect of cage size in single-level anterior cervical discectomy and fusion: a finite element analysis"],"prefix":"10.1186","volume":"26","author":[{"given":"Qianqian","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusheng","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liming","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingfeng","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiyi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoyu","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,4]]},"reference":[{"key":"8850_CR1","doi-asserted-by":"publisher","first-page":"2728","DOI":"10.3390\/ijms24032728","volume":"24","author":"A Ruffilli","year":"2023","unstructured":"Ruffilli A, Viroli G, Neri S, Traversari M, Barile F, Manzetti M, Assirelli E, Ialuna M, Vita F, Faldini C. Mechanobiology of the human intervertebral disc: systematic review of the literature and future perspectives. Int J Mol Sci. 2023;24:2728.","journal-title":"Int J Mol Sci"},{"key":"8850_CR2","doi-asserted-by":"publisher","first-page":"790","DOI":"10.4103\/1673-5374.353485","volume":"18","author":"ZX Ren","year":"2023","unstructured":"Ren ZX, Xu JH, Cheng X, Xu GX, Long HQ. Pathophysiological mechanisms of chronic compressive spinal cord injury due to vascular events. Neural Regen Res. 2023;18:790\u20136.","journal-title":"Neural Regen Res"},{"key":"8850_CR3","doi-asserted-by":"publisher","first-page":"e1028","DOI":"10.1016\/j.wneu.2019.11.081","volume":"134","author":"T Lin","year":"2020","unstructured":"Lin T, Wang Z, Chen G, Liu W. Predictive effect of cervical sagittal parameters on conservative treatment of single-segment cervical spondylotic radiculopathy. World Neurosurg. 2020;134:e1028\u201336.","journal-title":"World Neurosurg"},{"key":"8850_CR4","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1186\/s12891-021-04772-x","volume":"22","author":"AG Bakken","year":"2021","unstructured":"Bakken AG, Eklund A, Warnqvist A, O\u2019Neill S, Ax\u00e9n I. The effect of two weeks of spinal manipulative therapy and home stretching exercises on pain and disability in patients with persistent or recurrent neck pain; a randomized controlled trial. BMC Musculoskelet Disord. 2021;22:903.","journal-title":"BMC Musculoskelet Disord"},{"key":"8850_CR5","first-page":"CD004871","volume":"2","author":"AR Gross","year":"2024","unstructured":"Gross AR, Lee H, Ezzo J, Chacko N, Gelley G, Forget M, Morien A, Graham N, Santaguida PL, Rice M, et al. Massage for neck pain. Cochrane Database Syst Rev. 2024;2:CD004871.","journal-title":"Cochrane Database Syst Rev"},{"key":"8850_CR6","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1097\/00007632-200003150-00004","volume":"25","author":"P Sampath","year":"2000","unstructured":"Sampath P, Bendebba M, Davis JD, Ducker TB. Outcome of patients treated for cervical myelopathy. A prospective, multicenter study with independent clinical review. Spine (Phila Pa 1976). 2000;25:670\u20136.","journal-title":"Spine (Phila Pa 1976)"},{"key":"8850_CR7","doi-asserted-by":"publisher","first-page":"607","DOI":"10.2106\/00004623-195840030-00009","volume":"40","author":"GW Smith","year":"1958","unstructured":"Smith GW, Robinson RA. The treatment of certain cervical-spine disorders by anterior removal of the intervertebral disc and interbody fusion. JBJS. 1958;40:607\u201324.","journal-title":"JBJS"},{"key":"8850_CR8","doi-asserted-by":"publisher","first-page":"2310","DOI":"10.1097\/BRS.0b013e318154c57e","volume":"32","author":"KN Fountas","year":"2007","unstructured":"Fountas KN, Kapsalaki EZ, Nikolakakos LG, Smisson HF, Johnston KW, Grigorian AA, Lee GP, Robinson JS. Anterior cervical discectomy and fusion associated complications. Spine. 2007;32:2310\u20137.","journal-title":"Spine"},{"key":"8850_CR9","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1097\/01.brs.0000254120.25411.ae","volume":"32","author":"MC Wang","year":"2007","unstructured":"Wang MC, Chan L, Maiman DJ, Kreuter W, Deyo RA. Complications and mortality associated with cervical spine surgery for degenerative disease in the United States. Spine. 2007;32:342\u20137.","journal-title":"Spine"},{"key":"8850_CR10","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1097\/BSD.0b013e31820ef328","volume":"24","author":"WC Tzaan","year":"2011","unstructured":"Tzaan WC. Anterior percutaneous endoscopic cervical discectomy for cervical intervertebral disc herniation: outcome, complications, and technique. J Spinal Disord Tech. 2011;24:421\u201331.","journal-title":"J Spinal Disord Tech"},{"key":"8850_CR11","first-page":"e26888","volume":"14","author":"G Tsalimas","year":"2022","unstructured":"Tsalimas G, Evangelopoulos DS, Benetos IS, Pneumaticos S. Dysphagia as a postoperative complication of anterior cervical discectomy and fusion. Cureus. 2022;14:e26888\u2013e26888.","journal-title":"Cureus"},{"key":"8850_CR12","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1080\/10255842.2020.1846186","volume":"24","author":"MS Sun","year":"2021","unstructured":"Sun MS, Yuchi CX, Cai XY, Du CF, Mo ZJ. Parametric study of anterior percutaneous endoscopic cervical discectomy (APECD). Comput Methods Biomech Biomed Engin. 2021;24:687\u201399.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"8850_CR13","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1007\/s00234-005-1436-y","volume":"47","author":"Y Ahn","year":"2005","unstructured":"Ahn Y, Lee SH, Chung SE, Park HS, Shin SW. Percutaneous endoscopic cervical discectomy for discogenic cervical headache due to soft disc herniation. Neuroradiology. 2005;47:924\u201330.","journal-title":"Neuroradiology"},{"key":"8850_CR14","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1055\/s-2007-985860","volume":"50","author":"S Ruetten","year":"2007","unstructured":"Ruetten S, Komp M, Merk H, Godolias G. A new full-endoscopic technique for cervical posterior foraminotomy in the treatment of lateral disc herniations using 6.9-Mm endoscopes: prospective 2-year results of 87 patients. Minim Invasive Neurosurg. 2007;50:219\u201326.","journal-title":"Minim Invasive Neurosurg"},{"key":"8850_CR15","doi-asserted-by":"publisher","first-page":"1677","DOI":"10.1007\/s00264-008-0684-y","volume":"33","author":"S Ruetten","year":"2009","unstructured":"Ruetten S, Komp M, Merk H, Godolias G. Full-endoscopic anterior decompression versus conventional anterior decompression and fusion in cervical disc herniations. Int Orthop. 2009;33:1677\u201382.","journal-title":"Int Orthop"},{"key":"8850_CR16","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.jot.2020.03.006","volume":"23","author":"C Chen","year":"2020","unstructured":"Chen C, Yuchi CX, Gao Z, Ma X, Zhao D, Li JW, Xu B, Zhang CQ, Wang Z, Du CF, et al. Comparative analysis of the biomechanics of the adjacent segments after minimally invasive cervical surgeries versus anterior cervical discectomy and fusion: a finite element study. J Orthop Translat. 2020;23:107\u201312.","journal-title":"J Orthop Translat"},{"key":"8850_CR17","doi-asserted-by":"publisher","first-page":"772853","DOI":"10.3389\/fbioe.2021.772853","volume":"9","author":"T He","year":"2021","unstructured":"He T, Zhang J, Yu T, Wu J, Yuan T, Liu R, Yun Z, Du H, Qi L, An J, et al. comparative analysis of the biomechanical characteristics after different minimally invasive surgeries for cervical spondylopathy: a finite element analysis. Front Bioeng Biotechnol. 2021;9:772853.","journal-title":"Front Bioeng Biotechnol"},{"key":"8850_CR18","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1177\/2192568218774576","volume":"9","author":"ZB Cheung","year":"2019","unstructured":"Cheung ZB, Gidumal S, White S, Shin J, Phan K, Osman N, Bronheim R, Vargas L, Kim JS, Cho SK. Comparison of anterior cervical discectomy and fusion with a stand-alone interbody cage versus a conventional cage-plate technique: a systematic review and meta-analysis. Glob Spine J. 2019;9:446\u201355.","journal-title":"Glob Spine J"},{"key":"8850_CR19","doi-asserted-by":"publisher","first-page":"949","DOI":"10.31616\/asj.2022.0295","volume":"17","author":"M Lin","year":"2023","unstructured":"Lin M, Paul R, Dhar UK, Doulgeris J, O\u2019connor TE, Tsai CT, Vrionis FD. A review of finite element modeling for anterior cervical discectomy and fusion. Asian Spine J. 2023;17:949.","journal-title":"Asian Spine J"},{"key":"8850_CR20","doi-asserted-by":"publisher","first-page":"160","DOI":"10.5435\/JAAOS-D-16-00390","volume":"25","author":"PB Suh","year":"2017","unstructured":"Suh PB, Puttlitz C, Lewis C, Bal BS, McGilvray K. The effect of cervical interbody cage morphology, material composition, and substrate density on cage subsidence. J Am Acad Orthop Surg. 2017;25:160\u20138.","journal-title":"J Am Acad Orthop Surg"},{"key":"8850_CR21","doi-asserted-by":"publisher","first-page":"16","DOI":"10.4055\/cios.2011.3.1.16","volume":"3","author":"JJ Yang","year":"2011","unstructured":"Yang JJ, Yu CH, Chang BS, Yeom JS, Lee JH, Lee C-K. Subsidence and nonunion after anterior cervical interbody fusion using a stand-alone polyetheretherketone (PEEK) cage. Clin Orthop Surg. 2011;3:16\u201323.","journal-title":"Clin Orthop Surg"},{"issue":"2","key":"8850_CR22","doi-asserted-by":"publisher","first-page":"022025","DOI":"10.1088\/1757-899X\/912\/2\/022025","volume":"912","author":"S Choudhury","year":"2020","unstructured":"Choudhury S, Raja D, Roy S, Datta S. Stress analysis of different types of cages in cervical vertebrae: a finite element study. IOP Conf Ser Mater Sci Eng. 2020;912(2):022025.","journal-title":"IOP Conf Ser Mater Sci Eng"},{"key":"8850_CR23","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.1007\/s00586-009-1085-7","volume":"18","author":"MA Finn","year":"2009","unstructured":"Finn MA, Brodke DS, Daubs M, Patel A, Bachus KN. Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty. Eur Spine J. 2009;18:1520\u20137.","journal-title":"Eur Spine J"},{"key":"8850_CR24","doi-asserted-by":"publisher","first-page":"2692","DOI":"10.1097\/00007632-200112150-00012","volume":"26","author":"MM Panjabi","year":"2001","unstructured":"Panjabi MM, Crisco JJ, Vasavada A, Oda T, Cholewicki J, Nibu K, Shin E. Mechanical properties of the human cervical spine as shown by three-dimensional load-displacement curves. Spine. 2001;26:2692\u2013700.","journal-title":"Spine"},{"key":"8850_CR25","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1227\/00006123-198007000-00014","volume":"7","author":"MM Panjabi","year":"1980","unstructured":"Panjabi MM, White AA. Basic biomechanics of the spine. Neurosurgery. 1980;7:76\u201393.","journal-title":"Neurosurgery"},{"key":"8850_CR26","volume-title":"Clinical biomechanics of the spine","author":"AA White","year":"1990","unstructured":"White AA, Panjabi MM. Clinical biomechanics of the spine. 2nd ed. Philadelphia: Lippincott; 1990. ISBN 978-0-397-50720-7.","edition":"2"},{"key":"8850_CR27","doi-asserted-by":"publisher","first-page":"7197","DOI":"10.2147\/IJN.S132041","volume":"12","author":"L Cao","year":"2017","unstructured":"Cao L, Chen Q, Jiang L-B, Yin XF, Bian C, Wang HR, Ma YQ, Li XQ, Li XL, Dong J. Bioabsorbable self-retaining PLA\/nano-sized Beta-TCP cervical spine interbody fusion cage in goat models: an in vivo study. Int J Nanomed. 2017;12:7197\u2013205.","journal-title":"Int J Nanomed"},{"key":"8850_CR28","first-page":"61","volume":"10","author":"MN Bucci","year":"2017","unstructured":"Bucci MN, Oh D, Cowan RS, Davis RJ, Jackson RJ, Tyndall DS, Nehls D. The ROI-C zero-profile anchored spacer for anterior cervical discectomy and fusion: biomechanical profile and clinical outcomes. Med Dev (Auckl). 2017;10:61\u20139.","journal-title":"Med Dev (Auckl.)"},{"key":"8850_CR29","first-page":"e17457","volume":"13","author":"KR Chin","year":"2021","unstructured":"Chin KR, Gohel NN, Aloise DM, Seale JA, Pandey DK, Pencle FJ. Effectiveness of a fully impregnated hydroxyapatite polyetheretherketone cage on fusion in anterior cervical spine surgery. Cureus. 2021;13:e17457\u2013e17457.","journal-title":"Cureus"},{"key":"8850_CR30","doi-asserted-by":"publisher","first-page":"2814","DOI":"10.1007\/s00586-020-06454-z","volume":"29","author":"M Scholz","year":"2020","unstructured":"Scholz M, Onal B, Schleicher P, Pingel A, Hoffmann C, Kandziora F. Two-level ACDF with a zero-profile stand-alone spacer compared to conventional plating: a prospective randomized single-center study. Eur Spine J. 2020;29:2814\u201322.","journal-title":"Eur Spine J"},{"key":"8850_CR31","doi-asserted-by":"publisher","first-page":"103760","DOI":"10.1016\/j.compbiomed.2020.103760","volume":"120","author":"W Hua","year":"2020","unstructured":"Hua W, Zhi J, Ke W, Wang B, Yang S, Li L, Yang C. Adjacent segment biomechanical changes after one- or two-level anterior cervical discectomy and fusion using either a zero-profile device or cage plus plate: a finite element analysis. Comput Biol Med. 2020;120:103760.","journal-title":"Comput Biol Med"},{"key":"8850_CR32","doi-asserted-by":"publisher","first-page":"E199","DOI":"10.1016\/j.wneu.2021.07.013","volume":"154","author":"PS Manickam","year":"2021","unstructured":"Manickam PS, Roy S, Shetty GM. Biomechanical evaluation of a novel S-type, dynamic zero-profile cage design for anterior cervical discectomy and fusion with variations in bone graft shape: a finite element analysis. World Neurosurg. 2021;154:E199\u2013214.","journal-title":"World Neurosurg"},{"key":"8850_CR33","doi-asserted-by":"publisher","first-page":"E678","DOI":"10.1016\/j.wneu.2019.01.152","volume":"125","author":"Y Xiong","year":"2019","unstructured":"Xiong Y, Xu L, Bi LY, Yang JZ, Wang FX, Qu Y, Zhao ZY, Yang YD, Zhao DY, Li CH, et al. Dynamic fusion process in the anterior cervical discectomy and fusion with self-locking stand-alone cages. World Neurosurg. 2019;125:E678\u201387.","journal-title":"World Neurosurg"},{"key":"8850_CR34","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1016\/j.wneu.2022.02.032","volume":"163","author":"M Lin","year":"2022","unstructured":"Lin M, Shapiro SZ, Engeberg ED, Tsai C-T, Vrionis FD. Finite element analysis of the effect of dynamic plating on two-level anterior cervical discectomy fusion biomechanics. World Neurosurg. 2022;163:e43\u201352.","journal-title":"World Neurosurg"},{"key":"8850_CR35","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1111\/os.13268","volume":"14","author":"S He","year":"2022","unstructured":"He S, Zhou Z, Shao X, Zhou L, Zhang C, Zhou X, Wu S, Chen K, Wang Y, Qian Z. Comparing the bridge-type zero-profile anchored spacer (ROI-C) interbody fusion cage system and anterior cervical discectomy and fusion (ACDF) with plating and cage system in cervical spondylotic myelopathy. Orthop Surg. 2022;14:1100\u20138.","journal-title":"Orthop Surg"},{"key":"8850_CR36","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1186\/s40001-022-00813-w","volume":"27","author":"J Zhang","year":"2022","unstructured":"Zhang J, Wang S, Tang X, Xiong W, Wu H, Liu C, Li F. Clinical and radiological comparison of the zero-profile anchored cage and traditional cage-plate fixation in single-level anterior cervical discectomy and fusion. Eur J Med Res. 2022;27:189.","journal-title":"Eur J Med Res"},{"key":"8850_CR37","first-page":"59","volume":"31","author":"H Wei","year":"2021","unstructured":"Wei H, Shunli K, Zehua J, Tengfei Z, Yidong L, Rusen Z. Self-locking stand-alone cage used from opposite approach for the treatment of adjacent segment disease after an anterior cervical corpectomy and fusion. Turk Neurosurg. 2021;31:59\u201366.","journal-title":"Turk Neurosurg"},{"key":"8850_CR38","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1055\/s-0042-1750837","volume":"17","author":"P Iampreechakul","year":"2022","unstructured":"Iampreechakul P, Choochaimangkhala P, Tirakotai W, Hangsapruek S, Puthkhao P, Tanpun A. Zero-profile anchored spacer (ROI-C) in the treatment of cervical adjacent segment disease. Asian J Neurosurg. 2022;17:209\u201317.","journal-title":"Asian J Neurosurg"},{"key":"8850_CR39","doi-asserted-by":"publisher","first-page":"918032","DOI":"10.3389\/fbioe.2022.918032","volume":"10","author":"W Liang","year":"2022","unstructured":"Liang W, Han B, Hai Y, Yang J, Yin P. Biomechanical analysis of the reasonable cervical range of motion to prevent non-fusion segmental degeneration after single-level ACDF. Front Bioeng Biotechnol. 2022;10:918032.","journal-title":"Front Bioeng Biotechnol"},{"key":"8850_CR40","doi-asserted-by":"publisher","first-page":"2431","DOI":"10.1097\/00007632-200211150-00003","volume":"27","author":"JC Eck","year":"2002","unstructured":"Eck JC, Humphreys SC, Lim TH, Jeong ST, Kim JG, Hodges SD, An HS. Biomechanical study on the effect of cervical spine fusion on adjacent-level intradiscal pressure and segmental motion. Spine. 2002;27:2431\u20134.","journal-title":"Spine"},{"key":"8850_CR41","doi-asserted-by":"publisher","first-page":"172","DOI":"10.3171\/2011.10.SPINE11116","volume":"16","author":"ML Prasarn","year":"2012","unstructured":"Prasarn ML, Baria D, Milne E, Latta L, Sukovich W. Adjacent-level biomechanics after single versus multilevel cervical spine fusion laboratory investigation. J Neurosurg Spine. 2012;16:172\u20137.","journal-title":"J Neurosurg Spine"},{"key":"8850_CR42","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1186\/s12891-021-04244-2","volume":"22","author":"J Sun","year":"2021","unstructured":"Sun J, Wang Q, Cai D, Gu W, Ma Y, Sun Y, Wei Y, Yuan F. A lattice topology optimization of cervical interbody fusion cage and finite element comparison with ZK60 and Ti-6Al-4V cages. BMC Musculoskelet Disord. 2021;22:390.","journal-title":"BMC Musculoskelet Disord"},{"key":"8850_CR43","doi-asserted-by":"publisher","first-page":"105481","DOI":"10.1016\/j.jmbbm.2022.105481","volume":"136","author":"J Luoma","year":"2022","unstructured":"Luoma J, Saarenpaa I, Rinne J, Frantzen J, Moritz N, Vallittu PK. Quasi-static loading of glass fiber-reinforced composite cervical fusion cage. J Mech Behav Biomed Mater. 2022;136:105481\u2013105481.","journal-title":"J Mech Behav Biomed Mater"},{"key":"8850_CR44","doi-asserted-by":"publisher","first-page":"e12923","DOI":"10.1016\/j.heliyon.2023.e12923","volume":"9","author":"B Sun","year":"2023","unstructured":"Sun B, Han Q, Sui F, Zhang A, Liu Y, Xia P, Wang J, Yang X. Biomechanical analysis of customized cage conforming to the endplate morphology in anterior cervical discectomy fusion: a finite element analysis. Heliyon. 2023;9:e12923\u2013e12923.","journal-title":"Heliyon"},{"key":"8850_CR45","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1007\/s00701-018-3490-3","volume":"160","author":"I Noordhoek","year":"2018","unstructured":"Noordhoek I, Koning MT, Jacobs WCH, Vleggeert-Lankamp CLA. Incidence and clinical relevance of cage subsidence in anterior cervical discectomy and fusion: a systematic review. Acta Neurochir (Wien). 2018;160:873\u201380.","journal-title":"Acta Neurochir (Wien)"},{"key":"8850_CR46","doi-asserted-by":"publisher","first-page":"E38","DOI":"10.1016\/j.wneu.2021.10.084","volume":"158","author":"C Onyedimma","year":"2022","unstructured":"Onyedimma C, Jallow O, Yolcu YU, Alvi MA, Goyal A, Ghaith AK, Bhatti AUR, Abode-Iyamah K, Quinones-Hinojosa A, Freedman BA, et al. Comparison of outcomes between cage materials used for patients undergoing anterior cervical discectomy and fusion with standalone cages: a systematic review and meta-analysis. World Neurosurg. 2022;158:E38\u201354.","journal-title":"World Neurosurg"},{"key":"8850_CR47","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1016\/j.prostr.2018.12.062","volume":"13","author":"G La Rosa","year":"2018","unstructured":"La Rosa G, Clienti C, Mineo R. Experimental tests on new titanium alloy interbody cervical cages. Procedia Struct Integrity. 2018;13:373\u20138.","journal-title":"Procedia Struct Integrity"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08850-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-08850-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08850-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T03:03:21Z","timestamp":1751598201000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-08850-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,4]]},"references-count":47,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8850"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-08850-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,4]]},"assertion":[{"value":"2 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study has been approved by the Ethics Committee of Shanxi Bethune Hospital, Shanxi Academy of Medical (Approval notice number YXLL-2022-147). The volunteer agreed to the trial protocol and informed consent was obtained from him. The research was performed following the Declaration of Helsinki principles.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"594"}}