{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:15:04Z","timestamp":1790774104470,"version":"4.1.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,9]],"date-time":"2025-07-09T00:00:00Z","timestamp":1752019200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,9]],"date-time":"2025-07-09T00:00:00Z","timestamp":1752019200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Plate fixation is a widely used surgical procedure for proximal humeral fracture; however, relatively high complication rates have been reported. To prevent the occurrence of proximal screw cut out, pegs with blunt tips have been introduced to replace traditional screws for fixation of the humeral head. However, few reports are available on the effect of using smooth pegs on surgical outcomes. In this study, we aimed to compare the postoperative outcomes of osteosynthesis using anatomical plates using all proximal screws and using all proximal pegs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We retrospectively identified 48 patients who underwent osteosynthesis using an anatomical locking plate for proximal humeral fractures. We divided the patients into a screw group (25 patients) and a peg group (23 patients) according to the devices used to fix the humeral head. We compared operative outcomes, postoperative shoulder functional scores, and postoperative complication rates between the two groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In terms of operative outcomes, the operation time was significantly shorter in the peg group than that in the screw group (94 [83\u2013105] min vs. 114 [98\u2013124] min,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001,\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.52). No significant differences in adjusted Constant score and American Shoulder and Elbow Surgeon score were observed at 1 year postoperatively between the two groups. However, the incidence of greater tuberosity reduction loss was significantly higher in the peg group than that in the screw group (17.4% vs. 0%,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.046, \u03c6\u2009=\u20090.32).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our study showed that the use of proximal pegs did not significantly affect postoperative shoulder functional outcomes, although it may reduce operative time. In three-part fractures involving the greater tuberosity, the use of proximal screws or plates with sufficient coverage of the greater tuberosity may be desirable to prevent reduction loss of the greater tuberosity.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-025-08917-0","type":"journal-article","created":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T08:39:01Z","timestamp":1752136741000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of surgical outcomes of osteosynthesis using anatomical locking plates with proximal screws and smooth pegs for proximal humeral fractures"],"prefix":"10.1186","volume":"26","author":[{"given":"Ryogo","family":"Furuhata","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Tanji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusaku","family":"Kamata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noboru","family":"Matsumura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,9]]},"reference":[{"key":"8917_CR1","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","volume":"37","author":"CM Court-Brown","year":"2006","unstructured":"Court-Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury. 2006;37:691\u20137. https:\/\/doi.org\/10.1016\/j.injury.2006.04.130.","journal-title":"Injury"},{"key":"8917_CR2","doi-asserted-by":"publisher","first-page":"e242","DOI":"10.1097\/BOT.0000000000000312","volume":"29","author":"JW Karl","year":"2015","unstructured":"Karl JW, Olson PR, Rosenwasser MP. The epidemiology of upper extremity fractures in the united states, 2009. J Orthop Trauma. 2015;29:e242\u20134. https:\/\/doi.org\/10.1097\/BOT.0000000000000312.","journal-title":"J Orthop Trauma"},{"key":"8917_CR3","doi-asserted-by":"publisher","first-page":"1935","DOI":"10.1007\/s00264-017-3652-6","volume":"42","author":"TE McMillan","year":"2018","unstructured":"McMillan TE, Johnstone AJ. Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions. Int Orthop. 2018;42:1935\u201342. https:\/\/doi.org\/10.1007\/s00264-017-3652-6.","journal-title":"Int Orthop"},{"key":"8917_CR4","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1007\/s11420-010-9194-8","volume":"7","author":"CN Cornell","year":"2011","unstructured":"Cornell CN, Ayalon O. Evidence for success with locking plates for fragility fractures. HSS J. 2011;7:164\u20139. https:\/\/doi.org\/10.1007\/s11420-010-9194-8.","journal-title":"HSS J"},{"issue":"Suppl 1","key":"8917_CR5","doi-asserted-by":"publisher","first-page":"S33","DOI":"10.1016\/S0020-1383(18)30300-0","volume":"49","author":"LL Nowak","year":"2018","unstructured":"Nowak LL, Dehghan N, McKee MD, Schemitsch EH. Plate fixation for management of humerus fractures. Injury. 2018;49(Suppl 1):S33\u20138. https:\/\/doi.org\/10.1016\/S0020-1383(18)30300-0.","journal-title":"Injury"},{"key":"8917_CR6","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","volume":"42","author":"RC Sproul","year":"2011","unstructured":"Sproul RC, Iyengar JJ, Devcic Z, Feeley BT. A systematic review of locking plate fixation of proximal humerus fractures. Injury. 2011;42:408\u201313. https:\/\/doi.org\/10.1016\/j.injury.2010.11.058.","journal-title":"Injury"},{"key":"8917_CR7","doi-asserted-by":"publisher","first-page":"2176","DOI":"10.1016\/j.injury.2019.11.002","volume":"50","author":"VC Panagiotopoulou","year":"2019","unstructured":"Panagiotopoulou VC, Varga P, Richards RG, Gueorguiev B, Giannoudis PV. Late screw-related complications in locking plating of proximal humerus fractures: A systematic review. Injury. 2019;50:2176\u201395. https:\/\/doi.org\/10.1016\/j.injury.2019.11.002.","journal-title":"Injury"},{"key":"8917_CR8","doi-asserted-by":"publisher","first-page":"215145932098539","DOI":"10.1177\/2151459320985399","volume":"11","author":"A Taskesen","year":"2020","unstructured":"Taskesen A, G\u00f6\u00e7er A, Uzel K, Yarad\u0131lm\u0131\u015f YU. Effect of osteoporosis on proximal humerus fractures. Geriatr Orthop Surg Rehabil. 2020;11:2151459320985399. https:\/\/doi.org\/10.1177\/2151459320985399.","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"8917_CR9","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.jse.2009.06.004","volume":"18","author":"C Thanasas","year":"2009","unstructured":"Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P. Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elb Surg. 2009;18:837\u201344. https:\/\/doi.org\/10.1016\/j.jse.2009.06.004.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR10","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","volume":"42","author":"D Krappinger","year":"2011","unstructured":"Krappinger D, Bizzotto N, Riedmann S, Kammerlander C, Hengg C, Kralinger FS. Predicting failure after surgical fixation of proximal humerus fractures. Injury. 2011;42:1283\u20138. https:\/\/doi.org\/10.1016\/j.injury.2011.01.017.","journal-title":"Injury"},{"key":"8917_CR11","doi-asserted-by":"publisher","first-page":"e0183164","DOI":"10.1371\/journal.pone.0183164","volume":"12","author":"Q Wang","year":"2017","unstructured":"Wang Q, Zhu Y, Liu Y, Wang L, Chen Y. Correlation between classification and secondary screw penetration in proximal humeral fractures. PLoS ONE. 2017;12:e0183164. https:\/\/doi.org\/10.1371\/journal.pone.0183164.","journal-title":"PLoS ONE"},{"key":"8917_CR12","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1007\/s00402-023-05130-3","volume":"144","author":"D Xu","year":"2024","unstructured":"Xu D, Tu Z, Ji M, Niu W, Xu W. Preventing secondary screw perforation following proximal humerus fracture after locking plate fixation: a new clinical prognostic risk stratification model. Arch Orthop Trauma Surg. 2024;144:651\u201362. https:\/\/doi.org\/10.1007\/s00402-023-05130-3.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1\u20137","key":"8917_CR13","doi-asserted-by":"publisher","first-page":"e113","DOI":"10.2106\/JBJS.K.00202","volume":"95","author":"BA Ponce","year":"2013","unstructured":"Ponce BA, Thompson KJ, Raghava P, Eberhardt AW, Tate JP, Volgas DA, et al. The role of medial comminution and Calcar restoration in varus collapse of proximal humeral fractures treated with locking plates. J Bone Joint Surg Am. 2013;95(1\u20137):e113. https:\/\/doi.org\/10.2106\/JBJS.K.00202.","journal-title":"J Bone Joint Surg Am"},{"key":"8917_CR14","doi-asserted-by":"publisher","first-page":"e103297","DOI":"10.1371\/journal.pone.0103297","volume":"9","author":"W Zhang","year":"2014","unstructured":"Zhang W, Zeng L, Liu Y, Pan Y, Zhang W, Zhang C, et al. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures. PLoS ONE. 2014;9:e103297. https:\/\/doi.org\/10.1371\/journal.pone.0103297.","journal-title":"PLoS ONE"},{"key":"8917_CR15","doi-asserted-by":"publisher","first-page":"1968","DOI":"10.1016\/j.jse.2015.06.028","volume":"24","author":"B Schliemann","year":"2015","unstructured":"Schliemann B, Seifert R, Rosslenbroich SB, Theisen C, W\u00e4hnert D, Raschke MJ, et al. Screw augmentation reduces motion at the bone-implant interface: a Biomechanical study of locking plate fixation of proximal humeral fractures. J Shoulder Elb Surg. 2015;24:1968\u201373. https:\/\/doi.org\/10.1016\/j.jse.2015.06.028.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR16","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1016\/j.jse.2011.09.017","volume":"21","author":"KA Egol","year":"2012","unstructured":"Egol KA, Sugi MT, Ong CC, Montero N, Davidovitch R, Zuckerman JD. Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. J Shoulder Elb Surg. 2012;21:741\u20138. https:\/\/doi.org\/10.1016\/j.jse.2011.09.017.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR17","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1177\/1758573218791166","volume":"11","author":"F Hansson","year":"2019","unstructured":"Hansson F, Riddar M, Ekelund A. Evaluation of open reduction and internal fixation of proximal humerus fractures using a locking plate with smooth pegs - A retrospective study. Shoulder Elb. 2019;11:411\u20138. https:\/\/doi.org\/10.1177\/1758573218791166.","journal-title":"Shoulder Elb"},{"key":"8917_CR18","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/j.jse.2009.11.003","volume":"19","author":"RA Schumer","year":"2010","unstructured":"Schumer RA, Muckley KL, Markert RJ, Prayson MJ, Heflin J, Konstantakos EK, et al. Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation. J Shoulder Elb Surg. 2010;19:495\u2013501. https:\/\/doi.org\/10.1016\/j.jse.2009.11.003.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR19","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1016\/j.jse.2012.04.005","volume":"22","author":"N Yamamoto","year":"2013","unstructured":"Yamamoto N, Hongo M, Berglund LJ, Sperling JW, Cofield RH, An KN, et al. Biomechanical analysis of a novel locking plate with smooth pegs versus a conventional locking plate with threaded screws for proximal humerus fractures. J Shoulder Elb Surg. 2013;22:445\u201350. https:\/\/doi.org\/10.1016\/j.jse.2012.04.005.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR20","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.medengphy.2018.12.004","volume":"63","author":"L Le","year":"2019","unstructured":"Le L, Jabran A, Peach C, Ren L. Effect of screw thread length on stiffness of proximal humerus locking plate constructs: a finite element study. Med Eng Phys. 2019;63:79\u201387. https:\/\/doi.org\/10.1016\/j.medengphy.2018.12.004.","journal-title":"Med Eng Phys"},{"key":"8917_CR21","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1186\/s13018-020-01846-9","volume":"15","author":"CY Chen","year":"2020","unstructured":"Chen CY, Chang HW, Hsieh SL, Chang CC, Tsai CH, Chen YW, et al. Preliminary clinical and radiographic outcomes of proximal humeral fractures: comparison of ALPS and PHILOS plating in Asian patients in Taiwan. J Orthop Surg Res. 2020;15:364. https:\/\/doi.org\/10.1186\/s13018-020-01846-9.","journal-title":"J Orthop Surg Res"},{"key":"8917_CR22","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/s13018-022-02947-3","volume":"17","author":"I B\u00f8nes","year":"2022","unstructured":"B\u00f8nes I, Karlberg AC, Liljeholm M, Fraser AN, Madsen JE, Fjalestad T. Pegs not superior to screws for fixation of fractures of the proximal humerus. J Orthop Surg Res. 2022;17:66. https:\/\/doi.org\/10.1186\/s13018-022-02947-3.","journal-title":"J Orthop Surg Res"},{"key":"8917_CR23","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1186\/s12891-023-06477-9","volume":"24","author":"A Dewarrat","year":"2023","unstructured":"Dewarrat A, Terrier A, Barimani B, Vauclair F. Comparison of the ALPS and PHILOS plating systems in proximal humeral fracture fixation - a retrospective study. BMC Musculoskelet Disord. 2023;24:371. https:\/\/doi.org\/10.1186\/s12891-023-06477-9.","journal-title":"BMC Musculoskelet Disord"},{"key":"8917_CR24","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.2106\/00004623-197052060-00001","volume":"52","author":"CS Neer 2nd","year":"1970","unstructured":"Neer CS 2. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am. 1970;52:1077\u201389.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"8917_CR25","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.jse.2004.01.034","volume":"13","author":"R Hertel","year":"2004","unstructured":"Hertel R, Hempfing A, Stiehler M, Leunig M. Predictors of humeral head ischemia after intracapsular fracture of the proximal humerus. J Shoulder Elb Surg. 2004;13(4):427\u201333. https:\/\/doi.org\/10.1016\/j.jse.2004.01.034.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR26","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.2106\/JBJS.16.00112","volume":"98","author":"M Schnetzke","year":"2016","unstructured":"Schnetzke M, Bockmeyer J, Porschke F, Studier-Fischer S, Gr\u00fctzner PA, Guehring T. Quality of reduction influences outcome after locked-plate fixation of proximal humeral Type-C fractures. J Bone Joint Surg Am. 2016;98:1777\u201385. https:\/\/doi.org\/10.2106\/JBJS.16.00112.","journal-title":"J Bone Joint Surg Am"},{"key":"8917_CR27","doi-asserted-by":"crossref","unstructured":"Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;(214):160\u20134.","DOI":"10.1097\/00003086-198701000-00023"},{"key":"8917_CR28","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/S1058-2746(09)80019-0","volume":"3","author":"RR Richards","year":"1994","unstructured":"Richards RR, An KN, Bigliani LU, Friedman RJ, Gartsman GM, Gristina AG, et al. A standardized method for the assessment of shoulder function. J Shoulder Elb Surg. 1994;3:347\u201352. https:\/\/doi.org\/10.1016\/S1058-2746(09)80019-0.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR29","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1007\/s00167-009-0744-x","volume":"17","author":"A Tavakkolizadeh","year":"2009","unstructured":"Tavakkolizadeh A, Ghassemi A, Colegate-Stone T, Latif A, Sinha J. Gender-specific constant score correction for age. Knee Surg Sports Traumatol Arthrosc. 2009;17:529\u201333. https:\/\/doi.org\/10.1007\/s00167-009-0744-x.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"8917_CR30","doi-asserted-by":"publisher","first-page":"2190","DOI":"10.1016\/j.jse.2020.06.020","volume":"29","author":"DM Rouleau","year":"2020","unstructured":"Rouleau DM, Balg F, Benoit B, Leduc S, Malo M, V\u00e9zina F, et al. Deltopectoral vs. deltoid split approach for proximal humerus fracture fixation with locking plate: a prospective randomized study (HURA). J Shoulder Elb Surg. 2020;29:2190\u20139. https:\/\/doi.org\/10.1016\/j.jse.2020.06.020.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR31","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1186\/s13018-023-03811-8","volume":"18","author":"N Sheng","year":"2023","unstructured":"Sheng N, Shi T, Wang Q, Wang L, Chen Y. Nonanatomic healing of the greater tuberosity after plating in proximal humeral fractures: a case control study. J Orthop Surg Res. 2023;18:374. https:\/\/doi.org\/10.1186\/s13018-023-03811-8.","journal-title":"J Orthop Surg Res"},{"key":"8917_CR32","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1016\/j.jse.2012.08.018","volume":"22","author":"J Mather","year":"2013","unstructured":"Mather J, MacDermid JC, Faber KJ, Athwal GS. Proximal humerus cortical bone thickness correlates with bone mineral density and can clinically rule out osteoporosis. J Shoulder Elb Surg. 2013;22:732\u20138. https:\/\/doi.org\/10.1016\/j.jse.2012.08.018.","journal-title":"J Shoulder Elb Surg"},{"key":"8917_CR33","doi-asserted-by":"publisher","first-page":"215145932311986","DOI":"10.1177\/21514593231198645","volume":"14","author":"R Furuhata","year":"2023","unstructured":"Furuhata R, Tanji A, Oki S, Kamata Y. Influence of proximal humeral cortical bone thickness on the radiographic outcome after osteosynthesis of proximal humeral fractures: propensity matching score analysis. Geriatr Orthop Surg Rehabil. 2023;14:21514593231198645. https:\/\/doi.org\/10.1177\/21514593231198645.","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"8917_CR34","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.3109\/09638288.2013.829529","volume":"36","author":"AT van de Water","year":"2014","unstructured":"van de Water AT, Shields N, Davidson M, Evans M, Taylor NF. Reliability and validity of shoulder function outcome measures in people with a proximal humeral fracture. Disabil Rehabil. 2014;36:1072\u20139. https:\/\/doi.org\/10.3109\/09638288.2013.829529.","journal-title":"Disabil Rehabil"},{"key":"8917_CR35","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1016\/j.injury.2022.11.043","volume":"54","author":"BE Haws","year":"2023","unstructured":"Haws BE, Samborski SA, Karnyski S, Soles G, Gorczyca JT, Nicandri GT, et al. Risk factors for loss of reduction following locked plate fixation of proximal humerus fractures in older adults. Injury. 2023;54:567\u201372. https:\/\/doi.org\/10.1016\/j.injury.2022.11.043.","journal-title":"Injury"},{"key":"8917_CR36","doi-asserted-by":"publisher","first-page":"408","DOI":"10.3390\/jcm11020408","volume":"11","author":"RO Dey Hazra","year":"2022","unstructured":"Dey Hazra RO, Illner J, Szewczyk K, Warnhoff M, Ellwein A, Blach RM, et al. Age-independent clinical outcome in proximal humeral fractures: 2-year results using the example of a precontoured locking plate. J Clin Med. 2022;11:408. https:\/\/doi.org\/10.3390\/jcm11020408.","journal-title":"J Clin Med"},{"key":"8917_CR37","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/j.jhsa.2008.01.006","volume":"33","author":"PA Martineau","year":"2008","unstructured":"Martineau PA, Waitayawinyu T, Malone KJ, Hanel DP, Trumble TE. Volar plating of AO C3 distal radius fractures: Biomechanical evaluation of locking screw and locking smooth Peg configurations. J Hand Surg Am. 2008;33:827\u201334. https:\/\/doi.org\/10.1016\/j.jhsa.2008.01.006.","journal-title":"J Hand Surg Am"},{"key":"8917_CR38","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.clinbiomech.2019.02.006","volume":"63","author":"B Schliemann","year":"2019","unstructured":"Schliemann B, Risse N, Frank A, M\u00fcller M, Michel P, Raschke MJ, et al. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures. Clin Biomech (Bristol). 2019;63:21\u20136. https:\/\/doi.org\/10.1016\/j.clinbiomech.2019.02.006.","journal-title":"Clin Biomech (Bristol)"},{"key":"8917_CR39","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1097\/BOT.0000000000001112","volume":"32","author":"DM Donohue","year":"2018","unstructured":"Donohue DM, Santoni BG, Stoops TK, Tanner G, Diaz MA, Mighell M. Biomechanical comparison of 3 inferiorly directed versus 3 superiorly directed locking screws on stability in a 3-part proximal humerus fracture model. J Orthop Trauma. 2018;32:306\u201312. https:\/\/doi.org\/10.1097\/BOT.0000000000001112.","journal-title":"J Orthop Trauma"},{"key":"8917_CR40","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1097\/BOT.0000000000000252","volume":"29","author":"SW Jung","year":"2015","unstructured":"Jung SW, Shim SB, Kim HM, Lee JH, Lim HS. Factors that influence reduction loss in proximal humerus fracture surgery. J Orthop Trauma. 2015;29:276\u201382. https:\/\/doi.org\/10.1097\/BOT.0000000000000252.","journal-title":"J Orthop Trauma"},{"key":"8917_CR41","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.jse.2009.09.005","volume":"19","author":"P Clavert","year":"2010","unstructured":"Clavert P, Adam P, Bevort A, Bonnomet F, Kempf JF. Pitfalls and complications with locking plate for proximal humerus fracture. J Shoulder Elb Surg. 2010;19:489\u201394. https:\/\/doi.org\/10.1016\/j.jse.2009.09.005.","journal-title":"J Shoulder Elb Surg"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08917-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-08917-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-08917-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T11:17:18Z","timestamp":1781608638000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-025-08917-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,9]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8917"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-08917-0","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,9]]},"assertion":[{"value":"5 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ashikaga Red Cross Hospital Independent Ethics Committee (No. 2022-27) and the National Hospital Organization Tokyo Medical Center Independent Ethics Committee (No. R20-141).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This retrospective study was performed according to the Declaration of Helsinki. Opt-out consent relies on implicit consent, where willingness to participate is tacit or presumed and can be retracted by active objections.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"668"}}