{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T19:18:23Z","timestamp":1763061503100,"version":"3.45.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-025-09154-1","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T19:12:29Z","timestamp":1763061149000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effect of different artifact reduction methods for quantitative computed tomography measurements of bone mineral density: a pilot study"],"prefix":"10.1186","volume":"26","author":[{"given":"Ranxu","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yijing","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Bai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zishuo","family":"Hou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunyu","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shushan","family":"Dong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ping","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"9154_CR1","volume-title":"Disuse Osteoporosis: Clinical and Mechanistic Insights","author":"T Rolvien","year":"2021","unstructured":"Rolvien T, Amling M. Disuse Osteoporosis: Clinical and Mechanistic Insights. Calcified Tissue Int; 2021."},{"key":"9154_CR2","doi-asserted-by":"crossref","unstructured":"Lau RY, Guo X. A review on current osteoporosis research: with special focus on disuse bone loss. J Osteoporos. 2011;2011:293808.","DOI":"10.4061\/2011\/293808"},{"key":"9154_CR3","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1016\/j.clinimag.2015.09.016","volume":"40","author":"SS Mao","year":"2016","unstructured":"Mao SS, Li D, Luo YT, Syed YS, Budoff MJ. Application of quantitative computed tomography for assessment of trabecular bone mineral density, microarchitecture and mechanical property. Clin Imag. 2016;40:330\u20138.","journal-title":"Clin Imag"},{"key":"9154_CR4","first-page":"115","volume":"36","author":"JJ Carey","year":"2018","unstructured":"Carey JJ, Buehring B. Current imaging techniques in osteoporosis. Clin Exp Rheumatol. 2018;36:115\u201326.","journal-title":"Clin Exp Rheumatol"},{"key":"9154_CR5","doi-asserted-by":"publisher","first-page":"229","DOI":"10.2217\/iim.12.13","volume":"4","author":"FE Boas","year":"2012","unstructured":"Boas FE, Fleischmann D. CT artifacts: causes and reduction techniques. Imag Med. 2012;4:229\u201340.","journal-title":"Imag Med"},{"key":"9154_CR6","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1148\/rg.273065087","volume":"27","author":"MJ Lee","year":"2007","unstructured":"Lee MJ, Kim SJ, Lee SA, Song HT, Huh YM, Kim DH, Han SH, Suh JS. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT. Radiographics. 2007;27:791\u2013803.","journal-title":"Radiographics"},{"key":"9154_CR7","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1148\/rg.246045065","volume":"24","author":"JF Barrett","year":"2004","unstructured":"Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics. 2004;24:1679\u201391.","journal-title":"Radiographics"},{"key":"9154_CR8","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1109\/23.775600","volume":"46","author":"BD Man","year":"1999","unstructured":"Man BD, DuPont P, Marchal G. Metal streak artifacts in X-ray computed tomography: a simulation study. IEEE Trans Nucl Sci. 1999;46:691.","journal-title":"IEEE Trans Nucl Sci"},{"key":"9154_CR9","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1148\/rg.2018170102","volume":"38","author":"M Katsura","year":"2018","unstructured":"Katsura M, Sato J, Akahane M, Kunimatsu A, Abe O. Current and novel techniques for metal artifact reduction at CT: practical guide for radiologists. Radiographics. 2018;38:450\u201361.","journal-title":"Radiographics"},{"key":"9154_CR10","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1007\/s12194-012-0179-9","volume":"6","author":"I Mori","year":"2013","unstructured":"Mori I, Machida Y, Osanai M, Linuma K. Photon starvation artifacts of X-ray CT: their true cause and a solution. Radiol Phys Technol. 2013;6:130\u201341.","journal-title":"Radiol Phys Technol"},{"key":"9154_CR11","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ejrad.2018.08.010","volume":"107","author":"RH Wellenberg","year":"2018","unstructured":"Wellenberg RH, Hakvoort ET, Slump CH, Boomsma MF, Maas M, Streekstra GJ. Metal artifact reduction techniques in musculoskeletal CT-imaging. Eur J Radiol. 2018;107:60\u20139.","journal-title":"Eur J Radiol"},{"key":"9154_CR12","doi-asserted-by":"publisher","first-page":"7507","DOI":"10.1118\/1.4762814","volume":"39","author":"H Li","year":"2012","unstructured":"Li H, Noel C, Chen H, Li HH, Low D, Moore K, Klahr P, Michalski J, Gay HA, Thorstad W, Mutic S. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy. Med Phys. 2012;39:7507\u201317.","journal-title":"Med Phys"},{"key":"9154_CR13","first-page":"1","volume":"6","author":"M Kidoh","year":"2017","unstructured":"Kidoh M, Utsunomiya D, Oda S, Nakaura T, Funama Y, Yuki H, Hirata K, Hatemura M, Namimoto T, Yamashita Y. CT venography after knee replacement surgery: comparison of dual-energy CT-based monochromatic imaging and single-energy metal artifact reduction techniques on a 320-row CT scanner. Acta Radiol Open. 2017;6:1\u20138.","journal-title":"Acta Radiol Open"},{"key":"9154_CR14","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.1007\/s00270-019-02326-2","volume":"42","author":"H Woo","year":"2019","unstructured":"Woo H, Chai JW, Choi YH, Jin KN. Metal artifact reduction for orthopedic prosthesis in lower extremity CT venography: evaluation of image quality and vessel conspicuity. Cardiovasc Intervent Radiol. 2019;42:1619\u201326.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"9154_CR15","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.clinimag.2019.12.018","volume":"60","author":"KR Laukamp","year":"2020","unstructured":"Laukamp KR, Hokamp NG, Alabar O, Obmann vc, Lennartz S, Zopfs D, Gilkeson R, Ramaiya N, Gupta A. Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction. Clin Imag. 2020;60:249\u201356.","journal-title":"Clin Imag"},{"key":"9154_CR16","doi-asserted-by":"publisher","first-page":"1981","DOI":"10.1007\/s00256-019-03248-3","volume":"48","author":"C Kosmas","year":"2019","unstructured":"Kosmas C, Hojjati M, Young PC, Abedi A, Gholamrezanezhad A, Rajiah P. Dual-layer spectral computerized tomography for metal artifact reduction: small versus large orthopedic devices. Skeletal Radiol. 2019;48:1981\u201390.","journal-title":"Skeletal Radiol"},{"key":"9154_CR17","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.2214\/AJR.18.19514","volume":"211","author":"HJ Yoo","year":"2018","unstructured":"Yoo HJ, Hong SH, Chung BM, Moon SJ, Choi JY, Chae HD, Chang MY. Metal artifact reduction in virtual monoenergetic spectral Dual-Energy CT of patients with metallic orthopedic implants in the distal radius. Am J Roentgenol. 2018;211:1083\u201391.","journal-title":"Am J Roentgenol"},{"key":"9154_CR18","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1007\/s00256-016-2377-8","volume":"45","author":"L Filograna","year":"2016","unstructured":"Filograna L, Magarelli N, Leone A, Waure CD, Calabro GE, Finkenstaedt T, Thali MJ, Bonomo L. Performances of low-dose dual-energy CT in reducing artifacts from implanted metallic orthopedic devices. Skeletal Radiol. 2016;45:937\u201347.","journal-title":"Skeletal Radiol"},{"key":"9154_CR19","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1007\/s00256-017-2776-5","volume":"47","author":"NG Hokamp","year":"2018","unstructured":"Hokamp NG, Neuhaus V, Abdullayev N, Laukamp K, Lennartz S, Mpotsaris A, Borggrefe J. Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms. Skeletal Radiol. 2018;47:195\u2013201.","journal-title":"Skeletal Radiol"},{"key":"9154_CR20","doi-asserted-by":"publisher","first-page":"7151","DOI":"10.1007\/s00330-021-07746-8","volume":"31","author":"L Pennig","year":"2021","unstructured":"Pennig L, Zopfs D, Gertz R, Bremm J, Zaeske C, Hokamp NG, Celik E, Goertz L, Langenbach M, Persigehl T, Gupta A, Borggrefe J, Lennartz S, Laukamp KR. Reduction of CT artifacts from cardiac implantable electronic devices using a combination of virtual monoenergetic images and post-processing algorithms. Eur Radiol. 2021;31:7151\u201361.","journal-title":"Eur Radiol"},{"key":"9154_CR21","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.ejrad.2018.12.008","volume":"111","author":"V Neuhaus","year":"2019","unstructured":"Neuhaus V, Hokamp NG, Zopfs D, Laukamp K, Lennartz S, Abdullayev N, Maintz D, Borggrefe J. Reducing artifacts from total hip replacements in dual layer detector CT: combination of virtual monoenergetic images and orthopedic metal artifact reduction. Eur J Radiol. 2019;111:14\u201320.","journal-title":"Eur J Radiol"},{"key":"9154_CR22","doi-asserted-by":"publisher","first-page":"5298","DOI":"10.1007\/s00330-020-06932-4","volume":"30","author":"HD Chae","year":"2020","unstructured":"Chae HD, Hong SH, Shin M, Choi JY, Yoo HJ. Combined use of virtual monochromatic images and projection-based metal artifact reduction methods in evaluation of total knee arthroplasty. Eur Radiol. 2020;30:5298\u2013307.","journal-title":"Eur Radiol"},{"key":"9154_CR23","doi-asserted-by":"publisher","first-page":"4524","DOI":"10.1007\/s00330-018-5414-2","volume":"28","author":"KR Laukamp","year":"2018","unstructured":"Laukamp KR, Lennartz S, Neuhaus VF, Hokamp NG, Rau R, Blanc ML, Abdullayev N, Mpotsaris A, Maintz D, Borggrefe J. CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar. Eur Radiol. 2018;28:4524\u201333.","journal-title":"Eur Radiol"},{"key":"9154_CR24","doi-asserted-by":"publisher","first-page":"2091","DOI":"10.3390\/jcm8122091","volume":"8","author":"SB Goodman","year":"2019","unstructured":"Goodman SB, Gallo J. Periprosthetic osteolysis: mechanisms, prevention and treatment. J Clin Med. 2019;8:2091.","journal-title":"J Clin Med"},{"key":"9154_CR25","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1007\/s00256-015-2206-5","volume":"44","author":"MF Boomsma","year":"2015","unstructured":"Boomsma MF, Slouwerhof I, Dalen JA, Edens MA, Mueller D, Milles J, Maas M. Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external Phantom. Skeletal Radiol. 2015;44:1597\u2013602.","journal-title":"Skeletal Radiol"},{"key":"9154_CR26","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/j.ejrad.2016.01.019","volume":"85","author":"MF Boomsma","year":"2016","unstructured":"Boomsma MF, Slouwerhof I, Lingen CV, Pakvis FM, Dalen JA, Edens MA, Ettema HB, Verheyen C. CT-based quantification of bone stock in large head metal-on-metal unilateral total hip replacements. Eur J Radiol. 2016;85:760\u20133.","journal-title":"Eur J Radiol"},{"issue":"6","key":"9154_CR27","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1080\/17453670610013169","volume":"77","author":"HS Bod\u00e9n","year":"2006","unstructured":"Bod\u00e9n HS, Sk\u00f6ldenberg OG, Salemyr MO, Lundberg HJ, Adolphson PY. Continuous bone loss around a tapered unce-mented femoral stem: a long-term evaluation with DEXA. Acta Orthop. 2006;77(6):877\u201385.","journal-title":"Acta Orthop"},{"key":"9154_CR28","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1007\/s00776-015-0722-8","volume":"20","author":"T Tapaninen","year":"2015","unstructured":"Tapaninen T, Kr\u00f6ger H, Venesmaa P. Periprosthetic BMD after cemented and uncemented total hip arthroplasty: a 10-year follow-up study. J Orthop Sci. 2015;20:657\u201362.","journal-title":"J Orthop Sci"},{"key":"9154_CR29","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1515\/BMT.2011.105","volume":"56","author":"K Zingler","year":"2011","unstructured":"Zingler K, Haeberle L, Kress A, Holzwarth U, Forst R, Mueller LA, Schmidt R. Comparison of cortical and cancellous bone remodeling of the pelvis after press-fit cup total hip arthroplasty dependent on patient and prosthesis-specific characteristics: a computed tomography-assisted osteodensitometry study in vivo. Biomed Tech (Berl). 2011;56:267\u201375.","journal-title":"Biomed Tech (Berl)"},{"key":"9154_CR30","doi-asserted-by":"publisher","first-page":"191","DOI":"10.2340\/17453674.2023.11635","volume":"94","author":"TS Robertson","year":"2023","unstructured":"Robertson TS, Pijls BG, Munn Z, Solomon LB, Nelissen RG, Callary SA. Change in CT-measured acetabular bone density following total hip arthroplasty: a systematic review and meta-analysis. Acta Orthop. 2023;94:191\u20139.","journal-title":"Acta Orthop"},{"key":"9154_CR31","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1007\/s00256-012-1458-6","volume":"42","author":"M Lewis","year":"2012","unstructured":"Lewis M, Reid K, Toms AP. Reducing the effects of metal artifact using high KeV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements. Skeletal Radiol. 2012;42:275\u201382.","journal-title":"Skeletal Radiol"},{"key":"9154_CR32","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1118\/1.4905106","volume":"42","author":"S Kuchenbecker","year":"2015","unstructured":"Kuchenbecker S, Faby S, Sawall S, Lell M, Kachelrieb M. Dual energy CT: how well can Pseudomonochromatic imaging reduce metal artifacts? Med Phys. 2015;42:1023\u201336.","journal-title":"Med Phys"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-09154-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-09154-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-09154-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T19:12:31Z","timestamp":1763061151000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-09154-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["9154"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-09154-1","relation":{},"ISSN":["1471-2474"],"issn-type":[{"type":"electronic","value":"1471-2474"}],"subject":[],"published":{"date-parts":[[2025,11,13]]},"assertion":[{"value":"9 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All animal samples were purchased from private farms. The purpose of sample usage was disclosed to the suppliers, and their informed consent was obtained. The procurement and use of these samples have been examined and approved by the Animal Ethics Committee of the Third Hospital of Hebei Medical University in compliance with the guidelines of the Chinese Animal Protection Committee for the use of animals. All methods of this test were performed in accordance with the relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1042"}}