{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T10:18:59Z","timestamp":1781691539176,"version":"3.54.5"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T00:00:00Z","timestamp":1757376000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T00:00:00Z","timestamp":1757376000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004047","name":"Karolinska Institute","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004047","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>This study evaluates the accuracy of an Artificial Intelligence (AI) system, specifically a convolutional neural network (CNN), in classifying elbow fractures using the detailed 2018 AO\/OTA fracture classification system.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A retrospective analysis of 5,367 radiograph exams visualizing the elbow from adult patients (2002\u20132016) was conducted using a deep neural network. Radiographs were manually categorized according to the 2018 AO\/OTA system by orthopedic surgeons. A pretrained Efficientnet B4 network with squeeze and excitation layers was fine-tuned. Performance was assessed against a test set of 208 radiographs reviewed independently by four orthopedic surgeons, with disagreements resolved via consensus.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The study evaluated 54 distinct fracture types, each with a minimum of 10 cases, ensuring adequate dataset representation. Overall fracture detection achieved an AUC of 0.88 (95% CI 0.83\u20130.93). The weighted mean AUC was 0.80 for proximal radius fractures, 0.86 for proximal ulna, and 0.85 for distal humerus. These results underscore the AI system\u2019s ability to accurately detect and classify a broad spectrum of elbow fractures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>AI systems, such as CNNs, can enhance clinicians\u2019 ability to identify and classify elbow fractures, offering a complementary tool to improve diagnostic accuracy and optimize treatment decisions. The findings suggest AI can reduce the risk of undiagnosed fractures, enhancing clinical outcomes and radiologic evaluation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12891-025-09161-2","type":"journal-article","created":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T06:46:06Z","timestamp":1757400366000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Use of artificial intelligence for classification of fractures around the elbow in adults according to the 2018 AO\/OTA classification system"],"prefix":"10.1186","volume":"26","author":[{"given":"Annelie","family":"Pettersson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Axenhus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teo","family":"Stukan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oscar","family":"Ljungberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans","family":"N\u00e5sell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali Sharif","family":"Razavian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max","family":"Gordon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,9]]},"reference":[{"key":"9161_CR1","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1055\/s-0033-1361587","volume":"17","author":"S Martin","year":"2013","unstructured":"Martin S, Sanchez E. Anatomy and biomechanics of the elbow joint. Semin Musculoskelet Radiol. 2013;17:429\u201336.","journal-title":"Semin Musculoskelet Radiol"},{"key":"9161_CR2","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1016\/j.rcl.2019.03.006","volume":"57","author":"TY Chin","year":"2019","unstructured":"Chin TY, Chou H, Peh WCG. The acutely injured elbow. Radiol Clin North Am. 2019;57:911\u201330.","journal-title":"Radiol Clin North Am"},{"key":"9161_CR3","doi-asserted-by":"publisher","first-page":"137","DOI":"10.5435\/00124635-200903000-00003","volume":"17","author":"PK Mathew","year":"2009","unstructured":"Mathew PK, Athwal GS, King GJW. Terrible triad injury of the elbow: current concepts. J Am Acad Orthop Surg. 2009;17:137\u201351.","journal-title":"J Am Acad Orthop Surg"},{"key":"9161_CR4","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1097\/BOT.0000000000001425","volume":"33","author":"S-W Jung","year":"2019","unstructured":"Jung S-W, Kim D-H, Kang S-H, Eho Y-J, Yang S-W, Lee G-E. Risk factors that influence subsequent recurrent instability in terrible triad injury of the elbow. J Orthop Trauma. 2019;33:250\u20135.","journal-title":"J Orthop Trauma"},{"key":"9161_CR5","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1148\/rg.2017160130","volume":"37","author":"BJ Erickson","year":"2017","unstructured":"Erickson BJ, Korfiatis P, Akkus Z, Kline TL. Machine learning for medical imaging. Radiographics. 2017;37:505\u201315.","journal-title":"Radiographics"},{"key":"9161_CR6","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1016\/j.crad.2017.11.015","volume":"73","author":"DH Kim","year":"2018","unstructured":"Kim DH, MacKinnon T. Artificial intelligence in fracture detection: transfer learning from deep convolutional neural networks. Clin Radiol. 2018;73:439\u201345.","journal-title":"Clin Radiol"},{"key":"9161_CR7","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1080\/17453674.2017.1344459","volume":"88","author":"J Olczak","year":"2017","unstructured":"Olczak J, Fahlberg N, Maki A, Razavian AS, Jilert A, Stark A, et al. Artificial intelligence for analyzing orthopedic trauma radiographs. Acta Orthop. 2017;88:581\u20136.","journal-title":"Acta Orthop"},{"key":"9161_CR8","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1080\/17453674.2019.1600125","volume":"90","author":"K Gan","year":"2019","unstructured":"Gan K, Xu D, Lin Y, Shen Y, Zhang T, Hu K, et al. Artificial intelligence detection of distal radius fractures: a comparison between the convolutional neural network and professional assessments. Acta Orthop. 2019;90:394\u2013400.","journal-title":"Acta Orthop"},{"key":"9161_CR9","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1080\/17453674.2018.1453714","volume":"89","author":"SW Chung","year":"2018","unstructured":"Chung SW, Han SS, Lee JW, Oh K-S, Kim NR, Yoon JP, et al. Automated detection and classification of the proximal humerus fracture by using deep learning algorithm. Acta Orthop. 2018;89:468\u201373.","journal-title":"Acta Orthop"},{"key":"9161_CR10","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1097\/RLI.0000000000000615","volume":"55","author":"JW Choi","year":"2020","unstructured":"Choi JW, Cho YJ, Lee S, Lee J, Lee S, Choi YH, et al. Using a dual-input convolutional neural network for automated detection of pediatric supracondylar fracture on conventional radiography. Invest Radiol. 2020;55:101\u201310.","journal-title":"Invest Radiol"},{"key":"9161_CR11","doi-asserted-by":"publisher","first-page":"2482","DOI":"10.1097\/CORR.0000000000000848","volume":"477","author":"DWG Langerhuizen","year":"2019","unstructured":"Langerhuizen DWG, Janssen SJ, Mallee WH, van den Bekerom MPJ, Ring D, Kerkhoffs GMMJ, et al. What are the applications and limitations of artificial intelligence for fracture detection and classification in orthopaedic trauma imaging?? A systematic review. Clin Orthop Relat Res. 2019;477:2482\u201391.","journal-title":"Clin Orthop Relat Res"},{"key":"9161_CR12","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1080\/17453674.2020.1837420","volume":"92","author":"J Olczak","year":"2021","unstructured":"Olczak J, Emilson F, Razavian A, Antonsson T, Stark A, Gordon M. Ankle fracture classification using deep learning: automating detailed AO foundation\/orthopedic trauma association (AO\/OTA) 2018 malleolar fracture identification reaches a high degree of correct classification. Acta Orthop. 2021;92:102\u20138.","journal-title":"Acta Orthop"},{"key":"9161_CR13","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.cmpb.2019.02.006","volume":"171","author":"YD Pranata","year":"2019","unstructured":"Pranata YD, Wang K-C, Wang J-C, Idram I, Lai J-Y, Liu J-W, et al. Deep learning and SURF for automated classification and detection of calcaneus fractures in CT images. Comput Methods Programs Biomed. 2019;171:27\u201337.","journal-title":"Comput Methods Programs Biomed"},{"key":"9161_CR14","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000001063","author":"EG Meinberg","year":"2018","unstructured":"Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and dislocation classification compendium\u20142018. J Orthop Trauma. 2018. https:\/\/doi.org\/10.1097\/BOT.0000000000001063.","journal-title":"J Orthop Trauma"},{"key":"9161_CR15","unstructured":"Sundararajan Mukund T, Qiqi Y. Axiomatic Attribution for Deep Networks. Sydney, Australia; 2017. pp. 3319\u201328."},{"key":"9161_CR16","unstructured":"Athiwaratkun B, Finzi M, Izmailov P, Wilson AG. There are many consistent explanations of unlabeled data. Why You Should Average; 2019."},{"key":"9161_CR17","doi-asserted-by":"publisher","first-page":"e0248809","DOI":"10.1371\/journal.pone.0248809","volume":"16","author":"A Lind","year":"2021","unstructured":"Lind A, Akbarian E, Olsson S, N\u00e5sell H, Sk\u00f6ldenberg O, Razavian AS, et al. Artificial intelligence for the classification of fractures around the knee in adults according to the 2018 AO\/OTA classification system. PLoS One. 2021;16:e0248809.","journal-title":"PLoS One"},{"key":"9161_CR18","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1097\/JTO.0b013e3181ec173d","volume":"5","author":"JN Mandrekar","year":"2010","unstructured":"Mandrekar JN. Receiver operating characteristic curve in diagnostic test assessment. J Thorac Oncol. 2010;5:1315\u20136.","journal-title":"J Thorac Oncol"},{"key":"9161_CR19","unstructured":"LI F, HE H. Assessing the accuracy of diagnostic tests. Shanghai Arch Psychiatry. 2018;30:207\u201312."},{"key":"9161_CR20","first-page":"627","volume":"4","author":"K Hajian-Tilaki","year":"2013","unstructured":"Hajian-Tilaki K. Receiver operating characteristic (ROC) curve analysis for medical diagnostic test evaluation. Casp J Intern Med. 2013;4:627\u201335.","journal-title":"Casp J Intern Med"},{"key":"9161_CR21","doi-asserted-by":"publisher","first-page":"11591","DOI":"10.1073\/pnas.1806905115","volume":"115","author":"R Lindsey","year":"2018","unstructured":"Lindsey R, Daluiski A, Chopra S, Lachapelle A, Mozer M, Sicular S, et al. Deep neural network improves fracture detection by clinicians. Proc Natl Acad Sci U S A. 2018;115:11591\u20136.","journal-title":"Proc Natl Acad Sci U S A"},{"key":"9161_CR22","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s00256-018-3016-3","volume":"48","author":"T Urakawa","year":"2019","unstructured":"Urakawa T, Tanaka Y, Goto S, Matsuzawa H, Watanabe K, Endo N. Detecting intertrochanteric hip fractures with orthopedist-level accuracy using a deep convolutional neural network. Skeletal Radiol. 2019;48:239\u201344.","journal-title":"Skeletal Radiol"},{"key":"9161_CR23","volume-title":"Detecting hip fractures with radiologist-level performance using deep neural networks","author":"W Gale","year":"2017","unstructured":"Gale W, Oakden-Rayner L, Carneiro G, Bradley AP, Palmer LJ. Detecting hip fractures with radiologist-level performance using deep neural networks. stat]: arXiv:171106504 [cs; 2017."},{"key":"9161_CR24","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1302\/2633-1462.210.BJO-2021-0133","volume":"2","author":"L Oliveira e Carmo","year":"2021","unstructured":"Oliveira e Carmo L, van den Merkhof A, Olczak J, Gordon M, Jutte PC, Jaarsma RL, et al. An increasing number of convolutional neural networks for fracture recognition and classification in orthopaedics. Bone Joint Open. 2021;2:879\u201385.","journal-title":"Bone Joint Open"},{"key":"9161_CR25","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/1471-227X-6-4","volume":"6","author":"P Hallas","year":"2006","unstructured":"Hallas P, Ellingsen T. Errors in fracture diagnoses in the emergency department\u2013characteristics of patients and diurnal variation. BMC Emerg Med. 2006;6:4.","journal-title":"BMC Emerg Med"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-09161-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-025-09161-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-025-09161-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T06:46:12Z","timestamp":1757400372000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-025-09161-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,9]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["9161"],"URL":"https:\/\/doi.org\/10.1186\/s12891-025-09161-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,9]]},"assertion":[{"value":"11 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Swedish Ethical Review Authority (2014\/453\u2009\u2212\u200931). The study adhered to the principals laid out by the Helsinki declaration.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent to participate was not applicable due to the data analysis being performed on anonymized data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"848"}}