{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T15:39:58Z","timestamp":1774021198151,"version":"3.50.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T00:00:00Z","timestamp":1770940800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T00:00:00Z","timestamp":1773964800000},"content-version":"vor","delay-in-days":35,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-026-09615-1","type":"journal-article","created":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T05:04:18Z","timestamp":1770959058000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical comparison of a novel hockey-stick locking plate with a pes anserinus sparing design for Schatzker IV tibial plateau fractures"],"prefix":"10.1186","volume":"27","author":[{"given":"Xiao","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Dong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gadisa Musa","family":"Wako","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junwei","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bin","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,2,13]]},"reference":[{"key":"9615_CR1","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.21037\/atm-22-4529","volume":"10","author":"S Gao","year":"2022","unstructured":"Gao S, Yao QC, Geng L, Lu J, Li M, An K, et al. A finite element analysis of the supportive effect of a new type of rotary support plate on lateral tibial plateau fractures. Ann Transl Med. 2022;10:1020\u20131020. https:\/\/doi.org\/10.21037\/atm-22-4529.","journal-title":"Ann Transl Med"},{"key":"9615_CR2","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1055\/s-0032-1324807","volume":"26","author":"A Urruela","year":"2012","unstructured":"Urruela A, Davidovitch R, Karia R, Khurana S, Egol K. Results following operative treatment of tibial plateau fractures. J Knee Surg. 2012;26:161\u20136. https:\/\/doi.org\/10.1055\/s-0032-1324807.","journal-title":"J Knee Surg"},{"key":"9615_CR3","doi-asserted-by":"publisher","first-page":"1944","DOI":"10.1016\/j.injury.2021.04.013","volume":"52","author":"LS Marchand","year":"2021","unstructured":"Marchand LS, McAlister IP, Shannon SS, Nascone JW, O\u2019Toole RV, Jaeblon T. Medial sided articular impaction in tibial plateau fractures. Injury. 2021;52:1944\u201350. https:\/\/doi.org\/10.1016\/j.injury.2021.04.013.","journal-title":"Injury"},{"key":"9615_CR4","doi-asserted-by":"publisher","unstructured":"Vogel M, Hoffman A, Revak T. Schatzker IV tibial plateau fractures: are they always unicondylar? OTA Int. 2024;7. https:\/\/doi.org\/10.1097\/oi9.0000000000000341.","DOI":"10.1097\/oi9.0000000000000341"},{"key":"9615_CR5","doi-asserted-by":"publisher","unstructured":"Cao F, Xue H, Yan C, Lin Z, Mi B, Panayi AC et al. Clinical Application Study of Minimally Invasive Double-Reverse Traction in Complex Tibial Plateau Fractures. Biomed Res Int. 2022;2022. https:\/\/doi.org\/10.1155\/2022\/5564604","DOI":"10.1155\/2022\/5564604"},{"key":"9615_CR6","doi-asserted-by":"publisher","unstructured":"Thamyongkit S, Abbasi P, Parks BG, Shafiq B, Hasenboehler EA. Weightbearing after combined medial and lateral plate fixation of AO\/OTA 41-C2 bicondylar tibial plateau fractures: a Biomechanical study. BMC Musculoskelet Disord. 2022;23. https:\/\/doi.org\/10.1186\/s12891-022-05024-2.","DOI":"10.1186\/s12891-022-05024-2"},{"key":"9615_CR7","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.injury.2005.06.035","volume":"37","author":"PJ Papagelopoulos","year":"2005","unstructured":"Papagelopoulos PJ, Partsinevelos AA, Themistocleous GS, Mavrogenis AF, Korres DS, Soucacos PN. Complications after tibia plateau fracture surgery. Injury. 2005;37:475\u201384. https:\/\/doi.org\/10.1016\/j.injury.2005.06.035.","journal-title":"Injury"},{"key":"9615_CR8","doi-asserted-by":"publisher","first-page":"2129","DOI":"10.1007\/s00264-016-3157-8","volume":"40","author":"H Chang","year":"2016","unstructured":"Chang H, Zhu Y, Zheng Z, Chen W, Zhao S, Zhang Y, et al. Meta-analysis shows that highly comminuted bicondylar tibial plateau fractures treated by single lateral locking plate give similar outcomes as dual plate fixation. Int Orthop. 2016;40:2129\u201341. https:\/\/doi.org\/10.1007\/s00264-016-3157-8.","journal-title":"Int Orthop"},{"key":"9615_CR9","doi-asserted-by":"publisher","unstructured":"Forna N, Munteanu F, Moldoveanu S, Savin L, S\u00eerbu P, Puha B. Treatment of C1.1 (AO-41) tibial plateau fracture: A finite element analysis of single medial, lateral and dual plating. Exp Ther Med. 2022;23. https:\/\/doi.org\/10.3892\/etm.2022.11121.","DOI":"10.3892\/etm.2022.11121"},{"key":"9615_CR10","doi-asserted-by":"publisher","unstructured":"\u00c7a\u011flar C, Akcaalan S, \u00d6zaslan H\u0130, Bozer M, Emre F, U\u011furlu M. Comparative analysis of single lateral locked plate and double locked plate application in the treatment of bicondylar tibial plateau fractures. Cur\u0113us. 2021;13. https:\/\/doi.org\/10.7759\/cureus.19298.","DOI":"10.7759\/cureus.19298"},{"key":"9615_CR11","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1016\/j.injury.2011.03.041","volume":"42","author":"P Potocnik","year":"2011","unstructured":"Potocnik P, Acklin YP, Sommer C. Operative strategy in postero-medial fracture-dislocation of the proximal tibia. Injury. 2011;42:1060\u20135. https:\/\/doi.org\/10.1016\/j.injury.2011.03.041.","journal-title":"Injury"},{"key":"9615_CR12","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.injury.2013.11.028","volume":"45","author":"R Berber","year":"2013","unstructured":"Berber R, Lewis CP, Copas D, Forward DP, Moran CG. Postero-medial approach for complex tibial plateau injuries with a postero-medial or postero-lateral shear fragment. Injury. 2013;45:757\u201365. https:\/\/doi.org\/10.1016\/j.injury.2013.11.028.","journal-title":"Injury"},{"key":"9615_CR13","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1186\/s13018-025-05761-9","volume":"20","author":"X Wang","year":"2025","unstructured":"Wang X, Zhu Z, Yin Z, Xu H, Jiang D, Xiu H, et al. Early outcomes of modified hockey-stick medial plate in the treatment of Schatzker IV-VI tibial plateau fractures: a retrospective controlled study. J Orthop Surg Res. 2025;20:345. https:\/\/doi.org\/10.1186\/s13018-025-05761-9.","journal-title":"J Orthop Surg Res"},{"key":"9615_CR14","doi-asserted-by":"publisher","first-page":"111158","DOI":"10.1016\/j.injury.2023.111158","volume":"55","author":"J Ando","year":"2023","unstructured":"Ando J, Takahashi T, Matsumura T, Nibe Y, Takeshita K. Biomechanical comparisons of plate placement for medial tibial plateau fractures (Schatzker type IV): A Biomechanical study using Porcine tibias. Injury. 2023;55:111158\u2013111158. https:\/\/doi.org\/10.1016\/j.injury.2023.111158.","journal-title":"Injury"},{"key":"9615_CR15","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1051\/sicotj\/2025008","volume":"11","author":"S Hiyama","year":"2025","unstructured":"Hiyama S, Takahashi T, Ando J, Nibe Y, Matsumura T, Takeshita K. Impact of screw reinsertion on osteosynthesis stability in Schatzker IV tibial plateau fractures: a Biomechanical study. SICOT J. 2025;11:11\u201311. https:\/\/doi.org\/10.1051\/sicotj\/2025008.","journal-title":"SICOT J"},{"key":"9615_CR16","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1016\/j.otsr.2009.11.016","volume":"96","author":"H Cift","year":"2010","unstructured":"Cift H, Cetik O, Kalaycioglu B, Dirikoglu MH, Ozkan K, Eksioglu F. Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study. Orthop Traumatol Surg Res. 2010;96:263\u20137. https:\/\/doi.org\/10.1016\/j.otsr.2009.11.016.","journal-title":"Orthop Traumatol Surg Res"},{"key":"9615_CR17","doi-asserted-by":"publisher","first-page":"22439","DOI":"10.1364\/oe.27.022439","volume":"27","author":"Y Su","year":"2019","unstructured":"Su Y, Gao Z, Fang Z, Liu Y, Wang Y, Zhang Q, et al. Theoretical analysis on performance of digital speckle pattern: uniqueness, accuracy, precision, and Spatial resolution. Opt Express. 2019;27:22439. https:\/\/doi.org\/10.1364\/oe.27.022439.","journal-title":"Opt Express"},{"key":"9615_CR18","doi-asserted-by":"publisher","first-page":"e129","DOI":"10.1097\/bot.0000000000002257","volume":"36","author":"S Samsami","year":"2021","unstructured":"Samsami S, P\u00e4tzold R, Neuy T, Greinwald M, M\u00fcller PE, Chevalier Y, et al. Biomechanical comparison of 2 double plating methods in a coronal fracture model of bicondylar tibial plateau fractures. J Orthop Trauma. 2021;36:e129\u201335. https:\/\/doi.org\/10.1097\/bot.0000000000002257.","journal-title":"J Orthop Trauma"},{"key":"9615_CR19","doi-asserted-by":"publisher","first-page":"1719","DOI":"10.1007\/s00402-020-03412-8","volume":"140","author":"S Samsami","year":"2020","unstructured":"Samsami S, P\u00e4tzold R, Winkler M, Herrmann S, Augat P. The effect of coronal splits on the structural stability of bi-condylar tibial plateau fractures: a Biomechanical investigation. Arch Orthop Trauma Surg. 2020;140:1719\u201330. https:\/\/doi.org\/10.1007\/s00402-020-03412-8.","journal-title":"Arch Orthop Trauma Surg"},{"key":"9615_CR20","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1111\/os.12205","volume":"7","author":"P Wang","year":"2015","unstructured":"Wang P, Ren D, Zhou B. Surgical technique of anterolateral approach for tibial plateau fracture. Orthop Surg. 2015;7:368\u201370. https:\/\/doi.org\/10.1111\/os.12205.","journal-title":"Orthop Surg"},{"key":"9615_CR21","doi-asserted-by":"publisher","unstructured":"Ozkaya U, Parmaksizoglu AS. Dual locked plating of unstable bicondylar tibial plateau fractures. Injury. 2015;46 Supplement 2:S9\u201313. https:\/\/doi.org\/10.1016\/j.injury.2015.05.025.","DOI":"10.1016\/j.injury.2015.05.025"},{"key":"9615_CR22","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1186\/s13018-023-04397-x","volume":"18","author":"Z Hu","year":"2023","unstructured":"Hu Z, Ren W, Zhang W, Li L, Xu W. Potential problem and solution of lateral plate postposition for the posterolateral tibial plateau fracture. J Orthop Surg Res. 2023;18:984. https:\/\/doi.org\/10.1186\/s13018-023-04397-x.","journal-title":"J Orthop Surg Res"},{"key":"9615_CR23","doi-asserted-by":"publisher","first-page":"4739","DOI":"10.3390\/app12094739","volume":"12","author":"AD Castro-Franco","year":"2022","unstructured":"Castro-Franco AD, Mendoza-Mu\u00f1oz I, Gonz\u00e1lez-Angeles A, Montoya-Reyes MI, Pital\u00faa-D\u00edaz N. Optimization of locking plate screw angle used to treat Two-Part proximal humerus fractures to maintain fracture stability. Appl Sci. 2022;12:4739. https:\/\/doi.org\/10.3390\/app12094739.","journal-title":"Appl Sci"},{"key":"9615_CR24","doi-asserted-by":"publisher","DOI":"10.2106\/jbjs.23.00480","author":"D Kim","year":"2024","unstructured":"Kim D, Lim J-R, Yoon T-H, Shin S-H, Chun Y-M. Lateral wall integrity of the greater tuberosity is important for the stability of osteoporotic proximal humeral fractures after plate fixation. J Bone Joint Surg. 2024. https:\/\/doi.org\/10.2106\/jbjs.23.00480.","journal-title":"J Bone Joint Surg"},{"key":"9615_CR25","doi-asserted-by":"publisher","unstructured":"Chiu Y-C, Hsu C-E, Ho T-Y, Ting Y-N, Tsai M-T, Hsu J-T. Bone plate fixation ability on the dorsal and lateral sides of a metacarpal shaft transverse fracture. J Orthop Surg Res. 2021;16. https:\/\/doi.org\/10.1186\/s13018-021-02575-3.","DOI":"10.1186\/s13018-021-02575-3"},{"key":"9615_CR26","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620x.84b8.13752","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren SM. Evolution of the internal fixation of long bone fractures: the scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84:1093\u2013110. https:\/\/doi.org\/10.1302\/0301-620x.84b8.13752.","journal-title":"J Bone Joint Surg Br"},{"key":"9615_CR27","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.injury.2020.06.044","volume":"52","author":"AL Foster","year":"2020","unstructured":"Foster AL, Moriarty TF, Zalavras C, Morgenstern M, Jaiprakash A, Crawford R, et al. The influence of Biomechanical stability on bone healing and fracture-related infection: the legacy of Stephan Perren. Injury. 2020;52:43\u201352. https:\/\/doi.org\/10.1016\/j.injury.2020.06.044.","journal-title":"Injury"},{"key":"9615_CR28","doi-asserted-by":"publisher","unstructured":"Zhao X, Jing W, Yun Z, Tong X, Li Z, Yu J, et al. RETRACTED ARTICLE: an experimental study on stress-shielding effects of locked compression plates in fixing intact dog femur. J Orthop Surg Res. 2021;16. https:\/\/doi.org\/10.1186\/s13018-021-02238-3.","DOI":"10.1186\/s13018-021-02238-3"},{"key":"9615_CR29","doi-asserted-by":"publisher","first-page":"105768","DOI":"10.1016\/j.clinbiomech.2022.105768","volume":"99","author":"I Kaymaz","year":"2022","unstructured":"Kaymaz I, Murat F, Korkmaz \u0130H, Yavuz O. A new design for the humerus fixation plate using a novel reliability-based topology optimization approach to mitigate the stress shielding effect. Clin Biomech (Bristol). 2022;99:105768. https:\/\/doi.org\/10.1016\/j.clinbiomech.2022.105768.","journal-title":"Clin Biomech (Bristol)"},{"key":"9615_CR30","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.actbio.2023.11.011","volume":"173","author":"A Chmielewska","year":"2023","unstructured":"Chmielewska A, Dean D. The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure. Acta Biomater. 2023;173:51\u201365. https:\/\/doi.org\/10.1016\/j.actbio.2023.11.011.","journal-title":"Acta Biomater"},{"key":"9615_CR31","doi-asserted-by":"publisher","first-page":"106356","DOI":"10.1016\/j.jmbbm.2023.106356","volume":"151","author":"T Yuling","year":"2023","unstructured":"Yuling T, Xiao C, Junxia Z, Jun J, Xinghua L. Effect of different composite plates on the healing of femoral fractures. J Mech Behav Biomed Mater. 2023;151:106356. https:\/\/doi.org\/10.1016\/j.jmbbm.2023.106356.","journal-title":"J Mech Behav Biomed Mater"},{"key":"9615_CR32","doi-asserted-by":"publisher","first-page":"2207","DOI":"10.1016\/j.injury.2022.04.006","volume":"53","author":"J Schatzker","year":"2022","unstructured":"Schatzker J, Kfuri M. Revisiting the management of tibial plateau fractures. Injury. 2022;53:2207\u201318. https:\/\/doi.org\/10.1016\/j.injury.2022.04.006.","journal-title":"Injury"},{"key":"9615_CR33","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.jot.2018.01.001","volume":"13","author":"X He","year":"2018","unstructured":"He X, Cai H, Zhang K. Pie-crusting technique is effective and safe to release superficial medial collateral ligament for total knee arthroplasty. J Orthop Translat. 2018;13:33\u201340. https:\/\/doi.org\/10.1016\/j.jot.2018.01.001.","journal-title":"J Orthop Translat"},{"key":"9615_CR34","first-page":"145","volume":"44 2","author":"AT Chen","year":"2024","unstructured":"Chen AT, Askam BM, Hwang JS, Karunakar M, Hsu JR. Do percutaneously applied medial proximal tibia plates need to go beneath the Pes tendons? Iowa Orthop J. 2024;44 2:145\u20138.","journal-title":"Iowa Orthop J"},{"key":"9615_CR35","doi-asserted-by":"publisher","first-page":"e69","DOI":"10.1016\/j.eats.2021.09.002","volume":"11","author":"R Nakamura","year":"2021","unstructured":"Nakamura R, Kuroda K, Takahashi M, Katsuki Y. Open wedge high tibial osteotomy with Pes Anserinus preservation and insertion of bone substitutes. Arthrosc Tech. 2021;11:e69\u201378. https:\/\/doi.org\/10.1016\/j.eats.2021.09.002.","journal-title":"Arthrosc Tech"},{"key":"9615_CR36","doi-asserted-by":"publisher","first-page":"170","DOI":"10.7507\/1002-1892.202104066","volume":"36","author":"X Zhang","year":"2022","unstructured":"Zhang X, Ci W, Yan S, Luo K, Yan S, Zhang Q, et al. [Open reduction and internal fixation with plate via posteromedial approach of retaining Pes Anserinus tendon in the treatment of tibial plateau fracture]. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2022;36:170\u20136. https:\/\/doi.org\/10.7507\/1002-1892.202104066.","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"},{"key":"9615_CR37","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1055\/s-0042-1750835","volume":"58","author":"K Y\u0131ld\u0131r\u0131m","year":"2022","unstructured":"Y\u0131ld\u0131r\u0131m K, Beyzadeo\u011flu T. Removal rate of the Tomofix \u00ae system after high tibial osteotomy is higher than reported. Revista Brasileira De Ortop. 2022;58:326\u201330. https:\/\/doi.org\/10.1055\/s-0042-1750835.","journal-title":"Revista Brasileira De Ortop"},{"key":"9615_CR38","doi-asserted-by":"publisher","first-page":"2000","DOI":"10.2106\/jbjs.f.01176","volume":"89","author":"RF LaPrade","year":"2007","unstructured":"LaPrade RF, Engebretsen AH, Ly TV, Johansen S, Wentorf FA, Engebretsen L. The anatomy of the medial part of the knee. J Bone Joint Surg. 2007;89:2000\u201310. https:\/\/doi.org\/10.2106\/jbjs.f.01176.","journal-title":"J Bone Joint Surg"},{"key":"9615_CR39","doi-asserted-by":"publisher","first-page":"2326","DOI":"10.1016\/j.injury.2016.07.004","volume":"47","author":"P Zhang","year":"2016","unstructured":"Zhang P, Lian K, Luo D, Huang Z, Li T, Lin D. A combined approach for the treatment of lateral and posterolateral tibial plateau fractures. Injury. 2016;47:2326\u201330. https:\/\/doi.org\/10.1016\/j.injury.2016.07.004.","journal-title":"Injury"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-026-09615-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-09615-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-09615-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,20]],"date-time":"2026-03-20T14:38:28Z","timestamp":1774017508000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-026-09615-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,13]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9615"],"URL":"https:\/\/doi.org\/10.1186\/s12891-026-09615-1","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,13]]},"assertion":[{"value":"27 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study did not involve any human participants or animal experiments; therefore, approval from an institutional ethics committee and informed consent were not required.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"226"}}