{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:30:45Z","timestamp":1787020245387,"version":"build-2736575974"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:00:00Z","timestamp":1787011200000},"content-version":"vor","delay-in-days":97,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Institutional Project (Category I) of the General Hospital of Southern Theater Command, PLA","award":["No.2022035"],"award-info":[{"award-number":["No.2022035"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-026-09916-5","type":"journal-article","created":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T10:38:26Z","timestamp":1778668706000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical study of medial buttress plate combined with cannulated compression screws for pauwels type III femoral neck fractures using formalin-fixed human cadaveric femora"],"prefix":"10.1186","volume":"27","author":[{"given":"Yeqiang","family":"Luo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianmo","family":"Bai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingyi","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shanghui","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baofeng","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,13]]},"reference":[{"key":"9916_CR1","unstructured":"Zhang CQ, Zhang YZ, Yu B, Zhang W, Sun H. Diagnosis and Treatment Guidelines for Adult Femoral Neck Fractures. Chin J Orthop Traumatol. 2018;11."},{"issue":"7","key":"9916_CR2","doi-asserted-by":"publisher","first-page":"e302","DOI":"10.5435\/JAAOS-D-23-00720","volume":"32","author":"RA Rajfer","year":"2024","unstructured":"Rajfer RA, Carlson BA, Johnson JP. High-energy Femoral Neck Fractures in Young Patients. J Am Acad Orthop Surg. 2024;32(7):e302\u201312.","journal-title":"J Am Acad Orthop Surg"},{"issue":"8","key":"9916_CR3","doi-asserted-by":"publisher","first-page":"e24834","DOI":"10.1097\/MD.0000000000024834","volume":"100","author":"J-G Wang","year":"2021","unstructured":"Wang J-G, Wu J-X, Li Y-M, Xu Y-Y. Biomechanical analysis of the closed reduction internal fixation with cannulated screw of femoral neck fractures. Med (Baltim). 2021;100(8):e24834.","journal-title":"Med (Baltim)"},{"issue":"1","key":"9916_CR4","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1186\/s13018-023-04114-8","volume":"18","author":"N Ramadanov","year":"2023","unstructured":"Ramadanov N, J\u00f3\u017awiak K, Hauptmann M, Lazaru P, Marinova-Kichikova P, Dimitrov D, Becker R. Cannulated screws versus dynamic hip screw versus hemiarthroplasty versus total hip arthroplasty in patients with displaced and non-displaced femoral neck fractures: a systematic review and frequentist network meta-analysis of 5703 patients. J Orthop Surg Res. 2023;18(1):625.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"9916_CR5","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1186\/s12891-023-06378-x","volume":"24","author":"J Jiang","year":"2023","unstructured":"Jiang J, Chen J, Xing F, Liu H, Xiang Z. Comparison of femoral neck system versus cannulated screws for treatment of femoral neck fractures: a systematic review and meta-analysis. BMC Musculoskelet Disord. 2023;24(1):285.","journal-title":"BMC Musculoskelet Disord"},{"issue":"2","key":"9916_CR6","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1016\/j.injury.2021.10.029","volume":"53","author":"R-Y Zhang","year":"2022","unstructured":"Zhang R-Y, Li J-T, Zhao J-X, Zhao Z, Zhang L-C, Yun C, Su X-Y, Tang P-F. Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis. Injury. 2022;53(2):353\u201361.","journal-title":"Injury"},{"key":"9916_CR7","doi-asserted-by":"publisher","first-page":"106060","DOI":"10.1016\/j.clinbiomech.2023.106060","volume":"108","author":"Z Zhong","year":"2023","unstructured":"Zhong Z, Lan X, Xiang Z, Duan X. Femoral neck system and cannulated compression screws in the treatment of non-anatomical reduction Pauwels type-III femoral neck fractures: A finite element analysis. Clin Biomech (Bristol). 2023;108:106060.","journal-title":"Clin Biomech (Bristol)"},{"issue":"2","key":"9916_CR8","doi-asserted-by":"publisher","first-page":"112160","DOI":"10.1016\/j.injury.2025.112160","volume":"56","author":"L McGarry","year":"2025","unstructured":"McGarry L, Rotaru J, Gunaratne R, Hickey I. Medial buttress plate use in neck of femur fracture fixations: A systematic review. Injury. 2025;56(2):112160.","journal-title":"Injury"},{"issue":"5","key":"9916_CR9","doi-asserted-by":"publisher","first-page":"4011","DOI":"10.1007\/s00068-022-01931-0","volume":"48","author":"S Lin","year":"2022","unstructured":"Lin S, Li J, Wang R, Ou Y, Jia Z, Zhang Y, Xia H, Li B, Chen B. The effect of anteromedial support plate with three cannulated screws in the treatment of Pauwels type III femoral neck fracture in young adults. Eur J Trauma Emerg Surg. 2022;48(5):4011\u20137.","journal-title":"Eur J Trauma Emerg Surg"},{"key":"9916_CR10","unstructured":"Lin SH. Finite Element Analysis of the Treatment of Pauwels Type III Femoral Neck Fracture with Improved Femoral Neck Medial Support Plate Combined with Hollow Screw. Southern Medical University; 2023."},{"issue":"10","key":"9916_CR11","doi-asserted-by":"publisher","first-page":"3124","DOI":"10.1016\/j.injury.2022.06.029","volume":"53","author":"C Yildirim","year":"2022","unstructured":"Yildirim C, Demirel M, Karahan G, Cetinkaya E, Misir A, Yamak F, Bozda\u011f E. Biomechanical comparison of four different fixation methods in the management of Pauwels type III femoral neck fractures: Is there a clear winner? Injury. 2022;53(10):3124\u20139.","journal-title":"Injury"},{"issue":"5","key":"9916_CR12","doi-asserted-by":"publisher","first-page":"243","DOI":"10.5152\/j.aott.2023.22127","volume":"57","author":"F K\u0131l\u0131\u00e7","year":"2023","unstructured":"K\u0131l\u0131\u00e7 F, Polat A, Yamak F, Bozdag E, Fidan F, Ba\u015far H. Biomechanical comparison of fixation methods on third-generation femoral composite bone models in Pauwels type 3 femoral neck fractures: Contribution of the medial buttress plate to fixation. Acta Orthop Traumatol Turc. 2023;57(5):243\u20139.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"1","key":"9916_CR13","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1186\/s12891-022-05056-8","volume":"23","author":"C Ma","year":"2022","unstructured":"Ma C, Liu Y, Liu J, Chen L, Huang J, Luo X, Xie Z. The role of the medial buttress plate in the treatment of Pauwels type II and III femoral neck fracture in nonelderly patients: a retrospective study and preliminary results. BMC Musculoskelet Disord. 2022;23(1):100.","journal-title":"BMC Musculoskelet Disord"},{"issue":"1","key":"9916_CR14","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.clinbiomech.2008.07.004","volume":"24","author":"M Windolf","year":"2009","unstructured":"Windolf M, Braunstein V, Dutoit C, Schwieger K. Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol). 2009;24(1):59\u201364.","journal-title":"Clin Biomech (Bristol)"},{"issue":"8","key":"9916_CR15","doi-asserted-by":"publisher","first-page":"515","DOI":"10.5435\/JAAOS-D-15-00237","volume":"24","author":"MA Seeley","year":"2016","unstructured":"Seeley MA, Georgiadis AG, Sankar WN. Hip Vascularity: A Review of the Anatomy and Clinical Implications. J Am Acad Orthop Surg. 2016;24(8):515\u201326.","journal-title":"J Am Acad Orthop Surg"},{"issue":"1","key":"9916_CR16","doi-asserted-by":"publisher","first-page":"39","DOI":"10.2106\/00004623-200701000-00006","volume":"89","author":"P Tornetta","year":"2007","unstructured":"Tornetta P, Kain MSH, Creevy WR. Diagnosis of femoral neck fractures in patients with a femoral shaft fracture. Improvement with a standard protocol. J Bone Joint Surg Am. 2007;89(1):39\u201343.","journal-title":"J Bone Joint Surg Am"},{"issue":"8","key":"9916_CR17","doi-asserted-by":"publisher","first-page":"2390","DOI":"10.1016\/j.injury.2021.05.009","volume":"52","author":"NB Rogers","year":"2021","unstructured":"Rogers NB, Achor TS, Kumaravel M, Gary JL, Munz JW, Choo AM, Routt ML, Warner SJ. Implementation of a novel MRI protocol for diagnosing femoral neck fractures in high energy femoral shaft fractures: One year results. Injury. 2021;52(8):2390\u20134.","journal-title":"Injury"},{"issue":"3","key":"9916_CR18","doi-asserted-by":"publisher","first-page":"708","DOI":"10.1016\/j.injury.2018.11.020","volume":"50","author":"JP Johnson","year":"2019","unstructured":"Johnson JP, Kleiner J, Goodman AD, Gil JA, Daniels AH, Hayda RA. Treatment of femoral neck fractures in patients 45\u201364 years of age. Injury. 2019;50(3):708\u201312.","journal-title":"Injury"},{"issue":"6","key":"9916_CR19","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1097\/BOT.0000000000002355","volume":"36","author":"CA Collinge","year":"2022","unstructured":"Collinge CA, Finlay A, Rodriguez-Buitrago A, Beltran MJ, Mitchell PM, Mir HR, Gardner MJ, Archdeacon MT, Tornetta P. Treatment Failure in Femoral Neck Fractures in Adults Less Than 50 Years of Age: Analysis of 492 Patients Repaired at 26 North American Trauma Centers. J Orthop Trauma. 2022;36(6):271\u20139.","journal-title":"J Orthop Trauma"},{"key":"9916_CR20","doi-asserted-by":"publisher","first-page":"215145931985913","DOI":"10.1177\/2151459319859139","volume":"10","author":"Y Lu","year":"2019","unstructured":"Lu Y, Uppal HS. Hip Fractures: Relevant Anatomy, Classification, and Biomechanics of Fracture and Fixation. Geriatr Orthop Surg Rehabil. 2019;10:2151459319859139.","journal-title":"Geriatr Orthop Surg Rehabil"},{"issue":"1","key":"9916_CR21","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1186\/s12891-022-05307-8","volume":"23","author":"L Qiu","year":"2022","unstructured":"Qiu L, Huang Y, Li G, Wu H, Zhang Y, Zhang Z. Essential role of reliable reduction quality in internal fixation of femoral neck fractures in the non-elderly patients-a propensity score matching analysis. BMC Musculoskelet Disord. 2022;23(1):346.","journal-title":"BMC Musculoskelet Disord"},{"issue":"Suppl 1","key":"9916_CR22","doi-asserted-by":"publisher","first-page":"S12","DOI":"10.1097\/BOT.0000000000001370","volume":"33","author":"J Halvorson","year":"2019","unstructured":"Halvorson J. Reduction Techniques for Young Femoral Neck Fractures. J Orthop Trauma. 2019;33(Suppl 1):S12\u20139.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"9916_CR23","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.injury.2014.10.011","volume":"46","author":"P Ghayoumi","year":"2015","unstructured":"Ghayoumi P, Kandemir U, Morshed S. Evidence based update: open versus closed reduction. Injury. 2015;46(3):467\u201373.","journal-title":"Injury"},{"issue":"1","key":"9916_CR24","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1097\/BOT.0b013e318214f321","volume":"26","author":"YA Weil","year":"2012","unstructured":"Weil YA, Khoury A, Zuaiter I, Safran O, Liebergall M, Mosheiff R. Femoral neck shortening and varus collapse after navigated fixation of intracapsular femoral neck fractures. J Orthop Trauma. 2012;26(1):19\u201323.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"9916_CR25","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.2106\/JBJS.G.01353","volume":"90","author":"F Liporace","year":"2008","unstructured":"Liporace F, Gaines R, Collinge C, Haidukewych GJ. Results of internal fixation of Pauwels type-3 vertical femoral neck fractures. J Bone Joint Surg Am. 2008;90(8):1654\u20139.","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"9916_CR26","first-page":"e31619","volume":"14","author":"SE Cullen","year":"2022","unstructured":"Cullen SE, Sephton B, Malik I, Aldarragi A, Crossdale M, O\u2019Connor M. A Comparative Study of Dynamic Hip Screw Versus Multiple Cannulated Compression Screw Fixation in Undisplaced Intracapsular Neck of Femur Fractures. Cureus. 2022;14(11):e31619.","journal-title":"Cureus"},{"issue":"1","key":"9916_CR27","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1186\/s13018-020-02189-1","volume":"16","author":"Y Xia","year":"2021","unstructured":"Xia Y, Zhang W, Zhang Z, Wang J, Yan L. Treatment of femoral neck fractures: sliding hip screw or cannulated screws? A meta-analysis. J Orthop Surg Res. 2021;16(1):54.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"9916_CR28","doi-asserted-by":"publisher","first-page":"7915","DOI":"10.1038\/s41598-022-11914-1","volume":"12","author":"J-K Moon","year":"2022","unstructured":"Moon J-K, Lee JI, Hwang K-T, Yang J-H, Park Y-S, Park K-C. Biomechanical comparison of the femoral neck system and the dynamic hip screw in basicervical femoral neck fractures. Sci Rep. 2022;12(1):7915.","journal-title":"Sci Rep"},{"issue":"6","key":"9916_CR29","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1016\/j.jos.2022.09.006","volume":"28","author":"H Lin","year":"2023","unstructured":"Lin H, Lai C, Zhou Z, Wang C, Yu X. Femoral Neck System vs. four cannulated screws in the treatment of Pauwels III femoral neck fracture. J Orthop Sci. 2023;28(6):1373\u20138.","journal-title":"J Orthop Sci"},{"issue":"8","key":"9916_CR30","doi-asserted-by":"publisher","first-page":"886","DOI":"10.1016\/j.clinbiomech.2013.08.007","volume":"28","author":"MA Hawks","year":"2013","unstructured":"Hawks MA, Kim H, Strauss JE, Oliphant BW, Golden RD, Hsieh AH, Nascone JW, O\u2019Toole RV. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone. Clin Biomech (Bristol). 2013;28(8):886\u201391.","journal-title":"Clin Biomech (Bristol)"},{"issue":"11","key":"9916_CR31","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.injury.2019.08.024","volume":"50","author":"J Li","year":"2019","unstructured":"Li J, Yin P, Zhang L, Chen H, Tang P. Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis. Injury. 2019;50(11):1895\u2013900.","journal-title":"Injury"},{"issue":"1","key":"9916_CR32","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40634-019-0187-3","volume":"6","author":"V Giordano","year":"2019","unstructured":"Giordano V, Alves DD, Paes RP, Amaral AB, Giordano M, Belangero W, Freitas A, Koch HA, do Amaral NP. The role of the medial plate for Pauwels type III femoral neck fracture: a comparative mechanical study using two fixations with cannulated screws. J Exp Orthop. 2019;6(1):18.","journal-title":"J Exp Orthop"},{"issue":"6","key":"9916_CR33","doi-asserted-by":"publisher","first-page":"313","DOI":"10.5152\/j.aott.2024.24076","volume":"58","author":"Y Onder","year":"2024","unstructured":"Onder Y, Bulut T, Eroglu ON, Ciklacandir S, Isler Y. Biomechanical comparison of locking femoral neck plate versus cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures. Acta Orthop Traumatol Turc. 2024;58(6):313\u20137.","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"5","key":"9916_CR34","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1302\/0301-620X.82B5.0820679","volume":"82","author":"E Gautier","year":"2000","unstructured":"Gautier E, Ganz K, Kr\u00fcgel N, Gill T, Ganz R. Anatomy of the medial femoral circumflex artery and its surgical implications. J Bone Joint Surg Br. 2000;82(5):679\u201383.","journal-title":"J Bone Joint Surg Br"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-026-09916-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-09916-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-09916-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T01:40:49Z","timestamp":1787017249000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-026-09916-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,13]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9916"],"URL":"https:\/\/doi.org\/10.1186\/s12891-026-09916-5","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7734693\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,13]]},"assertion":[{"value":"28 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was approved by the Ethics Committee of the General Hospital of Southern Theater Command, PLA, and the Ethics Committee of Southern Medical University. All experiments were performed in accordance with institutional guidelines for the use of human cadaveric specimens.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"708"}}