{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T01:13:01Z","timestamp":1778893981945,"version":"3.51.4"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T00:00:00Z","timestamp":1778716800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T00:00:00Z","timestamp":1778889600000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100014584","name":"Universit\u00e4tsmedizin der Johannes Gutenberg-Universit\u00e4t Mainz","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100014584","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Increasing numbers of spine surgery cases and an aging society led to challenges during revision surgery with osteoporotic bone. Safe and stable operative techniques are required.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      In this ex vivo study, human lumbar vertebrae were prepared and then screened for assessing bone density. Eighteen donors (65 vertebrae) with osteoporotic conditions were included. Primary dorsal instrumentation was performed using either standard pedicle screws (6.35\u00a0mm diameter; Group A,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200950) or vertebroplasty screws (VT, 6.35\u00a0mm; Group B,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200915).\n                    <\/jats:p>\n                    <jats:p>This was followed by a standardized pull-out test cycle, after which the vertebrae of group A exhibited pedicle perforations replicating revision conditions. Subsequently, 50 vertebrae from Group A were reassigned to simulate revision conditions and divided into two subgroups (n\u2009=\u200925 each): Group A1 received conventional pedicle screws with an increased diameter (7.5 mm), while Group A2 was treated with cement-augmented pedicle screws (VT, 6.35 mm). A second pull-out test was performed, and statistical analysis was conducted.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The specimens with conventional screws had a lower mean pull-out strength compared to primarily cement-augmented screws during the first pull-out cycle 662.8\u2009\u00b1\u2009365.1 N vs. 1066.1\u2009\u00b1\u2009213.7 N. In the revision model, cement-augmented screws (Group A2) demonstrated a significant higher median pull-out strength compared to larger-diameter conventional screws (Group A1) (687.5 N [IQR: 448.8\u20131137.5 N]; vs. 486.5 N [IQR: 338.8\u2013605.0 N]).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In this ex vivo revision model of osteoporotic bone, increasing screw diameter alone resulted in reduced pull-out strength compared to primary instrumentation, whereas cement-augmented pedicle screws consistently demonstrated superior fixation in both test cycles. These findings highlight the limited effectiveness of increasing screw diameter under revision conditions and support cement augmentation as a biomechanically advantageous strategy in osteoporotic bone, while clinical validation remains necessary.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-026-09971-y","type":"journal-article","created":{"date-parts":[[2026,5,14]],"date-time":"2026-05-14T03:24:56Z","timestamp":1778729096000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The benefit of cement-augmented pedicle screws for revision surgery in osteoporotic bone \u2013 a cadaveric study"],"prefix":"10.1186","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2750-2310","authenticated-orcid":false,"given":"K.","family":"Kafchitsas","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Kontovazainitis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Diaremes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Drees","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Winkler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,5,14]]},"reference":[{"key":"9971_CR1","doi-asserted-by":"publisher","first-page":"634","DOI":"10.31616\/asj.2021.0297","volume":"16","author":"ES Mills","year":"2022","unstructured":"Mills ES, Ton AT, Bouz G, Alluri RK, Hah RJ. Acute Operative Management of Osteoporotic Vertebral Compression Fractures Is Associated with Decreased Morbidity. Asian Spine J. 2022;16:634\u201342. https:\/\/doi.org\/10.31616\/asj.2021.0297.","journal-title":"Asian Spine J"},{"key":"9971_CR2","doi-asserted-by":"publisher","first-page":"269","DOI":"10.21037\/jss-21-29","volume":"7","author":"AD Althoff","year":"2021","unstructured":"Althoff AD, Kamalapathy P, Vatani J, Hassanzadeh H, Li X. Osteoporosis is associated with increased minor complications following single level ALIF and PSIF: an analysis of 7,004 patients. J Spine Surg. 2021;7:269\u201376. https:\/\/doi.org\/10.21037\/jss-21-29.","journal-title":"J Spine Surg"},{"key":"9971_CR3","doi-asserted-by":"publisher","first-page":"486","DOI":"10.3171\/2016.2.SPINE151345","volume":"25","author":"V Puvanesarajah","year":"2016","unstructured":"Puvanesarajah V, Shen FH, Cancienne JM, Novicoff WM, Jain A, Shimer AL, Hassanzadeh H. Risk factors for revision surgery following primary adult spinal deformity surgery in patients 65 years and older. J Neurosurg Spine. 2016;25:486\u201393. https:\/\/doi.org\/10.3171\/2016.2.SPINE151345.","journal-title":"J Neurosurg Spine"},{"key":"9971_CR4","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s005860050045","volume":"7","author":"HJ Wilke","year":"1998","unstructured":"Wilke HJ, Wenger K, Claes L. Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J. 1998;7:148\u201354. https:\/\/doi.org\/10.1007\/s005860050045.","journal-title":"Eur Spine J"},{"key":"9971_CR5","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1002\/jor.1100030305","volume":"3","author":"MM Panjabi","year":"1985","unstructured":"Panjabi MM, Krag M, Summers D, Videman T. Biomechanical time-tolerance of fresh cadaveric human spine specimens. J Orthop Res. 1985;3:292\u2013300. https:\/\/doi.org\/10.1002\/jor.1100030305.","journal-title":"J Orthop Res"},{"key":"9971_CR6","doi-asserted-by":"crossref","unstructured":"Roy-Camille R, Saillant G, Mazel C. (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res:7\u201317.","DOI":"10.1097\/00003086-198602000-00003"},{"key":"9971_CR7","doi-asserted-by":"publisher","first-page":"1714","DOI":"10.1007\/s00330-014-3529-7","volume":"25","author":"JL Wichmann","year":"2015","unstructured":"Wichmann JL, Booz C, Wesarg S, Bauer RW, Kerl JM, Fischer S, Lehnert T, Vogl TJ, Khan MF, Kafchitsas K. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength. Eur Radiol. 2015;25:1714\u201320. https:\/\/doi.org\/10.1007\/s00330-014-3529-7.","journal-title":"Eur Radiol"},{"key":"9971_CR8","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1007\/s00198-020-05297-0","volume":"31","author":"JA Kanis","year":"2020","unstructured":"Kanis JA, Harvey NC, McCloskey E, Bruyere O, Veronese N, Lorentzon M, Cooper C, Rizzoli R, Adib G, Al-Daghri N, Campusano C, Chandran M, Dawson-Hughes B, Javaid K, Jiwa F, Johansson H, Lee JK, Liu E, Messina D, Mkinsi O, Pinto D, Prieto-Alhambra D, Saag K, Xia W, Zakraoui L, Reginster JY. Correction to: Algorithm for the management of patients at low, high and very high risk of osteoporotic fractures. Osteoporos Int. 2020;31:797\u20138. https:\/\/doi.org\/10.1007\/s00198-020-05297-0.","journal-title":"Osteoporos Int"},{"key":"9971_CR9","doi-asserted-by":"publisher","first-page":"E932","DOI":"10.1097\/BRS.0b013e3181c6ec60","volume":"35","author":"V Bullmann","year":"2010","unstructured":"Bullmann V, Schmoelz W, Richter M, Grathwohl C, Schulte TL. Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine (Phila Pa 1976). 2010;35:E932\u2013939. https:\/\/doi.org\/10.1097\/BRS.0b013e3181c6ec60.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR10","first-page":"62","volume":"8","author":"RF McLain","year":"1995","unstructured":"McLain RF, Fry MF, Moseley TA, Sharkey NA. Lumbar pedicle screw salvage: pullout testing of three different pedicle screw designs. J Spinal Disord. 1995;8:62\u20138.","journal-title":"J Spinal Disord"},{"key":"9971_CR11","doi-asserted-by":"crossref","unstructured":"Zindrick MR, Wiltse LL, Widell EH, Thomas JC, Holland WR, Field BT, Spencer CW. (1986) A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. Clin Orthop Relat Res:99\u2013112.","DOI":"10.1097\/00003086-198602000-00012"},{"key":"9971_CR12","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1007\/s00132-010-1603-7","volume":"39","author":"K Kafchitsas","year":"2010","unstructured":"Kafchitsas K, Geiger F, Rauschmann M, Schmidt S. [Cement distribution in vertebroplasty pedicle screws with different designs]. Orthopade. 2010;39:679\u201386. https:\/\/doi.org\/10.1007\/s00132-010-1603-7.","journal-title":"Orthopade"},{"key":"9971_CR13","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1007\/s00586-014-3476-7","volume":"23","author":"RA Kueny","year":"2014","unstructured":"Kueny RA, Kolb JP, Lehmann W, Puschel K, Morlock MM, Huber G. Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing. Eur Spine J. 2014;23:2196\u2013202. https:\/\/doi.org\/10.1007\/s00586-014-3476-7.","journal-title":"Eur Spine J"},{"key":"9971_CR14","doi-asserted-by":"publisher","first-page":"52","DOI":"10.3171\/SPI-08\/01\/052","volume":"8","author":"AT Jacob","year":"2008","unstructured":"Jacob AT, Ingalhalikar AV, Morgan JH, Channon S, Lim TH, Torner JC, Hitchon PW. Biomechanical comparison of single- and dual-lead pedicle screws in cadaveric spine. J Neurosurg Spine. 2008;8:52\u20137. https:\/\/doi.org\/10.3171\/SPI-08\/01\/052.","journal-title":"J Neurosurg Spine"},{"key":"9971_CR15","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","volume":"19","author":"TL Halvorson","year":"1994","unstructured":"Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD. Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976). 1994;19:2415\u201320. https:\/\/doi.org\/10.1097\/00007632-199411000-00008.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR16","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.spinee.2003.11.010","volume":"4","author":"SD Cook","year":"2004","unstructured":"Cook SD, Salkeld SL, Stanley T, Faciane A, Miller SD. Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J. 2004;4:402\u20138. https:\/\/doi.org\/10.1016\/j.spinee.2003.11.010.","journal-title":"Spine J"},{"key":"9971_CR17","doi-asserted-by":"publisher","first-page":"2504","DOI":"10.1097\/00007632-199711010-00007","volume":"22","author":"T Hirano","year":"1997","unstructured":"Hirano T, Hasegawa K, Takahashi HE, Uchiyama S, Hara T, Washio T, Sugiura T, Yokaichiya M, Ikeda M. Structural characteristics of the pedicle and its role in screw stability. Spine (Phila Pa 1976). 1997;22:2504\u20139. https:\/\/doi.org\/10.1097\/00007632-199711010-00007. discussion 2510.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR18","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/00007632-198904000-00004","volume":"14","author":"GR Misenhimer","year":"1989","unstructured":"Misenhimer GR, Peek RD, Wiltse LL, Rothman SL, Widell EH Jr. Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine (Phila Pa 1976). 1989;14:367\u201372. https:\/\/doi.org\/10.1097\/00007632-198904000-00004.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR19","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.1007\/s00586-008-0769-8","volume":"17","author":"S Becker","year":"2008","unstructured":"Becker S, Chavanne A, Spitaler R, Kropik K, Aigner N, Ogon M, Redl H. Assessment of different screw augmentation techniques and screw designs in osteoporotic spines. Eur Spine J. 2008;17:1462\u20139. https:\/\/doi.org\/10.1007\/s00586-008-0769-8.","journal-title":"Eur Spine J"},{"key":"9971_CR20","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","volume":"16","author":"S Soshi","year":"1991","unstructured":"Soshi S, Shiba R, Kondo H, Murota K. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine (Phila Pa 1976). 1991;16:1335\u201341. https:\/\/doi.org\/10.1097\/00007632-199111000-00015.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR21","doi-asserted-by":"publisher","first-page":"1542","DOI":"10.1016\/j.spinee.2025.01.018","volume":"25","author":"MK Hsieh","year":"2025","unstructured":"Hsieh MK, Chen WP, Lee DM, Li YD, Kao FC, Chiang HH, Tsai TT, Fu TS, Lai PL, Tai CL. The biomechanical impact of cement volume and filling pattern for augmented pedicle screws using various density testing blocks. Spine J. 2025;25:1542\u201351. https:\/\/doi.org\/10.1016\/j.spinee.2025.01.018.","journal-title":"Spine J"},{"key":"9971_CR22","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1097\/00007632-200107150-00009","volume":"26","author":"MA Liebschner","year":"2001","unstructured":"Liebschner MA, Rosenberg WS, Keaveny TM. Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine (Phila Pa 1976). 2001;26:1547\u201354. https:\/\/doi.org\/10.1097\/00007632-200107150-00009.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR23","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.medengphy.2016.11.012","volume":"40","author":"V Varghese","year":"2017","unstructured":"Varghese V, Kumar GS, Krishnan V. Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models. Med Eng Phys Feb. 2017;40:28\u201338.","journal-title":"Med Eng Phys Feb"},{"key":"9971_CR24","first-page":"112880","volume":"190","author":"M Hollensteiner","year":"2025","unstructured":"Hollensteiner M, Greinwald M, Sandriesser S, Augat P. Screw pullout strength in osteoporotic bone: A comparative study of synthetic femur surrogates. J Biomech 2025 Sep. 2025;190:112880. 10.1016\/.","journal-title":"J Biomech 2025 Sep"},{"key":"9971_CR25","doi-asserted-by":"publisher","first-page":"2438","DOI":"10.1097\/00007632-199312000-00012","volume":"18","author":"M Law","year":"1993","unstructured":"Law M, Tencer AF, Anderson PA. Caudo-cephalad loading of pedicle screws: mechanisms of loosening and methods of augmentation. Spine (Phila Pa 1976). 1993;18:2438\u201343. https:\/\/doi.org\/10.1097\/00007632-199312000-00012.","journal-title":"Spine (Phila Pa 1976)"},{"key":"9971_CR26","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1007\/s00586-015-3904-3","volume":"26","author":"R Bostelmann","year":"2017","unstructured":"Bostelmann R, Keiler A, Steiger HJ, et al. Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading. Eur Spine J. 2017;26:181\u20138. https:\/\/doi.org\/10.1007\/s00586-015-3904-3.","journal-title":"Eur Spine J"},{"key":"9971_CR27","unstructured":"Standard Specification and Test Methods for Metallic. Medical Bone Screws. https:\/\/store.astm.org\/f0543-17.html."}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-026-09971-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-09971-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-09971-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T00:34:14Z","timestamp":1778891654000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-026-09971-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,14]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["9971"],"URL":"https:\/\/doi.org\/10.1186\/s12891-026-09971-y","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,14]]},"assertion":[{"value":"3 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics committee of the Medical Faculty (University of Frankfurt am Main, Germany) approval was waived as this cadaver study involved specimens with completely anonymized data from a body donor program. All individuals have provided informed consent prior to their death to be used for medical research or education. All methods were carried out in accordance with local guidelines and regulations (Instituto de Biomec\u00e1nica (IBV), Camino de Vera s\/n, Edificio 9C, 46022 \u00b7 Valencia Spain).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"418"}}