{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T22:59:31Z","timestamp":1785452371077,"version":"3.56.0"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T00:00:00Z","timestamp":1780012800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T00:00:00Z","timestamp":1785456000000},"content-version":"vor","delay-in-days":63,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100009619","name":"Japan Agency for Medical Research and Development","doi-asserted-by":"crossref","award":["JP22he0122010"],"award-info":[{"award-number":["JP22he0122010"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"crossref"}]},{"name":"JSPS KAKENHI","award":["JP 23K10426"],"award-info":[{"award-number":["JP 23K10426"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Preoperative planning is essential for optimal outcomes post-total hip arthroplasty (THA). Appropriate stem size and compatibility with femoral dimensions are essential in THA to prevent distal fixation. Previous studies have proposed deep learning-based models with image recognition for preoperative planning to determine the best-fit stem; however, whether size and compatibility are adequately optimized remains unclear. This study developed methods that may assist surgeons in preoperative planning to estimate the stem size and compatibility using supervised machine learning models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two Random Forest (RF) models were developed to estimate the best-fit stem size and stem compatibility with the femoral geometry. Femoral size information measured at 10 locations from computed tomography images of 320 hips was used to train the models. The training data included the sizes and compatibility information as the target variables for supervised learning provided by a simulation software currently used in clinical practice to determine the optimal stem. As part of feature engineering, ratios derived from combinations of the 10 measured values were used as learning data. The size estimation model was designed as a seven-class classification model, whereas the compatibility estimation model was a binary classification model, predicting whether the stem will exclusively fit distally or not. Both models were tested using data from 109 hips of patients who underwent THA. The model performances were assessed using accuracy, F1 score, precision, and recall. Each parameter\u2019s impact was determined using feature importance analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The size and compatibility estimation models trained without ratio information showed accuracies of 89.0% (exact-match: 46.8%) and 85.3%, respectively. When it was included, the models\u2019 performance improved, with the size and compatibility estimation accuracies increasing to 92.7% (exact-match: 39.4%) and 87.2%, respectively. Feature importance analysis highlighted that distal medullary cavity diameter is key in size estimation, while overall femoral dimensions are vital for compatibility estimation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study developed models that estimate the two critical factors in stem selection: size and compatibility. These models may support preoperative planning for THA using the Accolade II stem, although further validation is required to establish applicability to other implant systems.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-026-10022-9","type":"journal-article","created":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T03:45:44Z","timestamp":1780026344000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimizing preoperative planning for total hip arthroplasty using random forest models to predict stem size and compatibility"],"prefix":"10.1186","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2742-4183","authenticated-orcid":false,"given":"Takehiro","family":"Kaneoka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8509-1850","authenticated-orcid":false,"given":"Takashi","family":"Imagama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6635-3541","authenticated-orcid":false,"given":"Tomoya","family":"Okazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0664-4136","authenticated-orcid":false,"given":"Yuta","family":"Matsuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6363-560X","authenticated-orcid":false,"given":"Takehiro","family":"Kawakami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1627-7368","authenticated-orcid":false,"given":"Kazuhiro","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-8535-1589","authenticated-orcid":false,"given":"Kei","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5519-4306","authenticated-orcid":false,"given":"Yoshiyuki","family":"Asai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6367-1299","authenticated-orcid":false,"given":"Takashi","family":"Sakai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,29]]},"reference":[{"key":"10022_CR1","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.arth.2004.09.058","volume":"20","author":"WY Shon","year":"2005","unstructured":"Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty. 2005;20:427.","journal-title":"J Arthroplasty"},{"key":"10022_CR2","first-page":"1585","volume":"38","author":"DM Gerhardt","year":"2014","unstructured":"Gerhardt DM, Sanders RJ, de Visser E, van Susante JL. Excessive polyethylene wear and acetabular bone defects from standard use of a hooded acetabular insert in total hip arthroplasty. Int Orthop. 2014;38:1585\u201390.","journal-title":"Int Orthop"},{"key":"10022_CR3","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1302\/0301-620X.80B4.0800711","volume":"80","author":"N Sugano","year":"1998","unstructured":"Sugano N, Noble PC, Kamaric E, Salama JK, Ochi T, Tullos HS. The morphology of the femur in developmental dysplasia of the hip. J Bone Joint Surg Br. 1998;80:711\u20139.","journal-title":"J Bone Joint Surg Br"},{"key":"10022_CR4","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1177\/230949901001800304","volume":"18","author":"M Umer","year":"2010","unstructured":"Umer M, Sepah YJ, Khan A, Wazir A, Ahmed M, Jawad MU. Morphology of the proximal femur in a Pakistani population. J Orthop Surg (Hong Kong). 2010;18:279\u201381.","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"10022_CR5","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.arth.2011.04.003","volume":"26","author":"HJ Cooper","year":"2011","unstructured":"Cooper HJ, Jacob AP, Rodriguez JA. Distal fixation of proximally coated tapered stems may predispose to a failure of osteointegration. J Arthroplasty. 2011;26:78\u201383.","journal-title":"J Arthroplasty"},{"key":"10022_CR6","doi-asserted-by":"publisher","first-page":"300060521105887","DOI":"10.1177\/03000605211058874","volume":"49","author":"X Ding","year":"2021","unstructured":"Ding X, Zhang B, Li W, Huo J, Liu S, Wu T, et al. Value of preoperative three-dimensional planning software (AI-HIP) in primary total hip arthroplasty: a retrospective study. J Int Med Res. 2021;49:3000605211058874.","journal-title":"J Int Med Res"},{"key":"10022_CR7","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/S0883-5403(99)90210-3","volume":"14","author":"N Sugano","year":"1999","unstructured":"Sugano N, Noble PC, Kamaric E. Predicting the position of the femoral head center. J Arthroplasty. 1999;14:102\u20137.","journal-title":"J Arthroplasty"},{"key":"10022_CR8","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1007\/s00590-016-1796-5","volume":"26","author":"D Inoue","year":"2016","unstructured":"Inoue D, Kabata T, Maeda T, Kajino Y, Yamamoto T, Takagi T, et al. The correlation between clinical radiological outcome and contact state of implant and femur using three-dimensional templating software in cementless total hip arthroplasty. Eur J Orthop Surg Traumatol. 2016;26:591\u20138.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"10022_CR9","doi-asserted-by":"crossref","unstructured":"Gruen TA, McNeice GM, Amstutz HC. \u2018Modes of failure\u2019 of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17\u201327.","DOI":"10.1097\/00003086-197906000-00002"},{"key":"10022_CR10","doi-asserted-by":"publisher","first-page":"1827016","DOI":"10.1155\/2017\/1827016","volume":"2017","author":"Q Wang","year":"2017","unstructured":"Wang Q, Luo Z, Huang J, Feng Y, Liu Z. A novel ensemble method for imbalanced data learning: bagging of extrapolation-SMOTE SVM. Comput Intell Neurosci. 2017;2017:1827016.","journal-title":"Comput Intell Neurosci"},{"key":"10022_CR11","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1016\/j.arth.2020.10.016","volume":"36","author":"M Brenneis","year":"2021","unstructured":"Brenneis M, Braun S, van Drongelen S, Fey B, Tarhan T, Stief F, et al. Accuracy of preoperative templating in total hip arthroplasty with special focus on stem morphology: a randomized comparison between common digital and three-dimensional planning using biplanar radiographs. J Arthroplasty. 2021;36:1149\u201355.","journal-title":"J Arthroplasty"},{"key":"10022_CR12","doi-asserted-by":"publisher","first-page":"531","DOI":"10.1016\/j.otsr.2017.03.001","volume":"103","author":"D Mainard","year":"2017","unstructured":"Mainard D, Barbier O, Knafo Y, Belleville R, Mainard-Simard L, Gross JB. Accuracy and reproducibility of preoperative three-dimensional planning for total hip arthroplasty using biplanar low-dose radiographs: a pilot study. Orthop Traumatol Surg Res. 2017;103:531\u20136.","journal-title":"Orthop Traumatol Surg Res"},{"key":"10022_CR13","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1177\/1120700018776311","volume":"29","author":"E Schiffner","year":"2019","unstructured":"Schiffner E, Latz D, Jungbluth P, Grassmann JP, Tanner S, Karbowski A, et al. Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty? Hip Int. 2019;29:270\u20135.","journal-title":"Hip Int"},{"issue":"1","key":"10022_CR14","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/s13018-021-02294-9","volume":"16","author":"J Huo","year":"2021","unstructured":"Huo J, Huang G, Han D, Wang X, Bu Y, Chen Y, et al. Value of 3D preoperative planning for primary total hip arthroplasty based on artificial intelligence technology. J Orthop Surg Res. 2021;16(1):156.","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"10022_CR15","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/S1350-4533(03)00018-3","volume":"25","author":"M Viceconti","year":"2003","unstructured":"Viceconti M, Lattanzi R, Antonietti B, Paderni S, Olmi R, Sudanese A, et al. CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning. Med Eng Phys. 2003;25(5):371\u20137.","journal-title":"Med Eng Phys"},{"key":"10022_CR16","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1007\/s00264-023-06029-9","volume":"48","author":"W Yang","year":"2024","unstructured":"Yang W, Gao T, Liu X, Shen K, Lin F, Weng Y, et al. Clinical application of artificial intelligence-assisted three-dimensional planning in direct anterior approach hip arthroplasty. Int Orthop. 2024;48:773\u201383.","journal-title":"Int Orthop"},{"key":"10022_CR17","doi-asserted-by":"publisher","first-page":"833","DOI":"10.1002\/jbmr.4292","volume":"36","author":"J Smets","year":"2021","unstructured":"Smets J, Shevroja E, H\u00fcgle T, Leslie WD, Hans D. Machine learning solutions for osteoporosis-A review. J Bone Min Res. 2021;36:833\u201351.","journal-title":"J Bone Min Res"},{"key":"10022_CR18","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.artd.2022.07.011","volume":"17","author":"Y Saiki","year":"2022","unstructured":"Saiki Y, Kabata T, Ojima T, Okada S, Hayashi S, Tsuchiya H. Machine learning algorithm to predict worsening of flexion range of motion after total knee arthroplasty. Arthroplast Today. 2022;17:66\u201373.","journal-title":"Arthroplast Today"},{"key":"10022_CR19","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1145\/2347736.2347755","volume":"55","author":"P Domingos","year":"2012","unstructured":"Domingos P. A few useful things to know about machine learning. Commun ACM. 2012;55:78\u201387.","journal-title":"Commun ACM"},{"key":"10022_CR20","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1016\/j.arth.2023.11.021","volume":"39","author":"SJ Jang","year":"2024","unstructured":"Jang SJ, Alpaugh K, Kunze KN, Li TY, Mayman DJ, Vigdorchik JM et al. Deep-learning automation of preoperative radiographic parameters associated with early periprosthetic femur fracture after total hip arthroplasty. J Arthroplasty. 2024;39:1191-8.e2.","journal-title":"J Arthroplasty"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-026-10022-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-10022-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-10022-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T22:36:28Z","timestamp":1785450988000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-026-10022-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,29]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["10022"],"URL":"https:\/\/doi.org\/10.1186\/s12891-026-10022-9","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,29]]},"assertion":[{"value":"4 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study\u2019s protocol was approved by the by the Ethics Committee of Yamaguchi University Graduate School of Medicine (approval number: H2021-166-2), and informed consent was obtained from all participants. The ethical standards from the 1964 Helsinki declaration and its later amendments were upheld.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"642"}}