{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T09:05:06Z","timestamp":1784365506577,"version":"3.55.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T00:00:00Z","timestamp":1784246400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T00:00:00Z","timestamp":1784332800000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-026-10134-2","type":"journal-article","created":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T05:34:49Z","timestamp":1784266489000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Reinforcement K-wires reduce the risk of tibial plateau and lateral cortex fractures during open wedge high tibial osteotomy: a prospective comparative cohort study"],"prefix":"10.1186","volume":"27","author":[{"given":"Ebeed","family":"Yasin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Darweash","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Salman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alaa","family":"Abououf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Abdel-Wahed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hosam El-Din","family":"Amin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,17]]},"reference":[{"key":"10134_CR1","doi-asserted-by":"publisher","unstructured":"Brouwer RW, Huizinga MR, Duivenvoorden T, van Raaij TM, Verhagen AP, Bierma-Zeinstra SMA, et al. Osteotomy for treating knee osteoarthritis. Cochrane Database Syst Reviews. 2014;2014(12). https:\/\/doi.org\/10.1002\/14651858.CD004019.PUB4\/EPDF\/ABSTRACT. PubMed PMID: 25503775.","DOI":"10.1002\/14651858.CD004019.PUB4\/EPDF\/ABSTRACT"},{"issue":"1","key":"10134_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s43019-020-00076-x","volume":"33","author":"YG Na","year":"2021","unstructured":"Na YG, Lee BK, Choi JU, Lee BH, Sim JA. Change of joint-line convergence angle should be considered for accurate alignment correction in high tibial osteotomy. Knee Surg Relat Res. 2021;33(1):1\u201310. https:\/\/doi.org\/10.1186\/s43019-020-00076-x.","journal-title":"Knee Surg Relat Res"},{"key":"10134_CR3","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1007\/s00264-009-0902-2","volume":"34","author":"AE Staubli","year":"2010","unstructured":"Staubli AE, Jacob HAC. Evolution of open-wedge high-tibial osteotomy: experience with a special angular stable device for internal fixation without interposition material. Int Orthop. 2010;34:167\u201372. https:\/\/doi.org\/10.1007\/s00264-009-0902-2. (2 SPECIAL ISSUE).","journal-title":"Int Orthop"},{"issue":"1","key":"10134_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s43019-021-00130-2","volume":"34","author":"BY Kang","year":"2022","unstructured":"Kang BY, Lee DK, Kim HS, Wang JH. How to achieve an optimal alignment in medial opening wedge high tibial osteotomy? Knee Surg Relat Res. 2022;34(1):1\u201311. https:\/\/doi.org\/10.1186\/s43019-021-00130-2.","journal-title":"Knee Surg Relat Res"},{"issue":"1","key":"10134_CR5","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.arthro.2011.06.034","volume":"28","author":"R Takeuchi","year":"2012","unstructured":"Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, et al. Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthrosc - J Arthroscopic Relat Surg. 2012;28(1):85\u201394. https:\/\/doi.org\/10.1016\/j.arthro.2011.06.034. PubMed PMID: 21982387.","journal-title":"Arthrosc - J Arthroscopic Relat Surg"},{"key":"10134_CR6","doi-asserted-by":"publisher","unstructured":"Dexel J, Fritzsche H, Beyer F, Harman MK, L\u00fctzner J. Open-wedge high tibial osteotomy: incidence of lateral cortex fractures and influence of fixation device on osteotomy healing. Knee Surgery, Sports Traumatology, Arthroscopy. 2017:832\u20137. https:\/\/doi.org\/10.1007\/s00167-015-3730-5. PubMed PMID: 26254088.","DOI":"10.1007\/s00167-015-3730-5"},{"issue":"1","key":"10134_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-018-0872-4","volume":"13","author":"M Donnez","year":"2018","unstructured":"Donnez M, Ollivier M, Munier M, Berton P, Podgorski JP, Chabrand P, et al. Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study. J Orthop Surg Res. 2018;13(1):1\u20138. https:\/\/doi.org\/10.1186\/s13018-018-0872-4 . PubMed PMID: 29986731.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"10134_CR8","doi-asserted-by":"publisher","first-page":"e7","DOI":"10.1016\/j.eats.2015.08.016","volume":"5","author":"YS Lee","year":"2016","unstructured":"Lee YS, Lee MC, Kang SG, Elazab A, Oh WS. Open-wedge high tibial osteotomy using a protective cutting system: technical advancement for the accuracy of the osteotomy and avoiding intraoperative complications. Arthrosc Tech. 2016;5(1):e7\u201310. https:\/\/doi.org\/10.1016\/j.eats.2015.08.016.","journal-title":"Arthrosc Tech"},{"issue":"10","key":"10134_CR9","doi-asserted-by":"publisher","first-page":"3173","DOI":"10.1007\/s00167-019-05806-7","volume":"28","author":"F Gulagaci","year":"2020","unstructured":"Gulagaci F, Jacquet C, Ehlinger M, Sharma A, Kley K, Wilson A, et al. A protective hinge wire, intersecting the osteotomy plane, can reduce the occurrence of perioperative hinge fractures in medial opening wedge osteotomy. Knee Surg Sports Traumatol Arthrosc. 2020;28(10):3173\u201382. https:\/\/doi.org\/10.1007\/s00167-019-05806-7 . PubMed PMID: 31773202.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"10134_CR10","doi-asserted-by":"publisher","unstructured":"Staubli AE, De Simoni C, Babst R, Lobenhoffer P. TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia - early results in 92 cases. Injury. 2003;34(SUPPL. 2):3\u201310. https:\/\/doi.org\/10.1016\/j.injury.2003.09.025. PubMed PMID: 14580986.","DOI":"10.1016\/j.injury.2003.09.025"},{"key":"10134_CR11","doi-asserted-by":"publisher","first-page":"33","DOI":"10.21037\/aoj.2017.06.06","volume":"2","author":"M Capella","year":"2017","unstructured":"Capella M, Gennari E, Dolfin M, Saccia F. Indications and results of high tibial osteotomy. Ann Jt. 2017;2:33\u201333. https:\/\/doi.org\/10.21037\/aoj.2017.06.06.","journal-title":"Ann Jt"},{"issue":"3","key":"10134_CR12","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1177\/036354658201000306","volume":"10","author":"J Gillquist","year":"1982","unstructured":"Gillquist J, Lysholm J. Evaluation of knee ligament surgery results with special emphasis on use of a scoring scale. Am J Sports Med. 1982;10(3):150\u20134.","journal-title":"Am J Sports Med"},{"issue":"7","key":"10134_CR13","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1302\/0301-620X.99B7","volume":"99B","author":"H Ogawa","year":"2017","unstructured":"Ogawa H, Matsumoto K, Akiyama H. The prevention of a lateral hinge fracture as a complication of a medial opening wedge high tibial osteotomy. Bone Joint J. 2017;99B(7):887\u201393. https:\/\/doi.org\/10.1302\/0301-620X.99B7. .BJJ-2016-0927.R1 PubMed PMID: 28663393.","journal-title":"Bone Joint J"},{"issue":"10","key":"10134_CR14","doi-asserted-by":"publisher","first-page":"1313","DOI":"10.1302\/0301-620X.99B10.BJJ-2017-0103","volume":"99\u2013B","author":"R Nakamura","year":"2017","unstructured":"Nakamura R, Komatsu N, Fujita K, Kuroda K, Takahashi M, Omi R, et al. Appropriate hinge position for prevention of unstable lateral hinge fracture in open wedge high tibial osteotomy. Bone Joint J. 2017;99\u2013B(10):1313\u20138. https:\/\/doi.org\/10.1302\/0301-620X.99B10.BJJ-2017-0103. R1 PubMed PMID: 28963152.","journal-title":"Bone Joint J"},{"key":"10134_CR15","doi-asserted-by":"publisher","unstructured":"Peez C, Deichsel A, Zderic I, Richards RG, Drenchev L, Skulev HK et al. Fixation of Takeuchi type II\/III lateral hinge fractures provides favourable stability of a medial open wedge high tibial osteotomy\u2014a biomechanical study. Knee Surgery, Sports Traumatology, Arthroscopy. 2025;33(4):1428\u201342. https:\/\/doi.org\/10.1002\/ksa.12560. PubMed PMID: 39675026.","DOI":"10.1002\/ksa.12560"},{"issue":"3","key":"10134_CR16","doi-asserted-by":"publisher","first-page":"751","DOI":"10.1007\/s00167-019-05404-7","volume":"28","author":"E Dessyn","year":"2020","unstructured":"Dessyn E, Sharma A, Donnez M, Chabrand P, Ehlinger M, Argenson JN, et al. Adding a protective K-wire during opening high tibial osteotomy increases lateral hinge resistance to fracture. Knee Surg Sports Traumatol Arthrosc. 2020;28(3):751\u20138. https:\/\/doi.org\/10.1007\/s00167-019-05404-7 . PubMed PMID: 30783689.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"10134_CR17","doi-asserted-by":"publisher","first-page":"683","DOI":"10.52312\/jdrs.2025.2252","volume":"36","author":"TE Erdem","year":"2025","unstructured":"Erdem TE, Ozkaya M, K\u0131r\u0131lmaz A, Saray A, Yaka H, Turkmen F. Evaluation of the effectiveness of Kirschner wires in preventing lateral hinge fractures in high tibial osteotomy: a finite element analysis. Jt Dis Relat Surg. 2025;36(3):683\u201395. https:\/\/doi.org\/10.52312\/jdrs.2025.2252. PubMed PMID: 40784001.","journal-title":"Jt Dis Relat Surg"},{"key":"10134_CR18","doi-asserted-by":"publisher","unstructured":"Gawish HM, Elghaish MAI, Aziz WHHE, Elfekky M, Abou Helwo AHS, Waly AHT. The sentinel wires technique for safe open wedge high tibial osteotomy. Arthrosc Tech. 2025;14(7). https:\/\/doi.org\/10.1016\/j.eats.2025.103591.","DOI":"10.1016\/j.eats.2025.103591"},{"key":"10134_CR19","doi-asserted-by":"publisher","unstructured":"Mahmoud HF, Farhan AH, Abdelwahab AM, Elshaer AM, Mahmoud MA, Fahmy FS. Is it beneficial to use lateral protective crossing K-wires during medial open wedge high tibial osteotomy? A retrospective comparative study. J Orthop Surg Res. 2025;20(1). https:\/\/doi.org\/10.1186\/s13018-025-05524-6 . PubMed PMID: 39910661.","DOI":"10.1186\/s13018-025-05524-6"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-026-10134-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-10134-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-10134-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T08:32:05Z","timestamp":1784363525000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-026-10134-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,17]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["10134"],"URL":"https:\/\/doi.org\/10.1186\/s12891-026-10134-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,17]]},"assertion":[{"value":"2 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was conducted in accordance with the principles outlined in the Declaration of Helsinki and was approved by the Aswan University Ethics Committee (IEC Ref. No: 750\/3\/23). Written informed consent was obtained from the patients.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"612"}}