{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T16:00:19Z","timestamp":1790352019095,"version":"4.1.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,6]],"date-time":"2026-07-06T00:00:00Z","timestamp":1783296000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:00:00Z","timestamp":1790294400000},"content-version":"vor","delay-in-days":81,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100002865","name":"Chongqing Municipal Science and Technology Bureau","doi-asserted-by":"publisher","award":["No.cstc2020jscx-sbqwX0010"],"award-info":[{"award-number":["No.cstc2020jscx-sbqwX0010"]}],"id":[{"id":"10.13039\/501100002865","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"DOI":"10.1186\/s12891-026-10171-x","type":"journal-article","created":{"date-parts":[[2026,7,5]],"date-time":"2026-07-05T22:47:22Z","timestamp":1783291642000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Mechanical effects of valgus osteotomy angle and re-fixation strategies on re-fixation of the femoral neck fracture: a finite element analysis"],"prefix":"10.1186","volume":"27","author":[{"given":"Hongyu","family":"Lin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fukang","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taiyou","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heling","family":"Tan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuquan","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,6]]},"reference":[{"key":"10171_CR1","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1097\/00003086-200402000-00010","volume":"419","author":"V Mathews","year":"2004","unstructured":"Mathews V, Cabanela ME. Femoral neck nonunion treatment. Clin Orthop Relat Res. 2004;419:57\u201364.","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"10171_CR2","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1097\/BOT.0000000000002355","volume":"36","author":"CA Collinge","year":"2022","unstructured":"Collinge CA, Finlay A, Rodriguez-Buitrago A, Beltran MJ, Mitchell PM, Mir HR, et al. Treatment failure in femoral neck fractures in adults less than 50 years of age: analysis of 492 patients repaired at 26 North American trauma centers. J Orthop Trauma. 2022;36(6):271\u20139.","journal-title":"J Orthop Trauma"},{"issue":"5","key":"10171_CR3","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1302\/0301-620X.71B5.2584247","volume":"71","author":"RK Marti","year":"1989","unstructured":"Marti RK, Sch\u00fcller HM, Raaymakers EL. Intertrochanteric osteotomy for non-union of the femoral neck. J Bone Joint Surg Br. 1989;71(5):782\u20137.","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"10171_CR4","doi-asserted-by":"publisher","first-page":"25","DOI":"10.4103\/0019-5413.125485","volume":"48","author":"J Pingle","year":"2014","unstructured":"Pingle J. Transfracture abduction osteotomy: a solution for nonunion of femoral neck fractures. Indian J Orthop. 2014;48(1):25\u20139.","journal-title":"Indian J Orthop"},{"issue":"1","key":"10171_CR5","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.cjtee.2018.12.003","volume":"22","author":"C Nayak","year":"2019","unstructured":"Nayak C, Acharyya B, Jain M, Kamboj K. Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate. Chin J Traumatol. 2019;22(1):29\u201333.","journal-title":"Chin J Traumatol"},{"issue":"4","key":"10171_CR6","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1007\/s00264-019-04353-7","volume":"44","author":"AS Gavaskar","year":"2020","unstructured":"Gavaskar AS, Srinivasan P, Jeyakumar B, Raj RV. Valgus intertrochanteric osteotomy for femur neck pseudoarthrosis: a simple solution to a complex problem that has stood the test of time. Int Orthop. 2020;44(4):635\u201343.","journal-title":"Int Orthop"},{"issue":"6","key":"10171_CR7","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1016\/j.injury.2012.09.014","volume":"44","author":"WM Gadegone","year":"2013","unstructured":"Gadegone WM, Ramteke AA, Lokhande V, Salphade Y. Valgus intertrochanteric osteotomy and fibular strut graft in the management of neglected femoral neck fracture. Injury. 2013;44(6):763\u20138.","journal-title":"Injury"},{"key":"10171_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-8-4","volume":"8","author":"AS Gavaskar","year":"2013","unstructured":"Gavaskar AS, Chowdary NT. Valgus sliding subtrochanteric osteotomy for neglected fractures of the proximal femur; surgical technique and a retrospective case series. J Orthop Surg Res. 2013;8:4.","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"10171_CR9","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.1148\/rg.2015140301","volume":"35","author":"SE Sheehan","year":"2015","unstructured":"Sheehan SE, Shyu JY, Weaver MJ, Sodickson AD, Khurana B. Proximal femoral fractures: what the orthopedic surgeon wants to know. Radiographics. 2015;35(5):1563\u201384.","journal-title":"Radiographics"},{"issue":"2","key":"10171_CR10","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1302\/0301-620X.76B2.8113286","volume":"76","author":"GM Ferguson","year":"1994","unstructured":"Ferguson GM, Cabanela ME, Ilstrup DM. Total hip arthroplasty after failed intertrochanteric osteotomy. J Bone Joint Surg Br. 1994;76(2):252\u20137.","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"10171_CR11","doi-asserted-by":"publisher","first-page":"301","DOI":"10.5312\/wjo.v7.i5.301","volume":"7","author":"VD Varghese","year":"2016","unstructured":"Varghese VD, Livingston A, Boopalan PR, Jepegnanam TS. Valgus osteotomy for nonunion and neglected neck of femur fractures. World J Orthop. 2016;7(5):301\u20137.","journal-title":"World J Orthop"},{"issue":"2","key":"10171_CR12","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1097\/00005373-199902000-00019","volume":"46","author":"CC Wu","year":"1999","unstructured":"Wu CC, Shih CH, Chen WJ, Tai CL. Treatment of femoral neck nonunions with a sliding compression screw: comparison with and without subtrochanteric valgus osteotomy. J Trauma. 1999;46(2):312\u20137.","journal-title":"J Trauma"},{"issue":"2","key":"10171_CR13","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s10195-009-0049-3","volume":"10","author":"AQ Khan","year":"2009","unstructured":"Khan AQ, Khan MS, Sherwani MK, Agarwal R. Role of valgus osteotomy and fixation with dynamic hip screw and 120 degrees double angle barrel plate in the management of neglected and ununited femoral neck fracture in young patients. J Orthop Traumatol. 2009;10(2):71\u20138.","journal-title":"J Orthop Traumatol"},{"key":"10171_CR14","volume":"2015","author":"XY Su","year":"2015","unstructured":"Su XY, Zhao Z, Zhao JX, Zhang LC, Long AH, Zhang LH, et al. Three-dimensional analysis of the curvature of the femoral canal in 426 Chinese femurs. Biomed Res Int. 2015;2015:318391.","journal-title":"Biomed Res Int"},{"issue":"1","key":"10171_CR15","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1186\/s13018-016-0498-3","volume":"11","author":"M Shen","year":"2016","unstructured":"Shen M, Wang C, Chen H, Rui YF, Zhao S. An update on the Pauwels classification. J Orthop Surg Res. 2016;11(1):161.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"10171_CR16","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s13018-019-1097-x","volume":"14","author":"J Li","year":"2019","unstructured":"Li J, Zhao Z, Yin P, Zhang L, Tang P. Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis. J Orthop Surg Res. 2019;14(1):76.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"10171_CR17","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1186\/s13018-024-04842-5","volume":"19","author":"C Mahaisavariya","year":"2024","unstructured":"Mahaisavariya C, Jitprapaikulsarn S, Mahaisavariya B, Chantarapanich N. Torsional stability of fixation methods in basicervical femoral neck fractures: a biomechanical study. J Orthop Surg Res. 2024;19(1):371.","journal-title":"J Orthop Surg Res"},{"issue":"45","key":"10171_CR18","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000026829","volume":"100","author":"S Tian","year":"2021","unstructured":"Tian S, Liu M, Zhang J, Zhang L, Peng A. Intertrochanteric valgus osteotomy for post-traumatic coxa vara after proximal femur fractures: a retrospective study. Medicine (Baltimore). 2021;100(45):e26829.","journal-title":"Medicine (Baltimore)"},{"issue":"2","key":"10171_CR19","first-page":"210","volume":"85","author":"E \u00d6zkul","year":"2019","unstructured":"\u00d6zkul E, Serdar Necmio\u011flu N, Onur Ziyadano\u011fullar\u0131 M, Alemdar C, Arslan H, Uzel K. An evaluation of treating non-union of femoral neck fractures with valgus angulation osteotomy using sliding hip screws. Acta Orthop Belg. 2019;85(2):210\u20137.","journal-title":"Acta Orthop Belg"},{"issue":"10","key":"10171_CR20","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1007\/s00264-015-2881-9","volume":"39","author":"B Siavashi","year":"2015","unstructured":"Siavashi B, Aalirezaei A, Moosavi M, Golbakhsh MR, Savadkoohi D, Zehtab MJ. A comparative study between multiple cannulated screws and dynamic hip screw for fixation of femoral neck fracture in adults. Int Orthop. 2015;39(10):2069\u201371.","journal-title":"Int Orthop"},{"issue":"1","key":"10171_CR21","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1186\/s13018-023-03991-3","volume":"18","author":"X Sun","year":"2023","unstructured":"Sun X, Yi G, Ao L, Zhou X, Zhang T, Guan TY. Effect analysis of medial bracing plate combined with cannulated screw in unstable femoral neck fracture assisted by surgical hip dislocation: a retrospective study. J Orthop Surg Res. 2023;18(1):498.","journal-title":"J Orthop Surg Res"},{"issue":"2","key":"10171_CR22","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1302\/2046-3758.112.BJR-2021-0282.R1","volume":"11","author":"CH Jung","year":"2022","unstructured":"Jung CH, Cha Y, Yoon HS, Park CH, Yoo JI, Kim JT, et al. Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture\u202f: a finite element analysis. Bone Joint Res. 2022;11(2):102\u201311.","journal-title":"Bone Joint Res"},{"issue":"8","key":"10171_CR23","doi-asserted-by":"publisher","first-page":"3255","DOI":"10.1007\/s00402-024-05449-5","volume":"144","author":"A Yurteri","year":"2024","unstructured":"Yurteri A, Mercan N, U\u011fur L. Comparison of the use of biocompatible materials and titanium in the treatment of midshaft clavicle fractures with a patient-specific plate: a finite element analysis study. Arch Orthop Trauma Surg. 2024;144(8):3255\u201366.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"10171_CR24","doi-asserted-by":"publisher","first-page":"926","DOI":"10.1186\/s13018-023-04415-y","volume":"18","author":"X Cheng","year":"2023","unstructured":"Cheng X, Yang Y, Zhu J, Li G, Chen W, Wang J, et al. Finite element analysis of basicervical femoral neck fracture treated with proximal femoral bionic nail. J Orthop Surg Res. 2023;18(1):926.","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"10171_CR25","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/0021-9290(93)90058-M","volume":"26","author":"G Bergmann","year":"1993","unstructured":"Bergmann G, Graichen F, Rohlmann A. Hip joint loading during walking and running, measured in two patients. J Biomech. 1993;26(8):969\u201390.","journal-title":"J Biomech"},{"issue":"7","key":"10171_CR26","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/S0021-9290(01)00035-5","volume":"34","author":"M Morlock","year":"2001","unstructured":"Morlock M, Schneider E, Bluhm A, Vollmer M, Bergmann G, M\u00fcller V, et al. Duration and frequency of every day activities in total hip patients. J Biomech. 2001;34(7):873\u201381.","journal-title":"J Biomech"},{"issue":"1","key":"10171_CR27","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1186\/s13018-025-05481-0","volume":"20","author":"N Mercan","year":"2025","unstructured":"Mercan N, Erav\u015far E, Safal\u0131 S, U\u011fur L, \u00d6zdemir A. Biomechanical insights through finite element analysis of Bennett fracture fixation: a comparative study of four surgical techniques. J Orthop Surg Res. 2025;20(1):90.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"10171_CR28","doi-asserted-by":"publisher","DOI":"10.1186\/s12891-023-06579-4","volume":"24","author":"CH Jung","year":"2023","unstructured":"Jung CH, Cha Y, Chung JY, Park CH, Kim TY, Yoo JI, et al. Trajectory of bolt and length of plate in femoral neck system determine the stability of femur neck fracture and risk of subsequent subtrochanteric fracture: a finite element analysis. BMC Musculoskelet Disord. 2023;24(1):465.","journal-title":"BMC Musculoskelet Disord"},{"issue":"363","key":"10171_CR29","first-page":"5","volume":"1999","author":"ME Mueller","year":"1957","unstructured":"Mueller ME. The intertrochanteric osteotomy and pseudarthrosis of the femoral neck. Clin Orthop Relat Res. 1957;1999(363):5\u20138.","journal-title":"Clin Orthop Relat Res"},{"key":"10171_CR30","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1097\/00003086-198605000-00024","volume":"206","author":"CH Huang","year":"1986","unstructured":"Huang CH. Treatment of neglected femoral neck fractures in young adults. Clin Orthop Relat Res. 1986;206:117\u201326.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"10171_CR31","doi-asserted-by":"publisher","first-page":"276","DOI":"10.2106\/JBJS.O.00684","volume":"98","author":"J Elkins","year":"2016","unstructured":"Elkins J, Marsh JL, Lujan T, Peindl R, Kellam J, Anderson DD, et al. Motion Predicts Clinical Callus Formation: Construct-Specific Finite Element Analysis of Supracondylar Femoral Fractures. J Bone Joint Surg Am. 2016;98(4):276\u201384.","journal-title":"J Bone Joint Surg Am"},{"issue":"7","key":"10171_CR32","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1002\/jor.22617","volume":"32","author":"M Steiner","year":"2014","unstructured":"Steiner M, Claes L, Ignatius A, Simon U, Wehner T. Disadvantages of interfragmentary shear on fracture healing\u2013mechanical insights through numerical simulation. J Orthop Res. 2014;32(7):865\u201372.","journal-title":"J Orthop Res"},{"issue":"8","key":"10171_CR33","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1097\/BOT.0000000000000869","volume":"31","author":"BJ Yuan","year":"2017","unstructured":"Yuan BJ, Shearer DW, Barei DP, Nork SE. Intertrochanteric osteotomy for femoral neck nonunion: does \u201cundercorrection\u201d result in an acceptable rate of femoral neck union? J Orthop Trauma. 2017;31(8):420\u20136.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"10171_CR34","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1016\/S0736-0266(03)00098-6","volume":"21","author":"P Augat","year":"2003","unstructured":"Augat P, Burger J, Schorlemmer S, Henke T, Peraus M, Claes L. Shear movement at the fracture site delays healing in a diaphyseal fracture model. J Orthop Res. 2003;21(6):1011\u20137.","journal-title":"J Orthop Res"},{"issue":"3","key":"10171_CR35","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2024.111317","volume":"55","author":"H Xian","year":"2024","unstructured":"Xian H, Cheng W, Xie W, Wang L, Luo D, Liu H, et al. Does the angle between dynamic hip screw and anti-rotation screw affect the outcome of vertically oriented femoral neck fractures? A biomechanical analysis and clinical results. Injury. 2024;55(3):111317.","journal-title":"Injury"},{"key":"10171_CR36","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1097\/00003086-200206000-00014","volume":"399","author":"M Jackson","year":"2002","unstructured":"Jackson M, Learmonth ID. The treatment of nonunion after intracapsular fracture of the proximal femur. Clin Orthop Relat Res. 2002;399:119\u201328.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"10171_CR37","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1016\/S0030-5898(20)31516-9","volume":"21","author":"FT Ballmer","year":"1990","unstructured":"Ballmer FT, Ballmer PM, Baumgaertel F, Ganz R, Mast JW. Pauwels osteotomy for nonunions of the femoral neck. Orthop Clin North Am. 1990;21(4):759\u201367.","journal-title":"Orthop Clin North Am"},{"issue":"5","key":"10171_CR38","first-page":"329","volume":"19","author":"JM Hartford","year":"2005","unstructured":"Hartford JM, Patel A, Powell J. Intertrochanteric osteotomy using a dynamic hip screw for femoral neck nonunion. J Orthop Trauma. 2005;19(5):329\u201333.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"10171_CR39","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1007\/s11999-008-0695-4","volume":"467","author":"NK Magu","year":"2009","unstructured":"Magu NK, Rohilla R, Singh R, Tater R. Modified Pauwels\u2019 intertrochanteric osteotomy in neglected femoral neck fracture. Clin Orthop Relat Res. 2009;467(4):1064\u201373.","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"10171_CR40","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1007\/s40846-015-0085-9","volume":"35","author":"S Samsami","year":"2015","unstructured":"Samsami S, Saberi S, Sadighi S, Rouhi G. Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerical investigations. J Med Biol Eng. 2015;35(5):566\u201379.","journal-title":"J Med Biol Eng"},{"issue":"1","key":"10171_CR41","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-024-70346-1","volume":"14","author":"D Liu","year":"2024","unstructured":"Liu D, Huang Q, Wang C, Ren C, Xu Y, He C, et al. Biomechanical evaluation of Gamma 3 nail with anti-rotation screw fixation for unstable femoral neck fractures: a biomechanical study. Sci Rep. 2024;14(1):19356.","journal-title":"Sci Rep"},{"issue":"2","key":"10171_CR42","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1016\/j.injury.2021.11.015","volume":"53","author":"J Fan","year":"2022","unstructured":"Fan J, Xu X, Zhou F. The lateral femoral wall thickness on the risk of post-operative lateral wall fracture in intertrochanteric fracture after DHS fixation: a finite element analysis. Injury. 2022;53(2):346\u201352.","journal-title":"Injury"},{"issue":"10","key":"10171_CR43","doi-asserted-by":"publisher","first-page":"3115","DOI":"10.1016\/j.injury.2022.08.038","volume":"53","author":"X Jiang","year":"2022","unstructured":"Jiang X, Liang K, Du G, Chen Y, Tang Y, Geng K. Biomechanical evaluation of different internal fixation methods based on finite element analysis for Pauwels type III femoral neck fracture. Injury. 2022;53(10):3115\u201323.","journal-title":"Injury"},{"key":"10171_CR44","doi-asserted-by":"publisher","DOI":"10.3389\/fbioe.2023.1116976","volume":"11","author":"Q Huang","year":"2023","unstructured":"Huang Q, Zhang C, Bai H, Wang Q, Li Z, Lu Y, et al. Biomechanical evaluation of two modified intramedullary fixation system for treating unstable femoral neck fractures: a finite element analysis. Front Bioeng Biotechnol. 2023;11:1116976.","journal-title":"Front Bioeng Biotechnol"},{"key":"10171_CR45","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2020.105714","volume":"196","author":"W Zeng","year":"2020","unstructured":"Zeng W, Liu Y, Hou X. Biomechanical evaluation of internal fixation implants for femoral neck fractures: a comparative finite element analysis. Comput Methods Programs Biomed. 2020;196:105714.","journal-title":"Comput Methods Programs Biomed"},{"issue":"3","key":"10171_CR46","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/BOT.0000000000001377","volume":"33","author":"SM Putnam","year":"2019","unstructured":"Putnam SM, Collinge CA, Gardner MJ, Ricci WM, McAndrew CM. Vascular anatomy of the medial femoral neck and implications for surface plate fixation. J Orthop Trauma. 2019;33(3):111\u20135.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"10171_CR47","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1302\/2633-1462.28.BJO-2021-0099.R1","volume":"2","author":"JF Kubik","year":"2021","unstructured":"Kubik JF, Bornes TD, Klinger CE, Dyke JP, Helfet DL. The effect of calcar femoral neck plating on vascularity of the femoral head and neck. Bone Jt Open. 2021;2(8):611\u20137.","journal-title":"Bone Jt Open"},{"issue":"2","key":"10171_CR48","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2025.112160","volume":"56","author":"L McGarry","year":"2025","unstructured":"McGarry L, Rotaru J, Gunaratne R, Hickey I. Medial buttress plate use in neck of femur fracture fixations: a systematic review. Injury. 2025;56(2):112160.","journal-title":"Injury"},{"issue":"3","key":"10171_CR49","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1097\/00005131-199109000-00012","volume":"5","author":"JM Spivak","year":"1991","unstructured":"Spivak JM, Zuckerman JD, Kummer FJ, Frankel VH. Fatigue failure of the sliding screw in hip fracture fixation: a report of three cases. J Orthop Trauma. 1991;5(3):325\u201331.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 6","key":"10171_CR50","doi-asserted-by":"publisher","first-page":"S18","DOI":"10.1016\/j.injury.2015.10.037","volume":"46","author":"A Antabak","year":"2015","unstructured":"Antabak A, Papes D, Haluzan D, Seiwerth S, Fuchs N, Romic I, et al. Reducing damage to the periosteal capillary network caused by internal fixation plating: an experimental study. Injury. 2015;46(Suppl 6):S18-20.","journal-title":"Injury"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-026-10171-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-10171-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-026-10171-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T15:03:25Z","timestamp":1790348605000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12891-026-10171-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,6]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["10171"],"URL":"https:\/\/doi.org\/10.1186\/s12891-026-10171-x","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,6]]},"assertion":[{"value":"13 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was conducted in compliance with the Declaration of Helsinki and was approved by the Ethics Committee of the First Affiliated Hospital of Chongqing Medical University. The need for informed consent to participate was waived for all participants by the ethics committee and the Institutional Review Board (IRB) (Research Ethics Committees of the First Affiliated Hospital of Chongqing Medical University; Approval No. K2023-666). All methods were carried out in accordance with relevant guidelines and regulations.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"806"}}