{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T22:02:04Z","timestamp":1773093724039,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,27]],"date-time":"2019-11-27T00:00:00Z","timestamp":1574812800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,11,27]],"date-time":"2019-11-27T00:00:00Z","timestamp":1574812800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Although various studies have described the outcomes and complications of each treatment for OF 4 in osteoporotic vertebral compression fractures (OVCFs), there is still no consensus on the optimal treatment regimen. This study aimed to investigate the clinical effect of OF 4 in patients with OVCFs treated with percutaneous vertebroplasty (PV) compared with PV in combination with intermediate bilateral pedicle screw fixation (IBPSF).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>A total of 110 patients with OF 4 in OVCFs from January 2011 to December 2013 were reviewed retrospectively and divided into two groups (group A: PV, group B: PV\u2009+\u2009IBPSF). According to the guidelines of the German Society for Orthopaedics and Trauma (DGOU), OF 4 consists of 3 fracture types. The clinical and radiographic assessments were observed preoperatively, postoperatively, and during follow-up.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The patients were followed for an average of 60.50\u2009\u00b1\u200915.20\u2009months (group A) and 58.20\u2009\u00b1\u200917.60\u2009months (group B) without significant differences. No significant differences were found in BMD, BMI and cement volume between the two groups, but differences were found for operation time, blood loss, and hospitalization time. The VAS and ODI scores improved better significantly at the final follow-up in group B but not in group A. Compared with the preoperative values, the postoperative kyphosis angle and loss of fractured segment height significantly improved, but the difference between the groups was significant after 3\u2009months postoperatively. The loss of angular correction and fractured segment height in group A were greater than those in group B. A total of 15 cases of cement leakage were observed in group A and 8 cases in group B, and no complications or revision surgeries were observed in either group. Thirteen new fractures occurred (11 in group A and 2 in group B), which was significant.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>PV with IBPSF could provide effective restoration and maintenance of fractured segment height and segment alignment as well as a lower rate of complications of OF 4 in OVCFs.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12893-019-0646-x","type":"journal-article","created":{"date-parts":[[2019,11,27]],"date-time":"2019-11-27T02:02:32Z","timestamp":1574820152000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Vertebroplasty and vertebroplasty in combination with intermediate bilateral pedicle screw fixation for OF4 in osteoporotic vertebral compression fractures: a retrospective single-Centre cohort study"],"prefix":"10.1186","volume":"19","author":[{"given":"Weiyang","family":"Zhong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinjie","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoji","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhengxue","family":"Quan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,11,27]]},"reference":[{"key":"646_CR1","doi-asserted-by":"publisher","first-page":"2511","DOI":"10.1007\/s00586-014-3591-5","volume":"23","author":"K Schnake","year":"2014","unstructured":"Schnake K, Bouzakri N, Blattert T, et al. Validation of a classification system for osteoporotic thoracolumbar fractures (OF-classification). Eur Spine J. 2014;23:2511.","journal-title":"Eur Spine J"},{"key":"646_CR2","first-page":"2590","volume":"22","author":"KJ Schnake","year":"2013","unstructured":"Schnake KJ, Hahn P, Franck A, et al. Development of a classification system (OF-classification) and of a score for therapeutic decision making (OF-score) for osteoporotic thoracolumbar fractures. Eur Spine J. 2013;22:2590.","journal-title":"Eur Spine J"},{"issue":"2 Suppl","key":"646_CR3","first-page":"46S","volume":"8","author":"KJ Schnake","year":"2018","unstructured":"Schnake KJ, Blattert TR, Hahn P, et al. Classification of osteoporotic thoracolumbar spine fractures: recommendations of the spine section of the German Society for Orthopaedics and Trauma (DGOU). Global\u2002Spine\u2002J. 2018 Sep;8(2 Suppl):46S\u20139S.","journal-title":"Global\u2002Spine\u2002J"},{"issue":"2 Suppl","key":"646_CR4","first-page":"50S","volume":"8","author":"TR Blattert","year":"2018","unstructured":"Blattert TR, Schnake KJ, Gonschorek O, et al. Nonsurgical and surgical Management of Osteoporotic Vertebral Body Fractures: recommendations of the spine section of the German Society for Orthopaedics and Trauma (DGOU). Global\u2002Spine\u2002J. 2018;8(2 Suppl):50S\u20135S.","journal-title":"Global\u2002Spine\u2002J"},{"key":"646_CR5","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s11604-011-0564-z","volume":"29","author":"K Chosa","year":"2011","unstructured":"Chosa K, Naito A, Awai K. Newly developed compression fractures after percutaneous vertebroplasty: comparison with conservative treatment. Jpn J Radiol. 2011;29:335\u201341.","journal-title":"Jpn J Radiol"},{"key":"646_CR6","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.2214\/AJR.10.5586","volume":"196","author":"N Tanigawa","year":"2011","unstructured":"Tanigawa N, Kariya S, Komemushi A, et al. Percutaneous vertebroplasty for osteoporotic compression fractures:long-term evaluation of the technical and clinical outcomes. Am J Roentgenol. 2011;196:1415\u20138.","journal-title":"Am J Roentgenol"},{"key":"646_CR7","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/01.RVI.0000190910.43602.3C","volume":"17","author":"MH Voormolen","year":"2006","unstructured":"Voormolen MH, Lohle PN, Juttmann JR, et al. The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty. J Vasc Interv Radiol. 2006;17:71\u20136.","journal-title":"J Vasc Interv Radiol"},{"key":"646_CR8","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1007\/s00198-012-2065-z","volume":"24","author":"KY Ha","year":"2013","unstructured":"Ha KY, Kim YH. Risk factors affecting progressive collapse of acute osteoporotic spinal fractures. Osteoporos Int. 2013;24:1207\u201313.","journal-title":"Osteoporos Int"},{"key":"646_CR9","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.jocn.2006.12.007","volume":"15","author":"XY Wang","year":"2008","unstructured":"Wang XY, Dai LY, Xu HZ, et al. Biomechanical effect the extent of vertebral body fracture on the thoracolum bar spine with pedicle screw fixation: an in vitro study. J Clin Neurosci. 2008;15:286\u201390.","journal-title":"J Clin Neurosci"},{"key":"646_CR10","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/S0035-1040(07)90242-1","volume":"93","author":"M Freslon","year":"2007","unstructured":"Freslon M, Mosnier T, Gayet LE, et al. Biomechanical evaluation of posterior instrumentation for lumbar burst fracture: comparison of two internal devices. Rev Chir Orthop Reparatrice Appar Mot. 2007;93:213\u201321.","journal-title":"Rev Chir Orthop Reparatrice Appar Mot"},{"key":"646_CR11","doi-asserted-by":"publisher","first-page":"e99156","DOI":"10.1371\/journal.pone.0099156","volume":"9","author":"C Li","year":"2014","unstructured":"Li C, Zhou Y, Wang H, et al. Treatment of unstable thoracolumbar fractures through short segment pedicle screw fixation techniques using pedicle fixation at the level of the fracture: a finite element analysis. PLoS One. 2014;9:e99156.","journal-title":"PLoS One"},{"key":"646_CR12","doi-asserted-by":"publisher","first-page":"e4574","DOI":"10.1097\/MD.0000000000004574","volume":"95","author":"K Li","year":"2016","unstructured":"Li K, Zhang W, Liu D, et al. Pedicle screw fixation combined with intermediate screw at the fracture level for treatment of thoracolumbar fractures: a meta-analysis. Medicine. 2016;95:e4574.","journal-title":"Medicine"},{"key":"646_CR13","doi-asserted-by":"publisher","first-page":"e514","DOI":"10.3928\/01477447-20160427-09","volume":"39","author":"M McDonnell","year":"2016","unstructured":"McDonnell M, Shah KN, Paller DJ, et al. Biomechanical analysis of pedicle screw fixation for thoracolumbar burst fractures. Orthopedics. 2016;39:e514\u20138.","journal-title":"Orthopedics"},{"key":"646_CR14","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.wneu.2016.11.133","volume":"99","author":"B Ozdemir","year":"2017","unstructured":"Ozdemir B, Kanat A, Erturk C, et al. Restoration of anterior vertebral height by short-segment pedicle screw fixation with screwing of fractured vertebra for the treatment of unstable thoracolumbar fractures. World Neurosurg. 2017;99:409\u201317.","journal-title":"World Neurosurg"},{"issue":"2","key":"646_CR15","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.spinee.2018.06.347","volume":"19","author":"Bong Gun Lee","year":"2019","unstructured":"Lee BG, Choi JH, Kim DY, et al. Risk Factors for Newly Developed Osteoporotic Vertebral Compression Fractures Following Treatment for Osteoporotic Vertebral Compression Fractures. Spine. 2018;19(2):301-5.","journal-title":"The Spine Journal"},{"issue":"1","key":"646_CR16","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1186\/s13018-018-0952-5","volume":"13","author":"B Wang","year":"2018","unstructured":"Wang B, Zhao CP, Song LX, et al. Balloon kyphoplasty versus percutaneous vertebroplasty for osteoporotic vertebral compression fracture: a meta-analysis and systematic review. J Orthop Surg Res. 2018;13(1):264.","journal-title":"J Orthop Surg Res"},{"issue":"11","key":"646_CR17","doi-asserted-by":"publisher","first-page":"3411","DOI":"10.1007\/s00586-015-3923-0","volume":"25","author":"J Ding","year":"2016","unstructured":"Ding J, Zhang Q, Zhu J, et al. Risk factors for predicting cement leakage following percutaneous vertebroplasty for osteoporotic vertebral compression fractures. Eur Spine J. 2016;25(11):3411\u20137.","journal-title":"Eur Spine J"},{"issue":"3","key":"646_CR18","first-page":"209","volume":"18","author":"H Wang","year":"2015","unstructured":"Wang H, Sribastav SS, Ye F, et al. Comparison of Percutaneous Vertebroplasty and Balloon Kyphoplasty for the Treatment of Single Level Vertebral Compression Fractures: A Meta-analysis of the Literature. Pain Physician. 2015;18(3):209\u201322.","journal-title":"Pain Physician"},{"issue":"8","key":"646_CR19","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1177\/0284185114544240","volume":"56","author":"D Song","year":"2015","unstructured":"Song D, Meng B, Gan M, et al. The incidence of secondary vertebral fracture of vertebral augmentation techniques versus conservative treatment for painful osteoporotic vertebral fractures: a systematic review and meta-analysis. Acta Radiol. 2015;56(8):970\u20139.","journal-title":"Acta Radiol"},{"key":"646_CR20","doi-asserted-by":"publisher","first-page":"52","DOI":"10.3171\/SPI-08\/01\/052","volume":"8","author":"AT Jacob","year":"2008","unstructured":"Jacob AT, Ingalhalikar AV, Morgan JH, et al. Biomechanical comparison of single- and dual-lead pedicle screws in cadaveric spine. J Neurosurg Spine. 2008;8:52\u20137.","journal-title":"J Neurosurg Spine"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-019-0646-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12893-019-0646-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-019-0646-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,26]],"date-time":"2020-11-26T00:56:26Z","timestamp":1606352186000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-019-0646-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,27]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["646"],"URL":"https:\/\/doi.org\/10.1186\/s12893-019-0646-x","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,27]]},"assertion":[{"value":"17 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The Institutional Review Board of the First Affiliated Hospital of Chongqing Medical University approved this study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"178"}}