{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T16:27:58Z","timestamp":1784392078618,"version":"3.55.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T00:00:00Z","timestamp":1590537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T00:00:00Z","timestamp":1590537600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Monopolar energy (ME) is routinely used in appendectomy. This study aimed to investigate the degree of lateral thermal spread generated by ME and to evaluate the thermal injury sustained by the close-lying tissues.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Appendectomy with a monopolar Maryland dissector was performed in 8 rabbits (at 30 and 60\u2009W power settings). A high-resolution infrared camera was used to record tissue heating during the intervention. After autopsy macroscopic changes were evaluated and tissue samples were subjected to myeloperoxidase (MPO) assay and histological examination.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No significant differences in the extent of thermal spread, MPO activity and histological signs of inflammation were observed between groups. Regardless of the power settings, the heat spread exceeded 2\u2009cm laterally along the mesoappendix when application time exceeded 3\u2009s. The spread of heat through tubular structures in both groups caused a significant temperature rise in the nearby intestinal loop, resulting in perforation (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20093) and necrosis (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u20091).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Application time is critical in thermal spread during appendectomy aided by ME. Tubular anatomic structures can enhance thermal injury on distant tissues. The observed effects of ME bear clinical relevance that need further investigation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12893-020-00735-6","type":"journal-article","created":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T05:02:48Z","timestamp":1590555768000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":23,"title":["Thermal effects of monopolar electrosurgery detected by real-time infrared thermography: an experimental appendectomy study"],"prefix":"10.1186","volume":"20","author":[{"given":"Taras V.","family":"Nechay","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Svetlana M.","family":"Titkova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikhail V.","family":"Anurov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena V.","family":"Mikhalchik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kirill Y.","family":"Melnikov-Makarchyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ekaterina A.","family":"Ivanova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander E.","family":"Tyagunov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abe","family":"Fingerhut","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander V.","family":"Sazhin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,5,27]]},"reference":[{"key":"735_CR1","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.jamcollsurg.2015.03.031","volume":"221","author":"DM Overbey","year":"2015","unstructured":"Overbey DM, Townsend NT, Chapman BC, Bennett DT, Foley LS, Rau AS, et al. Surgical energy-based device injuries and fatalities reported to the food and drug administration. J Am Coll Surg. 2015;221:197\u2013205.e1. https:\/\/doi.org\/10.1016\/j.jamcollsurg.2015.03.031.","journal-title":"J Am Coll Surg"},{"key":"735_CR2","doi-asserted-by":"publisher","first-page":"201","DOI":"10.2471\/BLT.15.159293","volume":"94","author":"TG Weiser","year":"2016","unstructured":"Weiser TG, Haynes AB, Molina G, Lipsitz SR, Esquivel MM, Uribe-Leitz T, et al. Size and distribution of the global volume of surgery in 2012. Bull World Health Organ. 2016;94:201\u2013209F. https:\/\/doi.org\/10.2471\/BLT.15.159293.","journal-title":"Bull World Health Organ"},{"key":"735_CR3","doi-asserted-by":"publisher","first-page":"2480","DOI":"10.1007\/s00464-009-0421-7","volume":"23","author":"C Song","year":"2009","unstructured":"Song C, Tang B, Campbell PA, Cuschieri A. Thermal spread and heat absorbance differences between open and laparoscopic surgeries during energized dissections by electrosurgical instruments. Surg Endosc. 2009;23:2480\u20137.","journal-title":"Surg Endosc"},{"key":"735_CR4","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1067\/j.cpsurg.2015.08.004","volume":"52","author":"DB Jones","year":"2015","unstructured":"Jones DB, Brunt LM, Feldman LS, Mikami DJ, Robinson TN, Jones SB. Safe energy use in the operating room. Curr Probl Surg. 2015;52:447\u201368. https:\/\/doi.org\/10.1067\/j.cpsurg.2015.08.004.","journal-title":"Curr Probl Surg"},{"key":"735_CR5","doi-asserted-by":"crossref","unstructured":"Capelluto E, Champault G. Variations in intraperitoneal temperature during laparoscopic cholecystectomy. Ann Chir. 2000;125:259\u2013262. http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/10829506. Accessed 9 Jan 2019.","DOI":"10.1016\/S0001-4001(00)00130-6"},{"key":"735_CR6","doi-asserted-by":"publisher","first-page":"355","DOI":"10.2478\/v10035-011-0056-y","volume":"83","author":"J Brzezi\u0144ski","year":"2011","unstructured":"Brzezi\u0144ski J, Ka\u0142u\u017cna-Markowska K, Naze M, Str\u00f3\u017cyk G, Dedecjus M. Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStapler\u2122 during thyroidectomy. Pol Przegl Chir. 2011;83:355\u201360. https:\/\/doi.org\/10.2478\/v10035-011-0056-y.","journal-title":"Pol Przegl Chir"},{"key":"735_CR7","unstructured":"Wetter PA, Kavic MS, Levinson CJ, Kelley WE Jr., McDougall EM, Nezhat C. Prevention & management of laparoendoscopic surgical complications. 2nd ed. Society of Laparoendoscopic Surgeons: Miami; 2005."},{"key":"735_CR8","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1016\/j.amsu.2019.11.017","volume":"50","author":"AA Malik","year":"2020","unstructured":"Malik AA, Khan RS, Khan RN, Shakeel O, Ahmed HH, Rahid U, et al. Lack of awareness among surgeons regarding safe use of electrosurgery. A cross sectional survey of surgeons in Pakistan. Ann Med Surg. 2020;50:24\u20137. https:\/\/doi.org\/10.1016\/j.amsu.2019.11.017.","journal-title":"Ann Med Surg"},{"key":"735_CR9","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.1007\/s00464-012-2263-y","volume":"26","author":"LS Feldman","year":"2012","unstructured":"Feldman LS, Fuchshuber P, Jones DB, Mischna J, Schwaitzberg SD, FUSE (fundamental use of surgical energy\u2122) task force. Surgeons don\u2019t know what they don\u2019t know about the safe use of energy in surgery. Surg Endosc. 2012;26:2735\u20139. https:\/\/doi.org\/10.1007\/s00464-012-2263-y.","journal-title":"Surg Endosc"},{"key":"735_CR10","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1109\/TBME.2011.2168956","volume":"59","author":"RE Dodde","year":"2012","unstructured":"Dodde RE, Gee JS, Geiger JD, Shih AJ. Monopolar electrosurgical thermal management for minimizing tissue damage. IEEE Trans Biomed Eng. 2012;59:167\u201373.","journal-title":"IEEE Trans Biomed Eng"},{"key":"735_CR11","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1002\/bjs.6901","volume":"97","author":"PA Sutton","year":"2010","unstructured":"Sutton PA, Awad S, Perkins AC, Lobo DN. Comparison of lateral thermal spread using monopolar and bipolar diathermy, the harmonic scalpel and the Ligasure. Br J Surg. 2010;97:428\u201333. https:\/\/doi.org\/10.1002\/bjs.6901.","journal-title":"Br J Surg"},{"key":"735_CR12","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1111\/bju.12498","volume":"114","author":"LJ Hefermehl","year":"2014","unstructured":"Hefermehl LJ, Largo RA, Hermanns T, Poyet C, Sulser T, Eberli D. Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot-assisted laparoscopic surgery. BJU Int. 2014;114:245\u201352.","journal-title":"BJU Int"},{"key":"735_CR13","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.jviscsurg.2017.12.003","volume":"155","author":"F Borie","year":"2018","unstructured":"Borie F, Mathonnet M, Deleuze A, Millat B, Gravi\u00e9 JF, Johanet H, et al. Risk management for surgical energy-driven devices used in the operating room. J Visc Surg. 2018;155:259\u201364.","journal-title":"J Visc Surg"},{"key":"735_CR14","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1503\/cjs.000711","volume":"55","author":"N Dru\u017eijani\u0107","year":"2012","unstructured":"Dru\u017eijani\u0107 N, Pogoreli\u0107 Z, Perko Z, Mrkli\u0107 I, Tomi\u0107 S. Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, harmonic scalpel and LigaSure. Can J Surg. 2012;55:317\u201321.","journal-title":"Can J Surg"},{"key":"735_CR15","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1089\/lap.2013.0374","volume":"24","author":"JS Lee","year":"2014","unstructured":"Lee JS, Hong TH. Comparison of various methods of Mesoappendix dissection in laparoscopic appendectomy. J Laparoendosc Adv Surg Tech. 2014;24:28\u201331. https:\/\/doi.org\/10.1089\/lap.2013.0374.","journal-title":"J Laparoendosc Adv Surg Tech"},{"key":"735_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13017-016-0090-5","volume":"11","author":"S Di Saverio","year":"2016","unstructured":"Di Saverio S, Birindelli A, Kelly MD, Catena F, Weber DG, Sartelli M, et al. WSES Jerusalem guidelines for diagnosis and treatment of acute appendicitis. World J Emerg Surg. 2016;11:1\u201325. https:\/\/doi.org\/10.1186\/s13017-016-0090-5.","journal-title":"World J Emerg Surg"},{"key":"735_CR17","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.jss.2017.01.014","volume":"212","author":"Z Pogoreli\u0107","year":"2017","unstructured":"Pogoreli\u0107 Z, Kati\u0107 J, Mrkli\u0107 I, Jeron\u010di\u0107 A, \u0160u\u0161njar T, Juki\u0107 M, et al. Lateral thermal damage of mesoappendix and appendiceal base during laparoscopic appendectomy in children: comparison of the harmonic scalpel (Ultracision), bipolar coagulation (LigaSure), and thermal fusion technology (MiSeal). J Surg Res. 2017;212:101\u20137. https:\/\/doi.org\/10.1016\/j.jss.2017.01.014.","journal-title":"J Surg Res"},{"key":"735_CR18","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1007\/s00595-006-3254-1","volume":"36","author":"T Diamantis","year":"2006","unstructured":"Diamantis T, Kontos M, Arvelakis A, Syroukis S, Koronarchis D, Papalois A, et al. Comparison of monopolar electrocoagulation, bipolar electrocoagulation, ultracision, and ligasure. Surg Today. 2006;36:908\u201313.","journal-title":"Surg Today"},{"key":"735_CR19","doi-asserted-by":"publisher","first-page":"e2015.00018","DOI":"10.4293\/JSLS.2015.00018","volume":"19","author":"PF Vetere","year":"2015","unstructured":"Vetere PF, Lazarou G, Apostol R, Khullar P, Okonkwo L, Nezhat F. Postoperative adhesion formation in a rabbit model: Monopolar Electrosurgery versus ultrasonic scalpel. JSLS J Soc Laparoendosc Surg. 2015;19:e2015.00018. https:\/\/doi.org\/10.4293\/JSLS.2015.00018.","journal-title":"JSLS J Soc Laparoendosc Surg"},{"key":"735_CR20","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1016\/j.jpedsurg.2018.02.081","volume":"53","author":"JR Robinson","year":"2018","unstructured":"Robinson JR, Carter NH, Gibson C, Brinkman AS, Van Arendonk K, Speck KE, et al. Improving the value of care for appendectomy through an individual surgeon-specific approach. J Pediatr Surg. 2018;53:1181\u20136.","journal-title":"J Pediatr Surg"},{"key":"735_CR21","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1007\/s00464-009-0632-y","volume":"24","author":"JR Korndorffer","year":"2010","unstructured":"Korndorffer JR, Fellinger E, Reed W. SAGES guideline for laparoscopic appendectomy. Surg Endosc. 2010;24:757\u201361. https:\/\/doi.org\/10.1007\/s00464-009-0632-y.","journal-title":"Surg Endosc"},{"key":"735_CR22","doi-asserted-by":"publisher","first-page":"4668","DOI":"10.1007\/s00464-016-5245-7","volume":"30","author":"RR Gorter","year":"2016","unstructured":"Gorter RR, Eker HH, Gorter-Stam MAW, Abis GSA, Acharya A, Ankersmit M, et al. Diagnosis and management of acute appendicitis. EAES consensus development conference 2015. Surg Endosc. 2016;30:4668\u201390.","journal-title":"Surg Endosc"},{"key":"735_CR23","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1097\/SLE.0b013e3181f3f867","volume":"20","author":"TN Robinson","year":"2010","unstructured":"Robinson TN, Pavlovsky KR, Looney H, Stiegmann GV, McGreevy FT. Surgeon-controlled factors that reduce monopolar electrosurgery capacitive coupling during laparoscopy. Surg Laparosc Endosc Percutaneous Tech. 2010;20:317\u201320.","journal-title":"Surg Laparosc Endosc Percutaneous Tech"},{"key":"735_CR24","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.aorn.2016.01.003","volume":"103","author":"BC Ulmer","year":"2016","unstructured":"Ulmer BC. What is your energy IQ? FUSE: bridging a patient safety gap. AORN J. 2016;103:333\u20137. https:\/\/doi.org\/10.1016\/j.aorn.2016.01.003.","journal-title":"AORN J"},{"key":"735_CR25","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/S0002-9610(99)00267-6","volume":"179","author":"MP Wu","year":"2000","unstructured":"Wu MP, Ou CS, Chen SL, Yen EYT, Rowbotham R. Complications and recommended practices for electrosurgery in laparoscopy. Am J Surg. 2000;179:67\u201373.","journal-title":"Am J Surg"},{"key":"735_CR26","doi-asserted-by":"publisher","first-page":"4016","DOI":"10.1007\/s00464-013-3032-2","volume":"27","author":"EL Jones","year":"2013","unstructured":"Jones EL, Dunn CL, Townsend NT, Jones TS, Dunne JB, Montero PN, et al. Blend mode reduces unintended thermal injury by laparoscopic monopolar instruments: a randomized controlled trial. Surg Endosc. 2013;27:4016\u201320.","journal-title":"Surg Endosc"},{"key":"735_CR27","unstructured":"Wilson, MD, Nicole T Townsend, MD TNR. The Monopolar \u201cBovie\u201d Instrument: Pattern of Use Analysis - SAGES Abstract Archives. SAGES 2015 abstract archive. 2015. https:\/\/www.sages.org\/meetings\/annual-meeting\/abstracts-archive\/the-monopolar-bovie-instrument-pattern-of-use-analysis\/. Accessed 6 Mar 2019."},{"key":"735_CR28","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1159\/000493985","volume":"14","author":"A T\u00fcrkan","year":"2019","unstructured":"T\u00fcrkan A, Akkurt G, Yalaza M, De\u011firmencio\u011flu G, Kafadar MT, Yenid\u00fcnya S, et al. Effect of LigaSure\u2122, Monopolar cautery, and bipolar cautery on surgical margins in breast-conserving surgery. Breast Care (Basel). 2019;14:194\u20139. https:\/\/doi.org\/10.1159\/000493985.","journal-title":"Breast Care (Basel)"},{"key":"735_CR29","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1097\/SPV.0000000000000146","volume":"21","author":"CJ Iwanoff","year":"2015","unstructured":"Iwanoff CJ, Barbier HM, Massengill JC, Lombardini ED, Christensen CL, Buller JL, et al. Laparoscopic colpotomy using monopolar electrocautery: does power really matter? Female Pelvic Med Reconstr Surg. 2015;21:141\u20135. https:\/\/doi.org\/10.1097\/SPV.0000000000000146.","journal-title":"Female Pelvic Med Reconstr Surg"},{"key":"735_CR30","first-page":"96","volume":"145","author":"DJ Humes","year":"2010","unstructured":"Humes DJ, Ahmed I, Lobo DN. The pedicle effect and direct coupling. Arch Surg. 2010;145:96\u20138.","journal-title":"Arch Surg"},{"key":"735_CR31","doi-asserted-by":"publisher","first-page":"2313","DOI":"10.1089\/end.2008.9712","volume":"22","author":"A Mandhani","year":"2008","unstructured":"Mandhani A, Dorsey PJ Jr, Ramanathan R, Salamanca JI, Rao S, Leung R, et al. Real time monitoring of temperature changes in neurovascular bundles during robotic radical prostatectomy: thermal map for nerve-sparing radical prostatectomy. J Endourol. 2008;22:2313\u20138. https:\/\/doi.org\/10.1089\/end.2008.9712.","journal-title":"J Endourol"},{"key":"735_CR32","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1007\/978-3-319-19920-7_2","volume-title":"Fundamentals of Protein Structure and Function","author":"Engelbert Buxbaum","year":"2015","unstructured":"Buxbaum E. Fundamentals of protein structure and function, second edition. Springer, New York 2015."},{"key":"735_CR33","first-page":"223","volume":"1","author":"WB Saye","year":"1991","unstructured":"Saye WB, Miller W, Hertzmann P. Electrosurgery thermal injury. Myth or misconception? Surg Laparosc Endosc. 1991;1:223\u20138 http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/1669408. Accessed 9 Jan 2019.","journal-title":"Surg Laparosc Endosc"},{"key":"735_CR34","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1089\/end.2007.9908","volume":"21","author":"F Khan","year":"2007","unstructured":"Khan F, Rodriguez E, Finley DS, Skarecky DW, Ahlering TE. Spread of thermal energy and heat sinks: implications for nerve-sparing robotic prostatectomy. J Endourol. 2007;21:1195\u20138. https:\/\/doi.org\/10.1089\/end.2007.9908.","journal-title":"J Endourol"},{"key":"735_CR35","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/BF00315731","volume":"155","author":"RL Snipes","year":"1978","unstructured":"Snipes RL. Anatomy of the rabbit cecum. Anat Embryol (Berl). 1978;155:57\u201380 http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/727523. Accessed 14 Jan 2019.","journal-title":"Anat Embryol (Berl)"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-00735-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-020-00735-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-00735-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,24]],"date-time":"2022-10-24T22:51:23Z","timestamp":1666651883000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-020-00735-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,27]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["735"],"URL":"https:\/\/doi.org\/10.1186\/s12893-020-00735-6","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.19895\/v1","asserted-by":"object"}]},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,27]]},"assertion":[{"value":"3 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The present study was approved by the Institutional Animal Care and Use Committee at Pirogov Russian National Research Medical University (Moscow, Russian Federation, approval number 24\/2017). All animal experiments were performed in compliance with the NIH Guide for the Care and Use of Laboratory Animals.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Authors Taras Nechay, Svetlana Titkova, Mikhail Anurov, Elena Mikhalchik, Ekaterina Ivanova, Kirill Melnikov-Makarchyk, Alexander Tyagunov, Abe Fingerhut and Alexander Sazhin have no conflicts of interest or financial ties to disclose.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"116"}}