{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T22:53:41Z","timestamp":1773269621032,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T00:00:00Z","timestamp":1592524800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T00:00:00Z","timestamp":1592524800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>The concept of single-port laparoscopic percutaneous extraperitoneal closure for the treatment of inguinal hernias repair in children has been practising recent years. The applicable instruments and skills are still evolving. In this study, we used an epidural needle assisted by a towel forceps to practise this minimal invasive method for inguinal hernias repair in girls. Its safety and effectiveness were studied.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>From July 2008 to January 2020, thirty-five girls diagnosed of indirect inguinal hernias were studied retrospectively. From April 2017 to January 2020, the author was free to propose open or laparoscopic repair for the patients. The open group included twenty-four girls and the laparoscopic group included eleven. The data of the patients age, constituent ratios of sliding and bilateral hernias, operating time, postoperative time in hospital, follow-up time, conversion, postoperative complications were assessed.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>There were no statistically significant difference between the laparoscopic group and open group for the following items: age, operating time, postoperative time in hospital, the constituent ratios of sliding hernia and bilateral hernias (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). The follow-up time of the open group was longer than that of the laparoscopic group (<jats:italic>P<\/jats:italic>\u2009=\u20090.0004). One laparoscopic case was converted to open surgery. After 12 cases of laparoscopic practice, coordination of the hand and eye movements established well. There were no postoperative complications for all the patients.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>Our preliminary experience suggested that it is safe and convenient for inguinal hernias repair in girls by the single-port laparoscopic percutaneous extraperitoneal closure method using an epidural needle assisted by a towel forceps.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12893-020-00800-0","type":"journal-article","created":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T11:03:52Z","timestamp":1592564632000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Single-port laparoscopic percutaneous extraperitoneal closure for inguinal hernias repair in girls: using an epidural needle assisted by a towel forceps"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4948-6075","authenticated-orcid":false,"given":"Yuanhong","family":"Xiao","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,6,19]]},"reference":[{"issue":"6","key":"800_CR1","doi-asserted-by":"publisher","first-page":"1267","DOI":"10.1007\/s10029-019-01933-9","volume":"23","author":"H Yonggang","year":"2019","unstructured":"Yonggang H, Changfu Q, Ping W, Fangjie Z, Hao W, Zicheng G, et al. Single-port laparoscopic percutaneous extraperitoneal closure of inguinal hernia using \"two-hooked\" core needle apparatus in children. Hernia. 2019;23(6):1267\u201373. https:\/\/doi.org\/10.1007\/s10029-019-01933-9.","journal-title":"Hernia."},{"issue":"12","key":"800_CR2","doi-asserted-by":"publisher","first-page":"2507","DOI":"10.1016\/j.jpedsurg.2018.08.009","volume":"53","author":"S Li","year":"2018","unstructured":"Li S, Liu X, Wong KKY, Liu L, Li Y. Single-port laparoscopic herniorrhaphy using a two-hooked cannula device with hydrodissection. J Pediatr Surg. 2018;53(12):2507\u201310. https:\/\/doi.org\/10.1016\/j.jpedsurg.2018.08.009.","journal-title":"J Pediatr Surg"},{"issue":"5","key":"800_CR3","first-page":"427","volume":"23","author":"L Xu","year":"2017","unstructured":"Xu L, Li CQ, Chen XD, Qiu MJ, Jiang JH, Yao C, et al. Laparoscopic percutaneous extraperitoneal closure does not affect vas deferens orientation or testicular volume and perfusion. Zhonghua Nan Ke Xue. 2017;23(5):427\u201330.","journal-title":"Zhonghua Nan Ke Xue"},{"issue":"3","key":"800_CR4","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1089\/lap.2016.0223","volume":"28","author":"M Korkmaz","year":"2018","unstructured":"Korkmaz M, G\u00fcven\u00e7 BH. Comparison of single-port percutaneous Extraperitoneal repair and three-port mini-laparoscopic repair for pediatric inguinal hernia. J Laparoendosc Adv Surg Tech A. 2018;28(3):337\u201342. https:\/\/doi.org\/10.1089\/lap.2016.0223.","journal-title":"J Laparoendosc Adv Surg Tech A"},{"issue":"3","key":"800_CR5","doi-asserted-by":"publisher","first-page":"170.e1","DOI":"10.1016\/j.jpurol.2015.11.006","volume":"12","author":"C Li","year":"2016","unstructured":"Li C, Xu L, Peng Y, Liang X, Lin W. Effects of single-port laparoscopic percutaneous extraperitoneal closure on the orientation of the vas deferens and testicular perfusion and volume: Experience from a single center. J Pediatr Urol. 2016;12(3):170.e1\u20135. https:\/\/doi.org\/10.1016\/j.jpurol.2015.11.006.","journal-title":"J Pediatr Urol"},{"issue":"5","key":"800_CR6","doi-asserted-by":"publisher","first-page":"262.e1","DOI":"10.1016\/j.jpurol.2015.04.008","volume":"11","author":"MD Timberlake","year":"2015","unstructured":"Timberlake MD, Sukhu HKW, Rasmussen S, Corbett ST. Laparoscopic percutaneous inguinal hernia repair in children: review of technique and comparison with open surgery. J Pediatr Urol. 2015;11(5):262.e1\u20136. https:\/\/doi.org\/10.1016\/j.jpurol.2015.04.008.","journal-title":"J Pediatr Urol"},{"issue":"7","key":"800_CR7","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1007\/s00383-015-3722-z","volume":"31","author":"E Yilmaz","year":"2015","unstructured":"Yilmaz E, Afsarlar CE, Senel E, Cavusoglu YH, Karaman I, Karaman A, et al. A novel technique for laparoscopic inguinal hernia repair in children: single-port laparoscopic percutaneous extraperitoneal closure assisted by an optical forceps. Pediatr Surg Int. 2015;31(7):639\u201346. https:\/\/doi.org\/10.1007\/s00383-015-3722-z.","journal-title":"Pediatr Surg Int"},{"issue":"12","key":"800_CR8","doi-asserted-by":"publisher","first-page":"1818","DOI":"10.1016\/j.jpedsurg.2014.09.027","volume":"49","author":"S Li","year":"2014","unstructured":"Li S, Li M, Wong KK, Liu L, Tam PK. Laparoscopically assisted simple suturing obliteration (LASSO) of the internal ring using an epidural needle: a handy single-port laparoscopic herniorrhaphy in children. J Pediatr Surg. 2014;49(12):1818\u201320. https:\/\/doi.org\/10.1016\/j.jpedsurg.2014.09.027.","journal-title":"J Pediatr Surg"},{"issue":"4","key":"800_CR9","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1007\/s00464-014-3739-8","volume":"29","author":"L McClain","year":"2015","unstructured":"McClain L, Streck C, Lesher A, Cina R, Hebra A. Laparoscopic needle-assisted inguinal hernia repair in 495 children. Surg Endosc. 2015;29(4):781\u20136. https:\/\/doi.org\/10.1007\/s00464-014-3739-8.","journal-title":"Surg Endosc"},{"issue":"3","key":"800_CR10","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1007\/s10029-013-1181-9","volume":"18","author":"W Liu","year":"2014","unstructured":"Liu W, Wu R, Du G. Single-port laparoscopic extraperitoneal repair of pediatric inguinal hernias and hydroceles by using modified Kirschner pin: a novel technique. Hernia. 2014;18(3):345\u20139. https:\/\/doi.org\/10.1007\/s10029-013-1181-9.","journal-title":"Hernia."},{"issue":"6","key":"800_CR11","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1097\/SLE.0b013e3182680842","volume":"22","author":"YT Chang","year":"2012","unstructured":"Chang YT, Lin JY, Lee JY, Tsai CJ, Chiu WC, Chiu CS. Comparative mid-term results between inguinal herniotomy and single-port laparoscopic herniorrhaphy for pediatric inguinal hernia. Surg Laparosc Endosc Percutan Tech. 2012;22(6):526\u201331. https:\/\/doi.org\/10.1097\/SLE.0b013e3182680842.","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"800_CR12","first-page":"66","volume-title":"Medical Statistics and CHISS Application","author":"G Li","year":"2006","unstructured":"Li G, Wang HW. Matched Pairs Design Comparison. In: Tong XY, Wang HY, Guo XH, editors. Medical Statistics and CHISS Application. Beijing: People\u2019s Military Medical Press; 2006. p. 66\u201385. 100036 Post Box 188 Sub Box."},{"key":"800_CR13","first-page":"1053","volume-title":"Surgery of infants and children: scientific principles and practice","author":"GW Holcomb III","year":"1997","unstructured":"Holcomb GW III. Clinical principles of abdominal surgery. In: Oldham KT, Colombani PM, Foglia RP, editors. Surgery of infants and children: scientific principles and practice. Philadelphia New York: Lippincott-Raven Publishers, 227 East Washington Square, PA 19106\u20133780; 1997. p. 1053."},{"issue":"8","key":"800_CR14","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1111\/iju.13371","volume":"24","author":"S Yoshida","year":"2017","unstructured":"Yoshida S, Fukuyo T, Saito K, Kihara K, Fujii Y. Real-time three-dimensional image angle rectification to improve hand-eye coordination in single-port laparoendoscopic surgery. Int J Urol. 2017;24(8):639\u201340. https:\/\/doi.org\/10.1111\/iju.13371.","journal-title":"Int J Urol"},{"issue":"10","key":"800_CR15","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1111\/j.1477-2574.2010.00244.x","volume":"12","author":"D Sindram","year":"2010","unstructured":"Sindram D, IH MK, Martinie JB, Iannitti DA. Novel 3-D laparoscopic magnetic ultrasound image guidance for lesion targeting. HPB-(Oxford). 2010;12(10):709\u201316. https:\/\/doi.org\/10.1111\/j.1477-2574.2010.00244.x.","journal-title":"HPB-(Oxford)"},{"issue":"8","key":"800_CR16","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1089\/end.2011.0670","volume":"26","author":"P Honeck","year":"2012","unstructured":"Honeck P, Wendt Nordahl G, Rassweiler J, Knoll T. Three-dimensional laparoscopic imaging improves surgical performance on standardized ex-vivo laparoscopic tasks. J Endourol. 2012;26(8):1085\u20138. https:\/\/doi.org\/10.1089\/end.2011.0670.","journal-title":"J Endourol"},{"issue":"2","key":"800_CR17","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1089\/end.2013.0344","volume":"28","author":"A Lusch","year":"2014","unstructured":"Lusch A, Bucur PL, Menhadji AD, Okhunov Z, Liss MA, Perez-Lanzac A, et al. Evaluation of the impact of three-dimensional vision on laparoscopic performance. J Endourol. 2014;28(2):261\u20136. https:\/\/doi.org\/10.1089\/end.2013.0344.","journal-title":"J Endourol"},{"issue":"12","key":"800_CR18","doi-asserted-by":"publisher","first-page":"3489","DOI":"10.1007\/s00464-014-3635-2","volume":"28","author":"R Mashiach","year":"2014","unstructured":"Mashiach R, Mezhybovsky V, Nevler A, Gutman M, Ziv A, Khaikin M. Three-dimensional imaging improves surgical skill performance in a laparoscopic test model for both experienced and novice laparoscopic surgeons. Surg Endosc. 2014;28(12):3489\u201393. https:\/\/doi.org\/10.1007\/s00464-014-3635-2.","journal-title":"Surg Endosc"},{"issue":"11","key":"800_CR19","doi-asserted-by":"publisher","first-page":"4224","DOI":"10.1007\/s00464-013-3027-z","volume":"27","author":"KK Middleton","year":"2013","unstructured":"Middleton KK, Hamilton T, Tsai PC, Middleton DB, Falcone JL, Hamad G. Improved nondominant hand performance on a laparoscopic virtual reality simulator after playing the Nintendo Wii. Surg Endosc. 2013;27(11):4224\u201331. https:\/\/doi.org\/10.1007\/s00464-013-3027-z.","journal-title":"Surg Endosc"},{"issue":"5","key":"800_CR20","doi-asserted-by":"publisher","first-page":"745","DOI":"10.7507\/1001-5515.201605035","volume":"34","author":"M Xu","year":"2017","unstructured":"Xu M, Shuyi W, Shasha Y. Study on method of laparoscopic training based on eye gaze tracking techniques. J Biomed Eng. 2017;34(5):745\u201351. https:\/\/doi.org\/10.7507\/1001-5515.201605035.","journal-title":"J Biomed Eng"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-00800-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-020-00800-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-00800-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,18]],"date-time":"2021-06-18T23:36:23Z","timestamp":1624059383000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-020-00800-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,19]]},"references-count":20,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["800"],"URL":"https:\/\/doi.org\/10.1186\/s12893-020-00800-0","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,19]]},"assertion":[{"value":"1 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This article has been approved by the Medical Ethical Committee of Chinese PLA General Hospital. We confirm that the parents of all patients have given their parental consents for this study in verbal. In our hospital, there is not a routine written form of consent to participate in the accompanying scientifc reaserch during routine clinical activities, however, if the accompanying scientific reaserch is not related to the patients confidential informations like in this study, it is assured to be allowable by the parents and the ethical committee of our hospital.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All the parents of involved children have signed the Informed Content Form before surgery. In this study, there is no any indentifying personal or clinical details along with any indentifying images to be published.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The author declares that no competing interests exist.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"139"}}