{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T10:56:12Z","timestamp":1740135372907,"version":"3.37.3"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,29]],"date-time":"2021-03-29T00:00:00Z","timestamp":1616976000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,3,29]],"date-time":"2021-03-29T00:00:00Z","timestamp":1616976000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the Health Department of Jilin Province","award":["3D5172173429"],"award-info":[{"award-number":["3D5172173429"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>With the continuous improvement of surgical instruments in vitrectomy, the use of a trocar and cannula not only optimizes the incision process but also facilitates insertion and withdrawal of instruments during the procedure. Nevertheless, incision-related complications have also been reported in the literature. However, cannula fractures during 25G+ minimally invasive vitrectomy have rarely been reported.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 62-year-old man underwent 25G+ pars plana vitrectomy for proliferative diabetic retinopathy. At the beginning of the operation, we used a trocar with a cannula to perform the sclerotomy. After the trocar was pulled out, the cannula was not seen on the surface of the sclera. Thus the inside and outside of the eye were carefully searched. The broken cannula tip was found in the ciliary body corresponding to the superonasal sclerotomy site and was subsequently removed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Awareness regarding the risk of intraoperative fractures of 25G+ minimally invasive ocular surgical instruments is imperative. Whenever a broken or missing cannula is encountered, the residual part should be immediately extracted to avoid revision surgeries and postoperative complications.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12893-020-01001-5","type":"journal-article","created":{"date-parts":[[2021,3,29]],"date-time":"2021-03-29T13:03:24Z","timestamp":1617023004000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cannula breakage during 25G+ minimally invasive vitrectomy: a case report"],"prefix":"10.1186","volume":"21","author":[{"given":"Zhimin","family":"Shu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siyan","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenli","family":"Shan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linlin","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ning","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1904-1174","authenticated-orcid":false,"given":"Jinsong","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,3,29]]},"reference":[{"key":"1001_CR1","first-page":"813","volume":"75","author":"R Machemer","year":"1971","unstructured":"Machemer R, Buettner H, Norton EW, et al. Vitrectomy: a pars plana approach. Trans Am AcadOphthalmolOtolaryngol. 1971;75:813\u201320.","journal-title":"Trans Am AcadOphthalmolOtolaryngol"},{"issue":"585\u20138","key":"1001_CR2","first-page":"591","volume":"7","author":"C O'Malley","year":"1975","unstructured":"O\u2019Malley C, Heintz RM Sr. Vitrectomy with an alternative instrument system. Ann Ophthalmol. 1975;7(585\u20138):591\u20134.","journal-title":"Ann Ophthalmol"},{"key":"1001_CR3","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1016\/S0161-6420(02)01179-X","volume":"109","author":"GY Fujii","year":"2002","unstructured":"Fujii GY, De Juan Jr E, Humayun MS, et al. A new 25-gauge instrument system for transconjunctivalsuturelessvitrectomy surgery. Ophthalmology. 2002;109:1807\u201313.","journal-title":"Ophthalmology"},{"key":"1001_CR4","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1097\/00006982-200502000-00015","volume":"25","author":"C Eckardt","year":"2005","unstructured":"Eckardt C. Transconjunctivalsutureless 23-gauge vitrectomy. Retina. 2005;25:208\u201311.","journal-title":"Retina"},{"issue":"93\u2013102","key":"1001_CR5","first-page":"e2","volume":"117","author":"Y Oshima","year":"2010","unstructured":"Oshima Y, Wakabayashi T, Sato T, et al. A 27-gauge instrument system for transconjunctivalsuturelessmicroincisionvitrectomy surgery. Ophthalmology. 2010;117(93\u2013102):e2.","journal-title":"Ophthalmology"},{"key":"1001_CR6","doi-asserted-by":"publisher","first-page":"323","DOI":"10.3928\/15428877-20080701-02","volume":"39","author":"CJ Chen","year":"2008","unstructured":"Chen CJ, Satofuka S, Inoue M, et al. Suprachoroidalhemorrhage caused by breakage of a 25-gauge cannula. Ophthalmic Surg Lasers Imaging. 2008;39:323\u20134.","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"1001_CR7","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1097\/ICB.0000000000000153","volume":"9","author":"RW Wong","year":"2015","unstructured":"Wong RW. Bacterial endophthalmitis associated with a broken and retained small-gauge vitrectomy cannula. Retin Cases Brief Rep. 2015;9:256\u20138.","journal-title":"Retin Cases Brief Rep"},{"key":"1001_CR8","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1016\/j.ajo.2004.05.035","volume":"138","author":"M Inoue","year":"2004","unstructured":"Inoue M, Noda K, Ishida S, et al. Intraoperative breakage of a 25-gauge vitreous cutter. Am J Ophthalmol. 2004;138:867\u20139.","journal-title":"Am J Ophthalmol"},{"key":"1001_CR9","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.ajo.2005.08.017","volume":"141","author":"KU Bartz-Schmidt","year":"2006","unstructured":"Bartz-Schmidt KU, El-Araj I, Gelisken F, et al. Intraoperative breakage of 20-gauge Tano forceps. Am J Ophthalmol. 2006;141:215\u20137.","journal-title":"Am J Ophthalmol"},{"key":"1001_CR10","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1097\/ICB.0b013e3182618d85","volume":"7","author":"JD Udoetuk","year":"2013","unstructured":"Udoetuk JD, Javey G, Carvounis PE. Intraoperative breakage of a disposable 23-gauge trocar tip. Retin Cases Brief Rep. 2013;7:50\u20131.","journal-title":"Retin Cases Brief Rep"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-01001-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12893-020-01001-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-01001-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,29]],"date-time":"2021-03-29T13:04:03Z","timestamp":1617023043000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-020-01001-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,29]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1001"],"URL":"https:\/\/doi.org\/10.1186\/s12893-020-01001-5","relation":{},"ISSN":["1471-2482"],"issn-type":[{"type":"electronic","value":"1471-2482"}],"subject":[],"published":{"date-parts":[[2021,3,29]]},"assertion":[{"value":"30 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This case report was approved by the institutional ethical committee in Jilin University Second Hospital, and written informed consent was obtained from the patient.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"169"}}