{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T14:58:44Z","timestamp":1767970724482,"version":"3.49.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,1,17]],"date-time":"2020-01-17T00:00:00Z","timestamp":1579219200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,1,17]],"date-time":"2020-01-17T00:00:00Z","timestamp":1579219200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Iatrogenic aortic stenosis is a serious complication and potentially fatal due to erosion of the aortic wall. Timely management is necessary to prevent complications.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Case presentation<\/jats:title>\n<jats:p>A 2-year-old boy underwent surgery to remove part of an Amplatzer occluder after patent ductus arteriosus (PDA) device embolization in the thoracic aorta. He exhibited moderate to severe obstruction with erosion of the intimal layer of the aorta caused by the device, part of which was retrieved surgically with restructuring of the thoracic aorta segment and occluder remnant. The patient\u2019s postoperative course was uneventful.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>When possible, retrieving only part of an embolized device can be advocated because it reduces the risk of aortic and pulmonary artery damage.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12893-020-0682-6","type":"journal-article","created":{"date-parts":[[2020,1,17]],"date-time":"2020-01-17T14:02:50Z","timestamp":1579269770000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Surgical removal of part of an occluder to treat iatrogenic coarctation of the aorta: a case report"],"prefix":"10.1186","volume":"20","author":[{"given":"Zhongwei","family":"Sun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dongxu","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yabo","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"An","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,1,17]]},"reference":[{"key":"682_CR1","doi-asserted-by":"publisher","first-page":"974","DOI":"10.12669\/pjms.324.10048","volume":"32","author":"A Zulqarnain","year":"2016","unstructured":"Zulqarnain A, Younas M, Waqar T, Beg A, Asma T, Baig MA. Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus. Pak J Med Sci. 2016;32:974\u20137.","journal-title":"Pak J Med Sci"},{"key":"682_CR2","doi-asserted-by":"crossref","unstructured":"Backes CH, Rivera BK, Bridge JA, Armstrong AK, Boe BA, Berman DP, et al. Percutaneous patent Ductus Arteriosus (PDA) closure during infancy: a meta-analysis. Congenit Heart Dis. 2017;139.","DOI":"10.1542\/peds.2016-2927"},{"key":"682_CR3","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1161\/CIRCULATIONAHA.105.592063","volume":"114","author":"DJ Schneider","year":"2006","unstructured":"Schneider DJ, Moore JW. Patent ductus arteriosus. Circulation. 2006;114:1873\u201382.","journal-title":"Circulation"},{"key":"682_CR4","doi-asserted-by":"crossref","unstructured":"Shepherd JL, Noori S. What is a hemodynamically significant PDA in preterm infants? 2019;14:21\u20136.","DOI":"10.1111\/chd.12727"},{"key":"682_CR5","doi-asserted-by":"publisher","first-page":"670","DOI":"10.1093\/oxfordjournals.eurheartj.a059775","volume":"11","author":"SH Sardesai","year":"1990","unstructured":"Sardesai SH, Marshall RJ, Farrow R, Mourant AJ. Dissecting aneurysm of the pulmonary artery in a case of unoperated patent ductus arteriosus. Eur Heart J. 1990;11:670\u20133.","journal-title":"Eur Heart J"},{"key":"682_CR6","first-page":"e409","volume":"131","author":"JJ Ryan","year":"2015","unstructured":"Ryan JJ, Suksaranjit P, Hatton N, Bull DA, Wilson BD. Eisenmenger syndrome with unrepaired patent ductus arteriosus. Circulation. 2015;131:e409\u201311.","journal-title":"Circulation"},{"key":"682_CR7","doi-asserted-by":"publisher","first-page":"1927","DOI":"10.1016\/j.ehj.2004.07.037","volume":"25","author":"AM Soares","year":"2004","unstructured":"Soares AM, Aiello VD, Andrade JL, Kajita LJ, Soares J Jr, Morhy SS, et al. Doppler flow evaluation can anticipate abnormal left lung perfusion after transcatheter closure of patent ductus arteriosus. Eur Heart J. 2004;25:1927\u201333.","journal-title":"Eur Heart J"},{"key":"682_CR8","doi-asserted-by":"publisher","first-page":"e5","DOI":"10.1016\/j.jcin.2018.10.057","volume":"12","author":"H Yamamoto","year":"2019","unstructured":"Yamamoto H, Otake H, Akagi T, Matsumoto K, Henmi S, Inoue T, et al. Acute aortic dissection as a rare complication of percutaneous closure using the Amplatzer vascular plug II for a tubular and enlarged patent Ductus Arteriosus in an elderly patient. JACC Cardiovasc Interv. 2019;12:e5\u20137.","journal-title":"JACC Cardiovasc Interv"},{"key":"682_CR9","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1016\/j.jcin.2011.05.021","volume":"4","author":"L Bergersen","year":"2011","unstructured":"Bergersen L, Gauvreau K, Foerster SR, Marshall AC, McElhinney DB, Beekman RH 3rd, et al. Catheterization for congenital heart disease adjustment for risk method (CHARM). JACC Cardiovasc Interv. 2011;4:1037\u201346.","journal-title":"JACC Cardiovasc Interv"},{"key":"682_CR10","doi-asserted-by":"publisher","first-page":"1729","DOI":"10.1016\/j.jcin.2017.05.018","volume":"10","author":"CH Backes","year":"2017","unstructured":"Backes CH, Kennedy KF, Locke M, Cua CL, Ball MK, Fick TA, et al. Transcatheter Occlusion of the Patent Ductus Arteriosus in 747 Infants &lt;6 kg: Insights From the NCDR IMPACT Registry. JACC Cardiovasc Interv. 2017;10:1729\u201337.","journal-title":"JACC Cardiovasc Interv"},{"key":"682_CR11","doi-asserted-by":"publisher","first-page":"106","DOI":"10.4068\/cmj.2015.51.2.106","volume":"51","author":"YS Kim","year":"2015","unstructured":"Kim YS, Lee SR. Percutaneous forceps retrieval of an Embolized Amplatzer duct Occluder. Chonnam Med J. 2015;51:106\u20138.","journal-title":"Chonnam Med J"},{"key":"682_CR12","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1016\/j.jsha.2015.11.002","volume":"28","author":"MA Khan","year":"2016","unstructured":"Khan MA, Almashham YH, Almoukirish AR, Momenah TS. Embolized amplatzer duct occluder to aorta: retrieval technique. J Saudi Heart Assoc. 2016;28:116\u20138.","journal-title":"J Saudi Heart Assoc"},{"key":"682_CR13","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1177\/1538574418823384","volume":"53","author":"S Barutcu","year":"2019","unstructured":"Barutcu S, Alizade E, Pala S. Successful percutaneous treatment of an Embolized patent Ductus Arteriosus Occluder device. Vasc Endovasc Surg. 2019;53:264\u20136.","journal-title":"Vasc Endovasc Surg"},{"key":"682_CR14","doi-asserted-by":"crossref","unstructured":"Epcacan S, Bulut MO. A beneficial technique for preventing the device protrusion to the aorta during percutaneous patent ductus arteriosus closure: \u201cBalloon-assisted device releasing technique\u201d. 2019;29:1380\u20136.","DOI":"10.1017\/S1047951119002269"},{"key":"682_CR15","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.jccase.2018.12.002","volume":"19","author":"H Yamamoto","year":"2019","unstructured":"Yamamoto H, Shinke T, Otake H, Tanaka H, Matsumoto K, Hirata KI. Acute ascending aortic dissection due to transcatheter patent ductus arteriosus closure in the elderly: an extremely rare complication of transcatheter patent ductus arteriosus closure. J Cardiol Cases. 2019;19:85\u20138.","journal-title":"J Cardiol Cases"},{"key":"682_CR16","first-page":"44","volume":"11","author":"I Haponiuk","year":"2016","unstructured":"Haponiuk I, Paczkowski K, Chojnicki M, Jaworski R. Iatrogenic obstruction of the aorta - a sequence of delayed, fatal complications after 'off-label' interventional persistent ductus arteriosus closure. Wideochir Inne Tech Maloinwazyjne. 2016;11:44\u20138.","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"682_CR17","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1007\/s00246-012-0272-1","volume":"33","author":"RR Tripathi","year":"2012","unstructured":"Tripathi RR, Agarwal R, Premsekar R. Late surgical removal of an embolized patent ductus arteriosus device causing erosion of the aortic wall. Pediatr Cardiol. 2012;33:1453\u20135.","journal-title":"Pediatr Cardiol"},{"key":"682_CR18","doi-asserted-by":"crossref","unstructured":"Schleimer K, Jalaie H, Afify M, Woitok A, Barbati ME, Hoeft K, et al. Sheep models for evaluation of novel patch and prosthesis material in vascular surgery: tips and tricks to avoid possible pitfalls. 2018,60:42.","DOI":"10.1186\/s13028-018-0397-1"},{"key":"682_CR19","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/1471-2482-11-37","volume":"11","author":"WF Saporito","year":"2011","unstructured":"Saporito WF, Pires AC, Cardoso SH, Correa JA, de Abreu LC, Valenti VE, et al. Bovine pericardium retail preserved in glutaraldehyde and used as a vascular patch. BMC Surg. 2011;11:37.","journal-title":"BMC Surg"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-0682-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12893-020-0682-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-020-0682-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,16]],"date-time":"2021-01-16T00:11:16Z","timestamp":1610755876000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-020-0682-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,17]]},"references-count":19,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["682"],"URL":"https:\/\/doi.org\/10.1186\/s12893-020-0682-6","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,17]]},"assertion":[{"value":"7 November 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient\u2019s parent for publication of this case report and any accompanying images. A copy of the written consent is available for review by the editor of this journal.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"17"}}