{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T13:48:17Z","timestamp":1768916897388,"version":"3.49.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T00:00:00Z","timestamp":1620086400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T00:00:00Z","timestamp":1620086400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"The 13th Five-year Plan for Key Discipline Construction Project of PLA","award":["A350109"],"award-info":[{"award-number":["A350109"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The treatment of a displaced proximal humeral fracture is still a matter of controversy. The purpose of this study was to report outcomes at a long-term follow-up after fixation augmentation using peek (polyether-ether-ketone) cage and locking compression plate (LCP).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A total of 27 patients (average age 53.8\u00a0years, range 19\u201386\u00a0years) were treated with peek cage and LCP. All of them had a minimum radiographic and clinical follow-up of 1\u00a0years. Outcomes were assessed using the Constant-Murley score (CMS), disability of the arm, shoulder and hand (DASH) score. Complications were also recorded during follow-up.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The average follow-up was 28\u00a0months (range 12\u201348\u00a0months). The mean functional outcomes were as follows: CMS, 73.3 (range 61\u201386); DASH, 45.9 (range 27\u201368). A total of 4 patients had complications: osteonecrosis developed in one patient, loss of reduction was observed in 1 patient and stiffness was occurred in two patients.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The use of peek cage and LCP has been a valuable option in the treatment of proximal humeral fractures. The complication rate was acceptable. Suitable void filler in the proximal humerus for reconstructing the medial column integrity attains mechanical stability in reducing the incidence of the complications.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12893-021-01235-x","type":"journal-article","created":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T05:03:01Z","timestamp":1620104581000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Stable osteosynthesis of cage in cage technique for surgical treatment of proximal humeral fractures"],"prefix":"10.1186","volume":"21","author":[{"given":"Jiantao","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caixia","family":"Yin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaobo","family":"Nie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hui","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenliang","family":"Quan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hua","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,5,4]]},"reference":[{"issue":"8","key":"1235_CR1","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","volume":"37","author":"CM Court-Brown","year":"2006","unstructured":"Court-Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury. 2006;37(8):691\u20137.","journal-title":"Injury"},{"issue":"3","key":"1235_CR2","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1002\/acr.21563","volume":"64","author":"SH Kim","year":"2012","unstructured":"Kim SH, Szabo RM, Marder RA. Epidemiology of humerus fractures in the United States: nationwide emergency department sample, 2008. Arthritis Care Res. 2012;64(3):407\u201314.","journal-title":"Arthritis Care Res"},{"issue":"2","key":"1235_CR3","doi-asserted-by":"publisher","first-page":"233","DOI":"10.2106\/JBJS.F.01351","volume":"90","author":"KC Owsley","year":"2008","unstructured":"Owsley KC, Gorczyca JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Joint Surg Am. 2008;90(2):233\u201340.","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"1235_CR4","doi-asserted-by":"publisher","first-page":"233","DOI":"10.2106\/JBJS.F.01351","volume":"90","author":"JT Gorczyca","year":"2008","unstructured":"Gorczyca JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. J Bone Joint Surg. 2008;90(2):233.","journal-title":"J Bone Joint Surg"},{"issue":"2","key":"1235_CR5","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.injury.2011.04.003","volume":"43","author":"F Hardeman","year":"2012","unstructured":"Hardeman F, Bollars P, Donnelly M, Bellemans J, Nijs S. Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus. Injury. 2012;43(2):153\u20138.","journal-title":"Injury"},{"issue":"3","key":"1235_CR6","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","volume":"21","author":"MJ Gardner","year":"2007","unstructured":"Gardner MJ, Weil Y, Barker JU, Kelly BT, Helfet DL, Lorich DG. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21(3):185\u201391.","journal-title":"J Orthop Trauma"},{"issue":"9","key":"1235_CR7","doi-asserted-by":"publisher","first-page":"e822","DOI":"10.3928\/01477447-20140825-60","volume":"37","author":"E Tan","year":"2014","unstructured":"Tan E, Lie D, Wong M. Early outcomes of proximal humerus fracture fixation with locking plate and intramedullary fibular strut graft. Orthopedics. 2014;37(9):e822\u20137.","journal-title":"Orthopedics"},{"issue":"11","key":"1235_CR8","doi-asserted-by":"publisher","first-page":"1939","DOI":"10.1016\/j.injury.2012.08.004","volume":"43","author":"F Matassi","year":"2012","unstructured":"Matassi F, Angeloni R, Carulli C, Civinini R, Di Bella L, Redl B, Innocenti M. Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus. Injury. 2012;43(11):1939\u201342.","journal-title":"Injury"},{"key":"1235_CR9","doi-asserted-by":"crossref","unstructured":"He Y, He J, Wang F, Zhou D, Wang Y, Wang B, Xu S. Application of additional medial plate in treatment of proximal humeral fractures with unstable medial column: a finite element study and clinical practice. Medicine. 2015; 94(41).","DOI":"10.1097\/MD.0000000000001775"},{"key":"1235_CR10","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.ijsu.2018.10.031","volume":"60","author":"RA Agha","year":"2018","unstructured":"Agha RA, Borrelli MR, Farwana R, Koshy K, Fowler AJ, Orgill DP. The PROCESS 2018 statement: updating consensus preferred reporting Of CasE series in surgery (PROCESS) guidelines. Int J Surg. 2018;60:279\u201382.","journal-title":"Int J Surg"},{"issue":"10","key":"1235_CR11","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1097\/BOT.0b013e31815bb09d","volume":"21","author":"J Agudelo","year":"2007","unstructured":"Agudelo J, Sch\u00fcrmann M, Stahel P, Helwig P, Morgan SJ, Zechel W, Bahrs C, Parekh A, Ziran B, Williams A, et al. Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma. 2007;21(10):676\u201381.","journal-title":"J Orthop Trauma"},{"key":"1235_CR12","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1186\/1471-2474-14-102","volume":"14","author":"WB Jung","year":"2013","unstructured":"Jung WB, Moon ES, Kim SK, Kovacevic D, Kim MS. Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate? BMC Musculoskelet Disord. 2013;14:102.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"1235_CR13","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","volume":"42","author":"RC Sproul","year":"2011","unstructured":"Sproul RC, Iyengar JJ, Devcic Z, Feeley BT. A systematic review of locking plate fixation of proximal humerus fractures. Injury. 2011;42(4):408\u201313.","journal-title":"Injury"},{"issue":"4","key":"1235_CR14","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1097\/00005131-200604000-00004","volume":"20","author":"RA Meier","year":"2006","unstructured":"Meier RA, Messmer P, Regazzoni P, Rothfischer W, Gross T. Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade plate. J Orthop Trauma. 2006;20(4):253\u201360.","journal-title":"J Orthop Trauma"},{"key":"1235_CR15","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1097\/01.blo.0000137554.91189.a9","volume":"430","author":"F Fankhauser","year":"2005","unstructured":"Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 2005;430:176\u201381.","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"1235_CR16","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","volume":"42","author":"D Krappinger","year":"2011","unstructured":"Krappinger D, Bizzotto N, Riedmann S, Kammerlander C, Hengg C, Kralinger FS. Predicting failure after surgical fixation of proximal humerus fractures. Injury. 2011;42(11):1283\u20138.","journal-title":"Injury"},{"key":"1235_CR17","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1186\/1749-799X-6-50","volume":"6","author":"G Osterhoff","year":"2011","unstructured":"Osterhoff G, Ossendorf C, Wanner GA, Simmen HP, Werner CM. The calcar screw in angular stable plate fixation of proximal humeral fractures\u2013a case study. J Orthop Surg Res. 2011;6:50.","journal-title":"J Orthop Surg Res"},{"issue":"8","key":"1235_CR18","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1097\/BOT.0000000000000057","volume":"28","author":"L Bai","year":"2014","unstructured":"Bai L, Fu Z, An S, Zhang P, Zhang D, Jiang B. Effect of calcar screw use in surgical neck fractures of the proximal humerus with unstable medial support: a biomechanical study. J Orthop Trauma. 2014;28(8):452\u20137.","journal-title":"J Orthop Trauma"},{"key":"1235_CR19","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1097\/00003086-199706000-00011","volume":"339","author":"JA Goulet","year":"1997","unstructured":"Goulet JA, Senunas LE, DeSilva GL, Greenfield ML. Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop Relat Res. 1997;339:76\u201381.","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"1235_CR20","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.3760\/cma.j.issn.0366-6999.20133104","volume":"127","author":"L Zhu","year":"2014","unstructured":"Zhu L, Liu Y, Yang Z, Li H, Wang J, Zhao C, Chen X, Zhang Y. Locking plate fixation combined with iliac crest bone autologous graft for proximal humerus comminuted fracture. Chin Med J. 2014;127(9):1672\u20136.","journal-title":"Chin Med J"},{"issue":"41","key":"1235_CR21","doi-asserted-by":"publisher","first-page":"e1775","DOI":"10.1097\/MD.0000000000001775","volume":"94","author":"Y He","year":"2015","unstructured":"He Y, He J, Wang F, Zhou D, Wang Y, Wang B, Xu S. Application of additional medial plate in treatment of proximal humeral fractures with unstable medial column: a finite element study and clinical practice. Medicine (Baltimore). 2015;94(41):e1775.","journal-title":"Medicine (Baltimore)"},{"issue":"3","key":"1235_CR22","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1097\/BOT.0b013e31815b3922","volume":"22","author":"MJ Gardner","year":"2008","unstructured":"Gardner MJ, Boraiah S, Helfet DL, Lorich DG. Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant. J Orthop Trauma. 2008;22(3):195\u2013200.","journal-title":"J Orthop Trauma"},{"key":"1235_CR23","first-page":"3130625","volume":"2018","author":"H Chen","year":"2018","unstructured":"Chen H, Yin P, Wang S, Li J, Zhang L, Khan K, Zhang L, Tang P. The augment of the stability in locking compression plate with intramedullary fibular allograft for proximal humerus fractures in elderly people. BioMed Res Int. 2018;2018:3130625.","journal-title":"BioMed Res Int"},{"issue":"12","key":"1235_CR24","doi-asserted-by":"publisher","first-page":"3300","DOI":"10.1007\/s11999-011-1949-0","volume":"469","author":"AS Neviaser","year":"2011","unstructured":"Neviaser AS, Hettrich CM, Beamer BS, Dines JS, Lorich DG. Endosteal strut augment reduces complications associated with proximal humeral locking plates. Clin Orthop Relat Res. 2011;469(12):3300\u20136.","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"1235_CR25","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1016\/j.jse.2014.10.019","volume":"24","author":"RM Hinds","year":"2015","unstructured":"Hinds RM, Garner MR, Tran WH, Lazaro LE, Dines JS, Lorich DG. Geriatric proximal humeral fracture patients show similar clinical outcomes to non-geriatric patients after osteosynthesis with endosteal fibular strut allograft augmentation. J Shoulder Elbow Surg. 2015;24(6):889\u201396.","journal-title":"J Shoulder Elbow Surg"},{"issue":"3","key":"1235_CR26","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.jse.2012.04.010","volume":"22","author":"R Russo","year":"2013","unstructured":"Russo R, Cautiero F, Ciccarelli M, Vernaglia Lombardi L. Reconstruction of unstable, complex proximal humeral fractures with the da Vinci cage: surgical technique and outcome at 2 to 6 years. J Shoulder Elbow Surg. 2013;22(3):422\u201331.","journal-title":"J Shoulder Elbow Surg"},{"issue":"Suppl 3","key":"1235_CR27","doi-asserted-by":"publisher","first-page":"S12","DOI":"10.1016\/S0020-1383(17)30651-4","volume":"48","author":"R Russo","year":"2017","unstructured":"Russo R, D\u2019Auria D, Ciccarelli M, Della Rotonda G, D\u2019Elia G, Siciliano B. Triangular block bridge method for surgical treatment of complex proximal humeral fractures: theoretical concept, surgical technique and clinical results. Injury. 2017;48(Suppl 3):S12-s19.","journal-title":"Injury"},{"issue":"9","key":"1235_CR28","doi-asserted-by":"publisher","first-page":"1843","DOI":"10.1016\/j.jse.2020.01.077","volume":"29","author":"G Della Rotonda","year":"2020","unstructured":"Della Rotonda G, Guastafierro A, Viglione S, Russo F, Coscione AV, Ciccarelli M, Russo R. Analysis of early and late clinical and radiologic complications of proximal humeral fractures using open reduction, internal fixation, and intramedullary titanium cage augmentation. J Shoulder Elbow Surg. 2020;29(9):1843\u201351.","journal-title":"J Shoulder Elbow Surg"},{"issue":"18","key":"1235_CR29","doi-asserted-by":"publisher","first-page":"1654","DOI":"10.2106\/JBJS.18.00734","volume":"101","author":"D Blonna","year":"2019","unstructured":"Blonna D, Assom M, Bellato E, Pisanu G, Greco V, Marmotti A, Rossi R. Outcomes of 188 proximal humeral fractures treated with a dedicated external fixator with follow-up ranging from 2 to 12 years. J Bone Joint Surg Am. 2019;101(18):1654\u201361.","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl 2 pt 2","key":"1235_CR30","doi-asserted-by":"publisher","first-page":"98","DOI":"10.2106\/00004623-200100022-00007","volume":"83-A","author":"AS Greenwald","year":"2001","unstructured":"Greenwald AS, Boden SD, Goldberg VM, Khan Y, Laurencin CT, Rosier RN. Bone-graft substitutes: facts, fictions, and applications. J Bone Joint Surg Am. 2001;83-A(Suppl 2 pt 2):98\u2013103.","journal-title":"J Bone Joint Surg Am"},{"issue":"2","key":"1235_CR31","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.injury.2019.10.025","volume":"51","author":"J Li","year":"2020","unstructured":"Li J, Li Z, Wang M, Zhang H, Liang Y, Zhang W. Fixation augmentation using titanium cage packing with xenograft in the treatment of tibial plateau fractures. Injury. 2020;51(2):490\u20136.","journal-title":"Injury"},{"issue":"2","key":"1235_CR32","first-page":"105","volume":"27","author":"KP Gunther","year":"1998","unstructured":"Gunther KP, Scharf HP, Pesch HJ, Puhl W. Integration properties of bone substitute materials. Experimental studies on animals. Der Orthopade. 1998;27(2):105\u201317.","journal-title":"Der Orthopade"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-021-01235-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-021-01235-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-021-01235-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,30]],"date-time":"2024-08-30T03:51:12Z","timestamp":1724989872000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-021-01235-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,4]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1235"],"URL":"https:\/\/doi.org\/10.1186\/s12893-021-01235-x","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,4]]},"assertion":[{"value":"23 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study has been approved by the Ethics Committee of Chinese PLA General Hospital under Grant No. S2020-114-01 and written informed consent was obtained from the patients for the publication of individual clinical details and accompanying images. This research has been conducted according to the ethical principles expressed in the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All the parents have signed the Informed Content Form. In this study, there is no any identifying personal or clinical details along with any identifying images to be published.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflicts of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"233"}}