{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T02:48:31Z","timestamp":1767494911716,"version":"3.37.3"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T00:00:00Z","timestamp":1643760000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T00:00:00Z","timestamp":1643760000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100010477","name":"intuitive surgical","doi-asserted-by":"publisher","award":["intuitive surgical"],"award-info":[{"award-number":["intuitive surgical"]}],"id":[{"id":"10.13039\/100010477","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>A novel robotic-assisted bipolar radiofrequency (RF) multifunctional vessel seal-and-transection instrument (SynchroSeal, Intuitive Surgical, Inc., Sunnyvale, CA) has been developed. The objective of the current paper is to describe the design of SynchroSeal based on bench studies, assess the safety of SynchroSeal in ex vivo and in vivo porcine studies, and provide early clinical context.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>SynchroSeal grasping, energy activation time, and jaw temperature were evaluated with those of the Harmonic Ace+7. Data were analyzed with descriptive statistics, with Mann\u2013Whitney for comparisons and statistical significance <jats:italic>p\u00a0<\/jats:italic>&lt; 0.05. Ex vivo and in vivo animal safety assessments of tissue after SynchroSeal use were evaluated for burst pressure, thermal spread, and acute sealing. Last, a single-center analysis of the technical metrics of SynchroSeal and Vessel Sealer Extend (robotically assisted seal-and-transection instrument) in bariatric cases is provided.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Bench studies of SynchroSeal and Harmonic Ace+7 evidenced SynchroSeal\u2019s greater slip resistance force (8.4\u2009\u00b1\u20091.0 vs. 3.1\u2009\u00b1\u20090.4\u2009N; <jats:italic>p<\/jats:italic> = 0.0002), lower grip pressure (3.0\u2009\u00b1\u20090.2 vs. 4.2\u2009\u00b1\u20090.5\u2009kg\/cm<jats:sup>2<\/jats:sup>; <jats:italic>p<\/jats:italic> = 0.0002), faster seal time (1.5\u2009\u00b1\u20090.4 vs. 11.6\u2009\u00b1\u20092.5\u2009s; <jats:italic>p\u00a0<\/jats:italic>&lt; 0.0001), lower mean jaw temperature (109.7\u2009\u00b1\u20097.2 vs. 247.4\u2009\u00b1\u20098.6\u00a0\u00b0C; <jats:italic>p<\/jats:italic> = 0.0051), and faster cooling to 40\u00a0\u00b0C (53.6\u2009\u00b1\u20092.1 vs. 68.0\u2009\u00b1\u20093.5\u2009s; <jats:italic>p<\/jats:italic> = 0.0051). SynchroSeal\u2019s mean burst pressures after seal-and-transection and seal only modes were, respectively, 1169.1\u2009\u00b1\u2009393.1\u2009mmHg and 1159.2\u2009\u00b1\u2009454.6\u2009mmHg. Mean thermal spreads were, respectively, 1.2\u2009\u00b1\u20090.6\u2009mm and 1.5\u2009\u00b1\u20090.55\u2009mm. In the chronic animal study, 102 vessels were sealed; at 3\u2009weeks post-procedure, there was no evidence of leakage or adverse events, such as non-target tissue thermal spread or tissue damage. In bariatrics cases, SynchroSeal was activated more frequently per case; however, its mean activation time was significantly shorter than Vessel Sealer Extend. No adverse events were reported for either device.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>SynchroSeal\u2019s multifunctional design provides enhanced sealing and transection capabilities with an acceptable safety profile.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12893-022-01483-5","type":"journal-article","created":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T16:06:34Z","timestamp":1643817994000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Novel multifunctional robotically assisted bipolar instrument for simultaneous radiofrequency sealing and transection: preclinical and single-center experience"],"prefix":"10.1186","volume":"22","author":[{"given":"Cristina","family":"Ibanez Jimenez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adrit","family":"Lath","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Forrest","family":"Ringold","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,2,2]]},"reference":[{"key":"1483_CR1","unstructured":"Buysse Steven P, Orszulak James H, Wham Robert H. Vessel sealing system. U.S. Patent No. 6,398,779. 4 Jun. 2002."},{"issue":"6","key":"1483_CR2","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1007\/s004649900733","volume":"12","author":"JS Kennedy","year":"1998","unstructured":"Kennedy JS, Stranahan PL, Taylor KD, Chandler JG. High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc. 1998;12(6):876\u20138. https:\/\/doi.org\/10.1007\/s004649900733.","journal-title":"Surg Endosc"},{"issue":"4","key":"1483_CR3","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.gmit.2017.08.002","volume":"6","author":"A Jaiswal","year":"2017","unstructured":"Jaiswal A, Huang K-G. Energy devices in gynecological laparoscopy\u2014archaic to modern era. Gynecol Minim Invasive Ther. 2017;6(4):147\u201351. https:\/\/doi.org\/10.1016\/j.gmit.2017.08.002.","journal-title":"Gynecol Minim Invasive Ther"},{"issue":"1","key":"1483_CR4","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1080\/13645700601181414","volume":"16","author":"K Entezari","year":"2007","unstructured":"Entezari K, Hoffmann P, Goris M, Peltier A, Van Velthoven R. A review of currently available vessel sealing systems. Minim Invasive Ther Allied Technol. 2007;16(1):52\u20137. https:\/\/doi.org\/10.1080\/13645700601181414.","journal-title":"Minim Invasive Ther Allied Technol"},{"issue":"8","key":"1483_CR5","doi-asserted-by":"publisher","first-page":"1228","DOI":"10.1007\/s00464-002-8833-7","volume":"17","author":"KL Harold","year":"2003","unstructured":"Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc. 2003;17(8):1228\u201330. https:\/\/doi.org\/10.1007\/s00464-002-8833-7 Epub 2003 Jun 13.","journal-title":"Surg Endosc"},{"issue":"2","key":"1483_CR6","doi-asserted-by":"publisher","first-page":"164","DOI":"10.21037\/gs.2020.01.18","volume":"9","author":"SC Yang","year":"2020","unstructured":"Yang SC, Ahn J-H, Kim JH, Yi JW, Hur MH, Lee K-Y. Comparison of the vessel sealer Extend\u00ae with harmonic ACE\u00ae in robotic bilateral axillary-breast approach thyroid surgery. Gland Surg. 2020;9(2):164\u201371. https:\/\/doi.org\/10.21037\/gs.2020.01.18.","journal-title":"Gland Surg"},{"key":"1483_CR7","unstructured":"Shah JM, Hemphill JW, Lundstrom FR, Marion DW. Patent Number: 20210093369 \u201cSimultaneous electrosurgical sealing and cutting\u201d Intuitive Surgical Operations, Inc., Sunnyvale, CA, USA."},{"issue":"1","key":"1483_CR8","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1007\/s00464-008-9932-x","volume":"23","author":"WL Newcomb","year":"2008","unstructured":"Newcomb WL, Hope WW, Schmelzer TM, Heath JJ, Norton HJ, Lincourt AE, Todd Heniford B, Iannitti DA. Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices. Surg Endosc. 2008;23(1):90\u20136. https:\/\/doi.org\/10.1007\/s00464-008-9932-x.","journal-title":"Surg Endosc"},{"key":"1483_CR9","doi-asserted-by":"publisher","first-page":"1464","DOI":"10.1007\/s00464-007-9650-9","volume":"22","author":"FJ Kim","year":"2008","unstructured":"Kim FJ, Chammas MF Jr, Gewehr E, Morihisa M, Caldas F, Hayacibara E, Baptistussi M, Meyer F, Martins AC. Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surg Endosc. 2008;22:1464\u20139.","journal-title":"Surg Endosc"},{"key":"1483_CR10","unstructured":"Premarket Notification (510(k)) Submissions for Bipolar Electrosurgical Vessel Sealers for General Surgery, Guidance for Industry and Food and Drug Administration Staff, August 2016."}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-022-01483-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-022-01483-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-022-01483-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,2]],"date-time":"2022-02-02T16:09:00Z","timestamp":1643818140000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-022-01483-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,2]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["1483"],"URL":"https:\/\/doi.org\/10.1186\/s12893-022-01483-5","relation":{},"ISSN":["1471-2482"],"issn-type":[{"type":"electronic","value":"1471-2482"}],"subject":[],"published":{"date-parts":[[2022,2,2]]},"assertion":[{"value":"29 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Institutional Review Board approval was not required for this study.\u00a0Live porcine animal models were used to evaluate thermal spread, seal, and transection performance of SynchroSeal with the E-100 generator. The experiments were approved by Intuitive Surgical\u2019s Animal Care and Use Committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Ms. Cristina Ibanez Jimenez and Mr. Adrit Lath are employees of and own stock in Intuitive Surgical; Ms. Ibanez Jimenez is also supported with work-related travel by her employer; Mr. Adrit Lath has patents pending on the SynchroSeal device. Dr. Forrest Ringold is a proctor for Intuitive and is on the company\u2019s speakers\u2019 bureau and owns Intuitive Surgical stock. All authors received third-party medical writing support, which was funded by Intuitive Surgical.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"37"}}