{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T10:09:11Z","timestamp":1767175751858,"version":"build-2238731810"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T00:00:00Z","timestamp":1668124800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T00:00:00Z","timestamp":1668124800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>A micromotion-based balanced drilling system was designed based on a locking plate (LP) and far cortical locking (FCL) concept to maintain the balance of micromotions of the cortex on both sides of a fracture region. The system was tested by axial compression test.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The fracture gap was set to 2\u00a0cm, and locking screws with a diameter of 5\u00a0mm and a locking plate were used to fix it. The diameters of the two sections of the stepping drill were 3.5\u00a0mm and 5.0\u00a0mm, respectively. One of the matching drilling sleeves was a standard sleeve (eccentricity, 0\u00a0mm) and the other was an eccentric sleeve (proximal eccentricity, 1\u00a0mm). A model of the fixed locking plate (AO\/ASIF 33-A3) for distal femoral fractures with a gap of 2\u00a0cm was established based on data from 42 artificial femurs (SAWBONE). According to the shape of the screw holes on the cortex, the fixed fracture models were divided into a control group (standard screw hole group X126, six cases) and an experimental group (elliptical screw hole group N, 36 cases). The experimental group was further divided into six subgroups with six cases in each (N126, N136, N1256, N1356, N12356, N123456), based on the number and distribution of the screws on the proximal fracture segment. The control, N126, and N136 groups were subjected to an axial load of 500\u00a0N, and the other groups were subjected to an axial load of 1000\u00a0N. The displacements of the kinetic head, far cortex, and near cortex were measured. The integral structural stiffness of the model and the near cortical strain were calculated. The data of each group were analyzed by using a paired\n                      <jats:italic>t<\/jats:italic>\n                      -test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>When the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were 0.96%, 2.35%, and 4.62%, respectively, significantly higher than those in the control group (X126) (p\u2009&lt;\u20090.05). For a different distribution of the screws, when the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were significantly higher than those in group N136 (p\u2009&lt;\u20090.05). However, there was no significant difference between the near cortical strains in the two groups with four screws (p\u2009&gt;\u20090.05). For different numbers of screws, the near cortical strains in the three-screw groups were significantly higher than those in the four-screw groups (p\u2009&lt;\u20090.05), and there was no significant difference in near cortical strains among the four-, five-, and six-screw groups (p\u2009&gt;\u20090.05).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The proposed drill and matching sleeves enabled a conventional locking compression plate to be transformed into an internal fixation system to improve the balanced motion of the near and far cortices. Thus, strain on a fracture site could be controlled by adjusting the diameter of the drill and the eccentricity of the sleeve.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12893-022-01816-4","type":"journal-article","created":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T04:06:43Z","timestamp":1668139603000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Micromotion-based balanced drilling technology to increase near cortical strain"],"prefix":"10.1186","volume":"22","author":[{"given":"Yang","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhanchao","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Shen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hua","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,11,11]]},"reference":[{"key":"1816_CR1","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.2174\/1874325001711011277","volume":"11","author":"AM Khan","year":"2017","unstructured":"Khan AM, Tang QO, Spicer D. The epidemiology of adult distal femoral shaft fractures in a Central London Major Trauma Centre over five years. Open Orthop J. 2017;11:1277\u201391.","journal-title":"Open Orthop J"},{"issue":"3","key":"1816_CR2","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1097\/BOT.0000000000001078","volume":"32","author":"P Myers","year":"2018","unstructured":"Myers P, Laboe P, Johnson KJ, et al. Patient mortality in geriatric distal femur fractures. J Orthop Trauma. 2018;32(3):111\u20135.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"1816_CR3","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1097\/BOT.0000000000000302","volume":"29","author":"MJ Beltran","year":"2015","unstructured":"Beltran MJ, Gary JL, Collinge CA. Management of distal femur fractures with modern plates and nails: state of the art. J Orthop Trauma. 2015;29(4):165\u201372.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 1","key":"1816_CR4","doi-asserted-by":"publisher","first-page":"S44","DOI":"10.1016\/S0020-1383(18)30302-4","volume":"49","author":"U Kandemir","year":"2018","unstructured":"Kandemir U. Distal femur: dynamization of plating. Injury. 2018;49(Suppl 1):S44\u20138.","journal-title":"Injury"},{"key":"1816_CR5","first-page":"175","volume":"138","author":"SM Perren","year":"1979","unstructured":"Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res. 1979;138:175\u201396.","journal-title":"Clin Orthop Relat Res"},{"issue":"8","key":"1816_CR6","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84(8):1093\u2013110.","journal-title":"J Bone Joint Surg Br"},{"issue":"6","key":"1816_CR7","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1007\/s11999-011-1870-6","volume":"469","author":"CE Henderson","year":"2011","unstructured":"Henderson CE, Lujan TJ, Kuhl LL, et al. 2010 mid-America Orthopaedic Association Physician in Training Award: healing complications are common after locked plating for distal femur fractures. Clin Orthop Relat Res. 2011;469(6):1757\u201365.","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl 1","key":"1816_CR8","doi-asserted-by":"publisher","first-page":"S8","DOI":"10.1097\/BOT.0b013e3182070127","volume":"25","author":"CE Henderson","year":"2011","unstructured":"Henderson CE, Kuhl LL, Fitzpatrick DC, Marsh JL. Locking plates for distal femur fractures: is there a problem with fracture healing? J Orthop Trauma. 2011;25(Suppl 1):S8-14.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"1816_CR9","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1097\/BOT.0000000000000593","volume":"30","author":"EK Rodriguez","year":"2016","unstructured":"Rodriguez EK, Zurakowski D, Herder L, et al. Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures. J Orthop Trauma. 2016;30(8):403\u20138.","journal-title":"J Orthop Trauma"},{"issue":"10","key":"1816_CR10","doi-asserted-by":"publisher","first-page":"752","DOI":"10.3928\/01477447-20100826-20","volume":"33","author":"DJ Hak","year":"2010","unstructured":"Hak DJ, Toker S, Yi C, Toreson J. The influence of fracture fixation biomechanics on fracture healing. Orthopedics. 2010;33(10):752\u20135.","journal-title":"Orthopedics"},{"issue":"8","key":"1816_CR11","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1080\/10255842.2013.855729","volume":"18","author":"S Miramini","year":"2015","unstructured":"Miramini S, Zhang L, Richardson M, et al. Computational simulation of the early stage of bone healing under different configurations of locking compression plates. Comput Methods Biomech Biomed Engin. 2015;18(8):900\u201313.","journal-title":"Comput Methods Biomech Biomed Engin"},{"issue":"8","key":"1816_CR12","doi-asserted-by":"publisher","first-page":"e241","DOI":"10.1097\/BOT.0000000000000860","volume":"31","author":"U Kandemir","year":"2017","unstructured":"Kandemir U, Augat P, Konowalczyk S, et al. Implant material, type of fixation at the shaft, and position of plate modify biomechanics of distal femur plate osteosynthesis. J Orthop Trauma. 2017;31(8):e241\u20136.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 2","key":"1816_CR13","doi-asserted-by":"publisher","first-page":"S25","DOI":"10.1097\/BOT.0000000000000621","volume":"30","author":"A von Keudell","year":"2016","unstructured":"von Keudell A, Shoji K, Nasr M, et al. Treatment options for distal femur fractures. J Orthop Trauma. 2016;30(Suppl 2):S25-27.","journal-title":"J Orthop Trauma"},{"key":"1816_CR14","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.clinbiomech.2018.05.012","volume":"56","author":"C Parks","year":"2018","unstructured":"Parks C, McAndrew CM, Spraggs-Hughes A, et al. In-vivo stiffness assessment of distal femur fracture locked plating constructs. Clin Biomech (Bristol, Avon). 2018;56:46\u201351.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"6","key":"1816_CR15","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1007\/s11999-016-4745-z","volume":"474","author":"PJ Dougherty","year":"2016","unstructured":"Dougherty PJ. CORR Insights((R)): addition of a medial locking plate to an in situ lateral locking plate results in healing of distal femoral nonunions. Clin Orthop Relat Res. 2016;474(6):1506\u20137.","journal-title":"Clin Orthop Relat Res"},{"issue":"6","key":"1816_CR16","doi-asserted-by":"publisher","DOI":"10.1097\/01.bot.0000398506.96521.7f","volume":"25","author":"M Bottlang","year":"2011","unstructured":"Bottlang M. Biomechanics of far cortical locking. J Orthop Trauma. 2011;25(6): e60.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"1816_CR17","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","volume":"24","author":"TJ Lujan","year":"2010","unstructured":"Lujan TJ, Henderson CE, Madey SM, et al. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156\u201362.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"1816_CR18","doi-asserted-by":"publisher","first-page":"1985","DOI":"10.2106\/JBJS.H.01038","volume":"91","author":"M Bottlang","year":"2009","unstructured":"Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91(8):1985\u201394.","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"1816_CR19","doi-asserted-by":"publisher","first-page":"1856","DOI":"10.1002\/jor.23193","volume":"34","author":"AR MacLeod","year":"2016","unstructured":"MacLeod AR, Simpson AH, Pankaj P. Age-related optimization of screw placement for reduced loosening risk in locked plating. J Orthop Res. 2016;34(11):1856\u201364.","journal-title":"J Orthop Res"},{"issue":"Suppl 2","key":"1816_CR20","doi-asserted-by":"publisher","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","volume":"34","author":"K Stoffel","year":"2003","unstructured":"Stoffel K, Dieter U, Stachowiak G, et al. Biomechanical testing of the LCP\u2013how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11-19.","journal-title":"Injury"},{"key":"1816_CR21","doi-asserted-by":"publisher","first-page":"S17","DOI":"10.1016\/j.otsr.2010.03.008","volume":"96","author":"P Cronier","year":"2010","unstructured":"Cronier P, Pietu G, Dujardin C, et al. The concept of locking plates. Orthop Traumatol Surg Res. 2010;96:S17.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"Suppl 2","key":"1816_CR22","doi-asserted-by":"publisher","first-page":"B63","DOI":"10.1016\/j.injury.2003.09.026","volume":"34","author":"E Gautier","year":"2003","unstructured":"Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63-76.","journal-title":"Injury"},{"issue":"7","key":"1816_CR23","doi-asserted-by":"publisher","first-page":"1652","DOI":"10.2106\/JBJS.I.01111","volume":"92","author":"M Bottlang","year":"2010","unstructured":"Bottlang M, Lesser M, Koerber J, et al. Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg Am. 2010;92(7):1652\u201360.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"1816_CR24","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1302\/2046-3758.71.BJR-2017-0074.R2","volume":"7","author":"A MacLeod","year":"2018","unstructured":"MacLeod A, Simpson A, Pankaj P. Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices. Bone Joint Res. 2018;7(1):111\u201320.","journal-title":"Bone Joint Res"}],"updated-by":[{"DOI":"10.1186\/s12893-022-01856-w","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T00:00:00Z","timestamp":1669161600000}}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-022-01816-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-022-01816-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-022-01816-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,24]],"date-time":"2022-11-24T13:23:17Z","timestamp":1669296197000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-022-01816-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,11]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1816"],"URL":"https:\/\/doi.org\/10.1186\/s12893-022-01816-4","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,11]]},"assertion":[{"value":"22 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 October 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 November 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 November 2022","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12893-022-01856-w","URL":"https:\/\/doi.org\/10.1186\/s12893-022-01856-w","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"387"}}