{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T03:14:31Z","timestamp":1773371671752,"version":"3.50.1"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T00:00:00Z","timestamp":1683763200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Scientific research project of Shanghai Municipal Commision of Health and Family Planning","award":["201740172"],"award-info":[{"award-number":["201740172"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Locking plates are commonly used in the treatment of comminuted metaphyseal distal femoral fractures. However, locking plates form a strong structure and promote asymmetrical callus formation, which is not conducive for rapid fracture healing and may increase fracture risk. To overcome this, we designed a micromotion-balancing fixation system based on locking plates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Six healthy pigs (Bama miniature pigs) were used to establish a model of bilateral comminuted distal femoral fracture (AO\/ASIF: 33-C2). Standard drilling was performed on one of each pig\u2019s hind limbs (control group), whereas eccentric drilling was performed on the other hind limb (experimental group). Both femurs were fixed with a 3-hole locking compression plate using 5-mm-diameter screws. At 12 postoperative weeks, all pigs were euthanized and the femurs with compression plates were radiographically examined. The level of fracture healing and loosening\/internal fixation failure were recorded. Bone mineral density, number of trabeculae, trabecular morphology, and calcification precipitations were assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>All pigs survived, and the fractures healed. No complications related to fracture healing, such as infection and internal fixation failure, were noted. The bone mineral density of the near and far cortical calli, number of the near and far cortical callus trabeculae, and difference in bone mineral density between the near and far cortical calli in the experimental group were significantly higher than those in the control group (p\u2009&lt;\u20090.01). However, the difference in the number of trabeculae between the near and far cortical calli was significantly lower in the experimental group than in the control group (p\u2009&lt;\u20090.01).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This newly designed system provides stable fixation for comminuted distal femoral fracture, increases the overall strain at the fracture site, and balances the strains at the near and far cortices to achieve uniform callus growth and fracture healing.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12893-023-01939-2","type":"journal-article","created":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T11:02:19Z","timestamp":1683802939000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Treatment of comminuted metaphyseal distal femoral fractures with a micromotion-balancing osteosynthesis: an animal study"],"prefix":"10.1186","volume":"23","author":[{"given":"Zhengwei","family":"Duan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hao","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diankai","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hua","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,5,11]]},"reference":[{"issue":"10","key":"1939_CR1","doi-asserted-by":"publisher","first-page":"597","DOI":"10.5435\/00124635-201010000-00003","volume":"18","author":"FW Gwathmey Jr","year":"2010","unstructured":"Gwathmey FW Jr, Jones-Quaidoo SM, Kahler D, Hurwitz S, Cui Q. Distal femoral fractures: current concepts. J Am Acad Orthop Surg. 2010;18(10):597\u2013607.","journal-title":"J Am Acad Orthop Surg"},{"issue":"8","key":"1939_CR2","doi-asserted-by":"publisher","first-page":"e241","DOI":"10.1097\/BOT.0000000000000860","volume":"31","author":"U Kandemir","year":"2017","unstructured":"Kandemir U, Augat P, Konowalczyk S, Wipf F, von Oldenburg G, Schmidt U. Implant material, type of fixation at the shaft, and position of plate modify biomechanics of distal femur plate osteosynthesis. J Orthop Trauma. 2017;31(8):e241\u20136.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"1939_CR3","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1055\/s-0030-1248022","volume":"20","author":"RM Greiwe","year":"2007","unstructured":"Greiwe RM, Archdeacon MT. Locking plate technology: current concepts. J Knee Surg. 2007;20(1):50\u20135.","journal-title":"J Knee Surg"},{"issue":"8","key":"1939_CR4","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Jt Surg Br. 2002;84(8):1093\u2013110.","journal-title":"J Bone Jt Surg Br"},{"issue":"3","key":"1939_CR5","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","volume":"24","author":"TJ Lujan","year":"2010","unstructured":"Lujan TJ, Henderson CE, Madey SM, Fitzpatrick DC, Marsh JL, Bottlang M. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24(3):156\u201362.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"1939_CR6","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318205c5d3","volume":"25","author":"JC Krieg","year":"2011","unstructured":"Krieg JC. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2011;25(2): e21; author reply e-2.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"1939_CR7","doi-asserted-by":"publisher","first-page":"620","DOI":"10.2106\/JBJS.H.00408","volume":"91","author":"M Bottlang","year":"2009","unstructured":"Bottlang M, Doornink J, Byrd GD, Fitzpatrick DC, Madey SM. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Jt Surg Am. 2009;91(3):620\u20137.","journal-title":"J Bone Jt Surg Am"},{"issue":"Suppl 2","key":"1939_CR8","doi-asserted-by":"publisher","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","volume":"34","author":"K Stoffel","year":"2003","unstructured":"Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS. Biomechanical testing of the LCP\u2014how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11\u20139.","journal-title":"Injury"},{"issue":"8","key":"1939_CR9","doi-asserted-by":"publisher","first-page":"1985","DOI":"10.2106\/JBJS.H.01038","volume":"91","author":"M Bottlang","year":"2009","unstructured":"Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Jt Surg Am. 2009;91(8):1985\u201394.","journal-title":"J Bone Jt Surg Am"},{"issue":"3","key":"1939_CR10","doi-asserted-by":"publisher","first-page":"208","DOI":"10.2106\/JBJS.M.00529","volume":"97","author":"H Richter","year":"2015","unstructured":"Richter H, Plecko M, Andermatt D, et al. Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep. J Bone Jt Surg Am. 2015;97(3):208\u201315.","journal-title":"J Bone Jt Surg Am"},{"issue":"4","key":"1939_CR11","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1097\/01.bot.0000438368.44077.04","volume":"28","author":"M Bottlang","year":"2014","unstructured":"Bottlang M, Fitzpatrick DC, Sheerin D, et al. Dynamic fixation of distal femur fractures using far cortical locking screws: a prospective observational study. J Orthop Trauma. 2014;28(4):181\u20138.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"1939_CR12","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1097\/01.ta.0000195462.53525.0c","volume":"60","author":"E Fulkerson","year":"2006","unstructured":"Fulkerson E, Egol KA, Kubiak EN, Liporace F, Kummer FJ, Koval KJ. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma. 2006;60(4):830\u20135.","journal-title":"J Trauma"},{"key":"1939_CR13","first-page":"175","volume":"138","author":"SM Perren","year":"1979","unstructured":"Perren SM. Physical and biological aspects of fracture healing with special reference to internal fixation. Clin Orthop Relat Res. 1979;138:175\u201396.","journal-title":"Clin Orthop Relat Res"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-023-01939-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-023-01939-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-023-01939-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T11:03:11Z","timestamp":1683802991000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-023-01939-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,11]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1939"],"URL":"https:\/\/doi.org\/10.1186\/s12893-023-01939-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2344192\/v1","asserted-by":"object"}]},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,11]]},"assertion":[{"value":"5 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The procedures for care and use of animals were approved by the Ethics Committee of Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine. ARRIVE guidelines and all applicable institutional and governmental regulations concerning the ethical use of animals were followed.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"118"}}