{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T17:59:11Z","timestamp":1788458351495,"version":"build-2803163510"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,2,28]],"date-time":"2023-02-28T00:00:00Z","timestamp":1677542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,2,28]],"date-time":"2023-02-28T00:00:00Z","timestamp":1677542400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Dynesys stabilization (DS) is utilized to preserve mobility at the instrumental segments and prevent adjacent segment pathology in clinical practice. However, the advantages of DS method in medium and long-term follow-up remain controversial.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>To compare the radiographic and clinical outcomes between DS and instrumented fusion in the treatment of degenerative lumbar spine disease with or without grade I spondylolisthesis with a minimum follow-up period of 2\u00a0years.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We conducted a comprehensive search of PubMed, EMBASE, Cochrane, and Web of Science databases, Chinese National Knowledge Databases, and Wanfang Database for potentially eligible articles. Clinical outcomes were assessed in terms of VAS and ODI scores, screw loosening and breakage, and surgical revision. Radiographic outcomes were assessed in terms of postoperative range of movement (ROM) and disc heigh. Moreover, adjacent segment degeneration (ASDeg) and adjacent segment disease (ASDis) were evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Seventeen studies with 1296 patients were included in the meta-analysis. The DS group was associated with significantly lower postoperative VAS scores for low-back and leg pain, and lower rate of surgical revision than the fusion group. Moreover, the Dynesys group showed significantly less ASDeg than the fusion group but showed no significant advantage over the fusion group in terms of preventing ASDis. Additionally, the ROM at the stabilized segments of the fusion group decreased significantly and that at the adjacent segments increased significantly compared with those of the DS group.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>DS showed comparable clinical outcomes and provided benefits in preserving the motion at the stabilized segments, thus limiting the hypermobility at the adjacent segments and preventing ASDeg compared with the fusion method in degenerative disease with or without grade I spondylolisthesis.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12893-023-01943-6","type":"journal-article","created":{"date-parts":[[2023,2,28]],"date-time":"2023-02-28T13:02:54Z","timestamp":1677589374000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Medium and long-term radiographic and clinical outcomes of Dynesys dynamic stabilization versus instrumented fusion for degenerative lumbar spine diseases"],"prefix":"10.1186","volume":"23","author":[{"given":"Lu-Ping","family":"Zhou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren-Jie","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia-Qi","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hua-Qing","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Shang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong-Yu","family":"Jia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing-Yu","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lai","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cai-Liang","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,2,28]]},"reference":[{"issue":"5","key":"1943_CR1","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1093\/neuros\/nyw162","volume":"80","author":"D Yavin","year":"2017","unstructured":"Yavin D, Casha S, Wiebe S, Feasby TE, Clark C, Isaacs A, Holroyd-Leduc J, Hurlbert RJ, Quan H, Nataraj A, et al. Lumbar fusion for degenerative disease: a systematic review and meta-analysis. Neurosurgery. 2017;80(5):701\u201315.","journal-title":"Neurosurgery"},{"issue":"5","key":"1943_CR2","doi-asserted-by":"publisher","first-page":"807","DOI":"10.4184\/asj.2015.9.5.807","volume":"9","author":"JC Lee","year":"2015","unstructured":"Lee JC, Choi S-W. Adjacent segment pathology after lumbar spinal fusion. Asian Spine J. 2015;9(5):807\u201317.","journal-title":"Asian Spine J"},{"key":"1943_CR3","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1186\/s13018-015-0231-7","volume":"10","author":"H Fei","year":"2015","unstructured":"Fei H, Xu J, Wang S, Xie Y, Ji F, Xu Y. Comparison between posterior dynamic stabilization and posterior lumbar interbody fusion in the treatment of degenerative disc disease: a prospective cohort study. J Orthop Surg Res. 2015;10:87.","journal-title":"J Orthop Surg Res"},{"issue":"5","key":"1943_CR4","doi-asserted-by":"publisher","first-page":"1409","DOI":"10.1007\/s00586-015-4307-1","volume":"25","author":"Q Wang","year":"2016","unstructured":"Wang Q, Liu J, Shi Y, Chen Y, Yu H, Ma J, Ren W, Yang H, Wang H, Xiang L. Short-term effects of a dynamic neutralization system (Dynesys) for multi-segmental lumbar disc herniation. Eur Spine J. 2016;25(5):1409\u201316.","journal-title":"Eur Spine J"},{"issue":"21","key":"1943_CR5","doi-asserted-by":"publisher","first-page":"2537","DOI":"10.4103\/0366-6999.244107","volume":"131","author":"Y Zhang","year":"2018","unstructured":"Zhang Y, Zhang ZC, Li F, Sun TS, Shan JL, Guan K, Zhao GM, Zhang LZ. Long-term outcome of dynesys dynamic stabilization for lumbar spinal stenosis. Chin Med J (Engl). 2018;131(21):2537\u201343.","journal-title":"Chin Med J (Engl)"},{"issue":"1","key":"1943_CR6","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1097\/BSD.0000000000000328","volume":"29","author":"C Zhang","year":"2016","unstructured":"Zhang C, Berven SH, Fortin M, Weber MH. Adjacent segment degeneration versus disease after lumbar spine fusion for degenerative pathology. Clin Spine Surg. 2016;29(1):21\u20139.","journal-title":"Clin Spine Surg"},{"issue":"10","key":"1943_CR7","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1007\/s00402-019-03234-3","volume":"139","author":"A Hu","year":"2019","unstructured":"Hu A, Sun C, Liang Y, Wang H, Li X, Dong J. Multi-segmental lumbar spinal stenosis treated with Dynesys stabilization versus lumbar fusion in elderly patients: a retrospective study with a minimum of 5 years\u2019 follow-up. Arch Orthop Trauma Surg. 2019;139(10):1361\u20138.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"1943_CR8","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1007\/s00264-018-4241-z","volume":"43","author":"K Hashimoto","year":"2019","unstructured":"Hashimoto K, Aizawa T, Kanno H, Itoi E. Adjacent segment degeneration after fusion spinal surgery-a systematic review. Int Orthop. 2019;43(4):987\u201393.","journal-title":"Int Orthop"},{"issue":"1","key":"1943_CR9","first-page":"180","volume":"83","author":"Y-J Huang","year":"2017","unstructured":"Huang Y-J, Zhao S-J, Zhang Q, Nong L-M, Xu N-W. Comparison of lumbar pedicular dynamic stabilisation systems versus fusion for the treatment of lumbar degenerative disc disease: a meta-analysis. Acta Orthop Belg. 2017;83(1):180\u201393.","journal-title":"Acta Orthop Belg"},{"key":"1943_CR10","doi-asserted-by":"publisher","first-page":"8","DOI":"10.14444\/3008","volume":"10","author":"SE Lee","year":"2016","unstructured":"Lee SE, Jahng T-A, Kim H-J. Clinical experiences of non-fusion dynamic stabilization surgery for adjacent segmental pathology after lumbar fusion. Int J Spine Surg. 2016;10:8.","journal-title":"Int J Spine Surg"},{"issue":"10","key":"1943_CR11","doi-asserted-by":"publisher","first-page":"1554","DOI":"10.1016\/j.spinee.2020.05.100","volume":"20","author":"CJ Donnally","year":"2020","unstructured":"Donnally CJ, Patel PD, Canseco JA, Divi SN, Goz V, Sherman MB, Shenoy K, Markowitz M, Rihn JA, Vaccaro AR. Current incidence of adjacent segment pathology following lumbar fusion versus motion-preserving procedures: a systematic review and meta-analysis of recent projections. Spine J. 2020;20(10):1554\u201365.","journal-title":"Spine J"},{"issue":"4","key":"1943_CR12","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1097\/BSD.0b013e3181a4bb0b","volume":"23","author":"AH Fayyazi","year":"2010","unstructured":"Fayyazi AH, Ordway NR, Park S-A, Fredrickson BE, Yonemura K, Yuan HA. Radiostereometric analysis of postoperative motion after application of Dynesys dynamic posterior stabilization system for treatment of degenerative spondylolisthesis. J Spinal Disord Tech. 2010;23(4):236\u201341.","journal-title":"J Spinal Disord Tech"},{"issue":"2","key":"1943_CR13","first-page":"190","volume":"30","author":"G Akyoldas","year":"2020","unstructured":"Akyoldas G, Cevik OM, Suzer T, Sasani M, Oktenoglu T, Ozer AF. Dynamic stabilization of the lumbar spine using the dynesys system. Turk Neurosurg. 2020;30(2):190\u20133.","journal-title":"Turk Neurosurg"},{"issue":"16","key":"1943_CR14","doi-asserted-by":"publisher","first-page":"E893","DOI":"10.1097\/BRS.0000000000004049","volume":"46","author":"J-M Jung","year":"2021","unstructured":"Jung J-M, Hyun S-J, Kim K-J, Jahng T-A. Dynamic stabilization surgery in patients with spinal stenosis: Long-term outcomes and the future. Spine. 2021;46(16):E893\u2013900.","journal-title":"Spine"},{"issue":"5","key":"1943_CR15","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.1177\/0300060517708104","volume":"45","author":"H Wu","year":"2017","unstructured":"Wu H, Pang Q, Jiang G. Medium-term effects of Dynesys dynamic stabilization versus posterior lumbar interbody fusion for treatment of multisegmental lumbar degenerative disease. J Int Med Res. 2017;45(5):1562\u201373.","journal-title":"J Int Med Res"},{"issue":"7","key":"1943_CR16","first-page":"14698","volume":"9","author":"J He","year":"2016","unstructured":"He J, Li J, Luo C, Sun Y, Nong L, Xie H. Impact of the Dynesys dynamic stabilization system on the fixation-adjacent intervertebral discs. Int J Clin Exp Med. 2016;9(7):14698\u2013703.","journal-title":"Int J Clin Exp Med"},{"issue":"6","key":"1943_CR17","doi-asserted-by":"publisher","first-page":"574","DOI":"10.4103\/0019-5413.144222","volume":"48","author":"M Yang","year":"2014","unstructured":"Yang M, Li C, Chen Z, Bai Y, Li M. Short term outcome of posterior dynamic stabilization system in degenerative lumbar diseases. Indian J Orthop. 2014;48(6):574\u201381.","journal-title":"Indian J Orthop"},{"key":"1943_CR18","doi-asserted-by":"publisher","first-page":"3043645","DOI":"10.1155\/2021\/3043645","volume":"2021","author":"C Zhao","year":"2021","unstructured":"Zhao C, Liu L, Luo L, Li P, Wang Y, Liang L, Wen X, Jiang D, Zhou Q. Effect of discectomy on Dynesys dynamic fixation in the treatment of lumbar degenerative diseases. Pain Res Manag. 2021;2021:3043645.","journal-title":"Pain Res Manag"},{"key":"1943_CR19","doi-asserted-by":"publisher","first-page":"1288246","DOI":"10.1155\/2021\/1288246","volume":"2021","author":"L Luo","year":"2021","unstructured":"Luo L, Zhao C, Li P, Liu L, Zhou Q, Luo F, Liang L. Posterior dynamic stabilization with limited rediscectomy for recurrent lumbar disc herniation. Pain Res Manag. 2021;2021:1288246.","journal-title":"Pain Res Manag"},{"issue":"1","key":"1943_CR20","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1186\/s13018-017-0597-9","volume":"12","author":"C Zhang","year":"2017","unstructured":"Zhang C, Wang L, Hou T, Luo L, Zhao C, Gan Y, Zhou Q, Li P. The influence of L4\u2013S1 Dynesys\u00ae dynamic stabilization versus fusion on lumbar motion and its relationship with lumbar degeneration: a retrospective study. J Orthop Surg Res. 2017;12(1):99.","journal-title":"J Orthop Surg Res"},{"issue":"2","key":"1943_CR21","first-page":"230","volume":"78","author":"S-W Yu","year":"2012","unstructured":"Yu S-W, Yang S-C, Ma C-H, Wu C-H, Yen C-Y, Tu Y-K. Comparison of Dynesys posterior stabilization and posterior lumbar interbody fusion for spinal stenosis L4L5. Acta Orthop Belg. 2012;78(2):230\u20139.","journal-title":"Acta Orthop Belg"},{"issue":"3","key":"1943_CR22","doi-asserted-by":"publisher","first-page":"250","DOI":"10.3171\/2018.1.SPINE17993","volume":"29","author":"C-H Kuo","year":"2018","unstructured":"Kuo C-H, Huang W-C, Wu J-C, Tu T-H, Fay L-Y, Wu C-L, Cheng H. Radiological adjacent-segment degeneration in L4\u20135 spondylolisthesis: comparison between dynamic stabilization and minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine. 2018;29(3):250\u20138.","journal-title":"J Neurosurg Spine"},{"issue":"3","key":"1943_CR23","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1097\/BRS.0000000000001158","volume":"41","author":"GH St-Pierre","year":"2016","unstructured":"St-Pierre GH, Jack A, Siddiqui MMA, Henderson RL, Nataraj A. Nonfusion does not prevent adjacent segment disease: Dynesys long-term outcomes with minimum five-year follow-up. Spine. 2016;41(3):265\u201373.","journal-title":"Spine"},{"issue":"1","key":"1943_CR24","doi-asserted-by":"publisher","first-page":"E0148071","DOI":"10.1371\/journal.pone.0148071","volume":"11","author":"Y Zhang","year":"2016","unstructured":"Zhang Y, Shan J-L, Liu X-M, Li F, Guan K, Sun T-S. Comparison of the dynesys dynamic stabilization system and posterior lumbar interbody fusion for lumbar degenerative disease. PLoS ONE. 2016;11(1):E0148071.","journal-title":"PLoS ONE"},{"issue":"1","key":"1943_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.spinee.2012.10.023","volume":"14","author":"MD Silvestre","year":"2014","unstructured":"Silvestre MD, Lolli F, Bakaloudis G. Degenerative lumbar scoliosis in elderly patients: dynamic stabilization without fusion versus posterior instrumented fusion. Spine J. 2014;14(1):1\u201310.","journal-title":"Spine J"},{"issue":"1","key":"1943_CR26","first-page":"97","volume":"79","author":"B Haddad","year":"2013","unstructured":"Haddad B, Makki D, Konan S, Park D, Khan W, Okafor B. Dynesys dynamic stabilization: less good outcome than lumbar fusion at 4-year follow-up. Acta Orthop Belg. 2013;79(1):97\u2013103.","journal-title":"Acta Orthop Belg"},{"issue":"7","key":"1943_CR27","doi-asserted-by":"publisher","first-page":"E1000100","DOI":"10.1371\/journal.pmed.1000100","volume":"6","author":"A Liberati","year":"2009","unstructured":"Liberati A, Altman DG, Tetzlaff J, Mulrow C, G\u00f8tzsche PC, Ioannidis JPA, Clarke M, Devereaux PJ, Kleijnen J, Moher D. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med. 2009;6(7):E1000100.","journal-title":"PLoS Med"},{"key":"1943_CR28","unstructured":"Higgins JPT, Green S. Cochrane handbook for systematic reviews of interventions version 5.1.0. The Cochrane Collaboration, 2011. http:\/\/www.cochrane-handbook.org. Accessed March 20, 2012."},{"key":"1943_CR29","unstructured":"Wells GA, Shea B, O\u2019Connell D, Robertson J, Peterson J, Welch V, Losos M, Tugwell P. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies in meta-analysis. 2011. http:\/\/www.ohri.ca\/programs\/clinicalepidemiology\/oxford.asp Accessed April 15, 2012."},{"issue":"6","key":"1943_CR30","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1016\/j.jos.2017.07.007","volume":"22","author":"K Liu","year":"2017","unstructured":"Liu K, Sun W, Lu Q, Chen J, Tang J. A cost-utility analysis of Dynesys dynamic stabilization versus instrumented fusion for the treatment of degenerative lumbar spine diseases. J Orthop Sci. 2017;22(6):982\u20137.","journal-title":"J Orthop Sci"},{"key":"1943_CR31","doi-asserted-by":"publisher","first-page":"9367106","DOI":"10.1155\/2022\/9367106","volume":"2022","author":"L Luo","year":"2022","unstructured":"Luo L, Liu L, Li P, Zhao C, Liang L, Luo F, Zhou Q, Chen Y, Fang L. Comparison between dynamic stabilization and instrumented fusion in the treatment of spinal stenosis with degenerative lumbar scoliosis. Pain Res Manag. 2022;2022:9367106.","journal-title":"Pain Res Manag"},{"issue":"17","key":"1943_CR32","first-page":"1247","volume":"41","author":"C Zheng","year":"2021","unstructured":"Zheng C, Liu J, Du J, Ma W, Chen Y, Wu J. Application of Dynesys dynamic stabilization with microendoscopic discectomy for the degenerative lumbar spinal stenosis in the elder. Chin J Orthop. 2021;41(17):1247\u201356.","journal-title":"Chin J Orthop"},{"issue":"17","key":"1943_CR33","first-page":"1180","volume":"41","author":"K Zhang","year":"2021","unstructured":"Zhang K, Luo K, Cai K, Lu B, Lu J, Jiang G, Wu H. Medium and long\u2043term comparisons of Dynesys stabilization and posterior lumbar interbody fusion for two\u2043level lum\u2043 bar degenerative diseases. Chin J Orthop. 2021;41(17):1180\u20137.","journal-title":"Chin J Orthop"},{"issue":"6","key":"1943_CR34","first-page":"445","volume":"9","author":"D-W Ren","year":"2018","unstructured":"Ren D-W, Li Q, Jia T, He Y. Comparison of the Dynesys dynamicinternal system and transforminal lumbar interbody fusion for degenerative L5\/S1 disc herniation. Orthopaedics. 2018;9(6):445\u201350.","journal-title":"Orthopaedics"},{"issue":"8","key":"1943_CR35","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.otsr.2017.07.020","volume":"103","author":"S Bredin","year":"2017","unstructured":"Bredin S, Demay O, Mensa C, Madi K, Ohl X. Posterolateral fusion versus Dynesys dynamic stabilization: retrospective study at a minimum 5.5 years\u2019 follow-up. Orthop Traumatol Surg Res. 2017;103(8):1241\u20134.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"1","key":"1943_CR36","doi-asserted-by":"publisher","first-page":"93","DOI":"10.21037\/jss.2018.03.20","volume":"4","author":"K Veresciagina","year":"2018","unstructured":"Veresciagina K, Mehrkens A, Sch\u00e4ren S, Jeanneret B. Minimum ten-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. J Spine Surg. 2018;4(1):93\u2013101.","journal-title":"J Spine Surg"},{"issue":"2","key":"1943_CR37","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1097\/BSD.0b013e318277ca7a","volume":"29","author":"S Hoppe","year":"2012","unstructured":"Hoppe S, Schwarzenbach O, Aghayev E, Bonel H, Berlemann U. Long-term outcome after monosegmental L4\/5 stabilization for degenerative spondylolisthesis with the Dynesys device. Clin Spine Surg. 2012;29(2):72\u20137.","journal-title":"Clin Spine Surg"},{"issue":"18","key":"1943_CR38","doi-asserted-by":"publisher","first-page":"E636","DOI":"10.1097\/BRS.0b013e31817d2435","volume":"33","author":"S Schaeren","year":"2008","unstructured":"Schaeren S, Broger I, Jeanneret B. Minimum four-year follow-up of spinal stenosis with degenerative spondylolisthesis treated with decompression and dynamic stabilization. Spine. 2008;33(18):E636\u201342.","journal-title":"Spine"},{"issue":"11","key":"1943_CR39","doi-asserted-by":"publisher","first-page":"E0188328","DOI":"10.1371\/journal.pone.0188328","volume":"12","author":"Y M\u00e1s","year":"2017","unstructured":"M\u00e1s Y, Gracia L, Ibarz E, Gabarre S, Pe\u00f1a D, Herrera A. Finite element simulation and clinical follow-up of lumbar spine biomechanics with dynamic fixations. PLoS ONE. 2017;12(11):E0188328.","journal-title":"PLoS ONE"},{"issue":"26","key":"1943_CR40","doi-asserted-by":"publisher","first-page":"2909","DOI":"10.1097\/BRS.0b013e31818bdca7","volume":"33","author":"A Kumar","year":"2008","unstructured":"Kumar A, Beastall J, Hughes J, Karadimas EJ, Nicol M, Smith F, Wardlaw D. Disc changes in the bridged and adjacent segments after Dynesys dynamic stabilization system after two years. Spine. 2008;33(26):2909\u201314.","journal-title":"Spine"},{"issue":"6","key":"1943_CR41","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1007\/s00132-009-1585-5","volume":"39","author":"C Kl\u00f6ckner","year":"2010","unstructured":"Kl\u00f6ckner C. Long-term results of the Dynesys implant. Orthopade. 2010;39(6):559\u201364.","journal-title":"Orthopade"},{"issue":"11","key":"1943_CR42","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1097\/BRS.0b013e31828150a6","volume":"38","author":"E Hoff","year":"2013","unstructured":"Hoff E, Strube P, Gross C, Putzier M. Sequestrectomy with additional transpedicular dynamic stabilization for the treatment of lumbar disc herniation: no clinical benefit after 10 years follow-up. Spine. 2013;38(11):887\u201395.","journal-title":"Spine"},{"key":"1943_CR43","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1186\/1471-2474-14-191","volume":"14","author":"S-L Shih","year":"2013","unstructured":"Shih S-L, Liu C-L, Huang L-Y, Huang C-H, Chen C-S. Effects of cord pretension and stiffness of the dynesys system spacer on the biomechanics of spinal decompression- a finite element study. BMC Musculoskelet Disord. 2013;14:191.","journal-title":"BMC Musculoskelet Disord"},{"issue":"9","key":"1943_CR44","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1177\/0954411920934956","volume":"234","author":"M Mesbah","year":"2020","unstructured":"Mesbah M, Barkaoui A. Biomechanical investigation of the effect of pedicle-based hybrid stabilization constructs: a finite element study. Proc Inst Mech Eng H. 2020;234(9):931\u201341.","journal-title":"Proc Inst Mech Eng H"},{"issue":"1","key":"1943_CR45","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2015.10.FOCUS15426","volume":"40","author":"C-H Lee","year":"2016","unstructured":"Lee C-H, Jahng T-A, Hyun S-J, Kim CH, Park S-B, Kim K-J, Chung CK, Kim H-J, Lee S-E. Dynamic stabilization using the Dynesys system versus posterior lumbar interbody fusion for the treatment of degenerative lumbar spinal disease: a clinical and radiological outcomes-based meta-analysis. Neurosurg Focus. 2016;40(1):E7.","journal-title":"Neurosurg Focus"},{"issue":"1","key":"1943_CR46","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.spinee.2012.11.014","volume":"13","author":"T-A Jahng","year":"2013","unstructured":"Jahng T-A, Kim YE, Moon KY. Comparison of the biomechanical effect of pedicle-based dynamic stabilization: a study using finite element analysis. Spine J. 2013;13(1):85\u201394.","journal-title":"Spine J"},{"issue":"6","key":"1943_CR47","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/2010.3.FOCUS1052","volume":"28","author":"CC Ko","year":"2010","unstructured":"Ko CC, Tsai HW, Huang WC, Wu JC, Chen YC, Shih YH, Chen HC, Wu CL, Cheng H. Screw loosening in the Dynesys stabilization system: radiographic evidence and effect on outcomes. Neurosurg Focus. 2010;28(6):E10.","journal-title":"Neurosurg Focus"},{"issue":"17","key":"1943_CR48","first-page":"1237","volume":"41","author":"A Hu","year":"2021","unstructured":"Hu A, Chen F, Jiang L, Jiang Y, Lin H, Li X, Zhou X, Dong J. Mid- and long-term outcomes of hybrid surgery combined Dynesys fusion and non-fusion stabilization in the treatment of degenerative lumbar diseases. Chin J Orthop. 2021;41(17):1237\u201346.","journal-title":"Chin J Orthop"},{"key":"1943_CR49","unstructured":"The Lumbar Research Group of Spinal Cord Committee of Chinese Association of Rehabilitation Medicine. Expert consensus on the treatment of lumbar degenerative disease by transpedicle dynamic rod fixation. Chin J Orthop 2020; 40(24):1639\u20131645."},{"issue":"6","key":"1943_CR50","first-page":"318","volume":"2","author":"J Guo","year":"2013","unstructured":"Guo J, Hou S, Shi Y, Li L, Wang H. Early clinical effects of Dynesys dynamic internal fixation system for mild lumbar degenerative spondylolisthesis. Chin J Bone Joint. 2013;2(6):318\u201321.","journal-title":"Chin J Bone Joint"},{"key":"1943_CR51","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/j.wneu.2016.06.048","volume":"93","author":"BJ Schwaiger","year":"2016","unstructured":"Schwaiger BJ, Behr M, Gersing AS, Meyer B, Zimmer C, Kirschke JS, Ryang YM, Ringel F. Computed tomography findings associated with clinical outcome after dynamic posterior stabilization of the lumbar spine. World Neurosurg. 2016;93:306\u201314.","journal-title":"World Neurosurg"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-023-01943-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-023-01943-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-023-01943-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,28]],"date-time":"2023-02-28T14:03:31Z","timestamp":1677593011000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-023-01943-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,28]]},"references-count":51,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1943"],"URL":"https:\/\/doi.org\/10.1186\/s12893-023-01943-6","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,28]]},"assertion":[{"value":"15 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This trial is a meta-analysis, which we collected data from other included studies. Ethics approval and consent to participate is not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors confirmed that there is no conflict of interest regarding the submitted manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"46"}}