{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,6]],"date-time":"2025-06-06T10:27:03Z","timestamp":1749205623907,"version":"3.37.3"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T00:00:00Z","timestamp":1700265600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T00:00:00Z","timestamp":1700265600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100010256","name":"Guangzhou Municipal Science and Technology Project","doi-asserted-by":"publisher","award":["201803010046"],"award-info":[{"award-number":["201803010046"]}],"id":[{"id":"10.13039\/501100010256","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81672232"],"award-info":[{"award-number":["81672232"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Backgrounds<\/jats:title>\n                <jats:p>This study aimed to compare whether Calcium phosphate cement (CPC) promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Through a self-designed bone cement injection device, the pedicle screw canal was strengthened with calcium phosphate bone cement, and divided into 4-hole group, 6-hole group, 8-hole group, straight pore group and the control group. The screw was inserted into the mechanical test module, the Maximum insertion torque and Maximum axial pull-out strength were recorded, and the distribution of calcium phosphate bone cement was analyzed by CT and X-ray. The data results were analyzed using SPSS19.0 statistical software package.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The distribution of bone cement in different reinforcement groups was different and showed regularity. The bone cement in the 4-hole group was roughly located in the head 1\/3 of the screw, the 6-hole group was located in the middle 1\/3 of the screw, and the 8-hole group was located in the caudal 1\/3 of the screw. Compared with the control group, the maximum axial pull-out force of screws in the lateral hole and full screw tunnel reinforcement group was significantly increased. There was no significant difference between the 4-hole, 6-hole and straight pore groups. There was no difference in the screw-in torque between the reinforcement groups, and they all increased significantly compared with the control group, and the difference was statistically significant. After the screw was pulled out, the interface between the bone cement and the polyurethane material was fractured, and a tight package was formed with the screw.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Enhancer syringes with different hole numbers combined with CPC bone cement injection can significantly increase the maximum screw pull-out force. The 8-hole group has a smaller pull-out force and is relatively prone to leakage of reinforcing material, which lacks safety in use. The local reinforcement of 4-hole and 6-hole sheath can play a similar role to that of total nail tunnel reinforcement.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12893-023-02235-9","type":"journal-article","created":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T19:02:59Z","timestamp":1700334179000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Calcium phosphate cement promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes"],"prefix":"10.1186","volume":"23","author":[{"given":"Suochao","family":"Fu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Renkai","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaobao","family":"Zou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fuzhi","family":"Ai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianhua","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiangyang","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Lei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,11,18]]},"reference":[{"issue":"2","key":"2235_CR1","doi-asserted-by":"publisher","first-page":"393","DOI":"10.3906\/sag-2005-315","volume":"51","author":"FY Kutsal","year":"2021","unstructured":"Kutsal FY, Ergin Ergani GO. Vertebral compression fractures: still an unpredictable aspect of osteoporosis. Turk J Med Sci. 2021;51(2):393\u20139.","journal-title":"Turk J Med Sci"},{"issue":"4","key":"2235_CR2","first-page":"592","volume":"5","author":"JF Griffith","year":"2015","unstructured":"Griffith JF. Identifying osteoporotic vertebral fracture. Quant Imaging Med Surg. 2015;5(4):592\u2013602.","journal-title":"Quant Imaging Med Surg"},{"issue":"12","key":"2235_CR3","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.1016\/j.addr.2012.01.008","volume":"64","author":"MP Ginebra","year":"2012","unstructured":"Ginebra MP, Canal C, Espanol M, Pastorino D, Montufar EB. Calcium phosphate cements as drug delivery materials. Adv Drug Deliv Rev. 2012;64(12):1090\u2013110.","journal-title":"Adv Drug Deliv Rev"},{"key":"2235_CR4","doi-asserted-by":"publisher","first-page":"17056","DOI":"10.1038\/boneres.2017.56","volume":"5","author":"HH Xu","year":"2017","unstructured":"Xu HH, Wang P, Wang L, Bao C, Chen Q, Weir MD, et al. Calcium phosphate cements for bone engineering and their biological properties. Bone Res. 2017;5:17056.","journal-title":"Bone Res"},{"key":"2235_CR5","doi-asserted-by":"publisher","first-page":"110481","DOI":"10.1016\/j.msec.2019.110481","volume":"109","author":"T Wu","year":"2020","unstructured":"Wu T, Shi H, Liang Y, Lu T, Lin Z, Ye J. Improving osteogenesis of calcium phosphate bone cement by incorporating with manganese doped beta-tricalcium phosphate. Mater Sci Eng C Mater Biol Appl. 2020;109:110481.","journal-title":"Mater Sci Eng C Mater Biol Appl"},{"issue":"1","key":"2235_CR6","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1186\/s12891-022-05181-4","volume":"23","author":"S Fu","year":"2022","unstructured":"Fu S, Zhang Y, Ai F, Wang J, Wu Z, Ma X, et al. A novel bone cement injector augments Chinese osteoporotic lumbar pedicle screw channel: a biomechanical investigation. BMC Musculoskelet Disord. 2022;23(1):353.","journal-title":"BMC Musculoskelet Disord"},{"issue":"5","key":"2235_CR7","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1007\/s43465-021-00495-2","volume":"55","author":"A Kumar","year":"2021","unstructured":"Kumar A, Ghosh R. Fracture toughness of Acrylic PMMA Bone Cement: a Mini-review. Indian J Orthop. 2021;55(5):1208\u201314.","journal-title":"Indian J Orthop"},{"key":"2235_CR8","doi-asserted-by":"crossref","unstructured":"Bistolfi A, Ferracini R, Albanese C, Verne E, Miola M. PMMA-Based bone cements and the Problem of Joint Arthroplasty Infections: Status and New perspectives. Mater (Basel). 2019;12(23).","DOI":"10.3390\/ma12234002"},{"issue":"2","key":"2235_CR9","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1093\/rb\/rbz004","volume":"6","author":"X Ji","year":"2019","unstructured":"Ji X, Xu F, Dong G, Jia C, Jia P, Chen H, et al. Loading necrostatin-1 composite bone cement inhibits necroptosis of bone tissue in rabbit. Regen Biomater. 2019;6(2):113\u20139.","journal-title":"Regen Biomater"},{"issue":"5","key":"2235_CR10","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1016\/j.ajodo.2012.06.013","volume":"142","author":"RA Meursinge Reynders","year":"2012","unstructured":"Meursinge Reynders RA, Ronchi L, Ladu L, van Etten-Jamaludin F, Bipat S. Insertion torque and success of orthodontic mini-implants: a systematic review. Am J Orthod Dentofacial Orthop. 2012;142(5):596\u2013614e5.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"14","key":"2235_CR11","doi-asserted-by":"publisher","first-page":"E478","DOI":"10.1097\/BRS.0b013e3181a8f663","volume":"34","author":"C Waits","year":"2009","unstructured":"Waits C, Burton D, McIff T. Cement augmentation of pedicle screw fixation using novel cannulated cement insertion device. Spine (Phila Pa 1976). 2009;34(14):E478\u201383.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"4","key":"2235_CR12","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1016\/j.orthres.2004.11.002","volume":"23","author":"CC Hsu","year":"2005","unstructured":"Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res. 2005;23(4):788\u201394.","journal-title":"J Orthop Res"},{"issue":"5","key":"2235_CR13","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1016\/j.spinee.2008.07.001","volume":"9","author":"A Hashemi","year":"2009","unstructured":"Hashemi A, Bednar D, Ziada S. Pullout strength of pedicle screws augmented with particulate calcium phosphate: an experimental study. Spine J. 2009;9(5):404\u201310.","journal-title":"Spine J"},{"key":"2235_CR14","first-page":"4924","volume":"2021","author":"H Makaram","year":"2021","unstructured":"Makaram H, Swaminathan R. Influence of bone quality and pedicle screw design on the fixation strength during Axial pull-out test: a 2D axisymmetric FE study. Annu Int Conf IEEE Eng Med Biol Soc. 2021;2021:4924\u20137.","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"6","key":"2235_CR15","doi-asserted-by":"publisher","first-page":"790e15","DOI":"10.1016\/j.ajodo.2007.12.020","volume":"133","author":"KK Salmoria","year":"2008","unstructured":"Salmoria KK, Tanaka OM, Guariza-Filho O, Camargo ES, de Souza LT, Maruo H. Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs. Am J Orthod Dentofacial Orthop. 2008;133(6):790e15\u201322.","journal-title":"Am J Orthod Dentofacial Orthop"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-023-02235-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-023-02235-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-023-02235-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T19:17:22Z","timestamp":1700335042000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-023-02235-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,18]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["2235"],"URL":"https:\/\/doi.org\/10.1186\/s12893-023-02235-9","relation":{},"ISSN":["1471-2482"],"issn-type":[{"type":"electronic","value":"1471-2482"}],"subject":[],"published":{"date-parts":[[2023,11,18]]},"assertion":[{"value":"24 March 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 October 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Medical Research Ethics Board of the General Hospital of Southern Theater Command of PLA. All methods were carried out in accordance with relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"354"}}