{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T21:15:06Z","timestamp":1757625306266,"version":"3.44.0"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Wire localization for nonpalpable breast lesions and pre-neoadjuvant chemotherapy (NAC) clips can lead to complications including wire migration, pneumothorax, and organ injury. This study evaluates the clinical efficacy and safety of a novel 3D-printed screw mechanism designed to prevent wire migration.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>This retrospective descriptive study included 104 patients with nonpalpable breast lesions and pre-NAC clips who underwent wire localization between March 2023 and August 2024. A screw mechanism was designed and manufactured using 3D printing technology with polylactic acid (PLA) material (4\u00a0g per device). The device features a 21.7\u00a0mm base diameter and elliptical wire hole (2.5\u2009\u00d7\u20094\u00a0mm). Wire stability and complications were assessed through imaging and clinical follow-up.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The median age was 47 years (range: 33\u201382) and median BMI was 24.7 (17.9\u201340.8). Lesions were primarily located in the upper outer quadrant (49.9%). Among 68 patients receiving NAC, 44.1% achieved pathological complete response (ypT0N0). The screw mechanism successfully prevented wire migration during patient transport from radiology to operating room in all 104 cases (0% migration rate, 95% CI: 0-3.6%). No complications including pneumothorax, organ injury, or skin reactions were observed. The device was easily removed by simple unscrewing on the operating table before surgical skin preparation. Median device application time was 2\u20134\u00a0h.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The 3D-printed screw mechanism effectively prevents wire migration and demonstrates excellent safety profile. Its simple design and ease of application make it a practical solution for improving patient safety during breast lesion localization procedures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration<\/jats:title>\n            <jats:p>Not applicable. This retrospective study did not require trial registration.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12893-025-03123-0","type":"journal-article","created":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T03:10:17Z","timestamp":1755659417000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A 3D-printed screw mechanism as an alternative method to prevent wire migration in nonpalpable breast lesion localization"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9289-2744","authenticated-orcid":false,"given":"Iksan","family":"Tasdelen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2341-3572","authenticated-orcid":false,"given":"Adnan","family":"Gundogdu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-7162-1992","authenticated-orcid":false,"given":"Kaan","family":"Celik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8418-0234","authenticated-orcid":false,"given":"Osman Cem","family":"Yilmaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6692-0828","authenticated-orcid":false,"given":"Levent","family":"Celik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,8,20]]},"reference":[{"key":"3123_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/cancers15041173","author":"M Banys-Paluchowski","year":"2023","unstructured":"Banys-Paluchowski M, K\u00fchn T, Masannat Y, Rubio I, de Boniface J, Ditsch N, et al. Localization techniques for non-palpable breast lesions: current status, knowledge gaps, and rationale for the MELODY study (EUBREAST-4\/iBRA-NET, NCT 05559411). Cancers (Basel). 2023. https:\/\/doi.org\/10.3390\/cancers15041173.","journal-title":"Cancers (Basel)"},{"issue":"3","key":"3123_CR2","doi-asserted-by":"publisher","first-page":"423","DOI":"10.2214\/AJR.21.26664","volume":"218","author":"MS Guirguis","year":"2022","unstructured":"Guirguis MS, Adrada BE, Scoggins ME, Moseley TW, Dryden MJ, Le-Petross HC, et al. The challenging image-guided preoperative breast localization: a modality-based approach. AJR Am J Roentgenol. 2022;218(3):423\u201334.","journal-title":"AJR Am J Roentgenol"},{"key":"3123_CR3","doi-asserted-by":"publisher","DOI":"10.1136\/bcr-2021-244086","author":"MO Joret","year":"2021","unstructured":"Joret MO, El-Haddawi F. Intraperitoneal migration of a hookwire following wide local excision of a breast lesion presenting as a spontaneous pneumothorax. BMJ Case Rep. 2021. https:\/\/doi.org\/10.1136\/bcr-2021-244086.","journal-title":"BMJ Case Rep"},{"issue":"7","key":"3123_CR4","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.3390\/medicina59071297","volume":"59","author":"S Shirazi","year":"2023","unstructured":"Shirazi S, Hajiesmaeili H, Khosla M, Taj S, Sircar T, Vidya R. Comparison of wire and non-wire localisation techniques in breast cancer surgery: a review of the literature with pooled analysis. Medicina (B Aires). 2023;59(7):1297.","journal-title":"Medicina (B Aires)"},{"issue":"3","key":"3123_CR5","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1093\/bjs\/znab443","volume":"109","author":"RV Dave","year":"2022","unstructured":"Dave RV, Barrett E, Morgan J, Chandarana M, Elgammal S, Barnes N, et al. Wire-and magnetic-seed-guided localization of impalpable breast lesions: iBRA-NET localisation study. Br J Surg. 2022;109(3):274\u201382.","journal-title":"Br J Surg"},{"issue":"Supplement8","key":"3123_CR6","first-page":"znae197","volume":"111","author":"KT Subramanian","year":"2024","unstructured":"Subramanian KT, Elnour A, Kurup V. SP6. 3-Comparison of three new wireless non-radiation techniques for localization of non-palpable breast cancer-an updated systematic review and pooled meta-analysis. Br J Surg. 2024;111(Supplement8):znae197.","journal-title":"Br J Surg"},{"issue":"2","key":"3123_CR7","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1111\/tbj.14146","volume":"27","author":"C Norman","year":"2021","unstructured":"Norman C, Lafaurie G, Uhercik M, Kasem A, Sinha P. Novel wire-free techniques for localization of impalpable breast lesions\u2014a review of current options. Breast J. 2021;27(2):141\u20138.","journal-title":"Breast J"},{"key":"3123_CR8","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1016\/j.ijbiomac.2021.07.074","volume":"186","author":"TL de Albuquerque","year":"2021","unstructured":"de Albuquerque TL, J\u00fanior JEM, de Queiroz LP, Ricardo ADS, Rocha MVP. Polylactic acid production from biotechnological routes: A review. Int J Biol Macromol. 2021;186:933\u201351.","journal-title":"Int J Biol Macromol"},{"issue":"3","key":"3123_CR9","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1080\/02841850410003085","volume":"45","author":"R Grassi","year":"2004","unstructured":"Grassi R, Romano S, Massimo M, Maglione M, Cusati B, Violini M. Unusual migration in abdomen of a wire for surgical localization of breast lesions. Acta Radiol. 2004;45(3):254\u20138.","journal-title":"Acta Radiol"},{"issue":"3","key":"3123_CR10","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1080\/00015458.2018.1523298","volume":"120","author":"N Bachir","year":"2020","unstructured":"Bachir N, Lemaitre J, Lardinois I. Intrathoracic hooked wire migration managed by minimally invasive thoracoscopic surgery. Acta Chir Belg. 2020;120(3):186\u20139.","journal-title":"Acta Chir Belg"},{"issue":"2","key":"3123_CR11","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1111\/tbj.12854","volume":"24","author":"M Da Silva","year":"2018","unstructured":"Da Silva M, Porembka J, Mokdad AA, Seiler S, Huth J, Rivers A, et al. Bracketed radioactive seed localization vs bracketed wire-localization in breast surgery. Breast J. 2018;24(2):161\u20136.","journal-title":"Breast J"},{"issue":"7","key":"3123_CR12","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1093\/bjs\/znaa160","volume":"108","author":"CM Wright","year":"2021","unstructured":"Wright CM, Moorin RE, Saunders C, Marinovich ML, Taylor DB, group tRs. Cost-effectiveness of radioguided occult lesion localization using 125I seeds versus hookwire localization before breast-conserving surgery for non-palpable breast cancer. Br J Surg. 2021;108(7):843\u201350.","journal-title":"Br J Surg"},{"issue":"4","key":"3123_CR13","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1177\/1553350620967853","volume":"28","author":"CM Cullinane","year":"2020","unstructured":"Cullinane CM, Byrne J, Akmenkalne L, O\u2019 Leary DP, Connors AM, Corrigan MA, et al. The localizer radiofrequency identification system: an effective new technology for localizing non-palpable breast lesions for surgery. Surg Innov. 2020;28(4):473\u20138.","journal-title":"Surg Innov"},{"issue":"4","key":"3123_CR14","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/j.crad.2022.01.034","volume":"77","author":"F Ross","year":"2022","unstructured":"Ross F, Elgammal S, Reid J, Henderson S, Kelly J, Flinn R, et al. Magseed localisation of non-palpable breast lesions: experience from a single centre. Clin Radiol. 2022;77(4):291\u20138.","journal-title":"Clin Radiol"},{"key":"3123_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.cson.2024.100051","author":"KT Subramanian","year":"2024","unstructured":"Subramanian KT, Elnour A, Kurup V. Comparison of three new wireless non-radiation techniques for localisation of non-palpable breast cancer-an updated systematic review and pooled meta-analysis. Clinical Surgical Oncology. 2024. https:\/\/doi.org\/10.1016\/j.cson.2024.100051.","journal-title":"Clinical Surgical Oncology"},{"key":"3123_CR16","doi-asserted-by":"crossref","unstructured":"Shirazi S, Hajiesmaeili H, Khosla M, Taj S, Sircar T, Vidya R. Comparison of wire and Non-Wire localisation techniques in breast cancer surgery: A review of the literature with pooled analysis. Med (Kaunas). 2023;59(7):1297.","DOI":"10.3390\/medicina59071297"},{"key":"3123_CR17","doi-asserted-by":"crossref","unstructured":"Keating J, Singhal S, editors. Novel methods of intraoperative localization and margin assessment of pulmonary nodules. Seminars in thoracic and cardiovascular surgery. Elsevier; 2016.","DOI":"10.1053\/j.semtcvs.2016.01.006"},{"issue":"1","key":"3123_CR18","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1186\/s12891-022-05550-z","volume":"23","author":"H Meng","year":"2022","unstructured":"Meng H, Xu B, Xu Y, Niu H, Liu N, Sun D. Treatment of distal radius fractures using a cemented K-wire frame. BMC Musculoskelet Disord. 2022;23(1):591.","journal-title":"BMC Musculoskelet Disord"},{"issue":"4","key":"3123_CR19","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1227\/NEU.0000000000000509","volume":"10","author":"C Dorfer","year":"2014","unstructured":"Dorfer C, Stefanits H, Pataraia E, Wolfsberger S, Feucht M, Baumgartner C, et al. Frameless stereotactic drilling for placement of depth electrodes in refractory epilepsy: operative technique and initial experience. Oper Neurosurg. 2014;10(4):582\u201391.","journal-title":"Oper Neurosurg"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-025-03123-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-025-03123-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-025-03123-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T17:52:24Z","timestamp":1757440344000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcsurg.biomedcentral.com\/articles\/10.1186\/s12893-025-03123-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,20]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3123"],"URL":"https:\/\/doi.org\/10.1186\/s12893-025-03123-0","relation":{},"ISSN":["1471-2482"],"issn-type":[{"type":"electronic","value":"1471-2482"}],"subject":[],"published":{"date-parts":[[2025,8,20]]},"assertion":[{"value":"13 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Ethics Committee of Sancaktepe \u015eehit Prof. Dr. \u0130lhan Varank Training and Research Hospital (Approval Number: 2024\/294). The need for informed consent was waived due to the retrospective nature of the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing financial interests. OCY is listed as one of the inventors on a pending patent application (TR 2023 018924) for the device described in this study. The other patent holders are not authors of this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"377"}}