{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:56:14Z","timestamp":1781646974879,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T00:00:00Z","timestamp":1775088000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T00:00:00Z","timestamp":1778630400000},"content-version":"vor","delay-in-days":41,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Surg"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Accurate screw placement is essential in spinal surgery. To enhance precision, navigation-guided techniques using fluoroscopy or computed tomography (CT) have been developed. Recently, overlay technology has emerged, enabling real-time projection of preoperative planning onto fluoroscopic images through C-arm\u2013based cone-beam CT (CBCT). Needle-guidance\u2013based overlay technology was applied to the surgical management of odontoid fractures and pedicle screw placement, with accuracy and clinical outcomes systematically evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A retrospective review was performed of three cases in which intraoperative overlay guidance using C-arm CBCT was considered effective for spinal surgery between February and June 2017. Case 1 involved a 26-year-old man with an Anderson type II odontoid fracture. Case 2 involved a 75-year-old woman with atlantoaxial dislocation. Case 3 involved a 66-year-old man with a vertebral arch fracture. For each case, postoperative imaging was used to assess the deviation between the planned trajectory and the actual implant position.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In Case 1, the deviation from the planned target point measured 2.57\u00a0mm. In Case 2, deviation were 0.71\u00a0mm (right C1), 0.98\u00a0mm (left C1), 0.35\u00a0mm (right C2), and 0.31\u00a0mm (left C2), producing a mean deviation of 0.59\u00a0mm. In Case 3, deviations were 0.88\u00a0mm (right L3), 2.21\u00a0mm (left L3), 2.37\u00a0mm (right L5), and 1.85\u00a0mm (left L5), resulting in a mean deviation of 1.83\u00a0mm. No major complications were observed in any of the three cases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Needle-guidance overlay technology extends beyond biopsy to encompass odontoid screw fixation and pedicle screw placement, demonstrating technical feasibility for accurate screw placement. In this study, implementation of the technique appeared to reduce the need for a separate navigation system without adding distinct invasive steps. It was also relatively straightforward to implement, suggesting feasibility even in smaller medical facilities.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12893-026-03709-2","type":"journal-article","created":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T03:03:27Z","timestamp":1775099007000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["C-arm cone beam computed tomography with needle path overlay during fluoroscopic-guided screw placement for a spinal lesion"],"prefix":"10.1186","volume":"26","author":[{"given":"Hiroki","family":"Ohashi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9187-068X","authenticated-orcid":false,"given":"Kohei","family":"Morita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daichi","family":"Kawamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keisuke","family":"Hatano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Satoshi","family":"Yamana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichi","family":"Murayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,2]]},"reference":[{"issue":"NA","key":"3709_CR1","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1097\/00003086-198101000-00010","volume":"154","author":"WR Selman","year":"1981","unstructured":"Selman WR, Spetzler RF, Brown R. The Use of Intraoperative Fluoroscopy and Spinal Cord Monitoring for Transoral Microsurgical Odontoid Resection. Clin Orthop Relat R. 1981;154(NA):51\u20136. https:\/\/doi.org\/10.1097\/00003086-198101000-00010.","journal-title":"Clin Orthop Relat R"},{"key":"3709_CR2","doi-asserted-by":"publisher","first-page":"223","DOI":"10.3171\/jns.1988.68.2.0223","volume":"68","author":"GM Borne","year":"1988","unstructured":"Borne GM, Bedou GL, Pinaudeau M, Cristino G, Hussein A. Odontoid process fracture osteosynthesis with a direct screw fixation technique in nine consecutive cases. J Neurosurg. 1988;68:223\u20136. https:\/\/doi.org\/10.3171\/jns.1988.68.2.0223.","journal-title":"J Neurosurg"},{"key":"3709_CR3","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1097\/00002517-199608000-00011","volume":"9","author":"CJ Odgers","year":"1996","unstructured":"Odgers CJ, Vaccaro AR, Pollack ME, Cotler JM. Accuracy of pedicle screw placement with the assistance of lateral plain radiography. J Spinal Disord. 1996;9:334\u20138. https:\/\/doi.org\/10.1097\/00002517-199608000-00011.","journal-title":"J Spinal Disord"},{"key":"3709_CR4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1002\/(sici)1097-0150(2000)5:1<18::aid-igs3>3.0.co;2-t","volume":"5","author":"N Haberland","year":"2000","unstructured":"Haberland N, Ebmeier K, Grunewald JP, Hliscs R, Kalff R. Incorporation of intraoperative computerized tomography in a newly developed spinal navigation technique. Comput Aided Surg. 2000;5:18\u201327. https:\/\/doi.org\/10.1002\/(sici)1097-0150(2000)5:1%3C;18::aid-igs3%3E;3.0.co;2-t.","journal-title":"Comput Aided Surg"},{"key":"3709_CR5","doi-asserted-by":"publisher","first-page":"331","DOI":"10.4184\/asj.2014.8.3.331","volume":"8","author":"T Kotani","year":"2014","unstructured":"Kotani T, Akazawa T, Sakuma T, Koyama K, Nemoto T, Nawata K, et al. Accuracy of pedicle screw placement in scoliosis surgery: a comparison between conventional computed tomography-based and O-Arm-Based navigation techniques. Asian Spine J. 2014;8:331\u20138. https:\/\/doi.org\/10.4184\/asj.2014.8.3.331.","journal-title":"Asian Spine J"},{"key":"3709_CR6","doi-asserted-by":"publisher","first-page":"2856","DOI":"10.1097\/01.brs.0000147742.20637.49","volume":"29","author":"JS Hott","year":"2004","unstructured":"Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VKH. Intraoperative iso-C C-arm navigation in cervical spinal surgery. Spine. 2004;29:2856\u201360. https:\/\/doi.org\/10.1097\/01.brs.0000147742.20637.49.","journal-title":"Spine"},{"key":"3709_CR7","doi-asserted-by":"publisher","first-page":"S54","DOI":"10.1097\/01.brs.0000076899.78522.d9","volume":"28","author":"LT Holly","year":"2003","unstructured":"Holly LT, Foley KT. Intraoperative spinal navigation. Spine. 2003;28:S54-61. https:\/\/doi.org\/10.1097\/01.brs.0000076899.78522.d9.","journal-title":"Spine"},{"key":"3709_CR8","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1097\/brs.0b013e3181bc39c6","volume":"35","author":"AL Tam","year":"2010","unstructured":"Tam AL, Mohamed A, Pfister M, Chinndurai P, Rohm E, Hall AF, et al. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty. Spine. 2010;35:1095\u20139. https:\/\/doi.org\/10.1097\/brs.0b013e3181bc39c6.","journal-title":"Spine"},{"key":"3709_CR9","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1097\/bsd.0b013e31805777da","volume":"21","author":"LE Summers","year":"2008","unstructured":"Summers LE, Kouri JG, Yang M, Jacob RP. Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy. J Spinal Disord Tech. 2008;21:45\u20138. https:\/\/doi.org\/10.1097\/bsd.0b013e31805777da.","journal-title":"J Spinal Disord Tech"},{"key":"3709_CR10","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1007\/s00234-011-0866-y","volume":"54","author":"SC Leschka","year":"2012","unstructured":"Leschka SC, Babic D, Shikh SE, Wossmann C, Schumacher M, Taschner CA. C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis. Neuroradiology. 2012;54:215\u201323. https:\/\/doi.org\/10.1007\/s00234-011-0866-y.","journal-title":"Neuroradiology"},{"key":"3709_CR11","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1007\/s00247-017-3830-0","volume":"47","author":"S Shellikeri","year":"2017","unstructured":"Shellikeri S, Setser RM, Hwang TJ, Srinivasan A, Krishnamurthy G, Vatsky S, et al. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children. Pediatr Radiol. 2017;47:963\u201373. https:\/\/doi.org\/10.1007\/s00247-017-3830-0.","journal-title":"Pediatr Radiol"},{"key":"3709_CR12","doi-asserted-by":"publisher","first-page":"e101","DOI":"10.1016\/j.ijcard.2007.11.049","volume":"133","author":"JA Garcia","year":"2009","unstructured":"Garcia JA, Bhakta S, Kay J, Chan K-C, Wink O, Ruijters D, et al. On-line multi-slice computed tomography interactive overlay with conventional X-ray: a new and advanced imaging fusion concept. Int J Cardiol. 2009;133:e101\u20135. https:\/\/doi.org\/10.1016\/j.ijcard.2007.11.049.","journal-title":"Int J Cardiol"},{"key":"3709_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2007.12.263","volume":"19","author":"N Maeda","year":"2008","unstructured":"Maeda N, Osuga K, Higashihara H, Tomoda K, Nakamura H. Abstract No. 237: A Novel Cone-Beam CT Guided Interventions by XperGuide: Accuracy and Feasibility in a Phantom Model. J Vasc Interv Radiol. 2008;19:S90. https:\/\/doi.org\/10.1016\/j.jvir.2007.12.263.","journal-title":"J Vasc Interv Radiol"},{"key":"3709_CR14","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1007\/s00586-012-2495-5","volume":"22","author":"JAK Ohnsorge","year":"2013","unstructured":"Ohnsorge JAK, Salem KH, Ladenburger A, Maus UM, Wei\u00dfkopf M. Computer-assisted fluoroscopic navigation of percutaneous spinal interventions. Eur Spine J. 2013;22:642\u20137. https:\/\/doi.org\/10.1007\/s00586-012-2495-5.","journal-title":"Eur Spine J"},{"key":"3709_CR15","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1007\/s11548-015-1252-8","volume":"11","author":"DF Malan","year":"2016","unstructured":"Malan DF, van der Walt SJ, Raidou RG, Berg B, Stoel BC, Botha CP, et al. A fluoroscopy-based planning and guidance software tool for minimally invasive hip refixation by cement injection. Int J Comput Assist Radiol. 2016;11:281\u201396. https:\/\/doi.org\/10.1007\/s11548-015-1252-8.","journal-title":"Int J Comput Assist Radiol"},{"key":"3709_CR16","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1148\/radiol.14131925","volume":"274","author":"V Tacher","year":"2015","unstructured":"Tacher V, Radaelli A, Lin M, Geschwind J-F. How i do it: cone-beam CT during transarterial chemoembolization for liver cancer. Radiology. 2015;274:320\u201334. https:\/\/doi.org\/10.1148\/radiol.14131925.","journal-title":"Radiology"},{"key":"3709_CR17","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1007\/s00270-008-9493-3","volume":"32","author":"A Tam","year":"2009","unstructured":"Tam A, Mohamed A, Pfister M, Rohm E, Wallace MJ. C-arm cone beam computed tomographic needle path overlay for fluoroscopic-guided placement of translumbar central venous catheters. Cardiovasc Intervent Radiol. 2009;32:820\u20134. https:\/\/doi.org\/10.1007\/s00270-008-9493-3.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"3709_CR18","doi-asserted-by":"publisher","unstructured":"Safaee M, Oh T, Pekmezci M, Clark AJ. Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion. J Vis Exp. 2019. https:\/\/doi.org\/10.3791\/57830.","DOI":"10.3791\/57830"},{"key":"3709_CR19","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1148\/radiol.2018181105","volume":"290","author":"C Roux","year":"2018","unstructured":"Roux C, Tselikas L, Yevich S, Solha RS, Hakime A, Teriitehau C, et al. Fluoroscopy and Cone-Beam CT\u2013guided Fixation by Internal Cemented Screw for Pathologic Pelvic Fractures. Radiology. 2018;290:418\u201325. https:\/\/doi.org\/10.1148\/radiol.2018181105.","journal-title":"Radiology"},{"key":"3709_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmir.2024.101831","volume":"56","author":"K Shirbache","year":"2025","unstructured":"Shirbache K, Heidarzadeh M, Qahremani R, Karami A, Karami S, Madreseh E, et al. A systematic review and meta-analysis of radiation exposure in spinal surgeries: comparing C-Arm, CT navigation, and O-Arm techniques. J Med Imaging Radiat Sci. 2025;56:101831. https:\/\/doi.org\/10.1016\/j.jmir.2024.101831.","journal-title":"J Med Imaging Radiat Sci"},{"key":"3709_CR21","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12010115","volume":"12","author":"L Yang","year":"2022","unstructured":"Yang L, Wang Y, Li L, Liu D, Wu X, Zhang W, et al. C-Arm cone-beam CT virtual navigation versus conventional CT guidance in the transthoracic lung biopsy: a case-control study. Diagnostics. 2022;12:115. https:\/\/doi.org\/10.3390\/diagnostics12010115.","journal-title":"Diagnostics"}],"container-title":["BMC Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12893-026-03709-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-026-03709-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12893-026-03709-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:21:33Z","timestamp":1781644893000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12893-026-03709-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,2]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3709"],"URL":"https:\/\/doi.org\/10.1186\/s12893-026-03709-2","relation":{},"ISSN":["1471-2482"],"issn-type":[{"value":"1471-2482","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,2]]},"assertion":[{"value":"8 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All patient information was anonymized before inclusion in the study. Approval was obtained from the Ethics Commission of our university (as #31\u2013060 [9559]).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"In this study, all participants\/patient gave written informed consent for their personal or clinical details.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"326"}}