{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T10:59:00Z","timestamp":1740135540179,"version":"3.37.3"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T00:00:00Z","timestamp":1590537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T00:00:00Z","timestamp":1590537600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Urol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>During transurethral resection of bladder tumours (TURB), radio-frequency (RF) currents can lead to adverse neuromuscular stimulation (NMS). Here we present a novel ex vivo method to determine the risk of RF generators and their bipolar TURB modes to cause NMS. We aimed to develop an experimental platform for safety evaluation of new RF generators and their modes with a newly established test standard, suitable for replacement or reduction of animal testing.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>We tested four contemporary RF generators with their bipolar modes for TURB in saline. A two-stage ex vivo approach was pursued: First, we recorded voltages at possible positions of the obturator nerve behind a porcine bladder wall in a TURB model using 18 RF applications per generator. Second, these voltage records were used as stimuli to evoke nerve compound action potentials (CAPs) in isolated porcine axillary nerves. The NMS potential was defined as the ratio between the observed area under the CAPs and the theoretical CAP area at maximum response and a firing rate of 250\u2009Hz, which would reliably induce tetanic muscle responses in most human subjects. The measurement protocol was tailored to optimise reproducibility of the obtained NMS potentials and longevity of the nerve specimens.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>As prerequisite for the clinical translation of our results, the robustness of our test method and reproducibility of the NMS potential are demonstrated with an excellent correlation (<jats:italic>r<\/jats:italic>\u2009=\u20090.93) between two sets of identical stimuli (<jats:italic>n<\/jats:italic>\u2009=\u200972 each) obtained from 16 nerve segments with similar diameters (4.2\u2009\u00b1\u20090.37\u2009mm) in the nerve model. The RF generators differed significantly (p\u2009&lt;\u20090.0001) regarding NMS potential (medians: 0\u20133%).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Our test method is suitable for quantifying the NMS potential of different electrosurgical systems ex vivo with high selectivity at a reasonable degree of standardization and with justifiable effort. Our results suggest that the clinical incidence of NMS is considerably influenced by the type of RF generator. Future generations of RF generators take advantage from the proposed test standard through higher safety and less animal testing. Health professionals and treated patients will benefit most from improved RF surgery using generators with a low NMS risk.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12894-020-00630-5","type":"journal-article","created":{"date-parts":[[2020,5,27]],"date-time":"2020-05-27T12:03:00Z","timestamp":1590580980000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Risk assessment of neuromuscular stimulation by energy-based transurethral resection devices: an ex vivo test standard"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9788-1761","authenticated-orcid":false,"given":"Ulrich","family":"Biber","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ovidiu","family":"Jurjut","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus D.","family":"Enderle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wilhelm K.","family":"Aicher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,5,27]]},"reference":[{"key":"630_CR1","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1007\/978-3-540-34103-1_28","volume-title":"Medizintechnik: Verfahren, Systeme, Informationsverarbeitung; mit 170 Tabellen","author":"B Hug","year":"2007","unstructured":"Hug B, Haag R. Hochfrequenzchirurgie. In: Kramme R, editor. Medizintechnik: Verfahren, Systeme, Informationsverarbeitung; mit 170 Tabellen. 3rd ed. Heidelberg: Springer; 2007. p. 515\u201338.","edition":"3"},{"key":"630_CR2","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1111\/j.1464-410X.2010.09903.x","volume":"108","author":"NP Gupta","year":"2011","unstructured":"Gupta NP, Saini AK, Dogra PN, Seth A, Kumar R. Bipolar energy for transurethral resection of bladder tumours at low-power settings: initial experience. BJU Int. 2011;108:553\u20136. https:\/\/doi.org\/10.1111\/j.1464-410X.2010.09903.x.","journal-title":"BJU Int"},{"key":"630_CR3","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1089\/end.2015.0410","volume":"30","author":"C Zhao","year":"2016","unstructured":"Zhao C, Tang K, Yang H, Xia D, Chen Z. Bipolar versus Monopolar transurethral resection of nonmuscle-invasive bladder Cancer: a meta-analysis. J Endourol. 2016;30:5\u201312. https:\/\/doi.org\/10.1089\/end.2015.0410.","journal-title":"J Endourol"},{"key":"630_CR4","first-page":"64","volume":"56","author":"RJ Prentiss","year":"1964","unstructured":"Prentiss RJ, Harvey GW, Bethard WF, Boatwright DE, Pennington RD. Massive adductor muscle contraction in transurethral surgery: cause and prevention; development of new electrical circuitry. Trans Am Assoc Genitourin Surg. 1964;56:64\u201372.","journal-title":"Trans Am Assoc Genitourin Surg"},{"key":"630_CR5","doi-asserted-by":"publisher","first-page":"284","DOI":"10.5173\/ceju.2015.565","volume":"68","author":"K Ozer","year":"2015","unstructured":"Ozer K, Horsanali MO, Gorgel SN, Ozbek E. Bladder injury secondary to obturator reflex is more common with plasmakinetic transurethral resection than monopolar transurethral resection of bladder cancer. Cent European J Urol. 2015;68:284\u20138. https:\/\/doi.org\/10.5173\/ceju.2015.565.","journal-title":"Cent European J Urol"},{"key":"630_CR6","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/S0952-8180(98)00069-5","volume":"10","author":"MS Shulman","year":"1998","unstructured":"Shulman MS, Vellayappan U, Monaghan TG, Coukos WJ, Krenis LJ. Simultaneous bilateral obturator nerve stimulation during transurethral electrovaporization of the prostate. J Clin Anesth. 1998;10:518\u201321.","journal-title":"J Clin Anesth"},{"key":"630_CR7","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1093\/annonc\/mdl498","volume":"18","author":"J Ferlay","year":"2007","unstructured":"Ferlay J, Autier P, Boniol M, Heanue M, Colombet M, Boyle P. Estimates of the cancer incidence and mortality in Europe in 2006. Ann Oncol. 2007;18:581\u201392. https:\/\/doi.org\/10.1093\/annonc\/mdl498.","journal-title":"Ann Oncol"},{"key":"630_CR8","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1089\/end.2012.0037","volume":"26","author":"M Khorrami","year":"2012","unstructured":"Khorrami M, Hadi M, Javid A, Izadpahani M-H, Mohammadi Sichani M, Zargham M, Alizadeh F. A comparison between blind and nerve stimulation guided obturator nerve block in transurethral resection of bladder tumor. J Endourol. 2012;26:1319\u201322. https:\/\/doi.org\/10.1089\/end.2012.0037.","journal-title":"J Endourol"},{"key":"630_CR9","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1016\/j.juro.2014.05.100","volume":"192","author":"T Sugihara","year":"2014","unstructured":"Sugihara T, Yasunaga H, Horiguchi H, Matsui H, Nishimatsu H, Nakagawa T, et al. Comparison of perioperative outcomes including severe bladder injury between monopolar and bipolar transurethral resection of bladder tumors: a population based comparison. J Urol. 2014;192:1355\u20139. https:\/\/doi.org\/10.1016\/j.juro.2014.05.100.","journal-title":"J Urol"},{"key":"630_CR10","doi-asserted-by":"publisher","first-page":"2665","DOI":"10.1097\/01.ju.0000031402.89232.e1","volume":"168","author":"H Shiozawa","year":"2002","unstructured":"Shiozawa H, Aizawa T, Ito T, Miki M. A new transurethral resection system: operating in saline environment precludes obturator nerve reflexes. J Urol. 2002;168:2665\u20137. https:\/\/doi.org\/10.1097\/01.ju.0000031402.89232.e1.","journal-title":"J Urol"},{"key":"630_CR11","doi-asserted-by":"publisher","first-page":"E780","DOI":"10.5489\/cuaj.3149","volume":"9","author":"D Bolat","year":"2015","unstructured":"Bolat D, Aydogdu O, Tekgul ZT, Polat S, Yonguc T, Bozkurt IH, et al. Impact of nerve stimulator-guided obturator nerve block on the short-term outcomes and complications of transurethral resection of bladder tumour: a prospective randomized controlled study. Can Urol Assoc J. 2015;9:E780\u20134. https:\/\/doi.org\/10.5489\/cuaj.3149.","journal-title":"Can Urol Assoc J"},{"key":"630_CR12","first-page":"529","volume":"81","author":"PG Atanassoff","year":"1995","unstructured":"Atanassoff PG, Weiss BM, Brull SJ, Horst A, K\u00fclling D, Stein R, Theiler I. Electromyographic comparison of obturator nerve block to three-in-one block. Anesth Analg. 1995;81:529\u201333.","journal-title":"Anesth Analg"},{"key":"630_CR13","first-page":"317","volume":"82","author":"PG Atanassoff","year":"1996","unstructured":"Atanassoff PG, Weiss BM, Brull SJ, Horst A, K\u00fclling D, Stein R, Theiler I. Compound motor action potential recording distinguishes differential onset of motor block of the obturator nerve in response to etidocaine or bupivacaine. Anesth Analg. 1996;82:317\u201320.","journal-title":"Anesth Analg"},{"key":"630_CR14","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1093\/bja\/41.8.695","volume":"41","author":"F Magora","year":"1969","unstructured":"Magora F, Rozin R, Ben-Menachem Y, Magora A. Obturator nerve block: an evaluation of technique. Br J Anaesth. 1969;41:695\u20138. https:\/\/doi.org\/10.1093\/bja\/41.8.695.","journal-title":"Br J Anaesth"},{"key":"630_CR15","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/978-3-642-01167-2_12","volume-title":"Endoskopische Urologie.","author":"M Burger","year":"2009","unstructured":"Burger M, Wieland W-F. Transurethrale Resektion der Blase. In: Hofmann R, editor. Endoskopische Urologie. Berlin: Springer Berlin Heidelberg; 2009. p. 151\u201363. https:\/\/doi.org\/10.1007\/978-3-642-01167-2_12."},{"key":"630_CR16","doi-asserted-by":"publisher","first-page":"1703","DOI":"10.1016\/j.juro.2013.12.004","volume":"191","author":"V Venkatramani","year":"2014","unstructured":"Venkatramani V, Panda A, Manojkumar R, Kekre NS. Monopolar versus bipolar transurethral resection of bladder tumors: a single center, parallel arm, randomized, controlled trial. J Urol. 2014;191:1703\u20137. https:\/\/doi.org\/10.1016\/j.juro.2013.12.004.","journal-title":"J Urol"},{"key":"630_CR17","doi-asserted-by":"publisher","first-page":"1699","DOI":"10.1007\/s11255-014-0719-9","volume":"46","author":"J Mashni","year":"2014","unstructured":"Mashni J, Godoy G, Haarer C, Dalbagni G, Reuter VE, Al-Ahmadie H, Bochner BH. Prospective evaluation of plasma kinetic bipolar resection of bladder cancer: comparison to monopolar resection and pathologic findings. Int Urol Nephrol. 2014;46:1699\u2013705. https:\/\/doi.org\/10.1007\/s11255-014-0719-9.","journal-title":"Int Urol Nephrol"},{"key":"630_CR18","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.eururo.2016.05.041","volume":"71","author":"M Babjuk","year":"2017","unstructured":"Babjuk M, Bohle A, Burger M, Capoun O, Cohen D, Comperat EM, et al. EAU guidelines on non-muscle-invasive Urothelial carcinoma of the bladder: update 2016. Eur Urol. 2017;71:447\u201361. https:\/\/doi.org\/10.1016\/j.eururo.2016.05.041.","journal-title":"Eur Urol"},{"key":"630_CR19","doi-asserted-by":"publisher","first-page":"852","DOI":"10.1177\/0003489415588556","volume":"124","author":"G Tirelli","year":"2015","unstructured":"Tirelli G, Camilot D, Bonini P, Del Piero GC, Biasotto M, Quatela E. Harmonic scalpel and Electrothermal bipolar vessel sealing system in head and neck surgery: a prospective study on tissue heating and histological damage on nerves. Ann Otol Rhinol Laryngol. 2015;124:852\u20138. https:\/\/doi.org\/10.1177\/0003489415588556.","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"630_CR20","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1109\/TBME.1985.325636","volume":"32","author":"JR Lacourse","year":"1985","unstructured":"Lacourse JR, Miller WT, Vogt M, Selikowitz SM. Effect of high-frequency current on nerve and muscle tissue. IEEE Trans Biomed Eng. 1985;32:82\u20136. https:\/\/doi.org\/10.1109\/TBME.1985.325636.","journal-title":"IEEE Trans Biomed Eng"},{"key":"630_CR21","unstructured":"Lapicque L. Recherches quantitatives sur l'excitation \u00e9lectrique des nerfs trait\u00e9e comme une polarization. J Physiol Pathol Gen. 1907;9:620\u201335."},{"key":"630_CR22","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.neuro.2015.10.016","volume":"52","author":"G Zafeiridou","year":"2016","unstructured":"Zafeiridou G, Spilioti M, Kagiava A, Krikonis K, Kosmidis EK, Karlovasitou A, Kimiskidis VK. Differential effects of lacosamide, phenytoin and topiramate on peripheral nerve excitability: an ex vivo electrophysiological study. Neurotoxicology. 2016;52:57\u201363. https:\/\/doi.org\/10.1016\/j.neuro.2015.10.016.","journal-title":"Neurotoxicology."},{"key":"630_CR23","doi-asserted-by":"publisher","first-page":"634","DOI":"10.3109\/15376516.2013.825826","volume":"23","author":"A Kagiava","year":"2013","unstructured":"Kagiava A, Theophilidis G. Assessing the permeability of the rat sciatic nerve epineural sheath against compounds with local anesthetic activity: an ex vivo electrophysiological study. Toxicol Mech Methods. 2013;23:634\u201340. https:\/\/doi.org\/10.3109\/15376516.2013.825826.","journal-title":"Toxicol Mech Methods"},{"key":"630_CR24","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1016\/j.jneumeth.2005.12.007","volume":"154","author":"J Li","year":"2006","unstructured":"Li J, Shi R. A device for the electrophysiological recording of peripheral nerves in response to stretch. J Neurosci Methods. 2006;154:102\u20138. https:\/\/doi.org\/10.1016\/j.jneumeth.2005.12.007.","journal-title":"J Neurosci Methods"},{"key":"630_CR25","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1016\/j.toxicon.2011.12.007","volume":"59","author":"A Kagiava","year":"2012","unstructured":"Kagiava A, Aligizaki K, Katikou P, Nikolaidis G, Theophilidis G. Assessing the neurotoxic effects of palytoxin and ouabain, both Na+\/K+-ATPase inhibitors, on the myelinated sciatic nerve fibres of the mouse: an ex vivo electrophysiological study. Toxicon. 2012;59:416\u201326. https:\/\/doi.org\/10.1016\/j.toxicon.2011.12.007.","journal-title":"Toxicon"},{"key":"630_CR26","doi-asserted-by":"publisher","unstructured":"Dideriksen JL, Leerskov K, Czyzewska M, Rasmussen R. The relation between the frequency of short-pulse electrical stimulation of afferent nerve fibers and evoked muscle force. IEEE Trans Biomed Eng. 2017. https:\/\/doi.org\/10.1109\/TBME.2017.2671853.","DOI":"10.1109\/TBME.2017.2671853"},{"key":"630_CR27","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1113\/jphysiol.1978.sp012273","volume":"277","author":"JR Blinks","year":"1978","unstructured":"Blinks JR, Rudel R, Taylor SR. Calcium transients in isolated amphibian skeletal muscle fibres: detection with aequorin. J Physiol. 1978;277:291\u2013323.","journal-title":"J Physiol"},{"key":"630_CR28","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1088\/0967-3334\/33\/7\/1249","volume":"33","author":"KF Dobiszewski","year":"2012","unstructured":"Dobiszewski KF, Deek MP, Ghaly A, Prodan C, Hill AA. Extracellular fluid conductivity analysis by dielectric spectroscopy for in vitro determination of cortical tissue vitality. Physiol Meas. 2012;33:1249\u201360. https:\/\/doi.org\/10.1088\/0967-3334\/33\/7\/1249.","journal-title":"Physiol Meas"},{"key":"630_CR29","volume-title":"Advances in swine in biomedical research","author":"LB Schook","year":"1996","unstructured":"Schook LB, Tumbleson ME. Advances in swine in biomedical research. New York: Plenum Press; 1996."},{"key":"630_CR30","doi-asserted-by":"publisher","first-page":"179","DOI":"10.7150\/ijbs.3.179","volume":"3","author":"JK Lunney","year":"2007","unstructured":"Lunney JK. Advances in swine biomedical model genomics. Int J Biol Sci. 2007;3:179\u201384. https:\/\/doi.org\/10.7150\/ijbs.3.179.","journal-title":"Int J Biol Sci"},{"key":"630_CR31","doi-asserted-by":"publisher","first-page":"339","DOI":"10.3389\/fnins.2017.00339","volume":"11","author":"S He","year":"2017","unstructured":"He S, Teagle HFB, Buchman CA. The electrically evoked compound action potential: from laboratory to clinic. Front Neurosci. 2017;11:339. https:\/\/doi.org\/10.3389\/fnins.2017.00339.","journal-title":"Front Neurosci"},{"key":"630_CR32","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1159\/000137752","volume":"25","author":"JC S\u00e1ez","year":"1982","unstructured":"S\u00e1ez JC, Norris B, Concha J. Effect of colchicine on the electrophysiological properties of the toad sciatic-gastrocnemius preparations in vivo. Pharmacology. 1982;25:278\u201385. https:\/\/doi.org\/10.1159\/000137752.","journal-title":"Pharmacology"},{"key":"630_CR33","first-page":"403","volume":"12","author":"G Bir\u00f3","year":"1977","unstructured":"Bir\u00f3 G. Excitatory effects of the electrical activity of muscle on the contiguous nerve. Acta Biochim Biophys Acad Sci Hung. 1977;12:403\u201310.","journal-title":"Acta Biochim Biophys Acad Sci Hung"},{"key":"630_CR34","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/0306-3623(90)90901-W","volume":"21","author":"MA Maleque","year":"1990","unstructured":"Maleque MA, Adhikary PK, Pavuluri S, Kopsombut P, Rucker HK. Potentiation of cholinergic activity with pyridino1,2-aimidazo5,4-bindole: in vitro studies. Gen Pharmacol. 1990;21:199\u2013203.","journal-title":"Gen Pharmacol"},{"key":"630_CR35","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1109\/10.212058","volume":"40","author":"CJ Slager","year":"1993","unstructured":"Slager CJ, Schuurbiers JC, Oomen JA, Bom N. Electrical nerve and muscle stimulation by radio frequency surgery: role of direct current loops around the active electrode. IEEE Trans Biomed Eng. 1993;40:182\u20137. https:\/\/doi.org\/10.1109\/10.212058.","journal-title":"IEEE Trans Biomed Eng"}],"container-title":["BMC Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-020-00630-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12894-020-00630-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-020-00630-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,26]],"date-time":"2021-05-26T23:19:31Z","timestamp":1622071171000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcurol.biomedcentral.com\/articles\/10.1186\/s12894-020-00630-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,27]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["630"],"URL":"https:\/\/doi.org\/10.1186\/s12894-020-00630-5","relation":{},"ISSN":["1471-2490"],"issn-type":[{"type":"electronic","value":"1471-2490"}],"subject":[],"published":{"date-parts":[[2020,5,27]]},"assertion":[{"value":"19 June 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"UB, OJ and MDE are employees of Erbe Elektromedizin GmbH (Sponsor). Otherwise, the authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"59"}}