{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T04:15:33Z","timestamp":1794370533912,"version":"4.9.0"},"reference-count":90,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T00:00:00Z","timestamp":1663545600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T00:00:00Z","timestamp":1663545600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Urol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>For patients suffering from urinary retention due to neurogenic [e.g., spinal cord injury (SCI), spina bifida (SB), multiple sclerosis (MS)] or non-neurogenic [e.g., cancer, benign prostate hypertrophy (BPH)] causes, intermittent catheterization is the primary choice for bladder emptying. This scoping review compared hydrophilic-coated intermittent catheters (HCICs) with non-hydrophilic (uncoated) catheters in neurogenic and non-neurogenic patients with respect to satisfaction, preference, adverse events, urinary tract infection (UTI), quality of life (QoL), cost effectiveness, pain, and discomfort.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A systematic literature search was conducted using PubMed, Cochrane Library, Google Scholar, Embase, and available clinical practice guidelines and was limited to systematic reviews\/meta-analysis and clinical studies (randomized trials, cohort and case\u2013control studies) published in English between 2000 and 2020. A narrative synthesis was performed, comparing HCIC with non-hydrophilic catheters in each pathology. The articles where critically appraised and weighted according to their level of evidence based on the Oxford Centre for Evidence-Based Medicine Levels of Evidence grading.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Thirty seven original articles and 40 reviews were included. The comparison of HCICs versus non-hydrophilic catheters was well-documented in patients with mixed pathology, SCI, and to some extent SB. The available evidence predominantly indicates better outcomes with HCICs as reported by study authors, particularly, greater UTI reduction and improved satisfaction, cost-effectiveness, and QoL. However, SB studies in children did not report reduction in UTIs. Children complained about slippery catheters, indicating possible touching of the surface during insertion, which may compromise cleanliness of the procedure and affect outcomes such as UTI. Limited studies were available exclusively on BPH and none on MS; however, most studies performed on mixed pathologies, including BPH and MS, indicated strong preference for HCICs compared to non-hydrophilic catheters.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The findings generally support HCICs over non-hydrophilic catheters; however, most studies were fairly small, often used a mix of pathologies, and the conclusions were often based on studies with high drop-out rates that were therefore underpowered. Larger studies are needed to support the general finding that HCICs are the preferred choice in most populations. Additional training in children or redesigned catheters may be necessary for this age-group to fully benefit from the advantages of HCICs.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12894-022-01102-8","type":"journal-article","created":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T19:05:40Z","timestamp":1663614340000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["A scoping review on the impact of hydrophilic versus non-hydrophilic intermittent catheters on UTI, QoL, satisfaction, preference, and other outcomes in neurogenic and non-neurogenic patients suffering from urinary retention"],"prefix":"10.1186","volume":"22","author":[{"given":"Kim Bundvig","family":"Barken","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rikke","family":"Vaabengaard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,9,19]]},"reference":[{"issue":"5","key":"1102_CR1","first-page":"643","volume":"77","author":"BA Selius","year":"2008","unstructured":"Selius BA, Subedi R. Urinary retention in adults: diagnosis and initial management. Am Fam Phys. 2008;77(5):643\u201350.","journal-title":"Am Fam Phys"},{"issue":"3","key":"1102_CR2","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1016\/S0022-5347(17)61055-3","volume":"107","author":"J Lapides","year":"1972","unstructured":"Lapides J, Diokno AC, Silber SJ, Lowe BS. Clean, intermittent self-catheterization in the treatment of urinary tract disease. J Urol. 1972;107(3):458\u201361.","journal-title":"J Urol"},{"key":"1102_CR3","first-page":"3","volume":"6","author":"BGSP Vickrey","year":"1999","unstructured":"Vickrey BGSP, Morton S, Clark K, Pathak M, Kamberg C. Prevention and management of urinary tract infections in paralyzed persons. Evid Rep Technol Assess (Summ). 1999;6:3.","journal-title":"Evid Rep Technol Assess (Summ)"},{"issue":"5","key":"1102_CR4","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1016\/j.asjsur.2019.12.009","volume":"43","author":"D Feng","year":"2020","unstructured":"Feng D, Cheng L, Bai Y, Yang Y, Han P. Outcomes comparison of hydrophilic and non-hydrophilic catheters for patients with intermittent catheterization: an updated meta-analysis. Asian J Surg. 2020;43(5):633\u20135.","journal-title":"Asian J Surg"},{"issue":"1","key":"1102_CR5","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s12894-016-0191-1","volume":"17","author":"C Rognoni","year":"2017","unstructured":"Rognoni C, Tarricone R. Intermittent catheterisation with hydrophilic and non-hydrophilic urinary catheters: systematic literature review and meta-analyses. BMC Urol. 2017;17(1):4.","journal-title":"BMC Urol"},{"issue":"7","key":"1102_CR6","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1038\/sc.2016.192","volume":"55","author":"S Shamout","year":"2017","unstructured":"Shamout S, Biardeau X, Corcos J, Campeau L. Outcome comparison of different approaches to self-intermittent catheterization in neurogenic patients: a systematic review. Spinal Cord. 2017;55(7):629\u201343.","journal-title":"Spinal Cord"},{"issue":"6","key":"1102_CR7","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1038\/s41393-021-00620-w","volume":"59","author":"D Ye","year":"2021","unstructured":"Ye D, Chen Y, Jian Z, Liao B, Jin X, Xiang L, et al. Catheters for intermittent catheterization: a systematic review and network meta-analysis. Spinal Cord. 2021;59(6):587\u201395.","journal-title":"Spinal Cord"},{"issue":"4","key":"1102_CR8","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1016\/j.apmr.2012.11.010","volume":"94","author":"L Li","year":"2013","unstructured":"Li L, Ye W, Ruan H, Yang B, Zhang S, Li L. Impact of hydrophilic catheters on urinary tract infections in people with spinal cord injury: systematic review and meta-analysis of randomized controlled trials. Arch Phys Med Rehabil. 2013;94(4):782\u20137.","journal-title":"Arch Phys Med Rehabil"},{"key":"1102_CR9","unstructured":"Oxford_Centre_for_Evidence-Based_Medicine:_Levels_of_Evidence. https:\/\/www.cebm.ox.ac.uk\/resources\/levels-of-evidence\/oxford-centre-for-evidence-based-medicine-levels-of-evidence-march-2009. Accessed 13 Aug 2021."},{"issue":"4","key":"1102_CR10","first-page":"10","volume":"22","author":"M Yoshida","year":"2018","unstructured":"Yoshida M, Igawa Y, Higashimura S, Suzuki M, Sanada H. Effectiveness of a hydrophilic-coated compact catheter in preventing urinary tract infections and improving quality of life in female patients managed with a clean intermittent self-catheterization: A prospective multicenter randomized parallel comparative trial. J Jpn Soc Wound Ostomy Cont Manag. 2018;22(4):10.","journal-title":"J Jpn Soc Wound Ostomy Cont Manag"},{"issue":"6","key":"1102_CR11","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1016\/j.jpurol.2019.10.001","volume":"15","author":"T Burki","year":"2019","unstructured":"Burki T, Abasher A, Alshahrani A, Al Hams AW, Ibrahim H, Albadawe H, et al. Complications and patient satisfaction with urethral clean intermittent catheterization in spina bifida patients: comparing coated vs uncoated catheters. J Pediatr Urol. 2019;15(6):646\u201350.","journal-title":"J Pediatr Urol"},{"issue":"1","key":"1102_CR12","first-page":"21","volume":"5","author":"A Spinu","year":"2012","unstructured":"Spinu A, Onose G, Daia C, Pantu C, Anghelescu A, Onose L, et al. Intermittent catheterization in the management of post spinal cord injury (SCI) neurogenic bladder using new hydrophilic, with lubrication in close circuit devices\u2013our own preliminary results. J Med Life. 2012;5(1):21\u20138.","journal-title":"J Med Life"},{"issue":"4 Pt 2","key":"1102_CR13","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1097\/01.ju.0000138847.14680.7d","volume":"172","author":"B Lindehall","year":"2004","unstructured":"Lindehall B, Abrahamsson K, Hjalmas K, Jodal U, Olsson I, Sillen U. Complications of clean intermittent catheterization in boys and young males with neurogenic bladder dysfunction. J Urol. 2004;172(4 Pt 2):1686\u20138.","journal-title":"J Urol"},{"issue":"5","key":"1102_CR14","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.pmrj.2011.01.001","volume":"3","author":"DD Cardenas","year":"2011","unstructured":"Cardenas DD, Moore KN, Dannels-McClure A, Scelza WM, Graves DE, Brooks M, et al. Intermittent catheterization with a hydrophilic-coated catheter delays urinary tract infections in acute spinal cord injury: a prospective, randomized, multicenter trial. PM R. 2011;3(5):408\u201317.","journal-title":"PM R"},{"issue":"2","key":"1102_CR15","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1038\/sj.sc.3100958","volume":"38","author":"J Wyndaele","year":"2000","unstructured":"Wyndaele J, De Ridder D, Everaert K, Heilporn A, Congard-Chassol B. Evaluation of the use of Urocath-Gel catheters for intermittent self-catheterization by male patients using conventional catheters for a long time. Spinal Cord. 2000;38(2):97\u20139.","journal-title":"Spinal Cord"},{"issue":"1","key":"1102_CR16","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.eururo.2006.11.041","volume":"52","author":"TB Johansen","year":"2007","unstructured":"Johansen TB, Hultling C, Madersbacher H, del Popolo G, Amarenco G, Group LPS. A novel product for intermittent catheterisation: its impact on compliance with daily life\u2014international multicentre study. Eur Urol. 2007;52(1):213\u201320.","journal-title":"Eur Urol"},{"issue":"4","key":"1102_CR17","first-page":"8","volume":"46","author":"S Sarica","year":"2010","unstructured":"Sarica S, Akkoc Y, Karapolat H, Aktug H. Comparison of the use of conventional, hydrophilic and gel-lubricated catheters with regard to urethral micro trauma, urinary system infection, and patient satisfaction in patients with spinal cord injury: a randomized controlled study. Eur J Phys Rehabil Med. 2010;46(4):8.","journal-title":"Eur J Phys Rehabil Med"},{"issue":"11","key":"1102_CR18","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1503\/cmaj.141044","volume":"187","author":"A Salameh","year":"2015","unstructured":"Salameh A, Al Mohajer M, Daroucihe RO. Prevention of urinary tract infections in patients with spinal cord injury. CMAJ. 2015;187(11):807\u201311.","journal-title":"CMAJ"},{"issue":"4","key":"1102_CR19","doi-asserted-by":"publisher","first-page":"373 e1","DOI":"10.1016\/j.jpurol.2017.06.003","volume":"13","author":"W DeFoor","year":"2017","unstructured":"DeFoor W, Reddy P, Reed M, VanderBrink B, Jackson E, Zhang B, et al. Results of a prospective randomized control trial comparing hydrophilic to uncoated catheters in children with neurogenic bladder. J Pediatr Urol. 2017;13(4):373 e1-373 e5.","journal-title":"J Pediatr Urol"},{"issue":"1","key":"1102_CR20","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1016\/j.juro.2014.12.096","volume":"194","author":"D Kiddoo","year":"2015","unstructured":"Kiddoo D, Sawatzky B, Bascu CD, Dharamsi N, Afshar K, Moore KN. Randomized crossover trial of single use hydrophilic coated vs multiple use polyvinylchloride catheters for intermittent catheterization to determine incidence of urinary infection. J Urol. 2015;194(1):174\u20139.","journal-title":"J Urol"},{"issue":"3\u20134","key":"1102_CR21","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1111\/j.1365-2702.2012.04066.x","volume":"22","author":"HE Chick","year":"2013","unstructured":"Chick HE, Hunter KF, Moore KN. Parent and child experiences using a hydrophilic or reused PVC catheter for intermittent catheterisation. J Clin Nurs. 2013;22(3\u20134):513\u201320.","journal-title":"J Clin Nurs"},{"issue":"7","key":"1102_CR22","doi-asserted-by":"publisher","first-page":"767","DOI":"10.1046\/j.1464-410x.1999.00013.x","volume":"83","author":"J Pachler","year":"1999","unstructured":"Pachler J, Frimodt-Moller C. A comparison of prelubricated hydrophilic and non-hydrophilic polyvinyl chloride catheters for urethral catheterization. BJU Int. 1999;83(7):767\u20139.","journal-title":"BJU Int"},{"issue":"1","key":"1102_CR23","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1159\/000078798","volume":"73","author":"L Cindolo","year":"2004","unstructured":"Cindolo L, Palmieri EA, Autorino R, Salzano L, Altieri V. Standard versus hydrophilic catheterization in the adjuvant treatment of patients with superficial bladder cancer. Urol Int. 2004;73(1):19\u201322.","journal-title":"Urol Int"},{"issue":"6","key":"1102_CR24","doi-asserted-by":"publisher","first-page":"991","DOI":"10.1016\/j.eururo.2005.07.018","volume":"48","author":"DJ De Ridder","year":"2005","unstructured":"De Ridder DJ, Everaert K, Fernandez LG, Valero JV, Duran AB, Abrisqueta ML, et al. Intermittent catheterisation with hydrophilic-coated catheters (SpeediCath) reduces the risk of clinical urinary tract infection in spinal cord injured patients: a prospective randomised parallel comparative trial. Eur Urol. 2005;48(6):991\u20135.","journal-title":"Eur Urol"},{"issue":"6","key":"1102_CR25","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1016\/j.eururo.2005.07.009","volume":"48","author":"J Stensballe","year":"2005","unstructured":"Stensballe J, Looms D, Nielsen PN, Tvede M. Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters. Eur Urol. 2005;48(6):978\u201383.","journal-title":"Eur Urol"},{"key":"1102_CR26","first-page":"CD006008","volume":"9","author":"J Prieto","year":"2014","unstructured":"Prieto J, Murphy CL, Moore KN, Fader M. Intermittent catheterisation for long-term bladder management. Cochrane Database Syst Rev. 2014;9:CD006008.","journal-title":"Cochrane Database Syst Rev"},{"issue":"3","key":"1102_CR27","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1097\/01.ju.0000051160.72187.e9","volume":"169","author":"JM Vapnek","year":"2003","unstructured":"Vapnek JM, Maynard FM, Kim J. A prospective randomized trial of the LoFric hydrophilic coated catheter versus conventional plastic catheter for clean intermittent catheterization. J Urol. 2003;169(3):994\u20138.","journal-title":"J Urol"},{"issue":"1","key":"1102_CR28","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1080\/00365590151030822","volume":"35","author":"H Hedlund","year":"2001","unstructured":"Hedlund H, Hjelmas K, Jonsson O, Klarskov P, Talja M. Hydrophilic versus non-coated catheters for intermittent catheterization. Scand J Urol Nephrol. 2001;35(1):49\u201353.","journal-title":"Scand J Urol Nephrol"},{"key":"1102_CR29","unstructured":"Abrams P, Cardozo L, Wagg A, Wein A (Eds). Incontinence 6th Edition. ICI-ICS International Continence Society, Bristol UK, ISBN: 978\u20130956960733; 2017."},{"issue":"3","key":"1102_CR30","first-page":"347","volume":"16","author":"A Leriche","year":"2006","unstructured":"Leriche A, Charvier K, Bonniaud V, Peyrat L, N\u2019Guyen P, Soler J-M, et al. Etude d\u2019acceptabilit\u00e9 du set de sondage SpeediCath\u00ae Set comparativement \u00e0 Actreen\u00ae Set chez des patients pratiquant l\u2019autosondage. Prog Urol. 2006;16(3):347.","journal-title":"Prog Urol"},{"issue":"1","key":"1102_CR31","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1002\/nau.20929","volume":"30","author":"E Chartier-Kastler","year":"2011","unstructured":"Chartier-Kastler E, Denys P. Intermittent catheterization with hydrophilic catheters as a treatment of chronic neurogenic urinary retention. Neurourol Urodyn. 2011;30(1):21\u201331.","journal-title":"Neurourol Urodyn"},{"issue":"8","key":"1102_CR32","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1007\/s11255-020-02435-9","volume":"52","author":"DK Newman","year":"2020","unstructured":"Newman DK, New PW, Heriseanu R, Petronis S, Hakansson J, Hakansson MA, et al. Intermittent catheterization with single- or multiple-reuse catheters: clinical study on safety and impact on quality of life. Int Urol Nephrol. 2020;52(8):1443\u201351.","journal-title":"Int Urol Nephrol"},{"key":"1102_CR33","unstructured":"Medical_Advisory_Secretariat. Hydrophilic catheters: an evidence-based analysis. Ontario Health Technology Assessment Series. 2006;6(9):1."},{"issue":"6","key":"1102_CR34","doi-asserted-by":"publisher","first-page":"5","DOI":"10.5489\/cuaj.09138","volume":"4","author":"A Boucher","year":"2010","unstructured":"Boucher A, Cloutier J, Lebel S, Hamel M, Lamontagne P, Bolduc S. Hydrophilic-coated catheter appreciation study in a pediatric population. Can Urol Assoc J. 2010;4(6):5.","journal-title":"Can Urol Assoc J"},{"issue":"1","key":"1102_CR35","first-page":"S261","volume":"28","author":"T Yamanishi","year":"2017","unstructured":"Yamanishi T, Kaga K, Kaga M, Fuse M. Randomized, cross-over study comparing hydrophilic compact catheters vs. standard catheters for using intermittent self catheterization. Int Urogynecol J. 2017;28(1):S261.","journal-title":"Int Urogynecol J"},{"key":"1102_CR36","first-page":"S135","volume":"2018","author":"DK Newman","year":"2018","unstructured":"Newman DK, O\u2019Connor RC, Clark R, Heriseanu R, Chung E, New P, et al. Intermittent catheter choice impacts quality of life: clinical study on safety and preference of single vs reuse catheters. Neurourol Urodyn Suppl ICS. 2018;2018:S135\u20136.","journal-title":"Neurourol Urodyn Suppl ICS"},{"key":"1102_CR37","first-page":"381","volume":"9","author":"B Pinder","year":"2015","unstructured":"Pinder B, Lloyd AJ, Nafees B, Elkin EP, Marley J. Patient preferences and willingness to pay for innovations in intermittent self-catheters. Patient Prefer Adherence. 2015;9:381\u20138.","journal-title":"Patient Prefer Adherence"},{"issue":"3","key":"1102_CR38","doi-asserted-by":"publisher","first-page":"172 e1","DOI":"10.1016\/j.jpurol.2015.12.012","volume":"12","author":"EJ Lucas","year":"2016","unstructured":"Lucas EJ, Baxter C, Singh C, Mohamed AZ, Li B, Zhang J, et al. Comparison of the microbiological milieu of patients randomized to either hydrophilic or conventional PVC catheters for clean intermittent catheterization. J Pediatr Urol. 2016;12(3):172 e1-172 e8.","journal-title":"J Pediatr Urol"},{"issue":"6","key":"1102_CR39","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1016\/S0022-5347(01)65430-2","volume":"156","author":"RS Sutherland","year":"1996","unstructured":"Sutherland RS, Kogan BA, Baskin LS, Mevorach RA. Clean intermittent catheterization in boys using the LoFric catheter. J Urol. 1996;156(6):2041\u20133.","journal-title":"J Urol"},{"issue":"4","key":"1102_CR40","first-page":"229","volume":"15","author":"V Samal","year":"2011","unstructured":"Samal V, Kyrianova A, Sram J, Mecl J, Fogl J. Clean intermittent catheterization in the treatment of neurogenic dysfunctions of the lower urinary tract after spinal cord injury-comparison of the results of hydrophilic-coated and standard PVC catheters. Ceska Urol. 2011;15(4):229\u201336.","journal-title":"Ceska Urol"},{"issue":"6","key":"1102_CR41","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1007\/s11908-011-0208-6","volume":"13","author":"F D'Hondt","year":"2011","unstructured":"D\u2019Hondt F, Everaert K. Urinary tract infections in patients with spinal cord injuries. Curr Infect Dis Rep. 2011;13(6):544\u201351.","journal-title":"Curr Infect Dis Rep"},{"issue":"3","key":"1102_CR42","first-page":"195","volume":"109","author":"F Theron","year":"2019","unstructured":"Theron F, Wilson V, Scriba E, Campbell R, van Zyl M, Terry D, et al. Best practice recommendations for bladder management in spinal cord-afflicted patients in South Africa. S Afr Med J. 2019;109(3):195\u2013202.","journal-title":"S Afr Med J"},{"issue":"4","key":"1102_CR43","first-page":"651","volume":"47","author":"P Di Benedetto","year":"2011","unstructured":"Di Benedetto P. Clean intermittent self-catheterization in neuro-urology. Eur J Phys Rehabil Med. 2011;47(4):651\u20139.","journal-title":"Eur J Phys Rehabil Med"},{"issue":"2","key":"1102_CR44","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1097\/00005392-199502000-00014","volume":"153","author":"L Waller","year":"1995","unstructured":"Waller L, Jonsson O, Norlen L, Sullivan L. Clean intermittent catheterization in spinal cord injury patients: long-term followup of a hydrophilic low friction technique. J Urol. 1995;153(2):345\u20138.","journal-title":"J Urol"},{"issue":"7","key":"1102_CR45","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1038\/sc.2014.79","volume":"52","author":"MA Hakansson","year":"2014","unstructured":"Hakansson MA. Reuse versus single-use catheters for intermittent catheterization: What is safe and preferred? Rev Curr Status Spinal Cord. 2014;52(7):511\u20136.","journal-title":"Rev Curr Status Spinal Cord"},{"issue":"10","key":"1102_CR46","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1038\/sj.sc.3101348","volume":"40","author":"JJ Wyndaele","year":"2002","unstructured":"Wyndaele JJ. Complications of intermittent catheterization: their prevention and treatment. Spinal Cord. 2002;40(10):536\u201341.","journal-title":"Spinal Cord"},{"key":"1102_CR47","unstructured":"Vahr S, Cobussen-Boekhorst H, Eikenboom J, Geng V, Holroyd S, Lester M, et al. Evidence-based guidelines for best practice in urological health care catheterisation urethral intermittent in adults dilatation, urethral intermittent in adults. EAUN. ISBN: 978-90-79754-59-5; 2013."},{"key":"1102_CR48","doi-asserted-by":"publisher","first-page":"2757862","DOI":"10.1155\/2019\/2757862","volume":"2019","author":"M Kennelly","year":"2019","unstructured":"Kennelly M, Thiruchelvam N, Averbeck MA, Konstatinidis C, Chartier-Kastler E, Trojgaard P, et al. Adult neurogenic lower urinary tract dysfunction and intermittent catheterisation in a community setting: risk factors model for urinary tract infections. Adv Urol. 2019;2019:2757862.","journal-title":"Adv Urol"},{"issue":"Supplement 1","key":"1102_CR49","first-page":"114","volume":"33","author":"DCY Ye","year":"2019","unstructured":"Ye DCY, Jian Z, Li H, Wang K. Comparison of different types of catheters for intermittent self-catheterization: a systematic review and network meta-analysis. J Endourol. 2019;33(Supplement 1):114\u20135.","journal-title":"J Endourol"},{"key":"1102_CR50","unstructured":"Averch TD, Stoffel J, Goldman HB, Griebling TL, Lerner L, Newman DK, et al. AUA white paper on catheter-associated urinary tract infections: definitions and significance in the urologic patient. Am Urol Assoc. 2014:1\u201331."},{"issue":"5","key":"1102_CR51","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1086\/650482","volume":"50","author":"TM Hooton","year":"2010","unstructured":"Hooton TM, Bradley SF, Cardenas DD, Colgan R, Geerlings SE, Rice JC, Saint S, Schaeffer AJ, Tambayh PA, Tenke P, Nicolle LE. Diagnosis, prevention, and treatment of catheter-associated urinary tract infection in adults: 2009 international clinical practice guidelines from the infectious diseases society of America. Clin Infect Dis. 2010;50(5):37.","journal-title":"Clin Infect Dis"},{"issue":"10","key":"1102_CR52","doi-asserted-by":"publisher","first-page":"1668","DOI":"10.1016\/j.apmr.2009.04.010","volume":"90","author":"DD Cardenas","year":"2009","unstructured":"Cardenas DD, Hoffman JM. Hydrophilic catheters versus noncoated catheters for reducing the incidence of urinary tract infections: a randomized controlled trial. Arch Phys Med Rehabil. 2009;90(10):1668\u201371.","journal-title":"Arch Phys Med Rehabil"},{"issue":"8","key":"1102_CR53","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1038\/sc.2013.46","volume":"51","author":"S Afsar","year":"2013","unstructured":"Afsar S, Yemisci O, Cosar S, Cetin N. Compliance with clean intermittent catheterization in spinal cord injury patients: a long-term follow-up study. Spinal Cord. 2013;51(8):645\u20139.","journal-title":"Spinal Cord"},{"issue":"5","key":"1102_CR54","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1080\/10790268.2009.11754562","volume":"32","author":"LM Massa","year":"2009","unstructured":"Massa LM, Hoffman JM, Cardenas DD. Validity, accuracy, and predictive value of urinary tract infection signs and symptoms in individuals with spinal cord injury on intermittent catheterization. J Spinal Cord Med. 2009;32(5):568\u201373.","journal-title":"J Spinal Cord Med"},{"issue":"4","key":"1102_CR55","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/S1569-9056(13)60080-9","volume":"11","author":"V Samal","year":"2012","unstructured":"Samal V, Mecl J, Kyrianova A, Sram J. Using of hydrophylic-coated catheters for intermittent catheterization in the conditions of spinal cord unit. Eur Urol Suppl. 2012;11(4):101.","journal-title":"Eur Urol Suppl"},{"issue":"38","key":"1102_CR56","first-page":"S235","volume":"3","author":"M Couchman","year":"2019","unstructured":"Couchman M, Nunn A, Delaney D, Thavaseelan J, Bennett N, Rutherford C, et al. Cost-effectiveness of long-term intermittent catheterisation with hydrophilic and uncoated catheters in traumatic spinal cord injury in australia. Neurourol Urodyn Suppl. 2019;3(38):S235\u20137.","journal-title":"Neurourol Urodyn Suppl"},{"issue":"3","key":"1102_CR57","first-page":"4065","volume":"15","author":"MG Woodbury","year":"2008","unstructured":"Woodbury MG, Heyes KC, Askes HK. Intermittent catheterization practices following spinal cord injury: a national survey. Can J Urol. 2008;15(3):4065\u201372.","journal-title":"Can J Urol"},{"key":"1102_CR58","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.e8639","volume":"346","author":"SL Bermingham","year":"2013","unstructured":"Bermingham SL, Hodgkinson S, Wright S, Hayter E, Spinks J, Pellowe C. Intermittent self catheterisation with hydrophilic, gel reservoir, and non-coated catheters: a systematic review and cost effectiveness analysis. BMJ. 2013;346: e8639.","journal-title":"BMJ"},{"issue":"23","key":"1102_CR59","first-page":"8","volume":"3","author":"L Nicolle","year":"2014","unstructured":"Nicolle L. Catheter associated urinary tract infections. Antimicrob Resist Infect Control. 2014;3(23):8.","journal-title":"Antimicrob Resist Infect Control"},{"issue":"7","key":"1102_CR60","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1089\/neu.2017.5413","volume":"35","author":"K Christison","year":"2018","unstructured":"Christison K, Walter M, Wyndaele JJM, Kennelly M, Kessler TM, Noonan VK, et al. Intermittent catheterization: the devil is in the details. J Neurotrauma. 2018;35(7):985\u20139.","journal-title":"J Neurotrauma"},{"issue":"3\u20134","key":"1102_CR61","doi-asserted-by":"publisher","first-page":"122","DOI":"10.5489\/cuaj.337","volume":"7","author":"TC Hill","year":"2013","unstructured":"Hill TC, Baverstock R, Carlson KV, Estey EP, Gray GJ, Hill DC, et al. Best practices for the treatment and prevention of urinary tract infection in the spinal cord injured population: the Alberta context. Can Urol Assoc J. 2013;7(3\u20134):122.","journal-title":"Can Urol Assoc J"},{"issue":"10","key":"1102_CR62","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.1007\/s00345-018-2419-z","volume":"36","author":"PGB Romo","year":"2018","unstructured":"Romo PGB, Smith CP, Cox A, Averbeck MA, Dowling C, Beckford C, et al. Non-surgical urologic management of neurogenic bladder after spinal cord injury. World J Urol. 2018;36(10):1555\u201368.","journal-title":"World J Urol"},{"key":"1102_CR63","unstructured":"Cameron AP, Duran S, Barboglio-Romo P, Cox A, Averbeck MA, Beckford C, et al. Non-surgical urologic management of neurogenic bladder after spinal cord injury. Consens Commitee SIU-ICUD. 2017; 147\u201365. ISBN: 978-1-7750334-0-0."},{"key":"1102_CR64","unstructured":"Gould CV, Umscheid CA, Agarwal RK, Kuntz G, Pegues DA. Guideline for prevention of catheter-associated urinary tract infections. Healthc Infect Control Pract Advis Comm (HICPAC). 2009; 1\u201361. https:\/\/www.cdc.gov\/infectioncontrol\/guidelines\/cauti\/."},{"issue":"4","key":"1102_CR65","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1097\/QCO.0b013e32835565cc","volume":"25","author":"PA Tambyah","year":"2012","unstructured":"Tambyah PA, Oon J. Catheter-associated urinary tract infection. Curr Opin Infect Dis. 2012;25(4):365\u201370.","journal-title":"Curr Opin Infect Dis"},{"key":"1102_CR66","first-page":"CD006008","volume":"8","author":"J Prieto","year":"2017","unstructured":"Prieto J, Murphy CL, Moore KN, Fader M. WITHDRAWN: intermittent catheterisation for long-term bladder management. Cochrane Database Syst Rev. 2017;8:CD006008.","journal-title":"Cochrane Database Syst Rev"},{"issue":"2","key":"1102_CR67","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.rehab.2016.02.006","volume":"59","author":"X Biardeau","year":"2016","unstructured":"Biardeau X, Corcos J. Intermittent catheterization in neurologic patients: update on genitourinary tract infection and urethral trauma. Ann Phys Rehabil Med. 2016;59(2):125\u20139.","journal-title":"Ann Phys Rehabil Med"},{"key":"1102_CR68","unstructured":"Pannek JB, Castro-Diaz D, Del Popolo GK, Radziszewski P, Reitz AMS, Wyndaele J-J. Guidelines on neurogenic lower urinary tract dysfunction. Eur Assoc Urol. 2013. https:\/\/documents.pub\/document\/20-neurogenic-lutd-lr.html."},{"key":"1102_CR69","doi-asserted-by":"publisher","unstructured":"Moore KN, Fader M, Getliffe K. Long-term bladder management by intermittent catheterisation in adults and children. Cochrane Database Syst Rev. 2007;4:1\u201346. https:\/\/doi.org\/10.1002\/14651858.CD006008.pub2.","DOI":"10.1002\/14651858.CD006008.pub2"},{"key":"1102_CR70","unstructured":"Akaoui C. Teaching and supporting clean intermittent catheterisation for parents and children. Royal Children\u2019s Hospital Melbourne. 2019. https:\/\/www.rch.org.au\/rchcpg\/hospital_clinical_guideline_index\/Teaching_and_supporting_Clean_Intermittent_Catheterisation_for_parents_and_children\/."},{"issue":"1","key":"1102_CR71","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1590\/S0104-11692013000100023","volume":"21","author":"FF Ercole","year":"2013","unstructured":"Ercole FF, Macieira TG, Wenceslau LC, Martins AR, Campos CC, Chianca TC. Integrative review: evidences on the practice of intermittent\/indwelling urinary catheterization. Rev Lat Am Enfermagem. 2013;21(1):459\u201368.","journal-title":"Rev Lat Am Enfermagem"},{"issue":"1","key":"1102_CR72","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1097\/QCO.0000000000000031","volume":"27","author":"P Tenke","year":"2014","unstructured":"Tenke P, Koves B, Johansen TE. An update on prevention and treatment of catheter-associated urinary tract infections. Curr Opin Infect Dis. 2014;27(1):102\u20137.","journal-title":"Curr Opin Infect Dis"},{"issue":"4","key":"1102_CR73","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s11884-017-0452-1","volume":"12","author":"H Madersbacher","year":"2017","unstructured":"Madersbacher H. The dilemma with the terminology and the studies of intermittent catheterization: what is the best course of action? Curr Bladder Dysfunct Rep. 2017;12(4):349\u201353.","journal-title":"Curr Bladder Dysfunct Rep"},{"issue":"3","key":"1102_CR74","doi-asserted-by":"publisher","first-page":"A52","DOI":"10.1016\/j.jval.2015.03.304","volume":"18","author":"K Neovius","year":"2015","unstructured":"Neovius K, Svensson J, Aberg-Hakansson M, Lundqvist T. Effect of hydrophilic coating isotonic to urine on infections and complications among users of intermittent urinary catheters. Value Health. 2015;18(3):A52.","journal-title":"Value Health"},{"key":"1102_CR75","unstructured":"Lower urinary tract symptoms in men: management. National Institute for Health and Care Excellence (NICE). 2010."},{"issue":"1","key":"1102_CR76","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1038\/sc.2015.117","volume":"54","author":"JF Clark","year":"2016","unstructured":"Clark JF, Mealing SJ, Scott DA, Vogel LC, Krassioukov A, Spinelli M, et al. A cost-effectiveness analysis of long-term intermittent catheterisation with hydrophilic and uncoated catheters. Spinal Cord. 2016;54(1):73\u20137.","journal-title":"Spinal Cord"},{"issue":"1","key":"1102_CR77","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2016-012360","volume":"7","author":"C Rognoni","year":"2017","unstructured":"Rognoni C, Tarricone R. Healthcare resource consumption for intermittent urinary catheterisation: cost-effectiveness of hydrophilic catheters and budget impact analyses. BMJ Open. 2017;7(1): e012360.","journal-title":"BMJ Open"},{"issue":"1","key":"1102_CR78","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1590\/s1677-5538.ibju.2017.0221","volume":"44","author":"JC Truzzi","year":"2018","unstructured":"Truzzi JC, Teich V, Pepe C. Can hydrophilic coated catheters be beneficial for the public healthcare system in Brazil?\u2014A cost-effectiveness analysis in patients with spinal cord injuries. Int Braz J Urol. 2018;44(1):121\u201331.","journal-title":"Int Braz J Urol"},{"issue":"7","key":"1102_CR79","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1080\/13696998.2018.1443112","volume":"21","author":"B Welk","year":"2018","unstructured":"Welk B, Isaranuwatchai W, Krassioukov A, Husted Torp L, Elterman D. Cost-effectiveness of hydrophilic-coated intermittent catheters compared with uncoated catheters in Canada: a public payer perspective. J Med Econ. 2018;21(7):639\u201348.","journal-title":"J Med Econ"},{"issue":"3","key":"1102_CR80","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1111\/luts.12122","volume":"9","author":"T Watanabe","year":"2017","unstructured":"Watanabe T, Yamamoto S, Gotoh M, Saitoh T, Yokoyama O, Murata T, et al. Cost-effectiveness analysis of long-term intermittent self-catheterization with hydrophilic-coated and uncoated catheters in patients with spinal cord injury in Japan. LUTS Lower Urinary Tract Symptoms. 2017;9(3):142\u201350.","journal-title":"LUTS Lower Urinary Tract Symptoms"},{"issue":"2","key":"1102_CR81","first-page":"64","volume":"13","author":"SH Saadat","year":"2019","unstructured":"Saadat SH, Shepherd S, Van Asseldonk B, Elterman DS. Clean intermittent catheterization: single use vs. reuse. Can Urol Assoc J. 2019;13(2):64\u20139.","journal-title":"Can Urol Assoc J"},{"issue":"5","key":"1102_CR82","doi-asserted-by":"publisher","first-page":"239","DOI":"10.7257\/1053-816X.2015.35.5.239","volume":"35","author":"MA Hakansson","year":"2015","unstructured":"Hakansson MA, Neovius K, Norrback M, Svensson J, Lundqvist T. Health care utilization and complications rates among users of hydrophilic-coated catheters. Urol Nurs. 2015;35(5):239.","journal-title":"Urol Nurs"},{"issue":"5","key":"1102_CR83","doi-asserted-by":"publisher","first-page":"233","DOI":"10.7257\/1053-816X.2016.36.5.233","volume":"36","author":"MA Hakansson","year":"2016","unstructured":"Hakansson MA, Neovius K, Lundqvist T. Healthcare costs associated with hydrophilic-coated and non-coated urinary catheters for intermittent use in the United States. Urol Nurs. 2016;36(5):233.","journal-title":"Urol Nurs"},{"key":"1102_CR84","first-page":"115","volume":"59","author":"J Auger","year":"2007","unstructured":"Auger J, Rihaoui R, Francois N, Eustache F. Effect of short-term exposure to two hydrophilic-coated and one gel prelubricated urinary catheters on sperm vitality, motility and kinematics in vitro. Minerva Urol Nefrol. 2007;59:115\u201324.","journal-title":"Minerva Urol Nefrol"},{"issue":"5","key":"1102_CR85","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1177\/1352458518768722","volume":"25","author":"D McClurg","year":"2019","unstructured":"McClurg D, Bugge C, Elders A, Irshad T, Hagen S, Moore KN, et al. Factors affecting continuation of clean intermittent catheterisation in people with multiple sclerosis: results of the COSMOS mixed-methods study. Mult Scler. 2019;25(5):727\u201339.","journal-title":"Mult Scler"},{"key":"1102_CR86","first-page":"191","volume":"8","author":"JH Seth","year":"2014","unstructured":"Seth JH, Haslam C, Panicker JN. Ensuring patient adherence to clean intermittent self-catheterization. Patient Prefer Adherence. 2014;8:191\u20138.","journal-title":"Patient Prefer Adherence"},{"issue":"5","key":"1102_CR87","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1038\/nrmicro3432","volume":"13","author":"AL Flores-Mireles","year":"2015","unstructured":"Flores-Mireles AL, Walker JN, Caparon M, Hultgren SJ. Urinary tract infections: epidemiology, mechanisms of infection and treatment options. Nat Rev Microbiol. 2015;13(5):269\u201384.","journal-title":"Nat Rev Microbiol"},{"issue":"1","key":"1102_CR88","first-page":"13","volume":"113","author":"M Siroko","year":"2002","unstructured":"Siroko M. Pathogenesis of Bacteriuria and Infection in the spinal cord injured patient. Am J Med. 2002;113(1):13.","journal-title":"Am J Med"},{"issue":"4","key":"1102_CR89","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1038\/sj.sc.3100817","volume":"37","author":"F Biering-S\u00f8rensen","year":"1999","unstructured":"Biering-S\u00f8rensen F, Nielsen K, Hansen HV. Urethral epithelial cells on the surface on hydrophilic catheters after interittent catheterization: cross-over study with two catheters. Spinal cord. 1999;37(4):2.","journal-title":"Spinal cord"},{"key":"1102_CR90","first-page":"CD006008","volume":"10","author":"JA Prieto","year":"2021","unstructured":"Prieto JA, Murphy CL, Stewart F, Fader M. Intermittent catheter techniques, strategies and designs for managing long-term bladder conditions. Cochrane Database Syst Rev. 2021;10:CD006008.","journal-title":"Cochrane Database Syst Rev"}],"container-title":["BMC Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-022-01102-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12894-022-01102-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-022-01102-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,19]],"date-time":"2022-09-19T20:35:01Z","timestamp":1663619701000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcurol.biomedcentral.com\/articles\/10.1186\/s12894-022-01102-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,19]]},"references-count":90,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1102"],"URL":"https:\/\/doi.org\/10.1186\/s12894-022-01102-8","relation":{},"ISSN":["1471-2490"],"issn-type":[{"value":"1471-2490","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,19]]},"assertion":[{"value":"15 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"While engaging in this research, the authors were employed by Coloplast A\/S, Humlebaek, Denmark, which develops ostomy, continence, interventional urology, wound and skin care products and services.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"153"}}