{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T04:50:39Z","timestamp":1791262239476,"version":"4.1.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T00:00:00Z","timestamp":1783900800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T00:00:00Z","timestamp":1791244800000},"content-version":"vor","delay-in-days":85,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Urol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The intrauterine device (IUD) is an important and highly effective means of contraception. Migration of the IUD, post implantation, out of the uterus is an infrequent complication, and an IUD partially perforating the bladder is even more infrequently reported. The authors report a 44-year-old woman who had a copper-M IUD inserted into her uterus 16 years ago. Six months later an unexpected pregnancy occurred and an elective suction abortion was performed without ultrasound check before or after surgery. A copper-T IUD was inserted immediately after completion of the abortion but she was subsequently lost to follow-up. Before detection of the ectopic state of the IUD, she complained of lower quadrant abdominal pain following urination for one month. Physical examination revealed mild tenderness upon deep palpation of the suprapubic area. A series of imaging studies had been performed to confirm the exact position of the ectopic IUD. Transabdominal ultrasound showed a linear hyperechoic foreign body embedded in the right side of the bladder wall, a plain abdominal X-ray showed an M-shaped IUD on the right side of the pelvis, an abdominal CT scan found a portion of one arm penetrated the right anterior bladder wall, and nephroscopy demonstrated a one-centimeter of penetration depth and surrounding calculus formation. The IUD arm was gently pulled into the bladder with forceps and was subsequently removed through the urethra. A Foley catheter was later placed into the bladder for one week to manage the bladder perforation. The patient made an uneventful recovery.<\/jats:p>\n                  <jats:p>This case demonstrates that partial bladder perforation with the IUD body outside the bladder can be successfully managed via transurethral nephroscopy. A stepwise imaging strategy (ultrasound \u2192 KUB \u2192 CT) is essential for surgical planning. We propose a treatment-oriented classification and a replicable clinical pathway integrating multidisciplinary collaboration and tailored technology selection.<\/jats:p>","DOI":"10.1186\/s12894-026-02256-5","type":"journal-article","created":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T00:54:11Z","timestamp":1783904051000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Nephroscopic management of partial bladder perforation by an intrauterine device with extravesical main body: a case report and treatment-oriented classification"],"prefix":"10.1186","volume":"26","author":[{"given":"Haiying","family":"Niu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruirui","family":"Ge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiajia","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shijie","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Quanxin","family":"Qu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,13]]},"reference":[{"key":"2256_CR1","doi-asserted-by":"publisher","first-page":"9362962","DOI":"10.1155\/2018\/9362962","volume":"2018","author":"ML Cheung","year":"2018","unstructured":"Cheung ML, Rezai S, Jackman JM, Patel ND, Bernaba BZ, Hakimian O, et al. Retained Intrauterine Device (IUD): Triple Case Report and Review of the Literature. Case Rep Obstet Gynecol. 2018;2018:9362962.","journal-title":"Case Rep Obstet Gynecol"},{"issue":"1","key":"2256_CR2","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1186\/s12905-021-01443-w","volume":"21","author":"G Liu","year":"2021","unstructured":"Liu G, Li F, Ao M, Huang G. Intrauterine devices migrated into the bladder: two case reports and literature review. BMC Womens Health. 2021;21(1):301.","journal-title":"BMC Womens Health"},{"issue":"7","key":"2256_CR3","doi-asserted-by":"publisher","first-page":"e33857","DOI":"10.1097\/MD.0000000000033857","volume":"103","author":"G Jia","year":"2024","unstructured":"Jia G, Liu X, He Y, Du P, Sun Z, Chai W. Asymptomatic uterine perforation and IUD migration to the broad ligament: A case report. Med (Baltim). 2024;103(7):e33857.","journal-title":"Med (Baltim)"},{"key":"2256_CR4","doi-asserted-by":"publisher","first-page":"111409","DOI":"10.1016\/j.ijscr.2025.111409","volume":"131","author":"Y Jaziri","year":"2025","unstructured":"Jaziri Y, Saidani B, Saadi A, Haroun A, Chakroun M, Ben Slama R. Intrauterine device migration into the bladder with urolithiasis: A case report. Int J Surg Case Rep. 2025;131:111409.","journal-title":"Int J Surg Case Rep"},{"issue":"1","key":"2256_CR5","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1186\/s12894-024-01676-5","volume":"24","author":"F Yu","year":"2024","unstructured":"Yu F, Chen M, Cao H, Yang G, Wang W, Wang Y. Intrauterine device (IUD) migration completely into the abdominal cavity and half into the bladder to form a stone: a case report and mini-review. BMC Urol. 2024;24(1):280.","journal-title":"BMC Urol"},{"issue":"4","key":"2256_CR6","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/0002-9378(73)90128-2","volume":"117","author":"JM Esposito","year":"1973","unstructured":"Esposito JM, Zarou DM, Zarou GS. A Dalkon Shield imbedded in a myoma: case report of an unusual displacement of an intrauterine contraceptive device. Am J Obstet Gynecol. 1973;117(4):578\u201381.","journal-title":"Am J Obstet Gynecol"},{"issue":"6","key":"2256_CR7","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1016\/0010-7824(89)90036-X","volume":"39","author":"IC Chi","year":"1989","unstructured":"Chi IC, Potts M, Wilkens LR, Champion CB. Performance of the copper T-380A intrauterine device in breastfeeding women. Contraception. 1989;39(6):603\u201318.","journal-title":"Contraception"},{"key":"2256_CR8","doi-asserted-by":"publisher","first-page":"e00447","DOI":"10.1016\/j.crwh.2022.e00447","volume":"36","author":"G Maree","year":"2022","unstructured":"Maree G, Mohammad S, Saleh R, Hoshma A, Makhluf H. Appendiceal perforation caused by an intrauterine contraceptive device: A case report. Case Rep Womens Health. 2022;36:e00447.","journal-title":"Case Rep Womens Health"},{"issue":"41","key":"2256_CR9","doi-asserted-by":"publisher","first-page":"e45184","DOI":"10.1097\/MD.0000000000045184","volume":"104","author":"W Liu","year":"2025","unstructured":"Liu W, Zhang Y, Qian L, Zhang Z. Partial intrauterine device migration into the abdominal cavity with bladder penetration and stone formation: A case report and multidisciplinary management. Med (Baltim). 2025;104(41):e45184.","journal-title":"Med (Baltim)"},{"issue":"Suppl 1","key":"2256_CR10","first-page":"1","volume":"49","author":"FSRH Guideline (March 2023)","year":"2023","unstructured":"FSRH Guideline (March 2023). Intrauterine contraception. BMJ Sex Reprod Health. 2023;49(Suppl 1):1\u2013142.","journal-title":"BMJ Sex Reprod Health"},{"key":"2256_CR11","doi-asserted-by":"publisher","first-page":"143","DOI":"10.11604\/pamj.2022.42.143.35362","volume":"42","author":"BU Ago","year":"2022","unstructured":"Ago BU, Enakirerhi G. Bladder stone caused by misplaced intrauterine contraceptive device: a case report. Pan Afr Med J. 2022;42:143.","journal-title":"Pan Afr Med J"},{"issue":"2","key":"2256_CR12","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s00192-007-0413-x","volume":"19","author":"AS El-Hefnawy","year":"2008","unstructured":"El-Hefnawy AS, El-Nahas AR, Osman Y, Bazeed MA. Urinary complications of migrated intrauterine contraceptive device. Int Urogynecol J Pelvic Floor Dysfunct. 2008;19(2):241\u20135.","journal-title":"Int Urogynecol J Pelvic Floor Dysfunct"},{"key":"2256_CR13","doi-asserted-by":"crossref","unstructured":"Varlas VN, Meianu AI, R\u0103doi AI, Balescu I, Bacalbasa N, Varlas RG. Intrauterine Contraceptive Device Migrated in the Urinary Tract: Case Report and Extensive Literature Review. J Clin Med. 2024;13(14):4233.","DOI":"10.3390\/jcm13144233"},{"issue":"2","key":"2256_CR14","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1148\/rg.322115068","volume":"32","author":"HE Boortz","year":"2012","unstructured":"Boortz HE, Margolis DJ, Ragavendra N, Patel MK, Kadell BM. Migration of intrauterine devices: radiologic findings and implications for patient care. Radiographics. 2012;32(2):335\u201352.","journal-title":"Radiographics"},{"issue":"1","key":"2256_CR15","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/s12894-025-01780-0","volume":"25","author":"EG Malki","year":"2025","unstructured":"Malki EG, Sbeih D, Bael P, Alsarabta H, Alzawahra A. The rolling stone: migration of an intrauterine device leading to bladder stone formation nine years after insertion: a case report. BMC Urol. 2025;25(1):93.","journal-title":"BMC Urol"},{"key":"2256_CR16","first-page":"2091915","volume":"2020","author":"MA Nouioui","year":"2020","unstructured":"Nouioui MA, Taktak T, Mokadem S, Mediouni H, Khiari R, Ghozzi S. A Mislocated Intrauterine Device Migrating to the Urinary Bladder: An Uncommon Complication Leading to Stone Formation. Case Rep Urol. 2020;2020:2091915.","journal-title":"Case Rep Urol"},{"key":"2256_CR17","doi-asserted-by":"publisher","first-page":"41","DOI":"10.2147\/OAJC.S458156","volume":"15","author":"V Verstraeten","year":"2024","unstructured":"Verstraeten V, Vossaert K, Van den Bosch T. Migration of Intra-Uterine Devices. Open Access J Contracept. 2024;15:41\u20137.","journal-title":"Open Access J Contracept"},{"key":"2256_CR18","doi-asserted-by":"publisher","first-page":"1390","DOI":"10.12688\/f1000research.136351.1","volume":"12","author":"A Agil","year":"2023","unstructured":"Agil A, Tjahjodjati T, Atik N, Rachmadi D, Zahrina TT. Case Report: Iatrogenic trauma of the bladder due to long-term unidentified intrauterine device malposition inside the bladder with rectovesical fistula. F1000Res. 2023;12:1390.","journal-title":"F1000Res"},{"issue":"2","key":"2256_CR19","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1007\/s00192-018-3746-8","volume":"30","author":"H Niu","year":"2019","unstructured":"Niu H, Zhang L, Yao S, Qu Q. Successful removal of an intrauterine device perforating the uterus and the bladder with the aid of a transurethral nephroscope. Int Urogynecol J. 2019;30(2):325\u20136.","journal-title":"Int Urogynecol J"},{"issue":"6","key":"2256_CR20","doi-asserted-by":"publisher","first-page":"e8","DOI":"10.1097\/SPV.0000000000000121","volume":"20","author":"JM Scovell","year":"2014","unstructured":"Scovell JM, Chan RC, Smith CP. Transurethral use of a nephroscope significantly AIDS in the surgical management of an intrauterine device eroding into the bladder. Female Pelvic Med Reconstr Surg. 2014;20(6):e8\u201311.","journal-title":"Female Pelvic Med Reconstr Surg"},{"issue":"7","key":"2256_CR21","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1097\/00006254-198107000-00001","volume":"36","author":"D Zakin","year":"1981","unstructured":"Zakin D, Stern WZ, Rosenblatt R. Complete and partial uterine perforation and embedding following insertion of intrauterine devices. I. Classification, complications, mechanism, incidence, and missing string. Obstet Gynecol Surv. 1981;36(7):335\u201353.","journal-title":"Obstet Gynecol Surv"},{"issue":"4","key":"2256_CR22","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/S1726-4901(08)70105-9","volume":"71","author":"MO Istanbulluoglu","year":"2008","unstructured":"Istanbulluoglu MO, Ozcimen EE, Ozturk B, Uckuyu A, Cicek T, Gonen M. Bladder perforation related to intrauterine device. J Chin Med Assoc. 2008;71(4):207\u20139.","journal-title":"J Chin Med Assoc"},{"issue":"6","key":"2256_CR23","first-page":"e62467","volume":"16","author":"E Gupta","year":"2024","unstructured":"Gupta E, Prabhudesai M, Halarnakar R, Lawande P, Gaude V. Cystoscopic Management of the Intravesical Migration of an Intrauterine Device Complicated by Bladder Stone Formation: A Video Case Report. Cureus. 2024;16(6):e62467.","journal-title":"Cureus"},{"issue":"1","key":"2256_CR24","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1186\/s13104-015-1792-6","volume":"9","author":"CK Gyasi-Sarpong","year":"2016","unstructured":"Gyasi-Sarpong CK, Maison POM, Morhe E, Aboah K, Appiah KA-A, Azorliade R, et al. Intravesical migration of an intrauterine device. BMC Res Notes. 2016;9(1):4.","journal-title":"BMC Res Notes"},{"issue":"1788","key":"2256_CR25","first-page":"25","volume":"259","author":"AM Voulgaris","year":"2015","unstructured":"Voulgaris AM, Lee T, Habib A, Kavia R. The case of the migrating IUD. Practitioner. 2015;259(1788):25\u20137.","journal-title":"Practitioner"},{"issue":"6","key":"2256_CR26","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1159\/000538759","volume":"31","author":"J Rev\u00e9s","year":"2024","unstructured":"Rev\u00e9s J, Bravo AC, Abreu BS, Gamito M, Figueiredo AN, Loureiro R. Endoscopic Retrieval of Migrated Uterine Device: Case Report. GE Port J Gastroenterol. 2024;31(6):429\u201331.","journal-title":"GE Port J Gastroenterol"},{"issue":"7","key":"2256_CR27","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1111\/jog.15661","volume":"49","author":"M Zhang","year":"2023","unstructured":"Zhang M, Sun Z, Yang Y, Zhou J, Ba L. Complete perforated bladder from intrauterine devices: A case series report from a nationwide monitoring system. J Obstet Gynaecol Res. 2023;49(7):1821\u20136.","journal-title":"J Obstet Gynaecol Res"},{"issue":"2","key":"2256_CR28","doi-asserted-by":"publisher","first-page":"236","DOI":"10.4293\/108680812X13427982377265","volume":"16","author":"FR Mosley","year":"2012","unstructured":"Mosley FR, Shahi N, Kurer MA. Elective surgical removal of migrated intrauterine contraceptive devices from within the peritoneal cavity: a comparison between open and laparoscopic removal. Jsls. 2012;16(2):236\u201341.","journal-title":"Jsls"},{"issue":"11\u201312","key":"2256_CR29","first-page":"543","volume":"60","author":"H Niu","year":"2015","unstructured":"Niu H, Qu Q, Yang X, Zhang L. Partial Perforation of the Bladder by an Intrauterine Device in a Pregnant Woman: A Case Report. J Reprod Med. 2015;60(11\u201312):543\u20136.","journal-title":"J Reprod Med"},{"issue":"7","key":"2256_CR30","first-page":"e87377","volume":"17","author":"LE Torres Zapata","year":"2025","unstructured":"Torres Zapata LE, Maldonado Calder\u00f3n JL, Aguilar Urrea LF, Garcia Bail\u00f3n AM, Molgado Garza VM. Minimally Invasive Approach to Intrauterine Device Migration Into the Bladder Using Holmium Laser. Cureus. 2025;17(7):e87377.","journal-title":"Cureus"},{"key":"2256_CR31","doi-asserted-by":"publisher","first-page":"1405129","DOI":"10.3389\/fsurg.2024.1405129","volume":"11","author":"P Gong","year":"2024","unstructured":"Gong P, Shen J. An unexpected complication after removing bladder foreign body: a case report. Front Surg. 2024;11:1405129.","journal-title":"Front Surg"},{"issue":"4","key":"2256_CR32","first-page":"1847","volume":"11","author":"D Campobasso","year":"2014","unstructured":"Campobasso D, Ciuffreda M, Maestroni U, Dinale F, Frattini A, Ferretti S. Laparoscopic removal of an intrauterine contraceptive device migrated into the bladder: a case report. Urol J. 2014;11(4):1847\u20138.","journal-title":"Urol J"},{"issue":"17","key":"2256_CR33","doi-asserted-by":"publisher","first-page":"3221","DOI":"10.12998\/wjcc.v12.i17.3221","volume":"12","author":"SX Liu","year":"2024","unstructured":"Liu SX, Dong XY. Using laparoscope to remove an ectopic intrauterine device in the anterior wall of urinary bladder: A case report. World J Clin Cases. 2024;12(17):3221\u20135.","journal-title":"World J Clin Cases"},{"key":"2256_CR34","first-page":"8074689","volume":"2023","author":"C Heaney","year":"2023","unstructured":"Heaney C, Lee P, Winer A. Robot-Assisted Removal of a Partially Intravesical Intrauterine Device (IUD) and Large Bladder Stone. Case Rep Urol. 2023;2023:8074689.","journal-title":"Case Rep Urol"}],"container-title":["BMC Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12894-026-02256-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-026-02256-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-026-02256-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T03:57:17Z","timestamp":1791259037000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12894-026-02256-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,13]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2256"],"URL":"https:\/\/doi.org\/10.1186\/s12894-026-02256-5","relation":{},"ISSN":["1471-2490"],"issn-type":[{"value":"1471-2490","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,13]]},"assertion":[{"value":"7 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This institution does not require Institutional Review Board approval for case reports. Considering the ethical principles, the patient\u2019s name was not mentioned in the paper.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"235"}}