{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T19:51:47Z","timestamp":1785527507005,"version":"3.56.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T00:00:00Z","timestamp":1785196800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T00:00:00Z","timestamp":1785196800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum D\u00fcsseldorf. Anstalt \u00f6ffentlichen Rechts"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Urol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and objective<\/jats:title>\n                    <jats:p>Flexible cystoscopy is integral to outpatient urology, particularly for surveillance of non\u2013muscle-invasive bladder cancer. Real-world economic data comparing reusable (RU) and single-use (SU) cystoscopes in German outpatient practice are scarce. We evaluated procedure-level costs and multidisciplinary user perceptions under routine conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A micro-costing analysis was performed in a German outpatient urology centre (337 cystoscopies\/year). Capital investment (5-year amortisation), maintenance, reprocessing, consumables, and labour were included. Baseline and full-equipment replacement scenarios were modelled, and break-even thresholds calculated. A standardised survey of 13 physicians and 25 nursing staff from five practices assessed technical performance and workflow domains (5-point Likert scale). Groups were compared using Mann\u2013Whitney U tests with Cliff\u2019s delta.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Mean per-procedure cost was \u20ac27.25 for RU and \u20ac179.00 for SU. RU became cost-effective beyond 67 procedures annually; this threshold increased to 265 procedures when modelling full equipment renewal (\u20ac43,050). Physicians rated RU superior for manoeuvrability (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.02) and SU superior for logistics (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.02), with no differences in image quality, ergonomics, diagnostic confidence, or overall impression. Nursing staff favoured SU across all domains (all\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), particularly reprocessing workload and reliability. Limitations include single-centre design, evaluation of one device per category, context-specific reimbursement structures, and absence of primary environmental or patient-reported outcomes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In high-volume outpatient settings, RU cystoscopes are economically advantageous. However, SU devices offer substantial workflow benefits. Device selection should be context-specific, integrating case volume, infrastructure, and multidisciplinary perspectives.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12894-026-02284-1","type":"journal-article","created":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T13:38:26Z","timestamp":1785245906000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Reusable vs single-use flexible cystoscopes in outpatient urology: a real-world micro-costing and user evaluation"],"prefix":"10.1186","volume":"26","author":[{"given":"Felix","family":"Seelemeyer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rouvier","family":"Al-Monajjed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Philipp","family":"Radtke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"N\u00fcesch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Herden","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sassan","family":"Nazari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruben","family":"G\u00f6\u00dfmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,28]]},"reference":[{"issue":"11","key":"2284_CR1","doi-asserted-by":"publisher","first-page":"4275","DOI":"10.1007\/s00345-021-03724-3","volume":"39","author":"ZT Su","year":"2021","unstructured":"Su ZT, Huang MM, Matlaga BR, Hutfless S, Koo K. A micro-costing analysis of outpatient flexible cystoscopy: implications for adoption of single-use flexible cystoscopes. World J Urol. 2021;39(11):4275\u201381.","journal-title":"World J Urol"},{"key":"2284_CR2","doi-asserted-by":"publisher","unstructured":"Hoffman D, Cool C. Costs involved in compliance with new endoscope reprocessing guidelines. Clin Endosc. 2024;57(4):534\u201341. https:\/\/doi.org\/10.5946\/ce.2023.16410.","DOI":"10.5946\/ce.2023.16410"},{"issue":"1","key":"2284_CR3","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1089\/end.2023.0372","volume":"38","author":"R Chen","year":"2023","unstructured":"Chen R, Baas C, Farkouh Aa, Shete K, Peverini DR, Hartman JC, et al. Time Efficiency and Performance of Single-Use vs Reusable Cystoscopes: A Randomized Benchtop and Simulated Clinical Assessment. J Endourol. 2023;38(1):53\u20139.","journal-title":"J Endourol"},{"issue":"5","key":"2284_CR4","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1111\/bju.15949","volume":"131","author":"JP Kemble","year":"2023","unstructured":"Kemble JP, Winoker JS, Patel SH, Su ZT, Matlaga BR, Potretzke AM, et al. Environmental impact of single-use and reusable flexible cystoscopes. BJU Int. 2023;131(5):617\u201322.","journal-title":"BJU Int"},{"key":"2284_CR5","unstructured":"Body Products Relax Pharma und Kosmetik GmbH. UROFINO\u2122 Einweg-Ureteroskope & Zystoskope: F\u00fcr diagnostische und therapeutische Eingriffe in Harnleiter und Harnblase. WM-Nr. 041 (D), Rev. 00. Frechen: Body Products Relax Pharma und Kosmetik GmbH; September 2025. Available from: BPRPBV. Endoskopie-Urologie \u2013 Produktbrosch\u00fcre Geretsried, Deutschland: Body products Relax Pharma & Beauty Vertriebsgesellschaft mbH; 2023. https:\/\/body-products.de\/wp-content\/uploads\/2025\/10\/Flyer_Urofino_Einweg-Ureteroskope-und-Zystoskope_WM-Nr.-041-DE_September-2025_Rev.-00.pdfmbH."},{"key":"2284_CR6","unstructured":"America O. Flexible Cysto-Nephro Fiberscope (CYF-5) 2025. Available from: https:\/\/medical.olympusamerica.com\/products\/flexible-cysto-nephroscope\/cyf-5."},{"issue":"4","key":"2284_CR7","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1097\/UPJ.0000000000000236","volume":"8","author":"JA Young","year":"2021","unstructured":"Young JA, Garden EB, Al-Alao O, Deoraj D, Small AC, Hruby G, et al. Disposable versus Reusable Cystoscopes: A Micro-Costing Value Analysis in High-Volume and Low-Volume Urology Practices. Urol Pract. 2021;8(4):466\u201371.","journal-title":"Urol Pract"},{"issue":"10","key":"2284_CR8","doi-asserted-by":"publisher","first-page":"346","DOI":"10.5489\/cuaj.7828","volume":"16","author":"J Kim","year":"2022","unstructured":"Kim J, Gao B, Bhojani N, Zorn KC, Chughtai B, Elterman DS. Micro-cost analysis of single-use vs. reusable cystoscopy in a single-payer healthcare system. Can Urol Assoc J. 2022;16(10):346\u201350.","journal-title":"Can Urol Assoc J"},{"key":"2284_CR9","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.urology.2021.05.008","volume":"157","author":"AP Kenigsberg","year":"2021","unstructured":"Kenigsberg AP, Gold S, Grant L, Lotan Y. The Economics of Cystoscopy: A Microcost Analysis. Urology. 2021;157:29\u201334.","journal-title":"Urology"},{"key":"2284_CR10","doi-asserted-by":"publisher","unstructured":"Franzoso G, Zorzetto G, Dal Bello S, Giuriola A, Casarin A, Stef\u00e0no A, et al. Institutional single-center cost-opportunity analysis of disposable vs. reusable cystoscopes in a referral oncology center. Expert Rev Pharmacoecon Outcomes Res. 2026;26(1):87\u201395. https:\/\/doi.org\/10.1080\/14737167.2025.258317810.","DOI":"10.1080\/14737167.2025.258317810"},{"key":"2284_CR11","doi-asserted-by":"publisher","unstructured":"Foo JCH, Lim EJ, Lee SZ, Yong J. To throw, or not to throw: threshold cost analysis of the single-use flexible cystoscopy model in a high-volume urology centre. ANZ J Surg. Published online 23 Dec 2025. https:\/\/doi.org\/10.1111\/ans.7045110.","DOI":"10.1111\/ans.7045110"},{"issue":"10","key":"2284_CR12","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.1089\/end.2022.0201","volume":"36","author":"T Boucheron","year":"2022","unstructured":"Boucheron T, Lechevallier E, Gondran-Tellier B, Michel F, Bastide C, Martin N, et al. Cost and Environmental Impact of Disposable Flexible Cystoscopes Compared to Reusable Devices. J Endourol. 2022;36(10):1317\u201321.","journal-title":"J Endourol"},{"issue":"1","key":"2284_CR13","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1007\/s00345-025-05705-2","volume":"43","author":"S Ait Taleb","year":"2025","unstructured":"Ait Taleb S, Francois N, Tehhani BE, Perez T. Reusable vs. single use cystoscope: economic & environmental assessment. World J Urol. 2025;43(1):323.","journal-title":"World J Urol"},{"key":"2284_CR14","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.urology.2024.03.023","volume":"188","author":"R Bertolo","year":"2024","unstructured":"Bertolo R, Gilioli V, Veccia A, Malandra S, Dal Corso L, Fenzi D, et al. Institutional Micro-Cost Comparative Analysis of Reusable vs Single-use Cystoscopes With Assessment of Environmental Footprint. Urology. 2024;188:70\u20136.","journal-title":"Urology"},{"issue":"4","key":"2284_CR15","first-page":"118","volume":"14","author":"MA Assmus","year":"2019","unstructured":"Assmus MA, McLarty R, Senthilselvan A, De SK. Direct to cystoscopy: A prospective quality assessment of patient preferences. Can Urol Association J. 2019;14(4):118\u201321.","journal-title":"Can Urol Association J"},{"issue":"7","key":"2284_CR16","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1007\/s00120-018-0701-8","volume":"57","author":"F Schramm","year":"2018","unstructured":"Schramm F, Kuball L. [Federal Social Court of Germany: no entitlement to unbudgeted remuneration of cystoscopies according to the AOP contract]. Urologe A. 2018;57(7):811\u20132.","journal-title":"Urologe A"},{"issue":"1","key":"2284_CR17","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1089\/end.2022.0210","volume":"37","author":"A Holmes","year":"2023","unstructured":"Holmes A, O\u2019Kane D, Wombwell A, Grills R. Clinical Utility of a Single-Use Flexible Cystoscope Compared with a Standard Reusable Device: A Randomized Noninferiority Study. J Endourol. 2023;37(1):80\u20134.","journal-title":"J Endourol"},{"issue":"11","key":"2284_CR18","doi-asserted-by":"publisher","first-page":"3175","DOI":"10.1007\/s00345-023-04636-0","volume":"41","author":"M Oderda","year":"2023","unstructured":"Oderda M, Asimakopoulos A, Batetta V, Bosio A, Dalmasso E, Morra I, et al. Single-use digital flexible cystoscope for double J removal versus reusable instruments: a prospective, comparative study of functionality, risk of infection, and costs. World J Urol. 2023;41(11):3175\u201380.","journal-title":"World J Urol"},{"issue":"1","key":"2284_CR19","doi-asserted-by":"publisher","first-page":"13495","DOI":"10.1038\/s41598-020-70424-0","volume":"10","author":"RM Seyam","year":"2020","unstructured":"Seyam RM, Zeitouni OM, Alsibai TM, AlAyoub AJ, Al-Qassab OM, AlDeiry MA, et al. The grasper-integrated disposable flexible cystoscope is comparable to the reusable, flexible cystoscope for the detection of bladder cancer. Sci Rep. 2020;10(1):13495.","journal-title":"Sci Rep"},{"issue":"1","key":"2284_CR20","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1111\/bju.16206","volume":"133","author":"S Anderson","year":"2024","unstructured":"Anderson S, Patterson K, Skolarikos A, Somani B, Bolton DM, Davis NF. Perspectives on technology: to use or to reuse, that is the endoscopic question-a systematic review of single-use endoscopes. BJU Int. 2024;133(1):14\u201324.","journal-title":"BJU Int"},{"issue":"6","key":"2284_CR21","first-page":"11361","volume":"29","author":"J Lee","year":"2022","unstructured":"Lee J, Kaplan-Marans E, Jivanji D, Tennenbaum D, Schulman A. Post-cystoscopy infections and device malfunctions in reprocessed flexible cystoscopes in a national database. Can J Urol. 2022;29(6):11361\u20135.","journal-title":"Can J Urol"},{"issue":"5","key":"2284_CR22","doi-asserted-by":"publisher","first-page":"2098","DOI":"10.1016\/j.juro.2007.07.014","volume":"178","author":"BK Canales","year":"2007","unstructured":"Canales BK, Gleason JM, Hicks N, Monga M. An Independent Analysis of Flexible Cystoscope Repairs and Cost. J Urol. 2007;178(5):2098\u2013102.","journal-title":"J Urol"},{"issue":"1","key":"2284_CR23","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1186\/s12894-024-01436-5","volume":"24","author":"I Haislip","year":"2024","unstructured":"Haislip I, Rindorf D, Cool C, Tester B. Workflow efficiencies for flexible cystoscopy: comparing single-use vs reusable cystoscopes. BMC Urol. 2024;24(1):53.","journal-title":"BMC Urol"}],"container-title":["BMC Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12894-026-02284-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-026-02284-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12894-026-02284-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T18:13:07Z","timestamp":1785521587000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12894-026-02284-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,28]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2284"],"URL":"https:\/\/doi.org\/10.1186\/s12894-026-02284-1","relation":{},"ISSN":["1471-2490"],"issn-type":[{"value":"1471-2490","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,28]]},"assertion":[{"value":"8 May 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was conducted in accordance with the principles of the Declaration of Helsinki. The analysis included anonymized cost data from routine outpatient practice and an anonymous voluntary survey of physicians and nursing staff. No patient-identifiable data, patient-level clinical data, human tissue, or intervention-related patient data were collected or analysed. Ethics approval was obtained from the Ethics Committee of the Medical Faculty of the University of D\u00fcsseldorf.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. The manuscript does not contain any individual person\u2019s data, images, videos, or other identifiable personal information.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"180"}}